HomeMy WebLinkAboutfire alarm inspection report 2009Ga/e, Gad,4/an rru G*., 9no eol Old.%oanlotqz fraad Eliao, ga.r*oel/4 JbtaaaA4aalA, o e a f ,c ALARM INSPBCTION REPORT Occupancy: WindsorSkilledNursing 265 North Main Street South Yarmouth , MA 02664 Site Contact: John Gray Telephone (508)394-35 l4 Alarm System is a (X) Fire System ( ) Security System Alarm System Reports to (X) Cape Cod Alarm Co., Inc. ( ) Other: Local The Alarm System at the above location was tested, and all parts ofthe above system were found to be, or conected to be operational, Comments: Date Tested; 10113109 Bv: Thomas Lese\.t signr,rr., A-/"N- MA Contractors License # 1592C *lnsnllinq, Senvicinq end Monironinq o[ Srcuniry, Finr, nnd CCTV Sysrrms* lro8l r98.6fl6 " (800) 468,8100 Fnx: Officr (r08l 198.1666 * Fnx: Crrrnnl Srnrion (t0B)760,2012 MA Licrnsr No. lI92C Inspection and Testing Ileport Property: Windsor Nursing Home Transmission Type: ( ) Mcculloh ( ) Multiplex (X) Digital ( ) Reverse Polarity ORT( ) Master Box _ Qty of t2 Inspection Schedule ( ) Weekly ( ) Monthly (X) Quarterly( ) Semi-Annually Other: Annuall() Panel Manufacture: Firelite Location: Boiler room Number of Circuits: Addressable Last date system had any service performed: 10/13109 Last date that any software or configuration was revised Alarm Initiating Devices and Circuit Information Model Number: MS 9200UD Circuit Styles: Addressable Software Rev.: Manual Stations Ion Detectors Photo Detectors Duct Detectors Heat Detectors Water flow Switches Supewisory Switches Other: Ansul system Comments N/A 45 Circuit Styte Addressable _Addressable, _Addressable_ _Addressable_ _Addressable- _Addressable_ _Addressable_ Pass I I I Transient Suppressors Remote Annunciators Notifi cation Appliances Audible Visual Speakers Voice Clarity () (x) (x) (x) cx)() () Fail () () () () () () () N/A_ N/A I l Inspection and Testing Report Property: Windsor Nursing Home Initiating and Supervisory Device Tested and Inspections Loc. & SA,l Device Visual Functional FactoryType Check Check Setting nkler Rm Water flow (X) (X)IA Sprinliler Rm Tamper (x) (x)(x) (x) N/A N/A Meas. Setting -N/A- -N/A_N/A (x) (x) (x) () () ()Boiler Rm Heat Det. Ansul Switch - Tested b1, others oke Detectors - See attached Detector Sensitivity Report. Emergency Communications Equipment ual Funclional Phone Set Phone Jacks Off Hook Indicator Amplifier Tone Generator Call In Signal System Performance S CommentsN/A_ N/A N/A N/A N/A N/A () () () () () () () ) ) ) ) ) ) ) ( ( ( ( ( ( ( Interface EquipmentVisual Functional Simulated Operation Specifo _N/A Specifo _N/A Specifr _N/A_ Specify _N/A Special Hazard Systems() ( )() ( )Specifo _N/A Secondary (Stand-by) Battery _2_ Storage Battery: Amp-Hr Rating _12_ Calculated Calculated capacity to operate system in hours:_ 24 _ 60 _ Engine -driven Generator Dedicated to Fire Alarm System: Location of Fuel Storage: () () () () () () ) ) ) ( ( ( () () Type of Battery( ) dry cell( ) nickel cadium (X) sealed lead acid( ) lead acid ( ) other Pass Fail Inspection and Testing Report Property: Windsor Nursing Home Emergency or standby system used as a backup to primary power supply, instead ofusing a secondary power supply: ( ) Emergency system described inNFPA 70, article 700 (X) Legally required standby described in NFPA 70, article 701( ) Operational standby system described in NFPA 70, article 702, which also meets the performance requirements ofarticle 700 or 701. Prior to Testing Notifications Are lvlade Monitoring Entity Building Occupants Building Management Other: AHJ notified of any impairments Control Panel Interface Equipment Lamps/LED's Fuses Primary Power Supply Trouble Signals Disconnect Switches Ground Fault Monitoring Secondary Power Battery Condition Load Voltage Discharge Test Charger Test Specific Gravity Bells Horns no System Tests & Inspections yes (x) (x) (x) () () ) ) ) ) ) ( ( ( (x Visual Functionalcx) (x)cx) (x)(x) (x)(x) (x)(N/A) (X)00 (x)(N/A) (N/A)(x) (x)(x) (x)(x) (x)(N/A) (x)(N/A) (x)(N/A) (x) () () Comments Alarm Indicating Appliances and Circuit Information Qfy of Circuit Style Qty ofStrobes 3 Speakers Hom/Strobes 1 N/A Circuit Style Class B Class B Number of indicating circuits: 2 Are circuits supervised? (X) yes ( ) no Chime/Strobes 12 _Class B_ Inspection and Testing Report Property: Windsor Nursing Home Supervisory Signal Initiating Devices and Circuit Information Qty Circuit Style Building Temp. N/A N/A Site Water Temp N/A N/A Site Water Level _N/A_ _N/A_ Fire Pump Power _N/A_ _N/A_ Fire Pump Running N/A N/A Fire Pump Auto Position Nla- N/A Fire Pump/Pump Controller Trbl. N/A N/A Ceneraroi ln Auto Posirion -N/A N/A Switch Transfer -N/A- -N/A-Cenerator Engine Running Nla N/AOther -N/A- -N/A- Signaling Line Circuits Quantity and style (see NFPA 72, table 3-6.1) ofsignaling line circuits connected to N/A Location (panel no.)Boiler Room I-abeled: BMPB Disconnecting Means Location: Special Procedures: _None_ Comments: On/Off Premises MonitoringYes No Alann Signal (X ) ( ) Supervisory Signal Alarm Restoral (X ) ( ) Supervisory Restoral Trouble Signal (X ) ( ) Notifications That Testing Is Complete Yes No Yes Building Management CX) ( ) Building Occupanrs (X ) Monitoring Agency (X) ( ) other (specify) ( ) Yes cx)(x) No ()() No () () System Returned to normal operation on l0/13/09 at ll:15 system: Qty. _N/A_ Style(s) Stem Power Supplies Primary (main): Nominal Voltage _110v Amps _20_ Overcurrent Protection: Type _Circuit Breaker , Amps 20_ None The following did not operate corectly: