Loading...
HomeMy WebLinkAbout47 Union Street inspection reportTown of Yarmouth, MA Inspection Report Inspection: Inspection Inspector: Debra Bruinooge Inspection Date: Sep 30, 2025 Record: Rental Registration #BHR-25-3 Location: 47 UNION ST, YARMOUTH PORT, MA 02675 Applicant: Irina Tenenbaum Rental Inspection Overall Result: Pass Overall Remarks: Met with owner's representative Deb Lippard and tenant Steve. Home was found overall neat and organized. Yard maintenance which was noted on the 2023 inspection report has been significantly improved. Pool gates were locked with proper signage. See below for findings. Checklist: 1. Number of Bedrooms/Measurements Result: Pass Remarks: #1 11.715 X 11.590, #2 11.685 X 11.525, #3 11.895 X 12.170, #4 8.900 X 11.895, #5 11.567 X 11.175 2. Maximum Occupancy: Based on septic system capacity, number of bedrooms and bedroom square footage Result: Pass Remarks: 550 GPD/5 Bedrooms-Maximum Occupancy-10 3. Basement Result: Pass Remarks: Unfinished 4. Electrical Panel Result: Pass 5. Copy of Tenant's Legal Rights have been issued to tenant. Result: Pass 105CMR 410.00 0Minimum Standards of Fitness for Human Habitation (State Sanitary Code: Chapter II) Result: Pass 410.100 Kitchen Facilities * Result: Pass 410.110 Bathroom Facilities : Sinks, Toilets, Tubs & Showers * Result: Pass Remarks: One of the bathrooms wasn't being utilized because of a leak that was going to the basement causing pooling water. Owner's representative said it has been repaired and dried and she will send photos for follow-up 410.120 Approved Toilets * Result: Pass 410.130 Water supply Potable Water/Sanitary Drainage Result: Pass 410.140 Plumbing Connections * Result: Pass 410.150 Hot Water 110-130 °F for faucets & 110-120 °F for bathtubs a & showers Result: Pass 410.160 Heating Systems * Result: Pass 410.170 Venting * Result: Pass 410.180 Temperature Requirements Owner shall proved heat in every habitable room & every room containing a toilet, shower or bathtub from September 15th through May 31st. 64° from 11:01 pm to 6:59 am 68° from 7 am to 11:00 pm Result: Pass 410.200 Provision and Metering of Electrical or Gas * Result: Pass 410.210 Provision of Oil * Result: Not Observed 410.220 Natural and Mechanical Ventilation * Result: Pass 410.230 Owner's Laundering Responsibilities If owner provides bed linens, towels, pillows or mattress Result: Not Observed 410.235 Owner's Installation, Maintenance and Repair Responsibilities * Result: Fail Remarks: -Pneumatic closer missing on storm door-replace The owner shall ensure proper installation, in compliance with accepted standards, and shall maintain in operable condition free from leaks, obstructions or other defects, all facilities and equipment which the owner is required to provide, and all owner installed equipment 410.240 Occupant's Installation and Maintenance Responsibilities * Result: Pass Remarks: The pool cover had blown off during a storm and will be re- secured. (The owner's representative will send a photo when complete) 410.250 Asbestos-containing Material * Result: Pass 410.260 Means of Egress * Result: Pass 410.270 Locks * Result: Pass 410.300 Electrical Supply & Illumination * Result: Pass 410.310 Auxiliary Emergency Lighting Systems & Exit Signs For properties with 10 or more units Result: Not Observed 410.320 Electrical Service Temporary Wiring, Amperage Result: Pass 410.330 Smoke Detector and Carbon Monoxide Alarms * Result: Pass Remarks: Present as required. Tested and working. (Tenant changed the batteries of a beeping ones) 410.400 Owner/Manager Contact Information and Notice of Occupants' Legal Rights and Responsibilities Contact information and postings inside and outside of home Result: Pass 410.410 Building Identification * Result: Pass 410.420 Habitability Requirements Result: Pass 410.430 Natural Light and Obstructions * Result: Pass 410.470 Lead-based Paint Hazards in Residence * Result: Pass 410.500 Owner Responsibility to Maintain Building & Structural Elements * Result: Pass Remarks: There is an active leak running into the basement, spoke with owner's representative who said she would reach out to have it repaired and the basement dried. See also 410.110 (A) Every owner of a residence shall maintain all buildings and structural elements in compliance with accepted standards so they are in good repair and in every way fit for the intended use, including: (1) Protected from wind, rain and snow, and are watertight, free from excess moisture or the appearance of mold, and pest resistant; and (2) Free from holes, cracks, loose plaster, or defects that render the area difficult to keep clean, create an injury risk, or provide an entry or harborage for pests. (B) In the event of leaks and flooding, the owner shall ensure all surfaces have been dried within 48 hours from the time they are notified or the end of the event, whichever is sooner. (I spoke to the owner's representative on 10/17/2025 who said it has been repaired and dried and she would send me pictures-see attached) I have updated this section from fail to pass 410.510 Occupant 's Responsibility Regarding Building and Structural Elements * Result: Pass 410.520 Protective Railings and Walls * Result: Pass 410.530 Weather-tight elements * Result: Pass 410.540 Installation of Screens * Result: Pass 410.550 Elimination of Pests Owners & Occupants are responsible for the control & elimination of pests Result: Pass Remarks: None observed 410.560 Refuse * Result: Pass Remarks: Tenant responsible 410.570 Maintenance of Areas in a Sanitary and Safe Condition * Result: Pass 410.620 Conduct of Inspections The need for an additional inspection by a specialized inspector pursuant to 105 CMR 410.620(A) and the reason that such inspection is necessary Result: Not Observed 410.630 Conditions Deemed to Endanger or Materially Impair Health and Safety One or more of the violations cited on this report may materially impair the health or safety and/or well-being of any person(s) occupying the premises Result: Not Observed 780 CMR 111.5.1 Posting of Use & Occupancy STR Only Result: Not Observed 780 CMR 111.5.2 Required Egress posting STR Only Result: Not Observed 780 CMR Means of Egress STR Only Result: Not Observed 780 CMR R314 & R315 Smoke/CO/Heat STR Only Result: Not Observed This inspection report is signed and certified under the pains and penalties of perjury. Inspector's signature, date and time Result: Pass Remarks: Debra Bruinooge-09/30/2025-10/17/2025-11:00AM