HomeMy WebLinkAboutsystem inspection report 2009RALPH I. PERRV 'NC.96 Falmouth Rd. (Houte 28) . Hyannis, MA 02601 . Phone: (508) 775-FIRE . MA. LlC. #017 D.O.T # 4-850 SYSTEM INSPECTION REPORT 10i330 \amr ,L:1*C{v1 l/ j42:t,^-+ll tt 'tj /. fl Model # V 6'){d ofTank Date Q-oa eq Next Insp. c), S- G,flt)/'(6 Address ri Cr {f-/'Dry BillTo Contact D.t NN. .:.(g inspection Heary Annual CO2 Cartridge Fusible Linls: 360 J 450- other Fuel shur off t /.7 Gas \/- Electric Semi \.'/ Recharge- New- tlood Filters need to be cl Cooking appliance location: Left to right: Modemte Type r(Pans replaced Ralph J. Perr],, Inc. must be notified ifthere is any change/movemenl in cooking equipment l. 2. 3. 4. 5. 6. 't. 8. 9. 10. lt. 12. 13. 14. t5. t6. Are all appliances covered by nozles Are hood and ducl covered by nozzles Check positioning of nozzles Hood and duct p€netrations sealed Is system U.L. 300 Proper cleaiance flame to filters Nozzle seals in place Are there seal tites in place Pressure gauges in proper rarge Check cartridge weighl Hydrotest due Inspect cylinder liquid and mount Test for proper operation fiom terminal link Test remote manual operation Micro switch in place Cas valvc in placc and working L,.'---- t--- u.-' 11. 18. 19. 20. 21. 22. 23. 24. 25. 26. 2',7. 28. 29 30 Clean nozzles no. of/ duct,/ olenurn '{ aooliance Replace tusible linksi M fg date' .) C(ry ' ' Check cable, nut, a.nd S-hook movement AII piphg secured All filters in place CartridgeAl2 reinstai led/Safety pin removed System reset and operational AIIyellow seals in place Service and certificalion tag on system Portable eninguishers up to code Class K extinguisher and placard installed Reviewed automatic & manual operation ofsvstem customer Exhaust fan working Customer instructcd on required monthly insFection ofsystem Customer performing monthly inspection * L.-L"' lz'L--.w,-_J2_L-' L.?,-' eeFi L-- Li"L--' l_.--' L-/- \-" V./- L-- Lz/' ll Recommendation Non-compliance issued: Yes / No Reasotr *Non-Complianoe systems/or systems with discrePancies may fail to extitrguish/supPrcss a ftre. Ralph J. perry, Inc. is not a hood/duct servicc company. Any discrcpancies should b€ addressed by a qualified hood/duct company Extinguisher Inspections: - Light InsPections RECHARGES / SERVICE Drychem 2.51b.- 5lb.- 10lb- 20lb- 6year- Hydro- Drychem PW Tolal # of Ext:-Ext. due service: NEW EXTINGUISEI'RS 2.stb. _ slb._ rolb._ 201b. K Class-6l-- 2.5G- Hydro- PW- K Class -6L- 25G Halotron 2.51b.- 5lb. -l I lb.- l5.5lb.- 6 year-Hydro- Halotron 2.51b. -51b. - lllb. - 15.51b. CO2 5lb.- I Olb-l5lb-201b.-Hydro -- CO2 5lb. - l0lb.- lslb. - 201b. Parts: Service Collar Oring - Pull Pin Batteries: FIRE EXTINGUISHERS ARE IN COMPLIANCE WTIH NFPA I O CODE \TS !-./- NO Bulbs- Misc C ji c37 Service Technician Lic. #Customer's Authorized Represetrtative P-tiaii .ead r],e Crstomer Ackno\rladgmenr on r.verse side hefore srgnine and was operating accoraling to these Procedwcs with the results indicated above indicated above.n" uto"a ,"*i"a ,*r,nician certifies that thc systcfi/€xtiflguishels werc personally inspcct€d and found conditions to be as indicated above' A copy ofthis rcpofl will be forwardcd ro tbe local fiI! departsnent' Mfg. Nozzle Seals I Grease accumulation: Discrepamies or defi cienci€s ,-)