HomeMy WebLinkAbout5209 177 Seaview Ave Architectural Plans 11.26.25Scale Project number Date Drawn by Checked byWWW.MORELORTA.COM INFO@MORELORTA.COM 11/26/2025 4:31:44 PMA-00 COVER PAGE 173177 Seaview Ave South Yarmouth, MA 02664 SECOND FLOOR DORMER 11.26.25 MO DS PROJECT DESCRIPTION: DESIGN OF A NEW DORMER ON THE SECOND FLOOR OF THE EXISTING SINGLE FAMILY HOME. ALL OF THE WORK SHOULD COMPLY WITH 780 CMR 10TH EDITION AND ALL APPLICABLE ZONING ORDINANCES. NUMBER OF BEDROOMS IS INCREASING TO 3 TOTAL AS ALLOWED BY THE SEPTIC CAPACITY OF THE HOME. THE COST OF CONSTRUCTION IS LIMITED TO LESS THAN 50% THE COST OF THE EXISTING DWELING WITHOUT REQUIRING UPGRADES ON FLOOD ELEVATIONS. 177 SEAVIEW AVE SOUTH YARMOUTH, MA 02664 REVISED PERMIT SET - 11.26.2025 2 2 FIRE/CO2 ALARM NOTE: CARBON MONOXIDE ALARMS AND COMBINATION ALARMS SHALL RECEIVE THEIR PRIMARY POWER FROM THE BUILDING WIRING WHERE SUCH WIRING IS SERVED FROM A COMMERCIAL SOURCE AND, WHERE PRIMARY POWER IS INTERRUPTED, SHALL RECEIVE POWER FROM A BATTERY. WIRING SHALL BE PERMANENT AND WITHOUT A DISCONNECTING SWITCH OTHER THAN THOSE REQUIRED FOR OVER CURRENT PROTECTION. ALARMS MAY ALSO BE PART OF A LOW VOLTAGE OR WIRELESS SYSTEM WITH STANDBY POWER FROM MONITORED BATTERIES IN ACCORDANCE WITH NFPA 72 WHEN MORE THAN 12 SMOKE ALARMS ARE INSTALLED, MONITORED SYSTEM-TYPE DEVICES MUST BE UTILIZED (780 CMR 5313.2.1). THIS SYSTEM-TYPE HOUSEHOLD FIRE WARNING SYSTEM MUST BE WIRED AS BELOW IN #6 (780 CMR 5313.2.5.2). PRIMARY ELECTRICAL POWER FOR SINGLE AND MULTI-STATION DEVICES SHALL BE SUPPLIED FROM A PERMANENTLY WIRED CONNECTION DIRECTLY TO AN AC PRIMARY POWER SOURCE. THIS CAN BE EITHER: A DEDICATED LOCKED BRANCH CIRCUIT OR A SINGLE BRANCH CIRCUIT WHICH ALSO PROVIDES OTHER ELECTRICAL SERVICE TO A HABITABLE SPACE (780 CMR 5313.2.5.1). EXISTING UNFINISHED BASEMENT TO REMAIN 32' - 0"24' - 0"Location of combination smoke and carbon monoxide (CO) alarms listed in accordance with UL 217 and UL 2034. EQEQFIREPLACEREPLACE FAILING BLOCK FOUNDATION WITH CAST IN PLACE FOUNDATION AS SHOWN. TOP OF FOUNDATION WALL TO BE +14' AND BOTTOM OF TRIPLE BEAM TO BE ELEVATON +13, WHICH IS 2' FEET ABOVE FLOOD ELEVATION ZONE AE +11' REPLACE EXISTING LALLY FOR NEW TALLER ONE. REFER TO A-12 FOR MORE INFORMATION Scale Project number Date Drawn by Checked by 1/4" = 1'-0" A-01 FOUNDATION PLAN 173 11.26.25 MO DS Location of combination smoke and carbon monoxide (CO) alarms listed in accordance with UL 217 and UL 2034. KITCHEN BEDROOM #1 FULL BATHROOM CLOSET 24' - 0"15' - 0"17' - 0" BEDROOM #2 CLOSET 16' - 2"EQEQ11' - 0"3' - 0" 32' - 0"11' - 4"LIVING 32' - 0"24' - 0"FIREPLACE min distance from stove to alarm 10' - 2" DN EXISTING BACK DECK TO REMAIN EXISTING EXIT HATCH TO REMAIN NEW STAIR CONNECTING THE GROUND FLOOR WITH THE SECOND FLOOR. STAIR TO BE WOOD WITH 2X12 STRINGERS SPACED AT 16" O.C. STAIR WIDTH TO HAVE A MIN CLEAR DIMENSION OF 36", WITH 8.25" MAX RISERS AND 10" MIN TREADS. WOOD RAILING REQUIRED ON ONE SIDE MIN WITH A 36" HEIGHT AFF. STAIR IS INTENDED TO STACK ABOVE EXISTING BASEMENT STAIR3' - 0"GROUND FLOOR AREA TO REMAIN UNCHANGED 768 SF Scale Project number Date Drawn by Checked by 1/4" = 1'-0" A-02 GROUND FLOOR PLAN 173 11.26.25 MO DS PROPOSED BEDROOM (#3) SECOND FLOOR AREA 574 SF Location of combination smoke and carbon monoxide (CO) alarms listed in accordance with UL 217 and UL 2034. 11' - 0"14' - 0"3' - 6"FIREPLACE MASTER CLOSET 5' - 0"IN HOUSE OFFICE STORAGE CLOSET 8' - 0" PROPOSED BATHROOM10:129' - 10"15' - 2"32' - 0" 32' - 4"25' - 0"32' - 4"25' - 0"9' - 10"15' - 2"16' - 2" 7' - 9" DN 4' - 9"4' - 9"8' - 0"6' - 6"8' - 0" 3' - 0" NEW STAIR CONNECTING THE GROUND FLOOR WITH THE SECOND FLOOR. STAIR TO BE WOOD WITH 2X12 STRINGERS SPACED AT 16" O.C. STAIR WIDTH TO HAVE A MIN CLEAR DIMENSION OF 36", WITH 8.25" MAX RISERS AND 10" MIN TREADS. WOOD RAILING REQUIRED ON ONE SIDE MIN WITH A 36" HEIGHT AFF. STAIR IS INTENDED TO STACK ABOVE EXISTING BASEMENT STAIR COORDINATE SHAFTS WITH HVAC DURING CONSTRUCTIONactual opening8' - 7"distance from low wall4' - 7"IMAGES OF WALL BY STAIR. OFFICE AREA IS OPEN Scale Project number Date Drawn by Checked by 1/4" = 1'-0" A-03 SECOND FLOOR PLAN 173 11.26.25 MO DS ASTM D3462 FIBERGLASS ASPHALT SHINGLES 10:1210:1212' - 6"12' - 6"25' - 0"32' - 4"12' - 6"12' - 6"25' - 0"3:123:1232' - 4" CHIMNEY Scale Project number Date Drawn by Checked by 1/4" = 1'-0" A-04 ROOF PLAN 173 11.26.25 Author Checker FIRST FLOOR 15' - 0" SECOND FLOOR 24' - 0"9' - 10"9' - 0"ASTM D3462 FIBERGLASS ASPHALT SHINGLES TO MATCH EXISTING TOP OF EXISTING 29' - 4" 0.625” X 10.25” HARDIE PLANK SIDING (FIBER CEMENT) TO MATCH EXISTING 4' - 6"14' - 4"10:123:12 10 : 1 2 CURRENT ROOFLINE T.O.P 33' - 10" 6:12 6:12 TOP OF FOUNDATION 14' - 0"BOTTOM OF STRUCTURE 13' - 0" FLOOD ELEVATION AE 11' - 0" Scale Project number Date Drawn by Checked byWWW.MORELORTA.COMINFO@MORELORTA.COM 1/4" = 1'-0"11/26/2025 4:31:51 PMA-05 NORTH ELEVATION 173177 Seaview Ave South Yarmouth, MA 02664 SECOND FLOOR DORMER 11.26.25 MO DS FIRST FLOOR 15' - 0" SECOND FLOOR 24' - 0" TOP OF ADDITION 27' - 4" TOP OF EXISTING 29' - 4"9' - 10"9' - 0"T.O.P 33' - 10" ASTM D3462 FIBERGLASS ASPHALT SHINGLES TO MATCH EXISTING 0.625” X 10.25” HARDIE PLANK SIDING (FIBER CEMENT) TO MATCH EXISTING 18' - 10"TOP OF FOUNDATION 14' - 0"BOTTOM OF STRUCTURE 13' - 0" FLOOD ELEVATION AE 11' - 0" Scale Project number Date Drawn by Checked byWWW.MORELORTA.COMINFO@MORELORTA.COM 1/4" = 1'-0"11/26/2025 4:31:52 PMA-06 WEST ELEVATION 173177 Seaview Ave South Yarmouth, MA 02664 SECOND FLOOR DORMER 11.26.25 MO DS FIRST FLOOR 15' - 0" SECOND FLOOR 24' - 0" TOP OF EXISTING 29' - 4"14' - 4"4' - 6"ASTM D3462 FIBERGLASS ASPHALT SHINGLES TO MATCH EXISTING 0.625 ” X 10.25 ” HARDIE PLANK SIDING (FIBER CEMENT) TO MATCH EXISTING T.O.P 33' - 10" CURRENT ROOFLINE 3:12 10 : 1 210:126:12 6:12 18' - 10"TOP OF FOUNDATION 14' - 0"BOTTOM OF STRUCTURE 13' - 0" FLOOD ELEVATION AE 11' - 0" Scale Project number Date Drawn by Checked byWWW.MORELORTA.COMINFO@MORELORTA.COM 1/4" = 1'-0"11/26/2025 4:31:54 PMA-07 SOUTH ELEVATION 173177 Seaview Ave South Yarmouth, MA 02664 SECOND FLOOR DORMER 11.26.25 MO DS FIRST FLOOR 15' - 0" SECOND FLOOR 24' - 0" TOP OF EXISTING 29' - 4" T.O.P 33' - 10"9' - 10"9' - 0"18' - 10"ASTM D3462 FIBERGLASS ASPHALT SHINGLES TO MATCH EXISTING TOP OF FOUNDATION 14' - 0"BOTTOM OF STRUCTURE 13' - 0" FLOOD ELEVATION AE 11' - 0" Scale Project number Date Drawn by Checked byWWW.MORELORTA.COMINFO@MORELORTA.COM 1/4" = 1'-0"11/26/2025 4:31:55 PMA-08 EAST ELEVATION 173177 Seaview Ave South Yarmouth, MA 02664 SECOND FLOOR DORMER 11.26.25 MO DS 10:1210:1212' - 6"12' - 6"25' - 0"32' - 4"12' - 6"12' - 6"2X10 WOOD RAFTERS AT 16" O.C. TYP. R-49 MIN INSULATION REQ'D 2X12 WOOD RIDGE TYP 2X10 RIM BOARD 3:123:1232' - 4" CHIMNEY Scale Project number Date Drawn by Checked by 1/4" = 1'-0" A-09 ROOF FRAMING PLAN 173 11.26.25 Author Checker FIRST FLOOR 15' - 0" SECOND FLOOR 24' - 0" TOP OF EXISTING 29' - 4" T.O.P 33' - 10"4' - 6"5' - 4"9' - 0"18' - 10"0' - 8"0' - 8"0' - 8"0' - 8"0' - 10" 0' - 10" 0' - 10" 3' - 0 "8' - 0"10:123:12 2X10 WOOD RAFTERS AT 16" O.C. TYP. R-49 MIN INSULATION REQ'D 2X12 WOOD RIDGE TYP 2X10 RIM BOARD 2X8 WOOD COLLAR TIES AT 16" O.C. TYP. 2X6 WOOD JOISTS AT 16" O.C. TYP. R-30 MIN INSULATION REQ'D ON ALL NEW EXTERIOR WALLS 2X10 WOOD JOISTS AT 16" O.C. TYP. EXISTING TO REMAIN EXISTING 2X10 WOOD JOISTS AT 16" O.C. TYP. EXISTING TO REMAIN. R-30 MIN INSULATION REQUIRED ON FLOORS OUTLINE OF OLD ROOF TOP OF FOUNDATION 14' - 0" BOTTOM OF STRUCTURE 13' - 0" FLOOD ELEVATION AE 11' - 0"1' - 0"1' - 0"2' - 0"Scale Project number Date Drawn by Checked byWWW.MORELORTA.COM INFO@MORELORTA.COM 3/8" = 1'-0"11/26/2025 4:31:58 PMA-10 BUILDING SECTION 173177 Seaview Ave South Yarmouth, MA 02664 SECOND FLOOR DORMER 11.26.25 MO DS Scale Project number Date Drawn by Checked byWWW.MORELORTA.COM INFO@MORELORTA.COM 11/26/2025 4:31:58 PMA-11 CONSTRUCTION DETAILS 173177 Seaview Ave South Yarmouth, MA 02664 SECOND FLOOR DORMER 11.26.25 Author Checker Scale Project number Date Drawn by Checked byWWW.MORELORTA.COM INFO@MORELORTA.COM 11/26/2025 4:32:00 PMA-12 SCHEDULES & NOTES 173177 Seaview Ave South Yarmouth, MA 02664 SECOND FLOOR DORMER 11.26.25 MO DS • WINDOW SCHEDULE: (6) 30X46 EXTERIOR TEMPERED GLASS (WITH GRILLS INSIDE OF GLASS OPTION) DOUBLE HUNG ANDERSEN A-SERIES OR 400 SERIES Scale Project number Date Drawn by Checked byWWW.MORELORTA.COMINFO@MORELORTA.COM 11/26/2025 4:32:01 PMA-13 REFERENCE IMAGES 173177 Seaview Ave South Yarmouth, MA 02664 SECOND FLOOR DORMER 11.26.25 MO DS 0.625” X 10.25” HARDIE PLANK SIDING (FIBER CEMENT)- ARCHITECTURAL ½” EXTERIOR PLYWOOD 2X6'S@ 16"O.C ON WALLS. R-30 COMPRESSED FIBERGLASS INSULATION ON WALLS AND R-49 ON ROOFS 6 MIL POLYETHYLENE VAPOR BARRIER 1/2” GYPSUM DRYWALL 1 X 4 BEADED BOARD AT ALL SOFFITS ASTM D3462 FIBERGLASS ASPHALT SHINGLES PROPOSED DORMER IN THE BACK Scale Project number Date Drawn by Checked byWWW.MORELORTA.COMINFO@MORELORTA.COM 11/26/2025 4:32:02 PMA-14 FEMA FLOOD MAP 173177 Seaview Ave South Yarmouth, MA 02664 SECOND FLOOR DORMER 11.26.25 MO DS