Loading...
HomeMy WebLinkAboutSite and Sewage Design PlanGENERAL NOTES: A.) NEITHER DRIVEWAYS NOR PARKING AREAS ARE ALLOWED OVER SEPTIC SYSTEM UNLESS H-20 COMPONENTS ARE USED. B.) THE DESIGNER WILL NOT BE RESPONSIBLE FOR THE SYSTEM AS DESIGNED UN- LESS CONSTRUCTED AS SHOWN. ANY CHANGES SHALL BE APPROVED IN WRITING. C.) CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING THE LOCATION OF ALL UNDERGROUND AND OVERHEAD UTILITIES PRIOR TO COMMENCEMENT OF WORK. CONSTRUCTION NOTES: 1.) ALL CONSTRUCTION SHALL CONFORM TO THE STATE ENVIRONMENTAL CODE, TITLE 5,AND THE REQUIREMENTS OF THE LOCAL BOARD OF HEALTH. 2.) SEPTIC TANK(S), GREASE TRAP(S), DOSING CHAMBER(S) AND DISTRIBUTION BOX(ES) SHALL BE SET ON A LEVEL STABLE BASE WHICH HAS BEEN MECHANICALLY COMPACTED, OR ON A 6 INCH CRUSHED STONE BASE. 3.) SEPTIC TANK(S) SHALL MEET ASTM STANDARD C1127-93 AND SHALL HAVE AT LEASTTHREE 20" DIAMETER MANHOLES. THE MINIMUM DEPTH FROM THE BOT- TOM OF THE SEPTIC TANK TO THE FLOW LINE SHALL BE 48". 4.) SCHEDULE 40 PVC INLET AND OUTLET TEES SHALL EXTEND A MINIMUM OF 6" ABOVE THE FLOW LINE OF THE SEPTIC TANK AND SHALL BE INSTALLED ON THE CENTERLINE OF THE TANK DIRECTLY UNDER THE CLEANOUT MANHOLE. 5.) RAISE COVERS OF THE SEPTIC TANK AND DISTRIBUTION BOX WITH PRECAST CONCRETE WATER TIGHT RISERS OVER INLET AND OUTLET TEES TO WITHIN 6" OF FINISH GRADE, OR AS APPROVED BY THE LOCAL BOARD OF HEALTH AGENT. 6.) PIPING SHALL CONSIST OF 4" SCHEDULE 40 PVC OR EQUIVALENT, PIPE SHALL BE LAID ON A MINIMUM CONTINUOUS GRADE OF NOT LESS THAN 1%. 7.) DISTRIBUTION LINES FOR SOIL ABSORPTION SYSTEM (AS REQUIRED) SHALL BE 4" DIAMETER SCHEDULE 40 PVC LAID AT 0.005 FT/FT. LINE SHALL BE CAPPED AT END OR AS NOTED. 8.) OUTLET PIPES FROM DISTRIBUTION BOX SHALL REMAIN LEVEL FOR AT LEAST 2' BEFORE PITCHING TO SOIL ABSORPTION SYSTEM, WATER TEST DISTRIBUTION BOXTOASSURE EVEN DISTRIBUTION. 9.) DISTRIBUTION BOX SHALL HAVE A MINIMUM SUMP OF 6" MEASURED BELOW THE OUTLET INVERT. 10.) BASE AGGREGATE FOR THE LEACHING FACILITY SHALL CONSIST OF 3/4" TO 1-1/2" DOUBLE WASHED NATIVE STONE FREE OF IRON, FINES AND DUST AND SHALL BE INSTALLED BELOW THE CROWN OF THE DISTRIBUTION LINE TO THE BOTTOM OF THE SOILABSORPTION SYSTEM. BASE AGGREGATE SHALL BE COVERED WITH FILTER FABRIC OR APPROVED EQUIVALENT. 11.) VENT SOILABSORPTION SYSTEM WHEN DISTRIBUTION LINES EXCEED 50 FEET, WHEN LOCATED EITHER IN WHOLE OR IN PART UNDER DRIVEWAYS, PARKING AREAS, TURNING AREAS OR OTHER IMPERVIOUS MATERIAL,- OR WHEN PRESSURE DOSED. 12.) SOIL ABSORPTION SYSTEM SHALL BE COVERED WITH A MINIMUM OF 9" OF CLEAN MEDIUM SAND (EXCLUDING TOPSOIL). 13.) FINISH GRADE SHALL BE A MAXIMUM OF 36" OVER THE TOP OF ALL SYSTEM COMPONENTS, INCLUDING THE SEPTIC TANK, DISTRIBUTION BOX, DOSING CHAMBER AND SOILABSORPTION SYSTEM. SEPTIC TANKS SHALL HAVE A MINIMUM COVER OF 9". 14.) FROM THE DATE OF INSTALLATION OF THE SOIL ABSORPTION SYSTEM UNTIL RECEIPT OF A CERTIFICATE OF COMPLIANCE, THE PERIMETER OF THE SOIL ABSORP- TION SYSTEM SHALL BE STAKED AND FLAGGED TO PREVENT THE USE OF SUCH AREA FOR ALL ACTIVITIES THAT MIGHT DAMAGE THE SYSTEM. SAS DETAIL: SCALE: 1" = 10' SO L TEST LOGS: TCCT Urll C 'I . CI -C7 7-L DEPTH FROM SURFACE (INCHES) SOIL HORIZON SOIL TEXTURE (USDA) SOIL COLOR (MUNSELL) SOIL MOTTLING OTHER 0-10 A Fine Loamy Sand 10YR3 2 NONE 10-26 B Loa mV Sand 10YR6 8 NONE 26-132 Cl Coarse Sand 10YR7 6 NONE PERC @ 68"• <2 MIN IN r' 1. 11 _C7 71 DEPTH FROM SURFACE (INCHES) SOIL HORIZON SOIL TEXTURE (USDA) SOIL COLOR (MUNSELL) SOIL MOTTLING OTHER 0-8 A Fine LoamV Sand 10YR3 2 NONE 8-24 B Loamy Sand 10YR6 8 NONE 24-132 C1 Coarse Sand 10YR7 6 NONE TILT 11/11 I I. CI -CC 01 DEPTH FROM SURFACE (INCHES) SOIL HORIZON SOIL TEXTURE (USDA) SOIL COLOR (MUNSELL) SOIL MOTTLING OTHER 0-8 A Fine Loamy Sand 10YR3 2 NONE 8-22 B Loamy Sand 10YR6 8 NONE 22-132 Cl Coarse Sand 10YR7 6 NONE PERC @ 76"; <2 MIN IN TCCT IJr l C A. Cl -Cr Q4. DEPTH FROM SURFACE (INCHES) SOIL HORIZON SOIL TEXTURE (USDA) SOIL COLOR (MUNSELL) SOIL MOTTLING OTHER 0-9 A Fine Loamy Sand 10YR3 2 NONE 9-24 B Loamy Sand 10YR6 8 NONE 24-132 Cl Coarse Sand 10YR7 6 NONE DATE OF TESTING: 10/25/2023 PERCOLATION RATE: LESS THAN 2 MIN/INCH IN'C1' LAYER. WITNESSED BY: ROBERT REEDY, P.E., J.M. O'REI-LY & ASSOCIATES, INC. BARRY LEWIS, YARMOUTH HEALTH DEPARTMENT NO WATER ENCOUNTERED USE A LOADING RATE OF 0.74 GPD/SF FOR SIZING OF SOIL ABSORPTION SYSTEM, SYSTEM DESIGN CALCULATIONS: EWAGE DESIGN F�REQUII €f2�0 M D E GP 440� LEACHING CAPAM 4 BEDROOMS (MAX.)@ 110 GPD = 0 GPD RE IRED SEPTIC TANK CAPACITY REQUIRED. DAILY FLOW = PD 0% = 880 GA . REQUIRED SEPTIC TANK CA ACITY PROVIDEM 1500 GLLON SEPTIC TANK MIN.ALLOWED) LEACH NGA'PACITY PROVIDEDi ONE .5 1 X 2.0 LEACHING CHAMBER CAN LEACH: Vt=[(33.5 X 12.83) + (33.5 X 2.0)2 + (12.83 X 2.C)2) X 0.74 GPD/SF=455.10 GP 455 GPD>440 D RE IRED NOTE: A(GARBAGE DISPO)5 L NOT PERMITTED WITH THIS DESIGN. INSTALLL__ ` ONE 1-156�4flf�1SEPTICTANK ONE (1), 3 0)1.ITLET DISTRIBUTION BOX (H-20 RATED) THREE (300 GALLON LEACH CHAMBERS WITH 4' OF NATIVE STONE ALL AROUND ROOF RUNOFF DOWNSPOUT SECTION: NOT TO SCALE PROPOSED 6" ADS H DPE 'T' CONNECTION PROPOSED 6" ADS HDPE 9C PROPOSED DOWNSPOUT (SEE ARCHITECTURAL PLANS FOR DETAILS AND LOCATIONS) ADS DOWNSPOUT ADAPTER FINISH GRADE MINIMUM 0% PITCH 6" ADS HDPE TO LEACHING -_ DRIVEWAY PAVEMENT SECTION: 6" ADS HDPE FROM ROOF PIPE SHALL EXTEND 12" INSIDE CHAMBERS NOT TO SCALE _REQ_Ul_RED_ACCE_SS_PRUN/NG_ZO_NE_ (12' TALL X 14' W/DEJ I I I i 10' (ACCESS) ! �� 2, 20' (PARKING) 21 SRO 1/4" PER FOOT PITCH 1" FINISH COVER (ROLLED) 1.5 BINDER COURSE (ROLLED) 4" DENSE GRADE CRUSHED STONE BASE (14' WIDE) (MIN) 4" CLEAN SAND (SUB -BASE) ALL DRIVEWAY FILL SHALL BE CLEAN SAND PLACED IN (MAX) 6" LIFTS AND COMPACTED TO 95% DENSITY AS DETERMINED BY THE MODIFIED PROCTOR TEST SWALE DETAIL: NOT TO SCALE FLOW PROFILE: NOT TO SCALE [ TOTAL OF (4): (2) ST, (1) DB, (1) SAS ) 21" DIAMETER CONCRETE COVERS RAISED TO WITHIN 6" OF TOP OF FOUNDATION FINISH GRADE (OR AS NOTED) 1 � EL=59.0± (SEE NOTE #5) f Proposed EL=57.0± U-I3UA ) COVER TO BE BUILT UP TO WITHIN 6" OF FINISH GRADE INSPECTION NOTE: PRIORTO FINAL INSPECTION BY THE ENGINEER, SYSTEM NEEDS TO BE COMPLETE INCLUDING BUILDUP FOR COVERS. sed EL=57.0± \ r- Proposed EL=57.0± PERMEABL (50% SAND, 50% [ FILTER F 3/4" TO 1-1/2". NATIVE SOIL SUB -BASE - FREE FROM LOAM / ORGANIC MATERIAL q 55 7+ 36" Proposed (9" Min- 36" Max) 54.0± FILTER FABRIC 56.00 4.50 10" 14" 54.2 53.25 3/4"- 1-1/2" NATIVE STONE 3" T T 53.75 53.58 ^' r-i 4'0" I 2" DROP GAS BAFFLE 51.25 USE THREE (3) SHOREY PRECAST 500GALLON LEACH CHAMBERS Longest Run WITH 4' OF NATIVE STONE AROUND 31' 15' 15 (END VIEW) 1500 GALLON DB-3 iEL=20.4± PERCHED GROUNDWATER, SEPTIC TANK D-BOX LEACHING CHAMBER TEST HOLES 3 AND 4, LOT 14 (8 FAITH ROAD) 33.5' x 12.83' x 2.0' H-20 ROOF RUNOFF LEACHING SECTION: NOT TO SCALE 1-1/2" WASHED STONE SURROUNDING CHAMBERS FINISH GRADE CULTEC NO. 410 NON -WOVEN GEOTEXTILE (ORAPPROVED EQUAL) AROUND TOP AND SIDES OF STONE. 6" MINIMUM NATURALLY COMPACTED FILL �-10.5' x 6.33' LEACHING FACILITY - ONE (1) CULTEC RECHARGER 330XLHD HEAVY DUTY CHAMBER WITH 1' STONE AROUND AND 6" STONE ABOVE AND BELOW.. CULTEC NO.4800 WOVEN GEOTEXTILE TO BE PLACED BENEATH ALL INLET PIPES (FOR SCOUR PROTECTION) ROOF RUN-OFF NOTES: 1.) ALL ROOF GUTTERS SHOULD BE DIRECTLY CONNECTED TO LEACHING FACILITIES USING 6" ADS PIPE. 2.) DWELLING SHALL UTILIZE A TOTAL OF (2) CULTEC RECHARGER 330XLHD STORMWATER LEACHING UNITS, SPLIT INTO (2) 10.5' x 6.33' LEACHING FACILITIES. 3.) LEACHING FACILITIES SHALL BE SET WITHIN A CLEAN SAND BASE WITH ANY UNSUITABLE SOILS AND/OR ORGANIC MATERIAL REMOVED. CHAMBERS SHALL BE SURROUNDED BY 6" STONE ON TOP AND BOTTOM, 12' STONE ON SIDES, .4- LOT 2 s� f \ OPEN SPACE IN TP2 \ TP1 O �� f 9 1z' J TP4 \�'� f _ / -P3 f � A x LOT 3 x 14,070 SF± I sU0 x I I 5 0 Ln Ln ko ,^ O f .' OPEN SPACE \ STORMWATER SWALE (SE; DETAIL) ROOF RUN-OFF LEACHING FACILITY, TYPICAL \_ (SEE DETAILS AND NOTES) P LAN SCALE HEALTH IDEP PY�N OF Mgss �PXZN OF Miss tiG JOHN tiN g JOHN M. cP M. O'REILLY 4 o O'REILLY CIVIL o NC), 46733 NO. 36200 - Q n 0 20 40 60 SCALE 1"=20' G:\AAJobs\THE DAVENPORT COMPANY -ROUTE 6A-YARMOUTHPORT\DWG\8807.SDS Plans.dwg Ln v an m a rn rn 0 0 m c m a-