HomeMy WebLinkAbout5178 38 Indian Memorial Dr Elevation and Floor Plans 04.23.24APRIL 23, 2024
SECOND FLOOR ADDITION
TO POULAKOS RESIDENCE
38 INDIAN MEMORIAL DRIVE
SOUTH YARMOUTH MA 02664
PLANS PREPARED BY
DESIGN BY SAMI LLC
81 OCEANSIDE DRIVE
SCITUATE, MA 02066
617-460-1041 - Sami@designbysami.com
CONTRACTOR
JAMES PAPAS CONSTRUCTION
162 WEST STREET
BROCKTON, MA 02301
508-942-5321 Papasd@hotmail.com
CHECKED: SK DRAWN BY: AK ISSUED FORCONSTRUCTIONAPRIL 23, 2025PROJECT LOCATION38 INDIAN MEMORIAL DRIVESOUTH YARMOUTH, MA 026646CONTRACTORPROJECT TYPESECOND FLOOR ADDITIONRESIDENTIAL R-3PLANS PREPARED BYDESIGN BY SAMI LLC.81 OCEANSIDE DRIVESCITUATE, MA 02066APRIL 23, 2025
DESIGN IS BASED ON THE MASSACHUSETTS BUILDING CODE 10TH EDITION
IT IS THE INTENT OF THESE PLANS TO DEPICT CONSTRUCTION IN
ACCORDANCE WITH MA STATE BUILDING CODE 9TH EDITION. THE STATE
BUILDING CODE IS PART OF THESE CONSTRUCTION PLANS.
ALL WORK SHALL BE CONDUCTED, INSTALLED, PROTECTED AND
COMPLETED IN A WORKMANLIKE AND ACCEPTABLE MANNER SO AS TO
SECURE THE RESULTS INTENDED BY STATE BUILDING CODE.
CONTRACTOR MUST HAVE A COPY OF THE STATE BUILDING CODE AND A
COPY OF THESE PLANS ON SITE AT ALL TIME DURING CONSTRUCTION. ANY
OMISSION ON THESE PLANS DOES NOT RELIEVE THE CONTRACTOR
RESPONSIBILITIES TO COMPLY WITH THE STATE BUILDING CODE.
DESIGN LIVE LOAD FIRST FLOOR = 40 PSF
DESIGN LIVE LOAD SECOND FLOOR = 30 PSF
DESIGN LIVE LOAD ATTIC FLOOR = 10 PSF
DESIGN SNOW LOAD Pg = 30 PSF
DESIGN SNOW LOAD FLAT ROOF Pf = 25 PSF
DESIGN WIND LOAD Vult = 131 MPH
ALL LUMBER/MATERIAL SUPPLIES SHALL MEET THE REQUIREMENTS OF
THE MASSACHUSETTS STATE BUILDING CODE FOR STRUCTURE GRADE 2
OR BETTER.
ALL WOOD EXPOSED TO WEATHER SHALL BE P.T.
ALL DIMENSIONS SHOWN MUST BE VERIFIED BY THE CONTRACTOR PRIOR
TO START WORK AND SHALL BE ADJUSTED BY CONTRACTOR TO FIT JOB
CONDITIONS. MEASUREMENTS TAKEN TO FACE OF EXISTING EXPOSED
WALLS AND NOT GUARANTEED TO BE ACCURATE ONCE THE WALL STUDS
ARE STRIPPED.
BEAMS SPECIFIED AS LVL SHALL MEET THE SPECIFICATIONS OF
GEORGIA-PACIFIC CORPORATION ENGINEERED LUMBER OR EQUAL:
MODULUS OF ELASTICITY = 2,000,000 PSI
SHEAR MODULUS OF ELASTICITY = 125,000 PSI
FLEXURAL STRESS = 2,900 PSI
HORIZONTAL SHEAR = 285 PSI
COMPRESSION PERPENDICULAR TO GRAIN = 845 PSI
COMPRESSION PARALLEL TO GRAIN = 2,600 PSI
EQUIVALENT SPECIFIC GRAVITY SG = 0.50
ALL POSTS SHALL BE 31
4X51
4 LVL POSTS EXTENDING TO FOUNDATION WALL
OR SUPPORT BEAMS AND SHALL HAVE THE FOLLOWING PROPERTIES:
BENDING STRESS = 2650 PSI
MODULA OF ELASTICITY = 1,900,000 PSI
COMPRESSION PERPENDICULAR TO GRAIN = 750 PSI
COMPRESSION PARALLEL TO GRAIN = 2350 PSI
SHEAR STRENGTH = 285 PSI
ALL LVL BEAMS SHALL HAVE A MIN OF 3" BEARING LENGTH.
ALL LVL BEAMS MADE OF 3 LVLS OR MORE SHALL BE BOLTED TOGETHER
AS REQUIRED BY LVL MANUFACTURER
ADD DOUBLE JOISTS UNDER ALL WALLS PARALLEL TO JOISTS
ALL WALLS PERPENDICULAR TO JOISTS SHALL HAVE SOLID BLOCKING
UNDER WALL
ALL HANGERS AND HARDWARE USED SHALL BE CORROSION PROTECTED.
BY REFERENCE THE 2021 IECC CODE IS PART OF THESE PLANS. ALL
FRAMING MUST COMPLY WITH THE REQUIREMENTS OF THE ENERGY CODE
TO ACHIEVE PROPER INSULATION. .
CONTRACTOR IS RESPONSIBLE FOR TEMPORARY SUPPORT DURING
CONSTRUCTION
UNLESS NOTED ON THE PLAN USE THE FOLLOWING HEADER SCHEDULE:
USE 2-2X6 HEADER FOR SPANS UP TO 3'-1"
USE 2-2X8 HEADER FOR SPANS UP TO 4'-2"
USE 2-2X10 HEADER FOR SPANS UP TO 5'-3"
USE 2-2X12 HEADER FOR SPANS UP TO 6'-0"
OVER 6'0" USE 2-13
4X71
4 LVL HEADER EXCEPT AS NOTED ON THE PLANS
USE 2 JACK STUDS AND 1 KING STUD EACH END OF HEADER OVER 5 FT
IT IS THE CONTRACTOR RESPONSIBILITY TO FOLLOW AND ENFORCE ALL
STATE AND FEDERAL LAWS AND REGULATIONS PERTAINING TO THIS
PROJECT INCLUDING OCCUPATIONAL SAFETY AND HEALTH REGULATIONS
AT ALL TIME DURING CONSTRUCTION
CONTRACTOR MUST OBTAIN ALL REQUIRED PERMITS PRIOR TO START OF
THE WORK
FRONT ELEVATION
SCALE: 1
4" =1'-0"
BACK ELEVATION
SCALE: 1
4" =1'-0"
SHEET 1 OF 4LEFT ELEVATION
SCALE: 1
4" =1'-0"
RIGHT ELEVATION
SCALE: 1
4" =1'-0"8.90'SECOND FLOOR
ELEV. 25.10
ELEV. 42.00
ELEV. 48.53 8.00'TOP PLATE
FIRST FLOOR
ELEV. 34.00
TOP RIDGE
6.53'24.59'ELEV. 23.94
APROX. GRND 1.16'
FC 7'2
FC 8'6
FC 7'2
KITCHEN
DINING
ROOM
CL
DN
BEDROOM
BEDROOM
BEDROOM
CL
CL
CL
CL
CL
CL
CL
LIVING
ROOM
BATH
BATH
EXISTING FIRST FLOOR PLAN
SCALE: 1
4" = 1'-0"
INDICATES WALL TO
BE DEMOLISHED
INDICATES PROPOSED WALL
INDICATES EXISTING WALL
KITCHEN
DINING
ROOM
BEDROOM #2
BEDROOM #1
OFFICE
CL
CL
CL
CL
CL
LIVING
ROOM
BATH #2
BATH #1
PROPOSED FIRST FLOOR PLAN
SCALE: 1
4" = 1'-0"8'-0"S
S
S
CO
CO
DN
UP 3'-6"CL
ADD 2-13
4X71
4 LVL
WINDOW HEADER
POST UP TO
RIDGE
FAMILY
ROOM
SECOND FLOOR PLAN
SCALE: 1
4" = 1'-0"
MASTER BEDROOM
BATH #3DRESSING ROOM
ROOF
ROOF
ROOF
ROOF
ROOF
MASTER CLOSET
17'-01 2"
D1
38'-4"
D1
14'-612"3'-1112"4'-512"8'-5"8'-312"31'-3"D1
5'-10"
3'-9"8'-3"5'-01 2"6'-0"3'-8"12'-9"3'-8"20'-1"INDICATES PROPOSED WALL
INDICATES EXISTING ROOF LINES
F
4'-11 2"
COMPOSITE DECKING
42" HIGH RAIL
S
S
CO
D3
W1 W1 W1
W2W2
W3W5
W5
W5 W5
W6
4'-71 2"4'-71 2"
BATH #4
D1
F5'-5"W4
DN
18'-51 2"
4'-71 2"4'-71 2"
3'-8"3'-6"3'-6"
3'-3"8'-61 2"8'-61 2"3'-3"
SECOND FLOOR ADDITION
AREA = 985 SF
3'-8"5'-31 2"4'-2"4'-01 2"
17'-2"
38'-4"
3'-0"
PELLA WINDOW ROUGH OPENING
W1
WINDOW S NOTES:
CONTRACTOR SHALL VERIFY ALL WINDOWS ROUGH OPENING WITH WINDOW
MANUFACTURER PRIOR TO START THE WORK
FOR WINDOW GRILLS CONSULT WITH OWNER
BEDROOM WINDOWS MEET THE FOLLOWING DIMENSIONS:
CLEAR OPENABLE AREA 3.3 SQ. FT.
CLEAR OPENABLE 20" X 24" ANY DIRECTION
E = EGRESS WINDOW
S = SAFETY GLASS
ALL WINDOWS AND PATIO DOORS SHALL HAVE A U FACTOR = 0.3
ALL WINDOWS ON SECOND FLOOR SHALL BE EQUIPPED WITH WINDOW
GUARDS OR WINDOW OPENING CONTROL DEVICES THAT COMPLY WITH ASTM
F2090-10.
W H
MASTER BEDROOM
LOCATION
3-0/5-0 351
2 591
2
MASTER CLOSET
BATH #3 2-8/4-0 311
2
BATH #4
3
NO.
W2
1W3
3-0/5-0 351
2 591
2 2
291
2 471
2FAMILY ROOM 4W5
REMARKS
471
2
3-2/5-0
DOUBLE HUNG
DOUBLE HUNG
DOUBLE HUNG
DOUBLE HUNG
DOUBLE HUNG
E
E
S
S311
2 471
2 1
3-0/5-0
351
2 471
2FAMILY ROOM 2W6 DOUBLE HUNG3-0/4-0
W4
F FAN VENTED TO THE
OUTSIDE
D1 INTERIOR DOOR 2'6"X6'8"
D2
D3 PATIO DOOR PELLA IN SWING 7580
SMOKE DETECTOR UL 217 OR UL
268
CARBON MONOXIDE AND SMOKE
DETECTOR UL 217 AND UL 2075
HEAT AND SMOKE UL 521 OR UL 539.
S
H
CO
ALL DETECTORS SHALL BE
INTERCONNECTED IN ACCORDANCE WITH
NFPA 720.
INTERIOR DOOR 2'8"X6'8" WITH
WEATHER STRIPPING8'-0"TOP PLATE
3-2X8 HEADER
SUB-FLOOR
TYPICAL SECOND FLOOR
WINDOW DETAIL CHECKED: SK DRAWN BY: AK ISSUED FORCONSTRUCTIONAPRIL 23, 2025PROJECT LOCATION38 INDIAN MEMORIAL DRIVESOUTH YARMOUTH, MA 026646CONTRACTORPROJECT TYPESECOND FLOOR ADDITIONRESIDENTIAL R-3PLANS PREPARED BYDESIGN BY SAMI LLC.81 OCEANSIDE DRIVESCITUATE, MA 02066APRIL 23, 2025
SHEET 2 OF 4
CRAWL
SPACE
BASEMENT
FOUNDATION PLAN
SCALE: 1
4" = 1'-0"
CRAWL
SPACE
12" DIA.
FOOTING WITH
BIGFOOT
9'-0"5'-912"S
9'-0"
BASEMENT
FIRST FLOOR FRAMING PLAN
SCALE: 1
4" = 1'-0"
CRAWL
SPACE
INFILL CHIMNEY
LOCATION MATCH
EXISTING JOISTS SIZE
BEAM #7
4-13
4X71
4 LVL
DN
UP
CL
KITCHEN
DINING
ROOM
BEDROOM
BEDROOM
OFFICE
CL
CL
CL
CL
CL
LIVING
ROOM
BATH
BATH
SECOND FLOOR FRAMING
SCALE: 1
4" = 1'-0"
DN
8'-01 2"3'-11"5'-71 2"
2X8 P.T. AT
16" O.C.
2X8 P.T. LEDGER BOARD BOLTED TO EXISTING
STRUCTURE AT WITH 1/2" DIA. BOLTS WITH
WASHERS STAGGERED AT 16" O.C.
3-2X10 P.T.
BEAM
5
4X6 COMPOSITE
DECKING
4X6 P.T. POST
(TYP.)
DOUBLE JOISTS
(TYP.)
RIM BOARD (TYP.)
RIM BOARD (TYP.)
BEAM #5
2-13
4X117
8 LVL
BEAM #6
2-13
4X117
8 LVL
BEAM #7
3-13
4X117
8 LVL
POST UP TO RIDGE
SECOND FLOOR FRAMING NOTES:
11
8" FIBERSTRONG® RIM BOARD
CONFORMING TO ANSI/APA PRR
410
SUB-FLOOR SHALL BE 3
4 T&G CDX
PLYWOOD NAILED AND GLUED TO
JOISTS.
DOUBLE JOISTS UNDER ALL WALLS
PARALLEL TO JOISTS
ADD SOLID BLOCKING UNDER ALL
WALLS PERPENDICULAR TO JOISTS
AJS 20, 117
8 JOISTS AT 16" O.C.AJS 140, 1178 JOISTS AT 16" O.C.DOUBLE
JOISTS (TYP.)
DOUBLE JOISTS
UNDER WALL
BEAM #4
3-13
4X71
4 LVL
FLUSH FRAMED
ADD 2-13
4X71
4 LVL
WINDOW HEADER
POST UP TO
RIDGE
BEAM #8
3-13
4X71
4 LVL
FLUSH FRAMEDEXISTING CEILING
JOIST (TYP.)
LIVING
ROOM
CEILING FRAMING PLAN
SCALE: 1
4" = 1'-0"
BEDROOM
BATHDRESSING ROOM
ROOF
ROOF
ROOF
ROOF
ROOF
CLOSET
BATH
BEAM #2
2-13
4X117
8 LVL
FLUSH FRAMED
14'-4"20'-1"2X8 @ 16" O.C. CEILING JOISTSBEAM #3
3-13
4X14 LVL
FLUSH FRAMED
BEARING WALL
EXISTING RAFTER
(TYP.)CHECKED: SK DRAWN BY: AK ISSUED FORCONSTRUCTIONAPRIL 23, 2025PROJECT LOCATION38 INDIAN MEMORIAL DRIVESOUTH YARMOUTH, MA 026646CONTRACTORPROJECT TYPESECOND FLOOR ADDITIONRESIDENTIAL R-3PLANS PREPARED BYDESIGN BY SAMI LLC.81 OCEANSIDE DRIVESCITUATE, MA 02066APRIL 23, 2025
SHEET 3 OF 4
LIVING
ROOM
ROOF FRAMING PLAN
SCALE: 1
4" = 1'-0"
ROOF
ROOF
ROOF
ROOF
BATH
TYPICAL ROOF CONSTRUCTION
2X12 CONTINUOUS RIDGE
2X10 ROOF RAFTERS @ 16" O.C.
5 8" CDX PLYWOOD SHEATHING WITH
AIR BARRIER ZIP SYSTEM, TAPED ALL
JOINTS OR EQUAL BUILDING PAPER
2X6 COLLAR TIES AT 48" O.C.
ASPHALT ROOF SHINGLES ON ICE
AND WATER SHIELD.
CONTINUOUS SOFIT AND RIDGE
VENTS.
ALL RAFTERS SHALL BE HUNG TO
THE RIDGE BEAM USING RAFTER
HANGERS
USE HURRICANE TIES TO ATTACH
RAFTERS TO TOP PLATE.
ROOF RAFTERS ARE DESIGNED FOR
FUTURE 5 PSF SOLAR PANELS
RIDGE BEAM #1
3-13
4X18 LVL
2X12 RIDGE
BEAM #3
3-13
4X71
4 LVL
DOOR HEADER
2X12 RIDGE
OVER FRAME (TYP.)
BEAM #2
2X12 RIDGE
OVER FRAME (TYP.)
METAL STEEL STRAPPING @ 48" O.C.
LSTA 30
2X12 JOISTS AT 16"
O.C.
SLOPED RAFTER HANGER
LSU
2X14 LVL RIDGE
ROOF SCHEMATIC DETAIL
NOT TO SCALE
BEAM #6
2-13
4X117
8 LVL
BEAM #5
2-13
4X117
8 LVL
RIDGE BEAM #1
3-13
4X18 LVL
8'-0"BATH #4
FAMILY
ROOM
4X6 P.T. POST
EPB46 OR SIMPSON
STRONG TIE
LIVING
ROOM DINING
ROOM
DECK
7
12 R60 INSULATION
R20 + R5 CI INSULATION
TYPICAL EXT. WALL CONSTRUCTION
2X6 STUDS @ 16" O.C.
1
2" CDX PLYWOOD SHEATHING
AIR BARRIER SYSTEM TAPED ALL JOINTS
R 30 INSULATION OR R 20 + R5 CI
SIDING AS DIRECTED BY OWNER
TYPICAL ROOF CONSTRUCTION
2X10 @ 16" O.C.
5 8" CDX PLYWOOD SHEATHING
TAPE ALL JOINTS
AIR BARRIER SYSTEM
ASPHALT ROOF SHINGLES
ON WATER AND ICE SHIELD
2X6 @ 16" O.C.
TYPICAL SECTION
SCALE: 1
4" = 1'-0"
HURRICANE TIE
H5 (TYP.)
3-2X10 P.T BEAM
2X8 @ 16"
O.C. JOISTS
5
4X6 DECKING 7" MAX. STEP
DOWN
AJS 20, 117
8 JOISTS AT 16" O.C. WITH
3
4" T&G CDX PLYWOOD SHEATHING
AND HARDWOOD FINISH
EXISTING ROOF
EXISTING CEILING
TO REMAIN
BASEMENT CRAWL SPACE
ATTENTION VERY IMPORTANT NAILS RING SHALL
BE FLUSH WITH THE SURFACE OF SHEATHING AND
SHALL NOT PENETRATE THE SURFACE OF THE
SHEATHING BY MORE THAN THE THICKNESS OF
THE NAIL RING 8.90'SECOND FLOOR
ELEV. 25.10
ELEV. 42.00
ELEV. 48.53 8.00'TOP PLATE
FIRST FLOOR
ELEV. 34.00
TOP RIDGE
6.53'24.59'ELEV. 23.94
APROX. GRND 1.16'BEAM #6 2-13
4X117
8 LVL
WINDOW DOOR WINDOW
3-13
4X71
4 LVL3-2X8 3-2X8
WINDOW WINDOW
MSTA
STRAPPING
4X6 POST
EXISTING FOUNDATION WALL
EXISTING
BOTTOM PLATE
EXISTING FLOOR
JOIST (TYP.)
EXISTING WALL
STUD (TYP.)
TYPICAL BEAM #6 ELEVATION
SCALE: 1
4" = 1'-0"
NOTE: USE SIMILAR DETAIL FOR BEAM #5
MSTA STRAPPING
@ 6'±
SHEATHING JOINT
MSTA SIMPSON
STRAPPING (TYP.)
A34 CLIPS OR
SIMILAR (TYP.)
POST
BEAM
BEAM TO COLUMN CONNECTION
SCHEMATIC DETAIL
NOT TO SCALE
519519
519519
519
519
519 519519 519519519519519DTT2Z SPACED AT @ 6FT O.C.
AND 12" FROM ANY CORNER
PROPOSED
STUD (TYP.)
EXISTING
STUD (TYP.)
EXISTING
TOP PLATE
BEAM OR RIM
BOARD
PROPOSED
SUBFLOOR
BOTTOM PLATE
STRAPPING AT 6±FT O.C. TO BE
INSTALLED AFTER ROOF IS
FRAMED AND COVERED WITH
SHINGLES
PROPOSED
SHEATHING
DTT2Z @
6FT O.C.
SCHEMATIC CONNECTION
DETAIL BETWEEN FLOORS
NOT TO SCALE
TYPICAL SHEATHING NAILING
TO JOISTS OR RAFTERS12" NAIL SPACINGJOINT BETWEEN
SHEATHING
3 4" T&G CDX PLYWOOD
SHEATHING RAFTERS
6" SPACING (TYP.)
8d COMMON NAIL
(TYP.)
ATTENTION VERY IMPORTANT NAILS RING SHALL
BE FLUSH WITH THE SURFACE OF SHEATHING AND
SHALL NOT PENETRATE THE SURFACE OF THE
SHEATHING BY MORE THAN THE THICKNESS OF
THE NAIL RING
FAMILY
ROOM
SECOND FLOOR WALL BRACING PLAN
MASTER
BEDROOM
BATH #3DRESSING
ROOM
MASTER
CLOSET
BATH #4 DN
INDICATES BRACE WALL LOCATION
TYPICAL WALL BRACING
SIMPSON RCWB 14 20-GAUGE
GALVANIZED STEEL WALL
BRACING SIMILAR
TOP PLATE
SOLID
BLOCKING
2-8d COMMON NAILS
PER STUD
SUB-FLOOR
BOTTOM
PLATE PLATE
2-8D COMMON NAILS
TOP PLATE AND
BOTTOM PLATE
60°CHECKED: SK DRAWN BY: AK ISSUED FORCONSTRUCTIONAPRIL 23, 2025PROJECT LOCATION38 INDIAN MEMORIAL DRIVESOUTH YARMOUTH, MA 026646CONTRACTORPROJECT TYPESECOND FLOOR ADDITIONRESIDENTIAL R-3PLANS PREPARED BYDESIGN BY SAMI LLC.81 OCEANSIDE DRIVESCITUATE, MA 02066APRIL 23, 2025
SHEET 4 OF 4