HomeMy WebLinkAboutSite Plan 9.25.2025P LAN VI EW 75' EXIST. LANDSCAPE TIE RETAINING WALL (TO BE LICENCED) EXIST. FIXED PIER LIC. #3047 /_ DECK EL. 3.0' EXIST. ALONGSHORE ACCESS STEPS (BOTH SIDES, WITH SIGNAGE) I 508-362-4541 downcape.com O down cape d9ft 14eering, Inc. civil engineers land surveyors 939 Main Street (Rte 6A) YARMOUTHPORT MA 02575 RELOCATE EXISTING PILE (OR REMOVE & ADD NEW 12" PILING) REPLACE OUTER 2 FLOATS WITH (1) 17.5'x 8' FLOAT EXIST. 14'x 2.3' RAMP REMOVE EXIST. PILING, ADD NEW PILING FOR NEW FLOAT ATTACHMENT n I MHW EL. 2.5' MLW EL. —1.1' PROFILE VIEW Scale: 1"= 10' 0 5 10 15 20 25 FEET EXIST. 12'x 5' FLOAT (RETAIN) EXIST. FLOATS (2) (REPLACE WITH (1) 17.5'x 8' FLOAT) e� y R0il e i Knob Hill ou e BIB c QI a Locus r a 5 Er5 Eric oin oorin9 .c z Q 60 .c LOCUS MAP SCALE 1 "=2000'f ASSESSORS MAP 101 PARCEL 170 LOCUS IS WITHIN FEMA FLOOD ZONE AE (EL. 11) AND ZONE X (AREA OF MINIMAL FLOOD HAZARD) AS SHOWN ON COMMUNITY PANEL #25001 CO583J DATED 7/16/2014 1x6" iiI 2x4" 4'-0" DECKING 1" X 6" DECKING NOTCH 4X4 THRU SOLT TO DECK ELEV. 3.0' 1 /2" SPACING / 2X6 MHw EL. 2.5' • 10"0 DIAM. PT PILES 3/4"0 H.D. GALV. ® 2X6 BRACES TiRU BOLT (TYP) EACH BAY II� gill I 4' WIDE SECTION PIER SECTION DETAIL NTS OWNER OF RECORD JOURNEYS INVESTMENTS, LLC 142 HIGHLAND AVENUE WINCHESTER, MA 01890 NOTES 1. DATUM IS NAVD88 2. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO BE USED FOR LOT LINE STAKING OR ANY OTHER PURPOSE. 3. CONTRACTOR SHALL BE RESPONSIBLE FOR CALLING DIGSAFE (811) AND VERIFYING THE LOCATION OF ALL UNDERGROUND & OVERHEAD UTILITIES PRIOR TO COMMENCEMENT OF WORK. 4. NON—CCA TREATED AND/OR NON —LEACHING TREATED MATERIALS REQUIRED 5. SALT MARSH DETERMINED BY BLH ENVIRONMENTAL CONSULTING 12/12/24. 6. DISPLAY MIN, 6"X6" SIGN AT END OF PIER SHOWING DEP PERMIT NUMBER AND STREET ADDRESS VISIBLE 7. FLOATS, RAMP AND KAYAKS/DINGHIES TO BE STORED ON UPLAND OR CONTRACTORS YARD IN THE OFF --SEASON 8. ANY PIER LIGHTING SHALL BE MAX. 25 WATT AND DIRECTED DOWNWARD, SHIELDED AND MAX. 2' ABOVE DECK 9. AT TIME OF NEXT MAINTENANCE, DECK SPACING SHALL BE 1" 10. ENTIRE SITE IS WITHIN RIVERFRONT RESOURCE AREA 11. AT TIME OF NEXT MAINTENANCE, CONSULT CONSERVATION COMMISSION TO DETERMINE PERMITTING REQUIREMENTS 12. DISTANCE TO OPPOSITE SHORE GREATER THAN 350' REFERENCES CTF 235050 DOC. 1,495,936 LOT 17 LCP 28477—B (CURRENT) CH 91 PIER LICENSE #3047, DOC. 559,672-1 SHOWING EXISTING LICENSED PIER WITH PROPOSED FLOAT MODIFICATION AND WALL AND PILINGS TO BE LICENSED AT SURVEY: NHO DRAFTED BY: $30 CHECKED BY: DAO PIER.DWG 24-346 DATE DANIEL A. OJALA, P.E., P.L.S.