Loading...
HomeMy WebLinkAbouttest of fire alarm system 2001Dennis E. Brown Chief of Department SUBJECT:Test of Fire Alarm Systems DATE:February 2001 In 1979 the Town of Yarmouth adopted section 26c ofchapter l4g of the Massachusetts General Laws. This law mandated the installation of fire alarm systems. It is the responsibility of the owner to maintain and test these systems as required by section 1200.g.3 ana iz t o.:.2.sof the State Building code. These tests are further required by the code of Massachusetts Regulations chaptet 527 cMR Section 24.08. PLEASE coMpLETE THE FoLLowNG FORMS AND RETURN THEM TO THE YARMOUTH FIRX DEPARTMENT BY MAY 15, 2()OI, OR FURTHER ACTION WILL BE TAIGN BY THIS DEPARTMENT.. RETUR}i'ED. Name of Establishment Address 281 Main st.lIest Ya rmou t Ma.4267 3 Telephone Number(s) Section of Town s08-826-1626 Street Zip Code Manager's Name James LoDES Manager's Address 281 Main St., West yarmouth, Ma. OZ6j3 , -a /s/"t FROM: Street City or Town Zip Code Telephone Number_____gt B-R)6- t ^1^ Were any structural changes or alterations made in 2000? _yes x No l, Zones on panel must be labeled with room numbers or area of the building i.e. Rooms 100-200 or south wing. 2. A copy of the floor plan of the building(s) must be posted at the fire alarm panel, and onereturned with this form. Copy previously submitted yes No /. lr ,' '' / ,'/'r '"'-;:'t,'- FIRE ALAR}I TEST REPORT 1750 HouseName of Premi 281 Main St., West yarmouth, Ma. 02673Address Telephone Number 508 -826-1626 Control Panel Located A Conrol Panel Amunciator Stand-by Battery Smoke Detectors Heat Detectors Pull Stations Bells/Homs Sprinkler Tamper Switch _ok x_ok x_ok _ok _ok ok ok Service Date 4-20-01 4-20-O1 _ok REOUIRED FREQUINCY OF TESTS ON BACK OF SHEET Service Commen l( James Lo CS e inspecte 1 smoke d etect or s on--Q4 - 2-0 -OLand the above tested items are working according to manufacturer's recommendations. Company Name and Snuffy Realty Trust 281 Main St., west Yarmouth, Ma. 02673 rl al Received Yarmouth Fire Departmen t (ovER) _ok SMOKE DETECTORS: Must be tested annually. IIEAT DETECToRS: Restorable spot type, one detector on each circuit shall be tested semi-annually. Different detector shall be selected for each test. Non-restorable spot t)?e, after 5'h year, at least two detectors out of every hundred or fractionthereof' shall be removed every 5 years and sent to a nationally recognized testing laboratory fortests. Detectors removed for test shall be replaced with new detectors. If failure -occurs on anyof the detectors removed, additional detectors shall be removed and tested as a further check tocomply with CMR 527 Sec.24.08. LINE TYPE FIXED TEMPERATURE DETECToRS: Loop resistance semi-annuaily andposted in panel. PULL STATIONS: All pull stations shall be tested annually. BATTERY BACK UP: Shall be tested semi-annually. TROUBLE OVERRIDE TEST: Shall be tested annually. SPRTNKLER: Shall be tested at main drain semi-annually through to fire department. \OTE: All additions or deletions of equipment shall be reported to the fire department immediately ALAP.TII TESTS.