Loading...
HomeMy WebLinkAbout5204 43 Webster Rd Pool Plans 11.08.24�41— 4' — 4' 4' � 4' 12' 8' — FINISHED 4, FINISHED4'-4' F DEPTH DEPTH 2 INCHES SAND OR VERMICULITE A -FRAME DETAIL DECK SUPPORT DETAIL A -FRAME BRACE PANEL STAKE HORIZONTAL BRACE SHORT BRACE PANEL LONGBRACE N❑N-DIVING POOL N13TES 1) DEPTH AND SHAPE OF POOL MEET MINIMUM STANDARDS OF THE 2021 INTERNATIONAL SWIMMING POOL AND SPA CODE FOR RESIDENTIAL IN -GROUND SWIMMING POOLS. 2) A MEANS OF EGRESS FOR BOTH THE DEEP END AND THE SHALLOW END OF THE POOL MUST BE PROVIDED IN ACCORDANCE WITH THE 2021 INTERNATIONAL SWIMMING POOL AND SPA CODE SECTION 809. 3) EQUIPOTENTIAL BONDING MUST BE PROVIDED IN ACCORDANCE WITH THE NATIONAL ELECTRICAL CODE NFPA 7M PANEL 4) ALL A -FRAME BRACES ARE TO BE MOUNDED WITH A MINIMUM OF ONE CUBIC HEIGHT FOOT OF CONCRETE OR A SIX-INCH THICK CONTINUOUS POURED CONCRETE PERIMETER COLLAR. 5) 'NO DIVING' LABELS ARE TO BE INSTALLED AROUND THE PERIMETER OF POOL. 6) SUCTION ENTRAPMENT AVOIDANCE IS TO BE INSTALLED IN ACCORDANCE WITH ANSI/APSP/ICC-7. 7) ALL WORK NOT SPECIFICALLY SHOWN IS TO BE DONE IN ACCORDANCE WITH THE REQUIREMENTS OF THE 2021 INTERNATIONAL SWIMMING POOL AND SPA CODE AND ALL OTHER APPLICABLE CODES. 8) THE POOL BECK/COPING IS WITHIN 12 INCHES OF THE DESIGN WATERLINE WHICH SATISFIES THE REQUIREMENT FOR HANDHOLDS PER THE 2021 ISPSC SECTION 323.1 et al. INTERNATIONAL SWIMMING POOLS NOTES SWIMMING POOLS ARE DANGEROUS WHEN USED IMPROPERLY. NEVER ➢IVE IN THE SHALLOW END OF ANY POOL. CONSULT WITH THE ➢IVING BOARD AND SLIDE MANUFACTURER(S) AND THE ASSOCIATION OF POOL AND SPA PROFESSIONALS (2111 EISENHOWER AVENUE POOL PERIMETE Ri 60' ALEXANDRIA, VA 22314 (703-838-0093)PRIOR TO INSTALLING DIVING BOARDS AND/OR SLIDES ON POOL AREA, 200 SgFt THIS POOL TO ENSURE THE POOL MEETS THE EQUIPMENT MANUFACTURERS MINIMUM STANDARDS FOR VOLUMES 6,500 APPROX. GAL. ALLOWABLE INSTALLATION OF THEIR PRODUCT(S) ON THIS POOL. INTERNATIONAL SWIMMING POOLS IS NOT RESPONSIBLE FOR THE POOL'S INTERIOR DETAIL, RATHER THE LINER MANUFACTURER MUST ENSURE THE INTERIOR MEETS A. P. S. P. AND A. N. S. I. STANDARDS. IT IS THE RESPONSIBILITY OF POOL BUILDERS, TOWN OFFICIALS AND POOL OWNERS TO FOLLOW ALL SAFETY GUIDELINES OF THE A.P.S.P., LOCAL ORDINANCES, AND EQUIPMENT MANUFACTURERS. L=4' L=4' L=4' 90• VF 54' WALL BILL OF MATERIALS QTY, L=4' DESCRIPTI❑N TOPPED OFF WITH 4' OF CONCRETE OVER A CRUSHED STONE BASE. LINER TRACK AT DASHED LINES CONCRETE, CRUSHED STONE, REBAR, ONLY. — — — — — — — — — — — — — AND HARDWARE NOT INCLUDED. ie' A 4'