HomeMy WebLinkAbout2025 FIRE ALARM INSPECTION BUILDING REPORT2025 Captain Parker's Pub 668 Main Street West Yarmouth, MA 02673 (508)771-4266 Building Contact:Gerry Manning Title:Contact Company:Cape Cod Alarm Contact:Chad Benaka Title:Service Tech Fire Alarm Systems INSPECTIONCERTIFICATE Sep 2, 2025Inspection Date: Tested to NFPA 72 Standards This Inspection was performed in accordance with applicable NFPA Standards. The subsequent pages of this report provide performance measurements, listed ranges of acceptable results, and complete documentation of the inspection. Whenever discrepancies exist between acceptable performance standards and actual test results, notes and/or recommended solutions have been proposed or provided for immediate review and approval. Page of 1 9 Executive Summary Cape Cod Alarm Download Date: 09/04/2025 EXECUTIVE SUMMARY Generated by: BuildingReports.com Building Information Captain Parker's Pub 668 Main Street West Yarmouth, MA 02673 United States of America Contact: Gerry Manning Phone: (508)771-4266 Fax: Mobile: Email: Inspection Performed By Cape Cod Alarm204 Old Townhouse RoadWest Yarmouth, MA 02673United States of America Inspector: Chad Benaka Phone: (508)398-6316 Fax: Mobile: Email: service@capecodalarm.com System Control Unit Manufacturer: Fire-Lite Inspection Date: 09/02/2025 IDC Style: E Model Number: MS-10UD Install Date: 04/10/2024 SLC Style: N/A Software Version:Version Date: 12/31/1969 NAC Style: E Location: 1st Floor Bar Area by Side Exit Disconnect Location:Disconnect Type: Current Protection: Breaker Monitoring Company: Cape Cod Alarm Phone: (508)398-6316 Account #: S28638 Central Station Signal Verification Type: Mesh Radio Network Mfg: AES Model #: 7788F Test Time/Date: 9/2/25 8:05:47 AM Restore Time: 9:00 AM Note: Type of Signal Signal Confirmed Time Notes Alarm Signal 8:11 AM Trouble Signal 7:59 AM Page of 2 9 Executive Summary Cape Cod Alarm Download Date: 09/04/2025 Building: Captain Parker's Pub Contact: Gerry Manning Company: Cape Cod Alarm Inspector: Chad Benaka Inspection Summary Category Total Items Serviced Passed Failed/Other Qty %Qty %Qty %Qty % Alarm 2 3.85%2 100.00%2 100.00%0 0.00% Control 5 9.62%5 100.00%5 100.00%0 0.00% Indicating 19 36.54%19 100.00%19 100.00%0 0.00% Initiating 24 46.15%24 100.00%24 100.00%0 0.00% Monitor 2 3.85%2 100.00%2 100.00%0 0.00% Totals 52 100%52 100.00%52 100.00%0 0.00% Certification Page of 3 9 Inspection & Testing Cape Cod Alarm Download Date: 09/04/2025 Control Panel: 1 - Fire-Lite MS-10UDBuilding: Captain Parker's Pub INSPECTION & TESTING Generated by: BuildingReports.com The Inspection & Testing section lists all of the items inspected in your building. Items are grouped by Passed or Failed/Other . Items are listed by Category. Each item includes the services performed, and the time & date at which testing occurred. Device Type Location Service Time Date PASSED Alarm Kitchen Hood 1st Floor Kitchen by Sink Area Tested 8:34:08 AM 09/02/2025 Kitchen Hood 1st Floor Kitchen by Waitress Prep Area Tested 8:33:57 AM 09/02/2025 Control Battery in Fire Alarm Control Panel Tested 8:01:14 AM 09/02/2025 Battery in Fire Alarm Control Panel Tested 8:01:23 AM 09/02/2025 Battery Attic in AES Transmitter Tested 8:37:12 AM 09/02/2025 Communicator Attic hatch in Office Tested 8:05:47 AM 09/02/2025 Control Panel 1st Floor Bar Area by Side Exit Tested 8:24:31 AM 09/02/2025 Indicating Horn/Strobe 1st Floor Bar Area in Corner Tested 8:14:02 AM 09/02/2025 Horn/Strobe 1st Floor Dining Room Tested 8:36:54 AM 09/02/2025 Horn/Strobe 1st Floor Kitchen Tested 8:36:51 AM 09/02/2025 Horn/Strobe 1st Floor Kitchen on Cooking Line Tested 8:36:45 AM 09/02/2025 Horn/Strobe 1st Floor Large Dining Room by Front Porch Tested 8:29:26 AM 09/02/2025 Horn/Strobe 1st Floor Left Side Entry Tested 7:59:50 AM 09/02/2025 Horn/Strobe 1st Floor Rear Kitchen Entry Tested 8:32:14 AM 09/02/2025 Horn/Strobe 1st Floor Right Side by Waitress Area Tested 8:00:31 AM 09/02/2025 Horn/Strobe 1st Floor New Section Left Side Entry Tested 8:30:22 AM 09/02/2025 Horn/Strobe 1st Floor New Section Right Side Entry Tested 8:30:01 AM 09/02/2025 Page of 4 9 Inspection & Testing Cape Cod Alarm Download Date: 09/04/2025 Device Type Location Service Time Date PASSED (continued) Indicating (continued) Horn/Strobe 1st Floor New Section Waitress Prep Area Tested 8:39:47 AM 09/02/2025 Horn/Strobe 2nd Floor by Water Heaters Tested 8:03:23 AM 09/02/2025 Horn/Strobe Basement by Hatch Tested 8:21:36 AM 09/02/2025 Strobe 1st Floor Men’s Restroom Tested 8:31:30 AM 09/02/2025 Strobe 1st Floor Unisex Restroom Tested 8:31:41 AM 09/02/2025 Strobe 1st Floor Women’s Restroom Tested 8:31:49 AM 09/02/2025 Strobe 1st Floor New Section Restroom Tested 8:30:44 AM 09/02/2025 Strobe 2nd Floor Restroom Tested 8:36:57 AM 09/02/2025 Strobe Outside Front of Building Tested 8:24:32 AM 09/02/2025 Initiating Heat Detector 1st Floor Kitchen Rear Prep Area Tested 8:39:08 AM 09/02/2025 Heat Detector 1st Floor Kitchen above Prep Line Tested 8:37:38 AM 09/02/2025 Heat Detector 1st Floor Kitchen by Stairs to 2nd Floor Tested 8:38:39 AM 09/02/2025 Heat Detector 1st Floor New Section Waitress Prep Area Tested 8:39:42 AM 09/02/2025 Heat Detector Basement Front Tested 8:23:11 AM 09/02/2025 Heat Detector Basement Front by Hatch Tested 8:23:37 AM 09/02/2025 Heat Detector Basement Middle Tested 8:23:07 AM 09/02/2025 Heat Detector Basement Rear Tested 8:23:02 AM 09/02/2025 Pull Station 1st Floor Large Dining Room by Front Porch Tested 8:29:22 AM 09/02/2025 Pull Station 1st Floor Left Side Entry Tested 8:13:48 AM 09/02/2025 Pull Station 1st Floor Main Front Entry Tested 8:28:44 AM 09/02/2025 Pull Station 1st Floor Rear Kitchen Entry Tested 8:32:16 AM 09/02/2025 Pull Station 1st Floor New Section Left Side Entry Tested 8:30:27 AM 09/02/2025 Pull Station 1st Floor New Section Right Side Entry Tested 8:29:59 AM 09/02/2025 Pull Station Basement by Hatch Tested 8:21:39 AM 09/02/2025 Page of 5 9 Inspection & Testing Cape Cod Alarm Download Date: 09/04/2025 Device Type Location Service Time Date PASSED (continued) Initiating (continued) Smoke Detector 1st Floor Bar Area Front by Fire Alarm Control Panel Tested 8:40:35 AM 09/02/2025 Smoke Detector 1st Floor Bar Area in Corner Tested 8:14:09 AM 09/02/2025 Smoke Detector 1st Floor Front Entry Up High Tested 8:24:35 AM 09/02/2025 Smoke Detector 1st Floor Right Side by Waitress Area Tested 8:00:34 AM 09/02/2025 Smoke Detector 1st Floor New Section Bar Area Tested 8:30:28 AM 09/02/2025 Smoke Detector 1st Floor New Section Dining Area Front Tested 8:40:26 AM 09/02/2025 Smoke Detector 1st Floor New Section Dining Area Rear Tested 8:40:30 AM 09/02/2025 Smoke Detector 2nd Floor at top of Stairs Tested 8:03:14 AM 09/02/2025 Smoke Detector 2nd Floor by Water Heaters Tested 8:03:21 AM 09/02/2025 Monitor Monitoring Alarm Signal Tested 8:05:45 AM 09/02/2025 Monitoring Trouble Signal Tested 8:05:43 AM 09/02/2025 Page of 6 9 Service Summary Cape Cod Alarm Download Date: 09/04/2025 SERVICE SUMMARY Generated by: BuildingReports.com The Service Summary section provides an overview of the services performed in this report. Building: Captain Parker's Pub Device Type Service Quantity PASSED Battery Tested 3 Communicator Tested 1 Control Panel Tested 1 Heat Detector Tested 8 Horn/Strobe Tested 13 Kitchen Hood Tested 2 Monitoring Tested 2 Pull Station Tested 7 Smoke Detector Tested 9 Strobe Tested 6 Total 52 Grand Total 52 Page of 7 9 Battery & Power Supply Testing Cape Cod Alarm Download Date: 09/04/2025 Control Panel: 1 - Fire-Lite MS-10UDBuilding: Captain Parker's Pub BATTERY & POWER SUPPLY TESTING Generated by: BuildingReports.com The Battery & Power Supply Testing section details the readings and measurements of batteries and power supplies used to provide power to the fire alarm and life safety systems. Items are grouped by Passed or Failed/Other. Battery Type Location Rated Ah Rated Volts Pre Test Post Test Min Ah Tested Ah PASSED Sealed Lead Acid in Fire Alarm Control Panel 7 12 100%90% Sealed Lead Acid in Fire Alarm Control Panel 7 12 100%90% Sealed Lead Acid Attic in AES Transmitter 7 12 100%100% Page of 8 9 Inventory & Warranty Report Cape Cod Alarm Download Date: 09/04/2025 Control Panel: 1 - Fire-Lite MS-10UDBuilding: Captain Parker's Pub INVENTORY & WARRANTY REPORT Generated by: BuildingReports.com The Inventory & Warranty Report lists each of the devices and items that are included in your Inspection Report. A complete inventory count by device type and category is provided. Items installed within the last 90 days, within the last year, and devices installed for two years or more are grouped together for easy reference. Building: Captain Parker's Pub Device or Type Category % of Inventory Quantity Battery Control 5.77%3 Communicator Control 1.92%1 Control Panel Control 1.92%1 Heat Detector Initiating 15.38%8 Horn/Strobe Indicating 25.00%13 Kitchen Hood Alarm 3.85%2 Monitoring Monitor 3.85%2 Pull Station Initiating 13.46%7 Smoke Detector Initiating 17.31%9 Strobe Indicating 11.54%6 Type Qty Model #Description Install Date IN SERVICE - 90 DAYS - 1 YEAR System Sensor Horn/Strobe 3 P2RL 09/10/2024 Horn/Strobe 9 P2RL-LF 09/10/2024 IN SERVICE - 1 YEAR TO 2 YEARS AES Communicator 1 7788F Mesh Radio Network 04/10/2024 Badger Page of 9 9 Inventory & Warranty Report Cape Cod Alarm Download Date: 09/04/2025 Type Qty Model #Description Install Date IN SERVICE - 1 YEAR TO 2 YEARS (continued) Badger (continued) Kitchen Hood 1 Ansul Trip (1)04/10/2024 Kitchen Hood 1 Ansul Trip (2)04/10/2024 Fire-Lite Control Panel 1 MS-10UD Conventional 04/10/2024 Pull Station 7 BG-12 Dual Action 04/10/2024 Power Patrol Battery 3 FAS1075 Sealed Lead Acid 04/10/2024 System Sensor Heat Detector 4 5601P Combination 04/10/2024 Heat Detector 4 5604 Fixed Temperature 04/10/2024 Horn/Strobe 1 P2RL-LF 04/10/2024 Smoke Detector 9 2151 04/10/2024 Strobe 1 SRK 09/04/2024 Strobe 4 SRL 04/10/2024 Strobe 1 SRLED 04/10/2024 IN SERVICE - 5 YEARS TO 10 YEARS (manufacturer not specified) Monitoring 1 Alarm Signal 02/10/2017 Monitoring 1 Trouble Signal 02/10/2017