HomeMy WebLinkAboutDecision 4509 - Title 5 Site PlanNOT TO SCALE) FOR CARRIAGE HOUSE/GARAGE BLDG. ONLY SILL ELEV. 25.7' ACCESS COVERS TO WITHIN 6" OF FIN. GRADE IN AREA OF PIPE EXIT) 2" PEASTONE OR GEOTEXTILE FILTER FABRIC OVER STONE MINIMUM 75' OF COVER OVER PRECAST PRECAST H-10 RISERS (IYP.) 2'0 WATER–TEST D'BOX FOR LEVLLNL55 4" OSCH40 PVC PROP. TEE PIPES LEVEL 1ST 2' ALL SYSTEM COMPONENTS SHALL BE MARKED WITH MAGNETIC TAPE OR COMPARABLE MEANS FOR FUTURE LOCATION. CONCRETE COVERS TO WITHIN 3" GRADE 9% SI nPF REOUIRED OVER SYSTEM 122.0 BLOCKS OR PRECAST RISERS MORTAR ALL H-10 2COMPONENTS INV'S F1 18.412, ENDS ( NP') SIDES 19.23' Zl.8 f 10" 1500 GAL H-10 14 0 0 0 0ROP.) 21.38 TEE SEPTIC TANK TEE ° ° ° ° amaa a oa aoaa— ___mm >ooa00000 1.13' aa 51o a oa ooa o aoaoo , ° ° 0 ° o o o 000 000 o 00000 0000000076' 000°000°o°o p >000000 0 0 0 0 0 0 0 0 0 o o o o Q Daaaaa® mm Ef: OnaO ,0000000000°0 0 0 10000GASBAFFLE ::' _00000 0 o_ 000°0000 0 0 0 0 cc o°°°° oaaaaa®aeon ooaaaonaaaa .°°°° 000018. 18.49' 0000°°°° o0og o 16.4 4' LIQ. LEVEL (ACME OR EQUAL) 0000°°°o 0000 0000000000a000000000000000000000 " o o00 o_°__.o 0 0 0 0 0 `.o_0_0_n.0.0 0 3/4 –1-1/2" DOUBLE WASHED STONE H-10 500 GAL. LEACHING CHAMBER BY ACME PRECAST OR EQUAL. 2) UNITS REQUIRED ALL AROUND PRECAST STRUCTURES 6" CRUSHED STONE OR MECHANICAL OVERALL DIMENSIONS TO OUTSIDE OF STONE: 22.0' X 8.83' 4.4 COMPACTION. (15.221 [2]) 2 % SLOPE) (LQ Z% SLOPE) (–!—% SLOPE) LEACHING FOUNDATION— 21' SEPTIC TANK 23' D' BOX 11' FACILITY 12.0' BOTTOM TH-1 THE INSTALLER SHALL VERIFY THE LOCATIONS OF ALL NO GROUNDWATER FOUND _ UTILITIES AND ALL BUILDING SEWER OUTLETS AND ELEVATIONS PRIOR TO INSTALLING ANY PORTION OF SEPTIC SYSTEM NOTE: BUILDING SEWER TO EXIT IN AREA SHOWN, AT MIN. ELEVATION SHOWN LEGEND yy EXISTING CONTOUR X 99-1 EXIST. SPOT ELEV. 99 PROPOSED CONTOUR 99 11 PROPOSED SPOT EL. TH 1 TEST HOLE 2 SLOPE OF GROUND C -OL) UTILITY POLE FIRE HYDRANT NOTE: NOT ALL SYMBOLS MAY APPEAR IN DRAWING TEST HOLE LOGS ENGINEER: DANIEL E. GONSALVES, SE WITNESS. PHIL RENAUD DATE: 4/15/14 PERC. RATE _ < 2 MIN/INCH CLASS I SOILS ELEV. 0„ ` V 22.0' A LS 1OYR 3/2 19" B LS 43" 1OYR 5/8 18.4' C PERC MS 10YR 7/4 120" 12.0' NO GROUNDWATER ENCOUNTERED 14-061 NOTES 1. DATUM IS APPROX. NGVD 2. MUNICIPAL WATER IS EXISTING 3. MINIMUM PIPE PITCH TO BE 1/8" PER FOOT. 4. DESIGN LOADING FOR ALL PROPOSED PRECAST UNITS TO BE AASHO H-10 5. PIPE JOINTS TO BE MADE WATERTIGHT. 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH 310 CMR 15.000 (TITLE 5.) 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO BE USED FOR LOT LINE STAKING OR ANY OTHER PURPOSE. 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC. 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED FROM BOARD OF HEALTH. 10. CONTRACTOR SHALL BE RESPONSIBLE FOR CALLING DIGSAFE (1-888-344-7233) AND VERIFYING THE LOCATION OF ALL UNDERGROUND & OVERHEAD UTILITIES PRIOR TO COMMENCEMENT OF WORK. 11. ANY UNSUITABLE MATERIAL ENCOUNTERED SHALL BE REMOVED 5' BENEATH AND AROUND THE PROPOSED LEACHING FACILITY. o 10 20 30 ao 50 FEET DATE DANIEL A. OJALA, P.E., P.L.S. LOCUS MAP NOT TO SCALE ASSESSORS MAP 132 PARCEL 130 SYSTEM DESIGN: GARBAGE DISPOSER IS NOT ALLOWED PROPOSED 1 BR IN EXIST. CARRIAGE HOUSE/GARAGE DESIGN FLOW: 2 BEDROOMS @ 110 GPD = 220 GPD USE A 220 GPD DESIGN FLOW SEPTIC TANK: 220 GPD (2) = 440 USE A 1500 GAL. SEPTIC TANK LEACHING: SIDES:` 2 (22 + 8-.83)-2 (.74) 91 - GPD BOTTOM 22 x 8.83 (.74) = 143 GPD TOTAL: 317.S.F. 234 GPD USE (2) 500 GAL. LEACHING CHAMBERS (ACME OR EQUAL) WITH 2.5' STONE AT ENDS AND 2' AT SIDES p te M APPROVED DATE BOARD OF HEALTH TITLE 5 SITE PLAN OF 41 CENTER STREET YARMOUTH PORT PREPARED FOR JACK HANNON REV. MAYL51 2 014114 ( ELEV.) MAY 6201 YARMOUTH BOARD OF APPS, off 508-362-4541 I fax 508-362-9880 downcope.com 00WO c41,0e engineering, inc. civil engineers land surveyors 939 Main Street ( Rte 6A) YARMOUTHPORT MA 02675 3