HomeMy WebLinkAbout5185 78 Indian Memorial Dr Plot Plan 06.08.25NOTES: 1. INFORMATION SHOWN ON THIS PLAN 15 THE RESULT OF A FIELD SURVEY PERFORMED BY SPRUHAN ENGINEERING, P.C. AS OF 06/04/2025, 2. DEED REFERENCE: BOOK 17709, PACE 266 PLAN REFERENCE 1: PLAN BOOK 80, PG 21 PLAN REFERENCE 2: PLAN BOOK 77. PG 95 PLAN REFERENCE M PLAN BOOK 83. PG 13 PLAN REFERENCE 4: PLAN BOOK 149. PG 129 PLAN REFERENCE 5: PLAN BOOK 651. PC 47 BARNSTABLE COUNTY REGISTRY OF DEEDS 3. THIS PLAN IS NOT IRTENDEO TO BE RECORDED. 4. 1 CERTIFY THAT THE DWELLING SHOWN IS NOT LOCATED WITHIN A SPECIAL FLOOD HAZARD ZONE. IT IS LOCATED IN ZONE X, ON FLOOD HAZARD BOUNDARY MAP NUMBER 25001CO587J. IN COMMUNITY NUMBER: 250015. DATED 7/16/2014. S. THIS PLAN DOES NOT SHOW ANY UNRECORDED OR UNWRITTEN EASEMENTS WHICH MAY EXIST. A REASONABLE AND DILIGENT ATTEMPT HAS BEEN MADE TO OBSERVE ANY APPARENT USES OF THE LAND; HOWEVER THIS NOT CONSTITUTE A GUARANTEE THAT NO SUCH EASEMENTS EXIST. 6. FIRST FLOOR ELEVATIONS ARE TAKEN AT THRESHOLD. 7. NO RESPON961UTY IS TAKEN FOR ZONING TABLE AS SPRUHAN ENGINEERING, P.C. ARE NOT ZONING EXPERTS. TABLE IS TAKEN FROM TABLE PROVIDED BY LOCAL ZONING ORDINANCE CLIENT AND/OR ARCHITECT TO VERIFY THE ACCURACY OF ZONING ANALYSIS. & THE ELEVATIONS SHOWN ARE ON AN ASSUMED DATUM. 9. ZONING DISTRICT R-40 LEGEND E) BOUND 0 IRON PIN/PIPE O STONE POST TREE TREE STUMP SHRUBS/FLOWERS SIGN a BOLLARD ® SEWER MANHOLE ® DRAIN MANHOLE ® CATCH BASIN ® WATER MANHOLE WATER VALVE HYDRANT t GAS VALVE ® ELECTRIC MANHOLE (6j ELECTRIC NANDHOLE UTR.NY POLE LIGHT POLE ® MANHOLE X SPOT GRADE TOP OF WALL BOTTOM OF WALL EXISTING BUILDING RETANING WALL STONE WALL FENCE TREE LINE SEWER LINE DRAIN LINE WATER LINE GAS LINE UNDERGROUND ELECTRIC LINE pHw OVERHEAD WARES �145� CONTOUR LINE (MJR) CONTOUR LINE (MAR) GRAPHIC SCALE M man . L5 n EXISTING PROFILE NOT TO SCALE I Spruhan Engineering, P. C. 60XWETT$T, ($1NFE 1! NEWTON. MA 02456 Tel 617.6 U 6 0722 Emad:Comwd�W l�nekJ .�sn 78 INDIAN MEMORIAL DRIVE, YARMO UTH MASSACHUSETTS SURVEY PLAN III REVISION BLOCK A11 legal rights including, but not limited to. copyright and design potent rights, in the designs, arrangements and plans shown on this document are the property of Spruhan Engineering, P.C. They may not be used or reused in whale or "n part, except in connection with this project, without the prior written consent of Spruhan Engineering, P.C.. Written dimensions on these drawings sho have precedence over scaled dimensions. EXISTING ROOF PEAK Contractors shall verify and be responsible EXISTIN 1 ROOF for all dimensions and conditions on this project, and Spruhan Erifneering, P.C., must be noUlied of any variation from the dimensions and conditions shown by these �� ar IMSHED FLOOR 0r"� .61 t 00 AT STREET FRONT 4 PLOT PLAN OF LAND F*1621 010=012a