Loading...
HomeMy WebLinkAboutAs-Built/ Hers rating OCT 2 8 2025 /LOCUS DATA j / I 28 1 CURRENT OWNER JOANNE CURRAN SRO( LANE n /... N Q PLAN REFERENCE 173-3 ��F, /\ I [!T 2� 2 � DEED REFERENCE 30416-329 �� $YNT a ZONING DISTRICT R-25 JCS oo H AVE 08 off. 30.Y s' SIl4ER LEAF LANE FLOOD ZONE "X" G , ;',� ASSESSORS MAP 23 a40 26.7' �. P NOT SCALE: PARCEL 89 SETBACKS 30', 6', 6' te. ' i$� 25-0109 OVERLAY DISTRICT NONE I' �P \\• LOT AREA 10,300t S.F. 0 NEW ' 4 BEDROOM DWELUNG CERTIFIED PLOT PLAN DECK #8 •., GARAGE CRUISER LANE LET 22 18'2' 29.0' IN / y W. YARMOUTH, MASS it. JULY 12, 2025 ` lJ`#' o�Q6 SE083-2187 OLLOWNG STATEMENTS TO THE YARMOUTHIFY THE FBUILDING DEPARTMENT lb LOT 21 Fvu 4, \ I HEREBY CERTIFY THAT THE LOT SHOWN AND .4). •b OWNER/APPLICANT: THE BUILDING THEREON CONFORM TO 10,3001 S.F. yk° \ JOANNE CURRAN ZONING BY-LAW WIT REGARD TO DIMENSIONAL 8 CRUISER LANE REQUIREMENTS AND ANR PLAN AS RECORDED. I FURTHER CERTIFY THAT THE LOT SHOWN LOT 6A DOES NOT FALL WITHIN A SPECIAL FEDERAL 20 HARDING LANE FLOOD HAZARD AREA AND IS DESIGNATED AS W. "ARMOUTH, MA 02673 ZONE "X" ON FIRM #25001C0588 J, DATED 7/18/14 \ NOTE: THIS PROPERTY IS SUBJECT TO A CONSERVATION ORDER OF CONDITI!NS �.•• r,,ED:AAN 83-2187 THAT WAS EXTENDED UNOLPREPARED BY: 4/10/2025 WITH A FURTHER 2 Yt ARS UNTIL 4/10/27 AS A RESULT OF"'NE E SURVEY, INC. STONE m GOVERNOR'S TOLLING PERIOD. P.O. BOX 1729 No2°980 SANDWICH, MA 02563 � 0 20 30 4° CELL (508) 527-3600 \ GRAPHIC SCALE: EAS.SURVEY®YAHOO.COM FOWARD A. STONE RPLS #28980 1 INCH == 20 FEET Home Energy Rating Certificate Property HERS New Residence Rating Type: Confirmed Certified Energy Rater: Chris Picariello 8 Cruiser Ln. Rating Date: 2025-10-15 Rating Number: 335 Yarmouth, MA 02673 Registry ID: 809733909 r Estimated Annual Energy Cost Use MMBtu Cost Percent HERS Index: 50 Efficient Home Comparison: 50% Better Heating 27.9 $209 18% General Information Cooling 1.7 $75 6% Conditioned Area 2016 sq. ft. House Type Single-family detached Hot Water 11.7 $79 7% Conditioned Volume 15120 cubic ft. Foundation Unconditioned basement Lights/Appliances 18.6 $679 57% Bedrooms 4 Photovoltaics 0.0 $0 0% Service Charges $150 13% Total 60.0 $1192 100% Mechanical Systems Features Heating: Fuel-fired air distribution, Natural gas, 96.5 AFUE. r Cooling: Air conditioner, Electric, 14.5 SEER. L Criteria Water Heating: Instant water heater, Natural gas, 0.93 EF, 0.0 Gal. This home meets or exceeds the minimum criteria for the following: 2015 IECC Performance Path Duct Leakage to Outside 68.00 CFM25 Ventilation System Exhaust Only: 80 cfm, 20.6 watts. 2015 IECC HERS ERI Programmable Thermostat Heat=Yes; Cool=Yes 2015 IECC Energy Code w/ MA Stretch Code Amendments* I Building Shell Features Ceiling Flat R-51.0 Slab None Sealed Attic NA Exposed Floor R-30.0 Vaulted Ceiling NA Window Type U-Value: 0.280, SHGC: 0.380 *Compliance is determined by the rater. Above Grade Walls R-21.0 Infiltration Rate 692 CFM50 (2.75 ACH50) 1 Foundation Walls R-0.0 Method Blower door Chris Picariello Cape Cod HERS Raters Lights and Appliance Features PO Box 1010 Interior Fluor Lighting (%) 10.0 Range/Oven Fuel Natural gas South Yarmouth, MA 02664 Interior LED Lighting (%) 90.0 Clothes Dryer Fuel Electric (508)737-8011 Refrigerator (kWh/yr) 553 Clothes Dryer CEF 3.73 CapeCodHERSRaters.com Dishwasher (kWh/yr) 220 Ceiling Fan (cfm/Watt) 0.00 ' OCT 2 8 2025 Certified Energy Rater: eitOz a.4. REM/Rate 2023 - Residential Energy Analysis Tool This information does not constitute any warranty of energy costs or savings. © 1985-2024 NORESCO, Westminster, Colorado. The Home Energy Rating Standard Disclosure for this home is available from the rating provider. 2015 IECC Energy Cost Compliance Property Organization HERS New Residence Cape Cod HERS Raters Confirmed 8 Cruiser Ln. (508)737-8011 2025-10-15 Yarmouth, MA 02673 Chris Picariello Rating No:335 Rater ID:6397177 Weather:Barnstable AP, MA Builder 8 Crusier Ln Yarmouth Phil Curran 6397177.335.8CruiserLnYarmouth Annual Energy Cost $/yr 2015 IECC As Designed Heating 360 310 Cooling 137 139 Water Heating 160 159 SubTotal - Used to Determine Compliance 658 607 Mechanical Ventilation Fan 33 20 Lights a Appliances (minus MechVent) 754 665 Photovoltaics -0 -0 Service Charge 150 150 Total 1595 1442 Mandatory Requirements Annual Energy Cost Check PASSES Duct Insulation R-Value Check(per Section 405.2) PASSES Window U-Value and SHGC Check(per Section 402.5) PASSES Home Infiltration (Section 402.4.1) PASSES Duct Testing (Section 403.3.3) PASSES Mechanical Ventilation (Section 403.6) PASSES Mechanical Ventilation Fan Efficacy(Section 403.6.1) PASSES Mandatory Requirements Check Box (2015 IECC) PASSES This home MEETS the annual energy cost requirements of Section 405 of the 2015 International Energy Conservation Code based on a climate zone of 5A. In fact, this home surpasses the requirements by 7.6%. Name Chris Picariello Signature C../04 ,a4G%2,14 Organization Cape Cod HERS Raters Date 17 October 2025 In accordance with IECC, building inputs, such as setpoints, infiltration rates, and window shading may have been changed prior to calculating annual energy cost. Furthermore, the standard reference design HVAC system efficiencies are set equal to those in the design home as specified in the 2015 IECC. These standards are subject to change, and software updates should be obtained periodically to ensure the compliance calculations reflect current federal minimum standards. REM/Rate 2023 - Residential Energy Analysis Tool This information does not constitute any warranty of energy costs or savings. © 1985-2024 NORESCO, Westminster, Colorado. Air Leakage Property Organization HERS New Residence Cape Cod HERS Raters Confirmed 8 Cruiser Ln. (508)737-8011 2025-10-15 Yarmouth, MA 02673 Chris Picariello Rating No:335 Rater ID:6397177 Weather:Barnstable AP, MA Builder 8 Crusier Ln Yarmouth Phil Curran 6397177.335.8CruiserLnYarmouth 17.blg.MEB.bIg Blower Door Test Heating Cooling Natural ACH 0.20 I 0.17 Whole ACH® 50 Pascals 2.751 2.75 CFM®25 Pascals 4411 441 House CFM @ 50 Pascals 692 I 692 Infiltration Eff. Leakage Area(sq.in) 38.0 38.0 Specific Leakage Area 0.00013 0.00013 ELA/100 sf shell (sq.in) 0.78 0.78 CFM50/sf shell 0.14 0.14 Leakage to Outside options duct --CFM @ 25 Pascals 68 --CFM25 / CFMfan 0.0402 Duct --CFM25 / CFA 0.03371 Leakage --CFM® 50 Pascals N/A I --Eff. Leakage Area (sq.in) N/A --Thermal Efficiency N/A Total Duct Leakage Units: CFM25/CFA --Total Duct Leakage 0.05361 Mechanical Sys Type Exhaust Only i ASHRAE ASHRAE Adj. Sensible Recovery Eff. (%) 0.0 62.2-2010 62.2-2013 Adj. Total Recovery Eff. (%) 0.0 Ventilation Outdoor Air Rate (cfm) 60 58 70 ---(Balanced OA cfm) 0 ---(Unbalanced OA cfm) 601 ---(MF Recirculated cfm) 0 Hours/Day 24.0 i 24.0 24.0 Ave Fan Watts 15.5 Cooling Ventilation Natural Ventilation'I ASHRAE 62.2 - Ventilation Requirements The ASHRAE 62.2 flow rates shown above are the CONTINUOUS mechanical Outdoor Air ventilation which will meet the whole-home requirement under that version of the standard. The 62.2-2013 rate incorporates any appropriate'infiltration credit'. Intermittent mechanical ventilation may be used if the flow rate is adjusted accordingly, as long as the system provides ventilation at least once every 3 hours. For more detail, refer to the appropriate standard. REM/Rate 2023 - Residential Energy Analysis Tool This information does not constitute any warranty of energy costs or savings. ©1985-2024 NORESCO, Westminster, Colorado.