HomeMy WebLinkAboutBLDC-25-57 G EOSCIENCES TESTING AND RESEARCH,INC. 1 Will 55 Middlesex Street,Suite 225,N.Chelmsford,MA 01863 III I�I:• Ph:(978)251-9395 www.grrinc.ner GTR / ��,f` DAILY FIELD REPORT ENGINEERING SINCE 1995 Project Name:Riverwalk Park Restroom Facility �n49 % ,QIL Report It 1 Project Locatic West Yarmouth,Massachusetts Date: 9/16/2025 Job Number: 25.257 Weather: Partly Cloudy,70s GTR PERSONNEL CONTRACTORS NAME ON-SITE TRAVEL OFFICE TOTAL NAME POSITION ORGANIZATION Christopher A.Jones 2 5.5 1 8.5 Justin Spurr Superintendent Robert 8.Our Rob Doane Project Manager Robert B.Our Bill Dotolo Project Manager B&B Commercial Masonry ON-SITE ACTIVITIES OBSERVED FIELD EQUIPMENT/MATERIALS 1 Inspection of CMU Walls WORK PERFORMED GTR Representative Christopher Jones arrived on-site at 0845 to perform inspection of the CMU walls for the restroom facility at the above referenced project as requested by Robert B.Our Co. During the inspection,several items were identified as needing correction.A list of the items discussed follows: 1.Vertical reinforcement shall be provided at 32-inches on center and extend the full height of the walls.Splices,where required,shall have a minimum lap splice length of 24 inches with vertical bars extending out of the footing. 2.Corner reinforcement shall consist of 2 tt4 reinforcement bars bent at90 degrees and provide a minimum lap splice of 24 inches with both k4 horizontal bond beam reinforcement bars in both directions.Add corner reinforcement as discussed herein to the upper 3 bond beams.The corners of the bond beam directly above the foundation(first course of CMU)shall remain as is.Provide reinforcement ties to ensure sections of reinforcement do not move during grouting.See figure 1 for example of improper corner reinforcement and figure 2 for example location requiring ties. 3.Lap splice lengths within the bond beams shall be a minimum of 24 inches and reinforcement used within the bond beams shall be as long as possible(i.e.the number of splices in the bond beams shall be minimized).See figure 3 for example of inadequate lap splice length. 4.Cleanout windows shall be provided in accordance with TMS 602 requirements when grout lift heights exceed 5 ft 4in.First lift shall be to the bottom of the lowest bond beam that is more than 5ft-4in above bottom of grout lift(TMS 602 Specification 3.5 Grout Placement—Section 3.5 D 1.b.).The locations where CMU block extends full height without openings will require cleanouts at 32 inches on center.Provide a cleanout window in the second course of block to avoid cutting into the first course bond beam.See figure 4 for typical CMU wall which requires cleznouts. 5.One additional vertical N5 bar shall be provided on each side of door openings(i.e.first two cells of block on each side of door openings shall have one full height 05 vertical bar). These items were discussed with representatives from Robert B.Our and B&B Commercial Masonry. Mr.Jones left the site at 1045. CHANGES/INFORMATION RECEIVED/INFORMATION REQUESTED ATTACHMENTS Figures 1 through 4. Prepared By: Christopher A.Jones,P.E.(NY) Reviewed By: Mark J.Champagne,PE A 1 , - _____:�__ ENGINEERING SINCE 1995 GTP , , . , _ _, r 't �,, V'�" ', r ; Y� t 4 ,fir a'rt�,M S r a "a. � 4,,,, r , ,,, � 1,10% .,,,,_ 5 � �� "� + •'` .tilt Ai, A' � �;r . _ s,,,,, ,,,,,,,,,,,,,...,,,,,":,:,,,,,,,,,,:‘,4,„,,::::,::•,,,,,,,:—,:::...;,..,..:::::‘,.:„.,,,,,,,,,,,,,,,v-:11,,,,:,,, -,,,,,„..,,,:::::,..7.-: . a '" • • k,' ' , ' x a �\ a � ,`a Z a F '`asap ..._ x 1 V a � v "�'l�,,...,.,, za Figure 1. Corner reinforcement does not rovide minimum P Figure 2. Post installed corner reinforcement needs required lap splice of 24 inches. Additionally, vertical reinforcement at corners and throughout shall extend full to be tied to maintain position during grouting. height of wall. I `h` ENGINEERING SINCE 1995 GTPP / r - iii ,.., :::::::::1: itI f r "� [� te _k 5s i7 a � • g_ .mot _ '�Ei I 1 .s Figure 3. 12-inch reinforcement lap splice provided Figure 4. Cleanout windows not provided for high is less than the minimum requirement of 24 lift grouting operation. inches.