Loading...
HomeMy WebLinkAbout25-A178 22 Apache Drive ApprovedTOWN OF YARMOUTH ,-' 1146 ROUTE 28, SOUTH YARMOUTH, MA 02664-4451 Telephone (508) 398-2231 Ext. 1292—Fax (508) 398-0836 NOV 1 6 7025 OLD KING'S HIGHWAY HISTORIC DISTRICT COMMITTEE -l-cghway I(IRMHTH THlgti CLERK RE APPLICATION FOR `iistoflc District DEC 9'25 AtM9:28 CERTIFICATE OF APPROPRIATENESS Application is hereby made for issuance of a Certificate of Appropriateness under Section 6 of Chapter 470, Acts of 1973 as amended, for proposed work as described below & on plans, drawings, photographs, & other supplemental info accompanying this application. PLEASE SUBMiT 4 copies OF SPEC SHEET(S), ELEVATIONS, PHOTOS, & SUPP EM NTAL INFORMATION. Check All Catecorles That App� Indicate type of Building: Commercial Residential 1) Exterior Building Construction: New Building Addition Alterations Reroof Garage Shed Solar Panels ,Other: 1� 2) Exterior Painting: Siding Shutters Doors Trim Other: 3) Signs/Billboards: New Sign Change to Existing Sign 4) Miscellaneous Structures: Fence wall Flagpole Pool Other: Please type or print legibly: _ 2 I Address of proposed work:. /LL. { h , ` Map/Lot # j I z V Owner(s):1ba.L_ �=4' - Phone #: All applications must be submitted 8y owner or accompanied by letter from owner approving submittal looffapplication. Mailing address: kjf) (�- Year built: I Email: I kferred notification method: Phone Email Agenticontractor: Phone #: { Mailing Address: e1 5+rx , t- f 1 Email: lQ . I ft yV n �+'/ti Preferred notification method, Phone Email LSS i 2 fycj (Y-) Signed (Owner or agent Date: D Owner/contractor/age aware a permit is req ed from th?l3uilding Department. (Check other depa t nts, also) D If application is approved, al is subject to a 10-d y appeal period required by the Act. I d 1 D D )yy 0� (rl D This certificate is good for one yea or upon date of expiration of Building Permit, whlahevef atel'�h ll.he`f to . All new construction will be subject to�pection by OKH. OKH-approved plans MUST be available on-sih9;f6r iri rrung & fifial lnspaciions. Rcvd Date: l l 1(q I a t Amount * LIo' W Cash/CK#:-;>3(,v (c6 Rcvd by: 45 Days: i�lt�)aS Date Signed: Approved Approved with Modifications �D led Reason for Denial_ Alf sictrit 2 5 - A 1 78 APPLICATION #: TOWN OF YARMOUTH OLD KING'S HIGHWAY HISTORIC DISTRICT COMMITTEE 1146 ROUTE 28, SOUTH YARMOUTH, MASSACHUSETTS 02664-4451 Telephone (508) 398 2231 Ext_1292 Fax (508) 398-0836 STATEMENT OF UNDERSTANDING CHANGES TO AN OLD KING'S HIGHWAY APPROVED PLAN As property owner/contractor/agent for construction at O bz , Map/Lot J 4 4 CIA # o _ -/V 1� Approval Date: I certify that I understand the following requirements regarding any changes that may be required for this project: In accordance with paragraph 2(a) of section 1.03(General Procedures) of the OKH 972 CMR Rules and Regulations: Only minor changes may be approved by the Committee without the filing of a new application and a new hearing. Minor changes include alterations that can be done without a detrimental impact on the overall appearance of the project such as altering a single window or door change or a minor change of colors. Ali minor changes by amendment will require the local Committee's or its designee's approval. All changes to previously OKH approved plans require notification to and approval from the local OKH Committee. Change requests must be submitted to the Committee in writing on the appropriate request form, which may be obtained from the OKH office. All change approvals must be obtained before incorporating the change into the project. If the change has been implemented prior to receipt of OKH approval, a Minor Change approval or Certificate of Appropriateness application for the revised plans is still required and will result in a doubled filing fee for the appropriate category of work. Failure to comply with the above statements will result in the Building Department issuing a stop -work order or delaying the issuance of an Occupancy Permit or final inspection approval. I have read and understand the above statements. 41 Date:A14�w - Updated 5/31/2024 r� � DD i- or�:) � nn,, L_U_.k_J LiL-Pj\,J TAp DEC 0 8 2025 Signed: Old Kings Highway (wn ContractorlAgent) J Historic District Signed: . —16, (Chairman: Old King's Highway Committee) TOWN OF YARMOUTH 1146 ROUTE 28, SOUTH YARMOUTH, MASSACHUSETTS 026644451 Telephone (508) 398-2231 ExL 1292 Fax (508) 398-0836 OLD KING'S HIGHWAY HISTORIC DISTRICT COMMIT 1nr ��� Um 45-DAY TIMEFRAME WAIVER A 1 7 8 ,. �4 Application #: 2 5 r Project Address: Application Received Date: tl f lgjdt; 45 Day Decision Deadline: i 3 (;�,Jas NOV 1 b 2025 Old Kings Highway Historic; District 1/We, the undersigned owner, contractor, or agent, do hereby waive the 45-day timeframe for a determination on our application for a Certificate of Appropriateness/Demolition/Exemption by the Old King's Highway Historic District Committee for the following project: n S Il -Testa >yNcl b?e(, . Date: 7 t �� �l°I�t(�;tiViJ;ll U 11J-) Old King's Highway Signed: Historic Dister Owner 4�4411 2 5 - A 1 7 8 GENERAL SPECIFICATION SHEET ddress: �� �r_- t FOUNDATION: Material: Exposure (Not to exceed 18"): CHIMNEY: Material/Color: GUTTERS: Material/Color: ROOF: Material: Pitch (7/12 min) Height to Ridge: Color: SIDING: Material/Style: Front: Sides/Rear: COLOR CHIPS Color: Front: Sides/Rear: TRIM: All windows & doors to be trimmed with: Material: 1x 4 1x5 (Circle one.) Color: R00 TO DOORS: Qty: Material: Color: NOV 1 b 10n Style/Size (if not listed/shown on elevations): STORM DOORS: QOld tCir7g's Highway Material: Color: Historic District GARAGE DOORS: Qty: MatT Style: Color: WINDOWS: Isidw: Front: Left: Right: Rear: Color: Manufacturer/Series: Material: Grilles (Required): Pattern (616, 211, etc.) Grille Tvr)e: True Divided Lite: Snap -In: Between Glass: Permanently Applied: Exterior Interior D ' Dj MR STORM WINDOWS: Qty: Material: Color: SHUTTERS: Marl: Style: Paneled Louvered Color: DEC 0 8 707.9 SKYLIGHTS: Qty: Fixed Vented Size Color: Old King's Highway DECK: Size: Decking Mat'f: Color: Historic District Railing MatT Style: Color: WALLS/FENCES" (Max 6' height): Height: MatT Style: Color: (Show running footage & location on plot plan.) *Finished side of fence must face out from fenced in area. UTILITY METERSIHVAC UNITS: Location: Screening: LIGHTS: Qty: Style: Color: Location(s): LIGHT POSTS: Qty: Material: Color: Location(s): Additional information: r) APPLICATION #: 2 5 - A 1 7g z�¢ o TOWN OF YARMOUTH to OLD KING'S HIGHWAY HISTORIC DISTRICT COMMITTEE 6 4 ` ABUTTERS' LIST Applicant's (Owner) Name: Property Address/Location: ` �2 V-w-e— Hearing Date: Notices must be sent to the applicant and abutters (including owners of land on any public or private street or way) whose property directly abuts or is across the street from the applicant. The OKH Office will send out notices using the addresses as they appear on the most recent applicable tax list. Note: Instructions for obtaining the abutters Map and Lot numbers can be found on the Old King's Highway Department page on the Town website: www.varmouth.ma.us Map Number Lot Number Applicant Information: 1 4 3 10-7 I. Abutter Information: ij Nov 1 G 2025 Old t<inq'1', Highway Historic District DEC 0 8 10 Old King's Highway Historic District Me V IH3 o1 �.1? 1Lr3 1113 i Lt3 1 Application #: 2 5 - A 1 7 8 1431 1141 1 I GLYNN PAUL C TR PAUL C GLYNN LIVING TRUST Please use this signature to certify this list of properties 22 APACHE DR directlyabutting and across the street from the parcel located at: YARMOUTH PORT, MA 02675-2103 g 22 Apache Dr., Yarmouth Port, MA 02675 Assessors M p 143, Lot 114 1431 1161 1 1 ANGELL ROBERT B Andy Machgdo, Director of Assessing ANGELL JANE M November 21, 2025 62 SETUCKET RD YARMOUTH PORT, MA 02675-2181 1431 1151 1 1 HEENAN MICHAEL F HEENAN MARIE E 28 APACHE DR YARMOUTH PORT, MA 02675-2103 TD� 1431 147/ 1 1 FAGAN PAUL M NOV 2 12025 19 APACHE DR YARMOUTH PORT, MA 02675-2103 Old Kings Highway Historic District 1431 1131 1 1 JASIE JOSEPH C JR JASIE JEAN C 16 APACHE DR YARMOUTH PORT, MA 02675-2103 1431 1191 ! 1 PECORARO BRIAN F PECORARO RENE Ma� 13 NICHOLAS DR YARMOUTH PORT, MA 026752 1431 1211 l 1 KINNEN ELIZABETH J TR KINNEN DREW A TR 10 NOSBAND AVE 6M WHITE PLAINS, NY 10605 yip DEC 0 8 7025 Old King's Highway Historic District Y 0 U CL N N a In N N r n °d N N M '� o oRivE E N�CN N N f"1 N Q � .� 00OR ri �M Ln — f�1 4 " �E M LUCERNE 4 rn rn f • ,� V �% 1 i IN0 or ,n� T Ln r . MUSKET LANE rry V1 N M M M 00 1a1 Ln en h *"rtt ■ � Vn N Lon ri 4g, " d � own CO x �n iw Q Ln N S L A F" 'ZrT c u1 r 14 ion s;qq 1 �w� r. u NOV 1 G 2025 Old r\,nr-.' , ; ighway Historic District r DEC 0 B 7079 Old King's Highway Historic District Ln 04 0 aE, a Q z 2 5 — A 1 7 8 Docusign Envelope ID: BFC58CID-2486-474E-8E1E-E03A9CC68DEF omw %wA411RUII 225 Bush Street Suite 1400 NOV 1 1, 7025 San Francisco, CA 94104 permitteam-srs®sunrun.com Old 11%'M ,`S Highway Historic District AUTHORIZATION LETTER FOR BUILDING APPLICATION AND PERMITTING FORMS ONLY. TO WHOM IT MAY CONCERN: I, Paul Glynn , residing at 22 Apache Dr yarmouth MA 02675 hereby authorize an assigned Sunrun Permit Coordinator, to act as my representative in all matters related to the building application and permitting process, including the collection of my signature for required forms as it relates to 22 Apache Dr Yarmouth MA 02675 This authorization is effective from 10/27/2025 and will remain valid for one year, unless revoked by me in writing. acknowledge that I will be bound by any decision made by my assigned Sunrun Permit Coordinator on my behalf during this period. I also understand that my assigned Sunrun Permit Coordinator and the building or permitting department are not responsible for verifying the accuracy of the information provided by myself or my representative. Therefore, I give full consent in regards to this authorization with respect to building applications and permit forms. Sincerely, �E)ikr Name: Paul Glynn Signature: Date: 10/27/2025 �ffD D, D� M�D TIC DEC 0 H 70 Old King's Highway Historic District 2 5 - A 1 7 8 fn a m W 0) O O �, V — fftwz�.4 ; L L L . J�1 %L-�kw w. --mow L a L Oil a J-LJ OL ii 0 Z ytJ W UZ�' W ZO n m O 3 d} W ~. W co `ULMU _ m g Z S Z W O z w U -Fiall py6��np s w S2 W w a w U'�'-, i7 23 F � i� uj a 11L do uj o z U N K Q fn U y W O Z W � « LL4 1011 -- a Yv U Z5 0 0 W W o 0 U. 0 0 NOV 1 4 70B a to O �u o WZ Old Kirlsghway �Xy Historic D:strict mU W O 0 Amt�i W R ri� W W 7 m U �.t4' aU aDF 70 `2zz KLou 7 W W ..50. 0 $a0 OOWFaW jw n0 W 1 Z� U O S S Za M� Z 0� K2 W C O �g�qJJy F-W W C.) O��WO2W.UW9 1 Q S j m* n 1 0 y Z! U O 9 t F z - L S�¢rn c�oz ui(WLzj yW :) zOO N} DEC p poit ZOOaUTZO�� cZJm nmv>UmtiLLOd'ZOW�00.' Old Kings Highway O O v,� ;U�,SW� 24 Historic District Y U a} W , =_ y vni ESOY^�WJF ZZN C) a- �F Z m8fl-0 ,0 �Zz�ap ZO (' gONLU aWa-haw oc� ooafn U 1 . . . U . m � Z 00 ~ O } CO).��• -- IL LL LU y N z a CL 0 Z r OLLIYJu, �ZZxx U ~ Z X O Wn w _ 0 ; p Ig G U 0 H 0 3 W _ "_ 5 ffiz� Y w€ s d> 3 3 Uzo z g g N> q m + wa' d CV wwo W z z Ss �7da rc u i w w w`a'' �w Q W U eq W 4 a N �< N K a FU OZ a� adw Ja Lu N OQZ 2Cw] a> NOV 1 4 2025 g p� O Old 'Highway o�$ zww a= {� j����k�jj� Historic District ir O �E rc WO W Ul �N (ti WN DEC 6 8 nn r �E LJT fi Highway Lu w Old l<ing s W lst6ct Historic w o w W I Oz �d �J �w r wU w ra w LO m w U J Lu w k a R o z � a O w Z O C VV / a C Q t•' U z o W J x J K Fw- m err W U U d 'W O U w zW vk W O W o 0 $ W- N 4 O 40 oS N r w � U u y4 w W W y Egg 4 g y� � m IL m a mg ma L , d Lu KLU W jw q W Wzx z az fq SQ a W Z W N Ri �� or ad } w w W Q W � €1 aa y NOV 1 b 20B Y o IL Old Kil-19 €itgt way \ \ a /� 2 o Historic Dist :(A Z w �\ y w w O WLU J z j j J J ay Z m o�z o? i D � � � am zm o wW D 4 jj``II X� ��i0 Q ra V {� a \// Wt OC i E:1¢ \/ WUp Wd'I..Lxu' Ou C OZW EC 0 8 7U�.1 i// owu 0,Q0,8 00_Ux w, F~aO] i~Al�W J�LL old King' , Highv gay E:1y �\ ����x�i;so��x F W W W y Q Historic Distri z m=$=ma-� W Z W W LL O \/ I /X maw w� w W„uoa OZ a a 4 a� \\f y CM W awl U. O I Wy/w \ q3 z W o ]S ��/ lu LLl 8 2 5 78 z�g= z � � 3 w�Od n U 3 Wwo 1g U R bwzrj z2 � i _ d gg w9EW J.- > w a w ❑ 0x a rJ6 J LILi i. i ---- � �� T �M NOV ?4'1.025 q C I Old Kin 's !-Iighway G Historic District 3 w12 N y� o (%} DEC 0 8 2025 r n La U W `J w , mg Old King's Highway { Lo ee � 7 8, ii r�1 m�N wo _ L s3 Q _� Historic District 03,� zQoW��� 1 Z U) W �_ w O � �� a i 1 mW 0O = w I1 S62W2 ��amRip x s_¢ V. f Q. lag 4� w w a S s� ?i a J o � a _ a 4 LLJ m o -� � W � z U w v � � w � W N N 2 N f 1 Z IL O h � � Z m m M NN N w W Z (A ....x ....T� ...x Ljj cm Z oUl } # �za w N � 00 k Z I 2 O 3 j �} WZZ= TeS W _ � n. i O Q Q W ZI� W d Q N K d Fg Old; ,: `. .,i:ghway Historic District r ti 9 ° 3 aim W V G ir Z L1. 7 W I ilia LU ¢ .LU O Z In LLI ULJi a LL mCa[n agng CI z La JGaj50 N Gi0 ��Ce. E L.i CD 0:� LU m _ a 'e eE z {� fL yy�� }- LL s W J 7 _1 4 z V W u W iu cn -a �U_ w !A N p U ® m I fO vU 1 1N1 \I J Lwij < w uj p �43 = Z � N CoW � W mo�'4uj' } W a a ,:ing`5 Hig hwaY tStnct W IStorjc l] W b F�Jj inn � Sao �� m § 6w Z zzX% S o g W€ O yX� OW ZWLl — a. J IN 1° 8 0 Wo rn Z d Z a � Z W o I °C?o� g U FfnZ,pL� y�j.J F4xWL s OTCY"c&� U25 - 7 U;0 N z �, L, Q�- L �w Q ` rcgnU w 0w a Ri L R y 4 ~ w Z F,4avf T wa' ry w W a W LSD NOV 1 4 70 - Old K&)g'', H; sway Historic District }�`�J " O� W DD DEC O8W Old King's Highway Historic District ■ ■ ® z a-s0�F- LL W j Wz UcnYZ ujw z � a QQ>-uWz r h w z mQmo co -W CL w>N o Ix N 0 LL o Q w m O _ D W O �wz z Q �wW F W� �.~m Ufa OJ Z QXZ -z1a WGl w tu= �WD CY WadU < co W �w¢� 1-4 '�� W � O U Iz- Q w J W _ pp m }' ZVJQ W CV R SJ o c� �Q } I i Zu)LL r �a F- mWwW acym w s�� 5_ A 1 7 8 Powerwall 3 Power Everything Powerwall 3 is a fully integrated solar and battery system, designed to accelerate the transition to sustainable energy. Customers can receive whole home backup, cost savings, and energy independence by producing and consuming their own energy while participating in grid services. Once installed, customers can manage their system using the Tesla App to customize system behavior to meet their energy goals. Powerwall 3 achieves this by supporting up to 20 kW DC of solar and providing 11.5 kW AC of continuous power per unit. It has the ability to start heavy loads up to 185 A LRA, meaning a single unit can support the power needs of most homes. Powerwall 3 is designed for mass production, fast and efficient installations, easy system expansion, and simple connection to any electrical service. NOV 1 4 2015 Old i<,im, , ,,rNay Historic District DEC 0 8 2025 )1d King's Highway Historic Dlstftt zWA 5-A 1 78 Powerwall 3 Technical Specifications System Technical Model Number Specifications Nominal Grid Voltage (Input & Output) Grid Type Frequency Overcurrent Protection Device Solar to Battery to Home/(arid Efficiency Solar to Home/Grid Efficiency Supported Islanding Devices Connectivity Hardware Interface AC Metering Protections Customer Interface Warranty Solar Technical Maximum Solar STC Input Specifications Withstand Voltage PV DC Input Voltage Range PV DC MPPT Voltage Range MPPTs Maximum Current per MPPT (I-1) Maximum Short Circuit Current per MPPT (I.) Battery Technical Specifications 2024 Nominal Battery Energy Maximum Continuous Discharge Power Maximum Continuous Charge Power Output Power Factor Rating Maximum Continuous Current Maximum Output Fault Current Load Start Capability 0 s) Power Scalability 1707000-xx-y 120/240 VAC Split phase 60 Hz 60 A 89%U 97.5%3 Gateway 3, Backup Switch, Backup Gateway 2 Wi-Fi (2.4 and 5 GHz), Dual -port switched Ethernet, Cellular (LTE/4G4) Dry contact relay, Rapid Shutdown (RSD) certified switch and 2-pin connector, RS-485 for meters Revenue Grade (+/- 0.5%) Integrated arc fault circuit interrupter (AFCI), Isolation Monitor Interrupter (IMI), PV Rapid Shutdown (RSD) using Tessa Mid -Circuit Interrupters Tesla Mobile App 10 years 20 kW 600 V DC 60 — 550 V DC 60 — 480 V DC 6 13A5 15A5 TD A t OV-}- 4-202.� Old K,.-I: j-.,orlway__ Historic District u 13.5 kWh AC DEC 0 3 2D25 11.5 kW AC 5 kW AC 0 -1(Grid Code configurable) 48 A 10 kA 185 A LRA Up to 4 Powerwall 3 units supported 'Typical solar shifting use case. 'Values provided for 25" C (77°F), at beginning of life. 3.3 kW charge/discharge power. 'Tested using CEC weighted efficiency methodology. 'The customer is expected to provide internet connectivity for Powerwall 3; cellular should not be used as the primary mode of connectivity. Cellular connectivity subject to network operator service coverage and signal strength. Where the DC input current exceeds the MPPT rating, a jumper can be used to combine two MPPTs into a single input to intake DC current up to 26 A IMP / 30 A I,_ Powerwail 3 Datasheet 25-A 178 Powerwall 3 Technical Specifications Environmental Operating Temperature —200C to 500C (-4°F to 1220F) 6 Specifications Operating Humidity (RH) Up to 1000A, condensing Storage Temperature —200C to 300C (-40F to 86*F), up to 95% RH, non - condensing, State of Energy (SOE): 25% initial Maximum Elevation 3000 m (9843 ft) Environment Indoor and outdoor rated Enclosure Rating NEMA 313 Ingress Rating IP67 (Battery & Power Electronics) IP45 (Wiring Compartment) Pollution Rating PD3 Operating Noise @ 1 m <50 db(A) typical <62 db(A) maximum Performance may be de -rated at operating temperatures above 400C (1040F). Compliance Certifications Information Grid Connection Emissions Environmental Seismic Fire Testing Mechanical Dimensions Specifications Weight Mounting Options DSO p a 71175 Old King. .- Highway Historic flistnct NOV 'l I, 2025 Old Ktrlc s : 'dyriway Historic District UL 1642, UL 1699B, UL 1741, UL 1741 SA, UL 1741 SB, UL 1741 PCS, UL 3741, UL 1973, UL 1998, UL 9540, IEEE 1547- 2018, IEEE 1547.1, UN 38.3 United States FCC Part 15 Class B RoHS Directive 2011/65/EU AC156, IEEE 693-2005 (high) Meets the unit level performance criteria of UL 9540A 1099 x 609 x 193 mm (43.25 x 24 x 7.6 in) 130 kg (287 lb) Floor or wall mount 1099 mm u 609 mm B 193 mm 2024 Powerwall 3 Datasheet 25A 1 7 3 Solar Shutdown Device Technical Specifications The Solar Shutdown Device is a Mid -Circuit Interrupter (MCI) and is part of the PV system rapid shutdown (RSD) function in accordance with Article 690 of the applicable NEC. When paired with Powerwall 3, solar array shutdown is initiated by any loss of AC power. Electrical Model MCI-1 MCI-2 Specifications Nominal Input DC Current Rating (IM� 13 A 13 A Maximum Input Short Circuit Current (ICJ 19 A Maximum System Voltage (PVHCS) 600 V DC Maximum System Voltage is limited by Powerwall to 600 V DC. RSD Module Maximum Number of Devices per String Performance Control Passive State Maximum Power Consumption Warranty Environmental Specifications Mechanical Specifications Compliance Information Operating Temperature DEC 8 8 7075 U King's Highw Storage Temperature Enclosure Rating 5 Power Line Excitation Normally Open 7W 25 years -400C to 500C (-40°F to 122°F) --30*C to 70'C (-22°F to 158°F) NEMA 4X / IP65 Electrical Connections ID I ifn. Connector Housing F�MC4 _.J._. lastic Dimensions�U 2�2� 125 x 150 x 22 mm (5x6x1in) Weight Cld {, 350 g (0.77lb) Mounting Options Histanc District ZEP Home Run Clip M4 Screw (#10) M8 Bolt (5/16") Nail / Wood screw Certifications RSD Initiation Method UL 3741 PV Hazard Control (and PVRSA) Compatibility See Powerwall 3Installation Manual 2024 Powerwall 3 Datasheet 17 A 1000 V DC' 5 Power Line Excitation Normally Open 7W 25 years -450C to 700C (-49°F to 158°F) —3WC to 700C (-22°F to 158°F) NEMA 4X / 1P65 MC4 Connector Plastic 173x45x22mm (6.8 x 1.8 x 1 in) 120 g (0.26 lb) Wire Clip UL 1741 PVRSE, UL 3741, PVRSA (Photovoltaic Rapid Shutdown Array) External System Shutdown Switch or Powerwall 3 Enable Switch d 25- A 1 7 8 a Gateway 3 Tesla Gateway 3 controls connection to the grid in a Powerwall system, automatically detecting outages and providing seamless transition to backup power. It provides energy monitoring that is used by Powerwall for solar self -consumption, time -based control, and backup operation. Performance Model Number 1841000-01-y Specifications Nominal Grid Voltage 120/240 V AC Grid Configuration Split phase Grid Frequency 60 Hz Continuous Current 200 A Rating Maximum Supply Short 22 kA with Square D or Circuit Current Eaton main breaker 25 kA with Eaton main breakers IEC Protective Class Class I Overvoltage Category Category IV BOnly Eaton CSR or BWH main breakers are 25 kA rated. Environmental Specifications Operating Temperature Operating Humidity (RH) cqni;� � 'D i 'I is Maximum Elevation - Environment Enclosure Type Old King's HOP11Y Historic Distinct Compliance certifications Information _ Emissions AC Meter Revenue accurate (+/- 0.5%) Communication CAN User Interface Tesla App Backup Transition Automatic disconnect for seamless backup Overcurrent 100-200 A Protection Device Service entrance rated Eaton CSR, BWH, or BW, or Square D QOM breakers Internal Panelboard 200 A 8-space/16 circuit breakers Eaton BR, Siemens QR or Square D HOM breakers rated to 10-125A Warranty 10 years -200C to 5011C (-4°F to 122°F) Up to 1000A, condensing 3000 m (9843 ft) Indoor and outdoor rated NEMA 3R UL 67, UL 869A, UL 916, UL 1741 PCS, CSA 22.21071, CSA 22.2 29 FCC Part 15, ICES 003 Mechanical Dimensions 660 x 411 x 149 mm Specifications (26 x 16 x 6 in) Weight 16.3 kg (36 lb) Mounting options Wall mount NVIRM,p m6m NOV 1 4 20 Olt is ri. i .11wa Historic District ;d7'Q-LY6 2024 Powerwall 3 Datasheet R Backup Switch The Tesla Backup Switch controls connection to the grid in a Powerwall system, and can be easily installed behind the utility meter or in a standalone meter panel downstream of the utility meter. The Backup Switch automatically detects grid outages, providing a seamless transition to backup power. It communicates directly with Powerwall, allowing home energy usage monitoring from any mobile device with the Tesla app. Performance Specifications Environmental Specifications Compliance Information Mechanical Specifications Model Number Continuous Load Rating Maximum Supply Short Circuit Current Communication AC Meter Expected Service Life Warranty 1624171-xx-y 200 A,120/240 V split phase 22 kA with breaker$ CAN Revenue accurate (+/- 0.5%) 21 years 10 years 9 Breaker maximum supply short circuit current rating must be equal to or greater than the available fault current. Operating Temperature Storage Temperature Enclosure Rating _ Pollution Rating^' ^ I' Safety Standards Emissions Oki Kiny ,,, - Dimensions Historic District Weight Meter and Socket Compatibility External Service Interface Conduit Compatibility —400C to 500C (-40°F to 122°F) --40°C to 85°C (-40°F to 185°F) NEMA 3R PD3 USA: UL 414, UL 414 SB, UL 2735, UL 916, CA Prop 65 FCC, ICES 176 x 205 x 74 mm (6.9 x 8.1 x 2.9 in) 2.8 lb ANSI Type 2S, ringless or ring type Contactor manual override''' Reset button 1/2-inch NPT 10 Manually overrides the contactor position during a service event. �L1: you 1 7025 Old , i .-ilghway k- ;Istoric District 4 Powerwall 3 Patasheet 25-A 1 7g Backup Gateway 2 Backup Gateway 2 controls connection to the grid when paired with Powerwall 3, automatically detecting outages and providing seamless transition to backup power. Backup Gateway 2 also provides energy metering for solar self -consumption, time -based control, and backup operation. In this system configuration, Powerwall 3 acts as the Site Controller, with the Backup Gateway 2 Site Controller disabled. Performance Model Number 1232100-xx-y Specifications AC Voltage (Nominal) 120/240 V Feed -in Type Split phase Grid Frequency 60 Hz Current Rating 200 A Maximum Supply Short 10 kA" Circuit Current Overcurrent Protection 100 - 200 A, Service Device entrance rateds Overvoltage Category Category IV Internal Primary Revenue accurate AC Meter (+/- 0.2%) Internal Auxiliary Revenue accurate AC Meter (+/- 2%) Primary Connectivity Ethernet, Wi-Fi Secondary Connectivity Cellular (3G, LTE/4G)12 Environmental Operating temperature Specifications Operating Humidity (RH Maximum Elevation Environment Enclosure Type Ad kii� 1 5 J �"lr'W'c jf Historic District Compliance CertMeations Information Emissions User Interface Tesla App Operating Modes Support for solar self - consumption, time -based control, and backup Backup Transition Automatic disconnect for seamless backup Modularity Supports up to 10 AC - coupled Powerwalls Optional Internal 200 A 6-space / 12 circuit Panelboard breakers Siemens QP or Square D HOM breakers rated 10 - 80A or Eaton BR breakers rated 10 -125A Warranty 10 years " When protected by Gass J fuses, Backup Gateway 2 is suitable for use in circuits capable of delivering not more than 22kA symmetrical amperes. a Cellular connectivity subject to network operator service coverage and signal strength. —20°C to 50°C (-4°F to 122°F) Up to 100%, condensing 3000 m (9843 ft) Indoor and outdoor rated NEMA 3R UL 67, UL 869A, UL 916, UL 1741 PCS, CSA 22.2 0.19, CSA 22.2 205 FCC Part 15r ICES 003 Mechanical Dimensions 660 x 411 x 149 mm Specifications (26 x 16 x 6 i") Weight 20.4 kg (45 lb) Mounting options Wall mount, Semi -Rush mount U �4 660 mm NnV 1 70B Old I :Ighway Historic District 2024 Powerwall 3 Datasheet 7 25- A 1 7 8 Powerwall 3 Example System Configurations Powerwall 3 with Gateway 3 Whole Home Backup ,*— 9 Meter Grid Meter socket panel Gateway 3 Powerwall 3 with Backup Switch Whole Home Backup Backup Switch Meter Grid Meter socket panel Load center I Backup loads Powerwall 3 with Backup Gateway 2 Partial Home Backup I oarr'onar T � I I I Solar 1 Load center I Backup loads Powerwall 3 I UAtrona! — � I I I —Solar —I 4 Powerwali Utility Meter Main Breaker Grid Meter load center Backup Gateway 2 1 sO Non-essentlal loads 2d24 Powerwall 3 Patasheet mk��,R rll�,01_00 NOV 1 4 Mb Old Ki I`j ..> ogrlway Historic District 1 OPtmna! ^ '1 I�� 1 I I 1 Solar —1 _ 4 Load center I Backup loads Powerwall 3 8 2 5 - A 1 7g POWERWALL Backup Gateway 2 The Backup Gateway 2 for Tesla Powerwall provides energy management and monitoring for solar self -consumption, time -based control, and backup. The Backup Gateway 2 controls connection to the grid. automatically detecting outages and providing a seamless trans Uon to backup power. When equipped with a main circuit breaker, the Backup Gateway 2 can be installed at the service entrance. When the opt onal internal panelboard is installed, the Backup Gateway 2 can also function as a load center. The Backup Gateway 2 communicates directly with Powerwall, allowing you to monitor energy use and manage backup energy reserves from any mobile device with the Testa app. PERFORMANCE SPECIFICATIONS AC Voltage (Nominal) 120/240V Feed -In Type Split Phase Grid Frequency 60 Hz Current Rating 200 A Maximum Input Short Circuit Current 10 kA' Overcurrent Protection Device 100 200A, 4QrvKP Ertr_ nce Raters Overvoltage Category Category IV AC Meter Revenue a..{ Urate (*/- 0.2 ) Primary Connectivity Ethernet, Wi-Fi Secondary Connectivity CelLlar i3G, LTE/4G),' User Interface Tesla App Operating Modes Support for solar self -consumption, time -based control, and backup Backup Transition Automatic disconnect for seamless backup Modularity Supports up to 10 AC -coupled Powerwalls optional Internal Panelboard 200A 6-space / 12 circuit Eaton BR Circuit Breakers Warranty 10 years I When protected by Ciass J fuses. Backup Gateway 2 is suitable for use ir' circuits capahle of del"vering not more than 22kA symmetrical amperes. I The customer is expected to provide internet connectivity for Backup Gateway 2; cellular should not be used as the orimary mode of connectivity. Cellular connectivity subiPct to network ooerator service coverage and signal Strength. COMPLIANCE INFORMATION Certifications UL 67. UL 869A, UL 916, k-iL 1741 RGS CSA 22.2 0.19, CSA 22.2 R Emissions F 1 ��i— I 11 Noy 11,20b T 15 s L MECHANICAL SPECIFICATIONS Dimensions 660 mm x 411 mm x 149 mm (26 in x 16 in x 6 in) Weight 20.4 kg (45 lb) Mounting options Wall mourt. Semi -flush mount 7 660 T'15 Z L R DEC 0 8 79B LL- 411- tl tip 149 Old KIng J y �► Historic District ENVIRONMENTAL SPECIFICATIONS Operating Temperature Operating Humidity (RH) Maximum Elevation Environment Enclosure Type -200C to 50°C (-4°F to 122°F) up to 100%, condensing 3000 m (9843 ft) Indoor and outdoor rated NEMA 3R Old iki., ltghway Historic District TESLA.COWENERGv 25-A178