Loading...
HomeMy WebLinkAbout9 Miracle Site PlanGENERAL NOTES: A.) NEITHER DRIVEWAYS NOR PARKING AREAS ARE ALLOWED OVER SEPTIC SYSTEM UNLESS H-20 COMPONENTS ARE USED, B.)THE DESIGNER WILL NOT BE RESPONSIBLE FOR THE SYSTEM AS DESIGNED UN- LESS CONSTRUCTED AS SHOWN, ANY CHANGES SHALL BE APPROVED IN WRITING. C.) CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING THE LOCATION OF ALL UNDERGROUNDAND OVERHEAD UTILITIES PRIOR TO COMMENCEMENT OF WORK. CONSTRUCTION NOTES: 1.) ALL CONSTRUCTION SHALL CONFORM TO THE STATE ENVIRONMENTAL CODE, TITLE 5, AND THE REQUIREMENTS OF THE LOCAL BOARD OF HEALTH. 2.) SEPTIC TAN K(S), GREASE TRAP(S), DOSING CHAMBER(S) AND DISTRIBUTION BOX(ES) SHALL BE SET ON A LEVEL STABLE BASE WHICH HAS BEEN MECHANICALLY COMPACTED, OR ON A 6 INCH CRUSHED STONE BASE. 3.) SEPTIC TANK(S) SHALL MEET ASTM STANDARD C1127-93 AND SHALL HAVE AT LEASTTHREE 20" DIAMETER MANHOLES. THE MINIMUM DEPTH FROM THE BOT- TOM OF THE SEPTIC TANK TO THE FLOW LINE SHALL BE 48". 4,) SCHEDULE 40 PVC INLET AND OUTLET TEES SHALL EXTEND A MINIMUM OF 6" ABOVE THE FLOW LINE OF THE SEPTIC TANK AND SHALL BE INSTALLED ON THE CENTERLINE OF THE TANK DIRECTLY UNDER THE CLEANOUT MANHOLE. 5.) RAISE COVERS OF THE SEPTIC TANK AND DISTRIBUTION BOX WITH PRECAST CONCRETE WATER TIGHT RISERS OVER INLET AND OUTLET TEES TO WITHIN 6" OF FINISH GRADE, OR AS APPROVED BY THE LOCAL BOARD OF HEALTH AGENT. 6.) PIPING SHALL CONSIST OF 4" SCHEDULE 40 PVC OR EQUIVALENT. PIPE SHALL BE LAID ON A MINIMUM CONTINUOUS GRADE OF NOT LESS THAN 1%. 7.) DISTRIBUTION LINES FOR SOIL ABSORPTION SYSTEM (AS REQUIRED) SHALL BE 4" DIAMETER SCHEDULE 40 PVC LAID AT 0,005 FT/FT LINE SHALL BE CAPPED AT END OR AS NOTED. 8.) OUTLET PIPES FROM DISTRIBUTION BOX SHALL REMAIN LEVEL FOR AT LEAST 2' BEFORE PITCHING TO SOIL ABSORPTION SYSTEM. WATER TEST DISTRIBUTION BOXTO ASSURE EVEN DISTRIBUTION, 9.) DISTRIBUTION BOX SHALL HAVE A MINIMUM SUMP OF 6" MEASURED BELOW THE OUTLET INVERT 10.) BASE AGGREGATE FOR THE LEACHING FACILITY SHALL CONSIST OF 3/4" TO 1-1/2" DOUBLE WASHED NATIVE STONE FREE OF IRON, FINES AND DUST AND SHALL BE INSTALLED BELOW THE CROWN OF THE DISTRIBUTION LINE TO THE BOTTOM OF THE SOILABSORPTION SYSTEM. BASE AGGREGATE SHALL BE COVERED WITH FILTER FABRIC OR APPROVED EQUIVALENT. 11.) VENT SOIL ABSORPTION SYSTEM WHEN DISTRIBUTION LINES EXCEED 50 FEET; WHEN LOCATED EITHER IN WHOLE OR IN PART UNDER DRIVEWAYS, PARKING AREAS, TURNING AREAS OR OTHER IMPERVIOUS MATERIAL; OR WHEN PRESSURE DOSED. 12,) SOILABSORPTION SYSTEM SHALL BE COVERED WITH A MINIMUM OF 9" OF CLEAN MEDIUM SAND (EXCLUDING TOPSOIL). 13.) FINISH GRADE SHALL BE A MAXIMUM OF 36" OVER THE TOP OF ALL SYSTEM COMPONENTS, INCLUDING THE SEPTIC TANK, DISTRIBUTION BOX, DOSING CHAMBER AND SOIL ABSORPTION SYSTEM. SEPTIC TANKS SHALL HAVE A MINIMUM COVER OF 9". 14.) FROM THE DATE OF INSTALLATION OF THE SOIL ABSORPTION SYSTEM UNTIL RECEIPT OF A CERTIFICATE OF COMPLIANCE, THE PERIMETER OF THE SOIL ABSORP- TION SYSTEM SHALL BE STAKED AND FLAGGED TO PREVENT THE USE OF SUCH AREA FOR ALL ACTIVITIES THAT MIGHT DAMAGE THE SYSTEM. FLOW PROFILE: NOT TO SCALE [ TOTAL OF (3): (2) ST, (1) DB ] 21" DIAMETER CONCRETE COVERS RAISED TO WITHIN 6" OF FINISH TOP OF FOUNDATION GRADE (OR AS NOTED) EL=57.0t (SEE NOTE #5) _,.-Proposed EL=56.0t o 10" 14" •3r� 4'0" GAS BAFFLE - 1500 GALLON SEPTIC TANK SO L TEST LOGS: DEPTH FROM SURFACE (INCHES) SOIL HORIZON SOIL TEXTURE (USDA) SOIL COLOR (MUNSELL) SOIL MOTTLING OTHER 0-11 A Fine Loamy Sand 1 1OYR3 2 NONE 11-30 B Loamy Sand 10YR6 8 NONE 30-120 C1 Coarse Sand 10YR7 6 NONE PERC 62"; <2 MIN IN Ca nVLL c. LL-JJ.�- DEPTH FROM SOIL SOIL SOIL SOIL OTHER SURFACE HORIZON TEXTURE COLOR MOTTLING (INCHES) (USDA) (MUNSELL) 0-10 A Fine Loam and 10YR3 2 NONE 10-29 B Loam Sand 10YR6 8 NONE 29-120 C1 Coarse Sand 11OYR716 NONE 1 [JI nVLL J. LL-JJ•->•�- DEPTH FROM SOIL SOIL % SOIL SOIL OTHER SURFACE HORIZON TEXTURE COLOR MOTTLING (INCHES) (USDA) (MUNSELL) 0-8 A Fine Loamy Sand 10YR3 2 NONE 8-26 B Loamy Sand 10YR6 8 NONE 26-122 C1 Coarse Sand 10YR7 6 NONE PERC @ 52"' <2 MIN IN DEPTH FROM SOIL SOIL SOIL SOIL OTHER SURFACE HORIZON TEXTURE COLOR MOTTLING (INCHES) (USDA) (MUNSELL) 0-9 A Fine Loamy Sand 10YR3 2 NONE 9-27 8 Loamy Sand 10YR6 8 NONE 27-120 C1 Coarse Sand 10YR7 6 NONE DATE OF TESTING: 10/26/2023 PERCOLATION RATE: LESS THAN 2 MIN/INCH IN'CV LAYER. WITNESSED BY: ROBERT REEDY, P.E,, J.M. O'REILLY & ASSOCIATES, INC. BARRY LEWIS, YARMOUTH HEALTH DEPARTMENT NO WATER ENCOUNTERED USE A LOADING RATE OF 0.74 GPD/SF FOR SIZING OF SOIL ABSORPTION SYSTEM. SYSTEM DESIGN CALCULATIONS: 4 B,EAGE DESN DROOM D ELLIING'@ 110 GPD = 440 GPDti/ 4L_E BEDRO M 110 GPD = 440 GP REQUIRED SEPTIC TANK CAPACITY REQUIREDi 31 DAILY-F_L = 440 PD @ 200° = 880 GAL, EQUIRED SEPTIC TANK PACITY PROVIDED, 500GALLON P TANK MIN. ALLOWED) LE CHIN PACITY PROVIDEM TWO 2 9.0 X 2.0 LE C ING TRENCHES CAN LEACH: - Vt=[2][(49.0 X 2,0) + (49.0 X 2.0)2 + (2.0 X 2.0)21 X 0.74 GPD/S`1=446.96 GPD I - 4&,GPD.>_440_GPD R ED °° __ �®i NOTE: IA GARBAGE DISPOS�L IS OT ERMITTED WITH THIS DESIGN- NSTALLf"j ONE 1 - 1500-G•ACLON SEPTIC TANK ONE (1)- 3 OUTLET DISTRIBUTION BOA..tH-�O RATED TWO (2)- 49.0'X 2.0'X 2.0'LEACHINGLV_C_.,HES--- SAS DETAIL: SCALE: 1" = 10' ---------S*T.Mad£H------------ --------- SASr`FRENC+i--� -------- J TWO (2) 4" PVC INSPECTION PORTS INSPECTION NOTE: PRIORTO FINALINSPECTION BYTHE ENGINEER, SYSTEM NEEDSTO BE COMPLETE INCLUDING BUILDUP FOR COVERS. (, 53.02 y �.� 2„ 9' DB-3 D-BOX EH_ 20] EL=54.Ot Longest Run -10' D-Box 4" SCHED 40 PERFORATED PVC PIPE TWO (2) 4" PVC INSPECTION PORTS BUILT UP TO WITHIN 3" OF FINISH GRADE E L=54.0t 12" Proposed (12" Min- 36" Max) LEACHING TRENCH (2) 49.0 x 2.0' x 2.0' TRENCHES TO BE END LOADED TWO RUNS @ 49't SLOPE = 0.005 FT/FT FILTER FABRIC ROOF RUNOFF DOWNSPOUT SECTION: NOT TO SCALE PROPOSED 6" ADS HDPE'T' CONNECTION PROPOSED 6" ADS HDPE PROPOSED DOWNSPOUT (SEE ARCHITECTURAL PLANS FOR DETAILS AND LOCATIONS) ADS DOWNSPOUT ADAPTER FINISH GRADE MINIMUM 0% PITCH 6" ADS HDPE TO LEACHING -� DRIVEWAY PAVEMENT SECTION: NOT TO SCALE REQUIRED ACCESS PRUNING ZONE r (12' TALL X 14' WIDE) - - I � I � 10' (ACCESS) i 2, 20' (PARKING) 2, I I I I 'ti 1/4" PERT FOOT PITCH 1" FINISH COVER (ROLLED) 1.5 BINDER COURSE (ROLLED) 4" DENSE GRADE CRUSHED STONE BASE (14' WIDE) (MIN) 4" CLEAN SAND (SUB -BASE) ALL DRIVEWAY FILL SHALL BE CLEAN SAND PLACED IN (MAX) 6" LIFTS AND COMPACTED TO 95% DENSITY AS DETERMINED BY THE MODIFIED PROCTOR TEST 50.40 25.0't EL=20.4t PERCHED GROUNDWATER, TEST HOLES 3 AND 4, LOT 14 (8 FAITH ROAD) • rt.' 6 ADS HDPE FROM ROOF PIPE SHALL EXTEND 12" INSIDE CHAMBERS GIP ROOF RUNOFF LEACHING SECTION: NOT TO SCALE 1-1/2" WASHED STONE SURROUNDING CHAMBERS FINISH GRADE CULTEC NO, 410 NON -WOVEN GEOTEXTILE (OR APPROVED EQUAL) AROUND TOP AND SIDES OF STONE. 6" MINIMUM F NATURALLY COMPACTED FILL L--10.5' x 6.33' LEACHING FACILITY - ONE (1) CULTEC RECHARGER 330XLHD HEAVY DUTY CHAMBER WITH 1' STONE AROUND AND 6" STONE ABOVE AND BELOW.. CULTEC NO.4800 WOVEN GEOTEXTILE TO BE PLACED BENEATH ALL INLET PIPES (FOR SCOUR PROTECTION) PLAN SCALE ' ROOF RUN-OFF NOTES: 1.) ALL ROOF GUTTERS SHOULD BE DIRECTLY CONNECTED TO LEACHING FACILITIES USING 6" ADS PIPE. 2.) DWELLING SHALL UTILIZE A TOTAL OF (2) CULTEC RECHARGER 330XLHD STORMWATER LEACHING UNITS, SPLIT INTO (2)10.5' x 6.33' LEACHING FACILITIES. 3.) LEACHING FACILITIES SHALL BE SET WITHIN A CLEAN SAND BASE WITH ANY UNSUITABLE SOILS AND/OR ORGANIC MATERIAL REMOVED. CHAMBERS SHALL BE SURROUNDED BY 6" STONE ON TOP AND BOTTOM, 12' STONE ON SIDES. Ln cu W m a rn rn Y 0 0 m c cv a YARMOUTH, MA NOT TO SCALE PLAN BOOK 699 PAGE 51 DEED BOOK 35682 PAGE 239 ASSESSORS' MAP 125 PARCEL 39 LEGEND 32 EXISTING CONTOUR -32 PROPOSED CONTOUR 245 PROPOSED SPOT GRADE -W- WATER SERVICE LINE T TEST HOLE / BORING LOCATION ST SEPTIC TANK DB DISTRIBUTION BOX SAS SOILABSORPTION SYSTEM RES RESERVED FOR FUTURE ® CATCH BASIN `c7 FIRE HYDRANT S STEP BH BULKHEAD -„-x- LIMIT OF WORK _..-.- STORMWATER FLOW ARROW NOTE: SET BENCHMARK(S) DURING CONSTRUCTION, ROOF RUN-OFF LEACHING FACILITY, TYPICAL (SEE DETAILS AND NOTES) 0 20 40 60 SCALE 1"=20' G:\AAJobs\THE DAVENPORT COMPANY -ROUTE 6A-YARMOUTHPORT\DWG\8807.SDS Plans.dvA REVISED 6/11/2024: ADJUSTED GRADING AND ELEVATIONS. THE DAVENPORT COMPANIES 20 NORTH MAIN STREET, YARMOUTH, MA SITE & SEWAGE DISPOSAL SYSTEM DESIGN 9 MIRACLE WAY (LOT 10), YARMOUTHPORT, MA J.M. OTEILLY & ASSOCIATES, INC. Professional Engineering & Land Surveying Services 1573 Main Street - Route SA P.O. Box 1773 (508)896-6601 Office Brewster, MA 02631 (508)896-6602 Fax -E: SCALE: BY: CHECK: 1013 NUMBER: 12/1/2023 As Noted RFR JMO JMO-8807