HomeMy WebLinkAbout195 Rte 6A Septic Plansi T.O.F. AT EL.45.96' SEPTIC PROFI_LL__ ACCESS COVER TO WITHIN 6" OF FIN. GRADE (NOT TO SCALE) ACCESS COVER (WATERTIGHT) TO 46.5' MINIMUM .75' OF COVER OVER PRECASTWITHIN 6" OF FIN. GRADE 2% SLOPE REQUIRED OVER SYSTEM U) RUN PIPE nni 101 r uiAcurn Dr'AcrnKic . 44.0 f A PROPOSED 1500 0%FOR FIRE GALLON SEPTIC 43.59' 60 2 `T4 / TANK (H— 10 ) GAS r . TEE BAFFLE 46.32 o0000 46.15' ( 2 % SLOPE) \_6" CRUSHED STONE OR MECHANICAL COMPACTION. (15.221 [2]) DEPTH OF FLOW = 4 (1 % SLOPE) TEE SIZES: INLET DEPTH = 10 OUTLET DEPTH = 14" FOUNDATION— 8ST 5' PC 4' D' •- Mq� �L) � 22.75' 2.7 5�� -43\4' 2 J 21' 2' f 2'-- 2' GAS_;' SHUTOFF ; ; ; 1 4' ; LEACH FIELD DETAIL (NTS) i ; N; PROD, i ANDSCAP;- TIE BERM AT END OF 6' DRIVEWAY i OO; i D 40 i48 Cv i / 18" 0 i 49, �(�1 i i / HED i 14' i OAK v 1C ; i ; `1 DIRT PARKING\ AREA , i i •� 99-078 N STREET � R - OU rE gq 41.5' AVID SIB ` � fpGe OF pA�MfNT 42'S0 STOVE VARIANCES REQUESTED UNDER MAXIMUM FEASIBLE W Lt COMPLIANCE 15.405: 1 a: REQUEST VARIANCE TO SET1= ACK FROM ROPERTY LINE (10' TO 4' FOR PUMP CHAMBER; 47.5' — 48.5' TEST HOLE LOGS ENGINEER: AH OJALA, PE WITNESS: AMY VON HONE, RS & BRUCE MURPHY, RS DATE: 4/26/99 PERC. RATE _ < 2 MIN/INCH IN MS CLASS I &III SOILS P# w ELEV. 0" 48.5' 0" A SL 12" 1OYR 3/2 B'� LS 32" 1OYR 5/ 45.83' C1 MS 2.5Y 6/6 84/ 41.5' 10' TO 4.5' FOR LEACHING FIELD) C2 N SILT LOAM I lb: REQUEST VARIANCE TO SET!=SACK FROM FENIOF� FOUNDATION (10' TO 6' FOR SEPTIC TANK) 2.5Y 6/2 j 5' REMOVAL OF UNSUITABLE SOIL MAY BE REQUIRED AT NORTHERLY END OF SYSTEM. E.N_GJNEER TO INSPECT _AND CERTIFY REMOVAL a PICKET FENCE 4't / 6" LOCUST -" *WATERLINE LOCATION APPROXIMATE ONLY 132" 1 1 37.5' NO WATER ENCOUNTERED SEPTIC DESIGN: (GARBAGE DISPOSER IS NOT ALLOWED ) DESIGN FLOW: 3 BEDROOMS ( 110 GPD) = 330 GPD USE A 330 GPD DESIGN FLOW SEm � " "'K: 330 GPD ( 2 ) = 660 USE A 1500 GALLON SEPTIC TANK LEACHING: SIDES: N/A BOTTOM: 21 x 22.75 (.74) 353 TOTAL: 477 S.F. 353 GPD USE 21' x 22.75' LEACH FIELD OF 3 ROWS OF 3 STANDARD INFILTRATORS EACH IN CONFIGURATION SHOWN (SEE DETAIL) LEGEND NOTE: SYSTEM IS NOT DESIGNED FOR VEHICLE LOADING 100.0 PROPOSED SPOT ELEVATION 100x0 EXISTING SPOT ELEVATION O PROPOSED CONTOUR 100 EXISTING CONTOUR BOARD OF HEALTH ALARM AND CONTROL PANEL J MA ) TO BE INSTALLED INSIDE 13, Q BUILDING. ALARM TO BE ON INV. IN 43.54' SEPARATE CIRCUIT FROM PUMP 2" PRESSURE PIPE TO D'BOX APPROVED DATE 1000 GAL. H-10 S/ ALARM ON 800 GAL.- RESERVE WEEP HOLE FLOAT SWITCH SETTINGS: PUMP ON CHECK VALVE off 508-362-4541 fox 508 362-9880 4' WORKING RANGE 8' ZOELLER 'WASTEMATE' 4' SUBMERSIBLE MODEL M282 112 'tP PUMP PUMP OFF 4' SYSTEM (OR EQUAL) down cape engineering, Inc. BENCHMARK PUMP CHAMBER CIVIL' ENGINEERS CONCRETE BOUND (NOT TO SCALE) LAND SURVEYORS ELEV = 54.74' 939 main st. yarmouth, ma 02675 Q rte. 6a 3 3 N LOCUS LOCATION MAP ASSESSORS MAP"-122 PARCEL 109 ZONING DISTRICT: YARD SETBACKS: FRONT = SIDE = REAR = PLAN REF. — NO PLAN OF RECORD FLOOD ZONE: C NOTES: 1. DATUM IS APPROXIMATED FROM DE-NNIS QUAD 2. MUNICIPAL WATER IS EXISTING 3. MINIMUM PIPE PITCH TO BE 1 /8" PER FOOT. 4. DESIGN LOADING FOR ALL PRECAST UNITS TO BE AASHO H— 10 5. PIPE JOINTS TO BE ifADE WAT EPTIGHT. 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH MASS. ENVIRONMENTAL CODE TITLE V. 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO BE USED FOR LOT LINE STAKING. 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC. 9, COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITH❑UT INSPECTI❑N BY BOARD OF HEALTH AND PERM SSSI❑N ❑BTAINED FROM BOARD OF HEALTH, 10. PUMP & REMOVE EXISTING CESSPOOLS. !j__,_F_LECTR I CAL PERMIT REQUIRED 12. WATER TEST D'BOX FOR LEVELNESS SI TE AND SEVAG E-PL.,AN OF 195 MAIN ST. (ROUTE 6A) IN THE TOWN OF: YARMOUTH (PORT) PREPARED FOR: MICHAEL AND LINDA DILLON 34W--7'P5 _ 20 0 20 40 60 Feet 1" = 20' APRIL 27, 1999 SCALE: DATE: G EECl-E0wF=0 �`iH of �, APR 3 0 1999 P0H Of Mq g4� ARNEli.�� o`�ARNE a�cyE�LTS �Po v OJA(.A )CIVIL.30792 U q /STERE �� ECIST4A JALA, LAN ,S, DATE