Loading...
HomeMy WebLinkAbout703 Rte 28 COMPLETE DRC PACKET 011326From:Williams, Kathleen To:Dick Martin (dick@capecodera.com); Peter Malpass; Peter Slovak (pslovak@verizon.net); Sara J Porter (sjparch@comcast.net) Subject:DRC Meeting - 1/13/26 - 703 Route 28 Date:Friday, January 9, 2026 4:15:00 PM Attachments:011326 DRC Agenda and Materials RED.pdf Hi Guys, Please find attached the DRC Meeting Agenda and materials for the Tuesday January 13th meeting at 4:00 PM in Conference Room B (lower level of Town Hall). The full application is also available online at: https://www.yarmouth.ma.us/AgendaCenter/ViewFile/Agenda/_01132026-4691 703 Route 28: The Applicant proposes to redevelop the property by razing the existing structure and replacing with six (6) dwelling units in three (3) duplexes, along with various site improvements including access drive, drainage, and new utility services with municipal sewer connection. Access remains off Route 28 with the elimination of one of the curb cuts. A locked, paved connection to Mermaid Lane is provided for emergency use only. Two parking spaces per unit will be provided in garages under the buildings. The property is located within a floodplain and other wetland resource areas. The site will be redeveloped utilizing Zoning Bylaw Section 414 – Village Centers Overlay District (VCOD) VC1. Architecture: I really like the architecture, has a boat house/cottage feel to it. They include a nice Route 28 façade with front door entrance, like the variations in the roof and the enhanced roof overhang with brackets. The middle building does not appear to have any variations in the wall heights and the length of the interior wall facades are 54’ exceeding the 50’ without a modulation. They should provide some additional information on the building mounted lighting (there is not site lighting). Site Work: The buffer landscaping is light, although they are doing a comprehensive planting plan around the Parkers River. They are proposing a 6’ white vinyl fence along the eastern property line. A nice cedar board fence would be preferrable. Transformer should be located to the east of the driveway and not right in front of the building, and should be screened Hard copies are here at the Community Development window. Thanks, Kathy ---------------------------------------- Kathy Williams, P.E. Yarmouth Town Planner 1146 Route 28 South Yarmouth, MA 02664-4492 (508) 398-2231 Ext 1276 kwilliams@yarmouth.ma.us   Engineers Environmental Scientists Software Developers Landscape Architects Planners Surveyors 349 Main Street, Route 28, Unit D / West Yarmouth, MA 02673 / 508-778-8919 DECEMBER 23, 2025 www.bscgroup.com Town of Yarmouth Department of Community Development 1146 Route 28 South Yarmouth, MA 02664 RE: 703 Route 28, The Residences at Parkers River, VCOD Site Plan Review Application To Whom It May Concern, BSC Group, Inc. (BSC) is pleased to present the following application package for a multi-family residential development at 703 Route 28, on behalf of the Applicant, Steven M. Katz. This application is submitted pursuant to Section 414 of the Town of Yarmouth Zoning Bylaws, for VCOD development. The following summary has been prepared to assist the Town in its review of the proposed development, as outlined in the Operational Regulations of the Yarmouth Planning Board. Existing Site The site was previously developed as a commercial property and contains an existing one-story building, which was last operated as a furniture store and repair shop. The parcel is 35,248± square feet and is located in the B2 Zoning District and the VC1, ROAD, and GIZ Overlay Districts. The site has two (2) existing curb cuts along Route 28 and a paved parking lot. The site is located in a FEMA Zone AE but the existing building does not comply with FEMA regulations. The existing building, parking lot and the on-site sewage disposal system, all encroach on the buffer zones associated with the wetland resource areas that are associated with Parkers River. The building is currently served by an on-site sewage disposal system with a design flow of 1,800 gallons per day. The leaching facility associated with this system does not comply with Title 5, primarily because of its location, which is about 35 feet away from a wetland resource area. The existing building is served by overhead electric and telecommunications services, natural gas, and domestic water. Proposed Development The Applicant is proposing to redevelop this property by replacing the existing commercial building with three (3) duplexes, providing a total of six (6) residential units. Prior to construction of any new facilities, erosion and sedimentation controls will be established and the existing commercial building and shed will be demolished. The proposed redevelopment of the site will result in a decrease in impervious area of approximately 7,645 square feet. Site Access The site is located on Route 28, which is a State Highway. Therefore, an Access Permit is required by MassDOT prior to construction. The westerly curb cut will be closed permanently, and the easterly curb cut will be reconfigured to comply with both MassDOT and local requirements. 349 Main Street, Route 28, Unit D / West Yarmouth, MA 02673 / 508-778-8919 The southeastern corner of the locus shares a common boundary with Mermaid Lane for approximately 16 feet. A physical connection of the site’s driveway to the adjacent roadway (Mermaid Lane) is proposed as part of this project, for the sole purpose of emergency access and will include a gate, which will be secured by Knox Box. Each unit will have its own garage, which will include sufficient area for two (2) parking spaces. Stormwater Management Stormwater management facilities have been designed in accordance with the Massachusetts Stormwater Handbook and the Town of Yarmouth Stormwater Management Regulations. Water quality catch basin units located on the eastern side of the driveway will collect stormwater runoff from the drive and surrounding areas and pre-treat stormwater prior to conveyance for recharge to the groundwater. A large subsurface infiltration system will be constructed beneath the driveway. The system is comprised of 90-Cultec C-100HD leaching chambers in a bed of crushed stone and has been designed to manage stormwater from design storms up to and including the 100-year storm. Each of the three (3) water quality catch basin units on-site will discharge pre-treated stormwater to this system. Utility Services The other utility services required to support this project include domestic water, electric, telecommunications and natural gas. The existing water service will need to be upgraded to a 2-inch service and reconfigured to serve the new buildings. The new buildings will each require new natural gas, electric and telecommunications services. Wastewater Management As noted above, the site was previously served by an on-site sewage disposal system. This system will be abandoned-in-place and a 6-inch connection to the new municipal sewer system will be established prior to occupancy. We look forward to presenting this project to the Town. In the interim, please feel free to contact us, should you have any questions or concerns. Sincerely, BSC Group, Inc. Brian G. Yergatian, PE, LEED AP Manager of Civil Engineering, Senior Associate Steven M. Katz 99 Sullivan Road, West Yarmouth, MA 02673 November 19, 2025 (508) 360-3851 skatz@lathamcenters.org 703 Route 28, South Yarmouth Map 32, Parcel 120 B2 (VC1 Overlay District) AE-11, AE-12 BSC Group, Inc. ERT Architects, Inc. The Applicant is proposing the redevelopment of an existing commercial property in accordance with the provisions of the Village Center Overlay District (VC1), as multi-family housing with a total of six (6) units, which will be located within three duplex housing units. Access to the property is from Route 28. The existing curb cut will be reconfigured and realigned. The proposed buildings will be constructed on pilings and raised above the Flood Zone, in accordance with FEMA regulations. Each unit will have one (1) parking space located under the building. A paved connection to Mermaid Lane at the southern end of the site will be provided for emergency use only and controlled by a locked gate with Knox Box. The project will also require new utility services (including connection to the municipal sewer), stormwater management and landscaping. The project also requires an Order of Conditions from the Yarmouth Conservation Commission. 11/19/2025For Steven Katz 299 White’s Path South Yarmouth, MA 02664 508.362.8883 WWW.ERTArchitects.com Town of Yarmouth Design Review Application Materials Specification Sheet Date: December 09, 2025 Applicant: Steven M. Katz Project Location: 703 Route 28, South Yarmouth, MA Siding Type & Material: Mixture of white cedar shingles, vertical lap siding, and horizontal lap siding Colors: Mixture of earth tones; Lighthouse Grey, Savannah Wicker, Cypress, Buckskin, Natural Clay. See attached samples Roof Material: Architectural asphalt Pitches: 5:12 Color: Black Windows: Double hung, vinyl clad Color: White Doors: Wood &/or insulated fiberglass Color: Wood doors – Mahogany, fiberglass doors – white Trim Size: 1x4 @ doors and windows, 1x8 fascia, 36” soffits Color: White Shutters: NA Gutters: 6” half round Color: White Garage Doors: Insulated aluminum Color: White Decks & Railings: Azek decking w/ glass railing system Color: Coastline Grey Fencing: By others Retaining Walls: NA Signs: NA LOCUS 703 ROUTE 28 REDEVELOPMENT 703 ROUTE 28 SOUTH YARMOUTH, MASSACHUSETTS DECEMBER 19, 2025 G-1.0 TITLE SHEET V-1.0 EXISTING CONDITIONS PLAN C-1.0 SITE PREPERATION & DEMOLITION PLAN C-1.1 EROSION & SEDIMENTATION CONTROL PLAN C-2.0 LAYOUT & MATERIALS PLAN C-3.0 GRADING & DRAINAGE PLAN C-4.0 UTILITY PLAN L-1.0 LANDSCAPE PLAN C-5.0 - C-5.1 DETAILS STEVEN M. KATZ 99 SULLIVAN ROAD WEST YARMOUTH, MA 02673 LOCUS MAP ISSUED FOR PERMITTING NOT FOR CONSTRUCTION INDEX OF DRAWINGS 349 Main Street - Route 28 West Yarmouth, Massachusetts 02673 508 778 8919 12/19/2025 G G G G G G G G G G G O H W O H W O H W W OHW OHW OHW OHW OHW OHW O H W O H W (PUBL I C V A R I A B L E W I D T H ) MAIN S T R E E T - S T A T E R O U T E 2 8 P A R K E R S R I V E R PA R K E R S R I V E R S (PRIV A T E 4 0 ' W I D E ) MERM A I D L A N E NA D 8 3 M A M A I N L A N D X X X X X W W W W G G G G G G G G G IN PLAN OF LAND 703 ROUTE 28 SOUTH YARMOUTH MASSACHUSETTS (BARNSTABLE COUNTY) EXISTING CONDITIONS PLAN DECEMBER 19, 2025 LOCUS V-1.0 349 Main Street - Route 28 West Yarmouth, Massachusetts 02673 508 778 8919 G G G G G G G G G G G O H W O H W O H W W OHW OHW OHW OHW OHW OHW O H W O H W (PUBL I C V A R I A B L E W I D T H ) MAIN S T R E E T - S T A T E R O U T E 2 8 P A R K E R S R I V E R PA R K E R S R I V E R S (PRIV A T E 4 0 ' W I D E ) MERM A I D L A N E NA D 8 3 M A M A I N L A N D W W W W G G G G G G G G G SITE PREPARATION & DEMOLITION PLAN C-1.0 349 Main Street - Route 28 West Yarmouth, Massachusetts 02673 508 778 8919 IN ISSUED FOR PERMITTING NOT FOR CONSTRUCTION 703 ROUTE 28 REDEVELOPMENT SOUTH YARMOUTH MASSACHUSETTS (BARNSATBLE COUNTY) DECEMBER 19, 2025 12/19/2025 G G G G G G G G G G G O H W O H W O H W W OHW OHW OHW OHW OHW OHW O H W O H W (PUBL I C V A R I A B L E W I D T H ) MAIN S T R E E T - S T A T E R O U T E 2 8 P A R K E R S R I V E R PA R K E R S R I V E R S (PRIV A T E 4 0 ' W I D E ) MERM A I D L A N E NA D 8 3 M A M A I N L A N D W W W W G G G G G G G G G EROSION & SEDIMENTATION CONTROL PLAN C-1.1 349 Main Street - Route 28 West Yarmouth, Massachusetts 02673 508 778 8919 IN ISSUED FOR PERMITTING NOT FOR CONSTRUCTION 703 ROUTE 28 REDEVELOPMENT SOUTH YARMOUTH MASSACHUSETTS (BARNSATBLE COUNTY) DECEMBER 19, 2025 12/19/2025 (PUBL I C V A R I A B L E W I D T H ) MAIN S T R E E T - S T A T E R O U T E 2 8 P A R K E R S R I V E R PA R K E R S R I V E R (PRIV A T E 4 0 ' W I D E ) MERM A I D L A N E NA D 8 3 M A M A I N L A N D LAYOUT & MATERIALS PLAN C-2.0 349 Main Street - Route 28 West Yarmouth, Massachusetts 02673 508 778 8919 IN ISSUED FOR PERMITTING NOT FOR CONSTRUCTION 703 ROUTE 28 REDEVELOPMENT SOUTH YARMOUTH MASSACHUSETTS (BARNSATBLE COUNTY) DECEMBER 19, 2025 12/19/2025 G G G G G G G G G G G O H W O H W O H W W OHW OHW OHW OHW OHW OHW O H W O H W (PUBL I C V A R I A B L E W I D T H ) MAIN S T R E E T - S T A T E R O U T E 2 8 P A R K E R S R I V E R PA R K E R S R I V E R S (PRIV A T E 4 0 ' W I D E ) MERM A I D L A N E NA D 8 3 M A M A I N L A N D W W W W G G G G G G G G G GRADING & DRAINAGE PLAN C-3.0 349 Main Street - Route 28 West Yarmouth, Massachusetts 02673 508 778 8919 IN ISSUED FOR PERMITTING NOT FOR CONSTRUCTION 703 ROUTE 28 REDEVELOPMENT SOUTH YARMOUTH MASSACHUSETTS (BARNSATBLE COUNTY) DECEMBER 19, 2025 12/19/2025 G G G G G G G G G G G O H W O H W O H W W OHW OHW OHW OHW OHW OHW O H W O H W (PUBL I C V A R I A B L E W I D T H ) MAIN S T R E E T - S T A T E R O U T E 2 8 P A R K E R S R I V E R PA R K E R S R I V E R S (PRIV A T E 4 0 ' W I D E ) MERM A I D L A N E NA D 8 3 M A M A I N L A N D W W W W G G G G G G G G G S S S S W W W W W W W W W W W W W W W W W W S S S S S S S S S W W W W W W W W W W UTILITY PLAN C-4.0 349 Main Street - Route 28 West Yarmouth, Massachusetts 02673 508 778 8919 IN ISSUED FOR PERMITTING NOT FOR CONSTRUCTION 703 ROUTE 28 REDEVELOPMENT SOUTH YARMOUTH MASSACHUSETTS (BARNSATBLE COUNTY) DECEMBER 19, 2025 12/19/2025 (PUBL I C V A R I A B L E W I D T H ) MAIN S T R E E T - S T A T E R O U T E 2 8 P A R K E R S R I V E R PA R K E R S R I V E R (PRIV A T E 4 0 ' W I D E ) MERM A I D L A N E (36) - Va(6) - Rv (5) - Cp (4) - Cp (7) - Cp (6) - Cp (6) - Cp (4) - Au (7) - Au (18) - Va (3) - Au (2) - Au (14) - Rv (12) - Va (10) - Au (12) - Rv (18) - Va (10) - Va (19) - Va (10) - Rv (2) - AA NA D 8 3 M A M A I N L A N D CODE QTY BOTANICAL NAME COMMON NAME CONT CAL SHADE TREES AA 3 ACER RUBRUM 'AUTUMN FLAME'AUTUMN FLAME RED MAPLE B & B 3-3.5" CAL CODE QTY BOTANICAL NAME COMMON NAME CONT HT. SHRUBS Au 30 ARCTOSTAPHYLOS UVA-URSI KINNIKINNICK 3 GAL Cp 33 COMPTONIA PEREGRINA SWEET FERN 3 GAL Rv 45 ROSA VIRGINIANA VIRGINIA ROSE 3 GAL Va 126 VACCINIUM ANGUSTIFOLIUM LOWBUSH BLUEBERRY 3 GAL PLANT SCHEDULE 42 113 28 26 2 LANDSCAPE PLAN L-1.0 349 Main Street - Route 28 West Yarmouth, Massachusetts 02673 508 778 8919 IN ISSUED FOR PERMITTING NOT FOR CONSTRUCTION 703 ROUTE 28 REDEVELOPMENT SOUTH YARMOUTH MASSACHUSETTS (BARNSATBLE COUNTY) DECEMBER 19, 2025 12/19/2025 DETAILS C-5.0 349 Main Street - Route 28 West Yarmouth, Massachusetts 02673 508 778 8919 IN ISSUED FOR PERMITTING NOT FOR CONSTRUCTION 703 ROUTE 28 REDEVELOPMENT SOUTH YARMOUTH MASSACHUSETTS (BARNSATBLE COUNTY) DECEMBER 19, 2025 12/19/2025 DETAILS C-5.1 349 Main Street - Route 28 West Yarmouth, Massachusetts 02673 508 778 8919 IN ISSUED FOR PERMITTING NOT FOR CONSTRUCTION 703 ROUTE 28 REDEVELOPMENT SOUTH YARMOUTH MASSACHUSETTS (BARNSATBLE COUNTY) DECEMBER 19, 2025 FIGURE 1 ZOOM OF SIDE PORTAL SHOWING MAX. PIPE O.D. MAX. PIPE: 6" [150mm] HDPE 6" [150mm] PVC CULTEC CONTACTOR 100HD HEAVY DUTY TYPICAL INTERLOCK MODEL 100RHD MODEL 100EHD MODEL 100EHD CULTEC HVLV SFCx2 FEED CONNECTOR TRIM PORTAL TO UTILIZE INTERNAL MANIFOLD FEATURE HIDDEN END MODEL 100EHD MODEL 100RHD (SINGLE CHAMBER INSTALLATION) CULTEC UNIVERSAL INSPECTION PORT KIT DETAIL FINAL ASSEMBLY CULTEC 12" [300mm] DUCTILE IRON SQUARE BASIN COVER [PART #1299CGC - SOLID] [PART #1299CGS - SLOTTED] CULTEC 12" [300mm] PVC UNIVERSAL INLINE DRAIN BODY [PART #2712AGSB] SDR-35 RISER PIPE CUT TO LENGTH BASED ON SYSTEM DEPTH. PIPE SHALL BE INSERTED INTO SDR-35 BELL END. SDR-35 RISER PIPE MAY BE 6" [150 mm], 8" [200 mm] OR 10" [250 mm] DIAMETER [PART NOT PROVIDED BY CULTEC] SDR-35 BELL END INSERTED 6" [150mm] INTO CHAMBER [PART NOT PROVIDED BY CULTEC] DUCTILE IRON N Y L O P L A S T DO NOT POLLUTE DRAINS TO WATERWAYS CULTEC CHAMBER SOLID COVER OPTION SLOTTED COVER OPTION NYLOPLAST DO NOT POLLUTE DRAINS TO WATERWAYS DUCTILE IRON 13.6" [346 mm] 13.6" [346 mm] HINGE FOR EASY ACCESS DUCTILE IRON FRAME SOLID DUCTILE IRON COVER SLOTTED DUCTILE IRON COVER. TOTAL OPEN AREA = 60.62 IN2 [645.16mm] PVC BODY PLAN VIEW PVC BODY ELEVATION VIEW HINGE FOR EASY ACCESS DUCTILE IRON FRAME 12.5" [317 mm] 11.0" [279 mm] 3.2" [81 mm] 11.0" [279 mm] STANDARD OPENING FOR 6" [150 mm] SDR-35 RISER PIPE PVC BODY CAN BE TRIMMED IN FIELD TO ACCOMMODATE 8" [200 mm] AND 10" [250 mm] SDR-35 RISER PIPE SIZES CULTEC CONTACTOR 100HD HEAVY DUTY END DETAIL INFORMATION SMALL RIB END DETAILEND DETAIL LARGE RIB MODEL 100RHD IS A STARTER/STAND ALONE UNIT. THEY ARE USED TO START ROWS OR CAN BE USED SINGULARLY. MODEL 100EHD IS A MIDDLE/END UNIT. THEY ARE USED TO CONTINUE ROWS AND ALSO USED TO END A ROW. CULTEC CONTACTOR 100HD HEAVY DUTY THREE VIEW MODEL 100RHD STARTER MODEL 100EHD MIDDLE/END LARGE RIB LARGE RIB SMALL RIB SMALL RIB 6.0" [152mm] SMALL RIB LARGE RIB CULTEC CONTACTOR 100HD CHAMBER STORAGE = 1.866 CF/FT [0.173 m3/m] INSTALLED LENGTH ADJUSTMENT = 0.5' [0.15m] 36.0" [916mm] 12.5" [318mm] INSTALLED LENGTH = 90.0" [2286mm] 96.0" [2438mm] 45.0" [1156mm]45.0" [1144mm] 6.0" [150mm] DIA. CULTEC INSPECTION PORT KNOCK-OUT OPTIONAL 4.5" [114mm] DIA. KNOCK-OUT SIDE PORTAL FOR OPTIONAL INTERNAL MANIFOLD (ACCOMMODATES CULTEC HVLV SFCx2 FEED CONNECTOR OR STORM PIPE) MAX. PIPE: 6" [150mm] HDPE 6" [150mm] PVC OPTIONAL CULTEC INSPECTION PORT - ZOOM DETAIL SDR-35 PIPE. BELL END CUT AND INSERTED 6.0" [150mm] INTO CHAMBER 6" [150mm], 8" [200mm], OR 10" [250mm] SDR-35 RISER (LENGTH VARIES BASED ON SYSTEM DEPTH) 12" PVC UNIVERSAL INLINE DRAIN BODY CAN BE TRIMMED TO ACCOMMODATE 6" [150mm], 8" [200mm] AND 10" [250mm] SDR-35 PVC PIPE AASHTO HS-20 RATED DUCTILE IRON FRAME AND COVER COMPACTED GRANULAR BACKFILL. THE BACKFILL MATERIAL SHALL MEET THE REQUIREMENTS OF CLASS I, II, OR III MATERIALS AS DEFINED BY ASTM D2321 HOLE TO BE CUT w/ HOLE SAW CENTERED ON CORRUGATION CREST. 6.25" [160mm], 8.50" [220mm], OR 10.75" [275mm] CONCRETE COLLAR/ASPHALT OVERLAY NOT REQUIRED FOR NON-TRAFFIC APPLICATIONS FIELD PLACED CLASS "C" CONCRETE COLLAR. CONCRETE COLLAR CAN RECEIVE ASPHALT OVERLAY IF DESIRED CULTEC 12" PVC UNIVERSAL INLINE DRAIN BODY CULTEC HVLV SFCx2 FEED CONNECTOR THREE VIEW 7.6" [194mm] 12.0" [305mm] 19.7" [500mm] GENERAL NOTES CULTEC CONTACTOR® 100HD CHAMBER PRODUCT SPECIFICATIONS GENERAL CULTEC CONTACTOR 100HD CHAMBERS ARE DESIGNED FOR UNDERGROUND STORMWATER MANAGEMENT. THE CHAMBERS MAY BE USED FOR RETENTION, RECHARGING, DETENTION OR CONTROLLING THE FLOW OF ON-SITE STORMWATER RUNOFF. CHAMBER PARAMETERS 1.THE CHAMBERS SHALL BE MANUFACTURED BY CULTEC, OF BROOKFIELD, CT. (203-775-4416 OR 1-800-428-5832) 2.THE CHAMBERS SHALL BE DESIGNED AND TESTED VIA FINITE ELEMENT ANALYSIS IN ACCORDANCE WITH THE ASTM F2787 "STANDARD PRACTICE FOR STRUCTURAL DESIGN OF THERMOPLASTIC CORRUGATED WALL STORMWATER COLLECTION CHAMBERS". THE LOAD CONFIGURATION SHALL INCLUDE: a. INSTANTANEOUS AASHTO DESIGN TRUCK LIVE LOAD AT MINIMUM COVER. b. MAXIMUM PERMANENT (50-YEAR) COVER LOAD. c.1-WEEK PARKED AASHTO DESIGN TRUCK LOAD. 3.THE INSTALLED CHAMBER SYSTEM SHALL PROVIDE RESISTANCE TO THE LOADS AND LOAD FACTORS AS DEFINED IN THE AASHTO LRFD BRIDGE DESIGN SPECIFICATIONS SECTION 12.12, WHEN INSTALLED ACCORDING TO CULTEC'S RECOMMENDED INSTALLATION INSTRUCTIONS. THE STRUCTURAL DESIGN OF THE CHAMBERS SHALL INCLUDE THE FOLLOWING: a. THE MINIMUM SAFETY FACTOR FOR LIVE LOADS SHALL BE 1.75 b. THE MINIMUM SAFETY FACTOR FOR DEAD LOADS SHALL BE 1.95. 4.THE CHAMBER SHALL BE VACUUM THERMOFORMED OF HIGH MOLECULAR WEIGHT HIGH DENSITY POLYETHYLENE (HMWHDPE) WITH A BLACK INTERIOR AND BLUE EXTERIOR. 5.THE CHAMBER SHALL BE ARCHED IN SHAPE. 6.THE CHAMBER SHALL BE OPEN-BOTTOMED. 7.THE CHAMBER SHALL BE JOINED USING AN INTERLOCKING OVERLAPPING RIB METHOD. CONNECTIONS MUST BE FULLY SHOULDERED OVERLAPPING RIBS, HAVING NO SEPARATE COUPLINGS OR SEPARATE END WALLS. 8.THE NOMINAL CHAMBER DIMENSIONS OF THE CULTEC CONTACTOR 100HD SHALL BE 12.5 INCHES (318 mm) TALL, 36 INCHES (914 mm) WIDE AND 8 FEET (2.44 m) LONG. THE INSTALLED LENGTH OF A JOINED CONTACTOR 100HD SHALL BE 7.5 FEET (2.29 m). 9.MAXIMUM INLET OPENING ON THE CHAMBER ENDWALL IS 10 INCHES (250 mm). 10.THE CHAMBER SHALL HAVE TWO SIDE PORTALS TO ACCEPT CULTEC HVLV® SFCX2 FEED CONNECTORS TO CREATE AN INTERNAL MANIFOLD. THE NOMINAL INSIDE DIMENSIONS OF EACH SIDE PORTAL SHALL BE 5.75 INCHES (146 mm) HIGH BY 7.5 INCHES (191 mm) WIDE. MAXIMUM ALLOWABLE OUTER DIAMETER (O.D.) PIPE SIZE IN THE SIDE PORTAL IS 6.9 INCHES (175 mm). 11.THE NOMINAL CHAMBER DIMENSIONS OF THE CULTEC HVLV SFCX2 FEED CONNECTOR SHALL BE 7.6 INCHES (194 mm) TALL, 12 INCHES (305 mm) WIDE AND 19.7 INCHES (500 mm) LONG. 12.THE NOMINAL STORAGE VOLUME OF THE CONTACTOR 100HD CHAMBER SHALL BE 1.866 FT³ / FT (0.173 m³ / m) - WITHOUT STONE. THE NOMINAL STORAGE VOLUME OF A JOINED CONTACTOR 100HD SHALL BE 13.995 FT³ / UNIT (0.396 m³ / UNIT) - WITHOUT STONE. 13.THE NOMINAL STORAGE VOLUME OF THE HVLV SFCX2 FEED CONNECTOR SHALL BE 0.294 FT³ / FT (0.027 m³ / m) - WITHOUT STONE. 14.THE CONTACTOR 100HD CHAMBER SHALL HAVE TWENTY-FOUR DISCHARGE HOLES BORED INTO THE SIDEWALLS OF THE UNIT'S CORE TO PROMOTE LATERAL CONVEYANCE OF WATER. 15.THE CONTACTOR 100HD CHAMBER SHALL HAVE 16 CORRUGATIONS. 16.THE ENDWALL OF THE CHAMBER, WHEN PRESENT, SHALL BE AN INTEGRAL PART OF THE CONTINUOUSLY FORMED UNIT. SEPARATE END PLATES CANNOT BE USED WITH THIS UNIT. 17.THE CONTACTOR 100RHD STARTER UNIT MUST BE FORMED AS A WHOLE CHAMBER HAVING TWO FULLY FORMED INTEGRAL ENDWALLS AND HAVING NO SEPARATE END PLATES OR SEPARATE END WALLS. 18.THE CONTACTOR 100EHD MIDDLE/END UNIT MUST BE FORMED AS A WHOLE CHAMBER HAVING ONE FULLY FORMED INTEGRAL ENDWALL AND ONE FULLY OPEN END WALL AND HAVING NO SEPARATE END PLATES OR END WALLS. 19.THE HVLV SFCX2 FEED CONNECTOR MUST BE FORMED AS A WHOLE CHAMBER HAVING TWO OPEN END WALLS AND HAVING NO SEPARATE END PLATES OR SEPARATE END WALLS. THE UNIT SHALL FIT INTO THE SIDE PORTALS OF THE CONTACTOR 100HD AND ACT AS CROSS FEED CONNECTIONS. 20.CHAMBERS MUST HAVE HORIZONTAL STIFFENING FLEX REDUCTION STEPS BETWEEN THE RIBS. 21.THE CHAMBER SHALL HAVE A RAISED INTEGRAL CAP AT THE TOP OF THE ARCH IN THE CENTER OF EACH UNIT TO BE USED AS AN OPTIONAL INSPECTION PORT OR CLEAN-OUT. 22.THE UNITS MAY BE TRIMMED TO CUSTOM LENGTHS BY CUTTING BACK TO ANY CORRUGATION. 23.THE CHAMBER SHALL BE MANUFACTURED IN AN ISO 9001:2015 CERTIFIED FACILITY. 24.MAXIMUM ALLOWED COVER ON TOP OF UNIT SHALL BE 10.0 FEET [3.04 m] 25.THE INSTALLED CHAMBER SYSTEM SHALL BE STRUCTURALLY DESIGNED TO PROVIDE RESISTANCE TO LIVE LOADS AS DEFINED BY THE AASHTO H-20/HL-93 SPECIFICATION WHEN INSTALLED ACCORDING TO CULTEC'S RECOMMENDED INSTALLATION INSTRUCTIONS. CULTEC HVLV® SFCx2 FEED CONNECTOR GENERAL CULTEC HVLV SFCx2 FEED CONNECTORS ARE DESIGNED TO CREATE AN INTERNAL MANIFOLD FOR CULTEC CONTACTOR 100HD STORMWATER CHAMBERS. CHAMBER PARAMETERS 1.THE CHAMBERS SHALL BE MANUFACTURED BY CULTEC, OF BROOKFIELD, CT. (203-775-4416 OR 1-800-428-5832) 2.THE CHAMBER SHALL BE VACUUM THERMOFORMED OF HIGH MOLECULAR WEIGHT HIGH DENSITY POLYETHYLENE (HMWHDPE) WITH A BLACK INTERIOR AND BLUE EXTERIOR. 3.THE CHAMBER SHALL BE ARCHED IN SHAPE. 4.THE CHAMBER SHALL BE OPEN-BOTTOMED. 5.THE NOMINAL CHAMBER DIMENSIONS OF THE CULTEC HVLV SFCX2 FEED CONNECTOR SHALL BE 7.6 INCHES (194 mm) TALL, 12 INCHES (305 mm) WIDE AND 19.7 INCHES (500 mm) LONG. 6.THE NOMINAL STORAGE VOLUME OF THE HVLV SFCX2 FEED CONNECTOR SHALL BE 0.294 FT3 / FT (0.027 m3 / m) - WITHOUT STONE. 7.THE HVLV SFCX2 FEED CONNECTOR CHAMBER SHALL HAVE 3 CORRUGATIONS. 8.THE HVLV SFCX2 FEED CONNECTOR MUST BE FORMED AS A WHOLE CHAMBER HAVING TWO OPEN END WALLS AND HAVING NO SEPARATE END PLATES OR SEPARATE END WALLS. THE UNIT SHALL FIT INTO THE SIDE PORTALS OF THE CONTACTOR 100HD STORMWATER CHAMBER AND ACT AS CROSS FEED CONNECTIONS CREATING AN INTERNAL MANIFOLD. 9.THE CHAMBER SHALL BE DESIGNED TO WITHSTAND TRAFFIC LOADS WHEN INSTALLED ACCORDING TO CULTEC'S RECOMMENDED INSTALLATION INSTRUCTIONS. 10.THE CHAMBER SHALL BE MANUFACTURED IN AN ISO 9001:2008 CERTIFIED FACILITY. ADS PLUS-US WOVEN GEOTEXTILE ADS PLUS-US WOVEN GEOTEXTILE IS DESIGNED AS A UNDERLAYMENT TO PREVENT SCOURING CAUSED BY WATER MOVEMENT WITHIN THE CULTEC CHAMBERS AND FEED CONNECTORS UTILIZING THE CULTEC MANIFOLD FEATURE. IT MAY ALSO BE USED AS A COMPONENT OF THE CULTEC SEPARATOR ROW/ADS ISOLATOR ROW PLUS TO ACT AS A BARRIER TO PREVENT SOIL/CONTAMINANT INTRUSION INTO THE STONE WHILE ALLOWING FOR MAINTENANCE. GEOTEXTILE PARAMETERS 1.THE GEOTEXTILE SHALL BE PROVIDED BY CULTEC OF BROOKFIELD, CT. (203-775-4416 OR 1-800-428-5832) 2.THE GEOTEXTILE SHALL BE BLACK AND WHITE IN APPEARANCE. 3.THE GEOTEXTILE SHALL HAVE A MARV WEIGHT OF 8.0 OZ/YD2 PER ASTM D5261 TESTING METHOD. 4.THE GEOTEXTILE SHALL HAVE A GRAB TENSILE STRENGTH OF 325 X 325 LBS (1,445 X 1,445 N) PER ASTM D4632 TESTING METHOD. 5.THE GEOTEXTILE SHALL HAVE A ELONGATION @ BREAK RESISTANCE OF 15 X 15% PER ASTM D4632 TESTING METHOD. 6.THE GEOTEXTILE SHALL HAVE A CBR PUNCTURE RESISTANCE OF 1,124 LBS (5,000 N) PER ASTM D6241 TESTING METHOD. 7.THE GEOTEXTILE SHALL HAVE A TRAPEZOIDAL TEAR RESISTANCE OF 125 X 125 LBS (556 X 556 N) PER ASTM D4533 TESTING METHOD. CULTEC NO. 410™ NON-WOVEN GEOTEXTILE CULTEC NO. 410™ NON-WOVEN GEOTEXTILE MAY BE USED WITH CULTEC CONTACTOR® AND CONTACTOR® STORMWATER INSTALLATIONS TO PROVIDE A BARRIER THAT PREVENTS SOIL INTRUSION INTO THE STONE. GEOTEXTILE PARAMETERS 1.THE GEOTEXTILE SHALL BE PROVIDED BY CULTEC, OF BROOKFIELD, CT. (203-775-4416 OR 1-800-428-5832) 2.THE GEOTEXTILE SHALL BE BLACK IN APPEARANCE. 3.THE GEOTEXTILE SHALL HAVE A TYPICAL WEIGHT OF 4.5 OZ/SY (142 G/M). 4.THE GEOTEXTILE SHALL HAVE A TENSILE STRENGTH VALUE OF 120 LBS (533 N) PER ASTM D4632 TESTING METHOD. 5.THE GEOTEXTILE SHALL HAVE AN ELONGATION @ BREAK VALUE OF 50% PER ASTM D4632 TESTING METHOD. 6.THE GEOTEXTILE SHALL HAVE A MULLEN BURST VALUE OF 225 PSI (1551 KPA) PER ASTM D3786 TESTING METHOD. 7.THE GEOTEXTILE SHALL HAVE A PUNCTURE STRENGTH VALUE OF 65 LBS (289 N) PER ASTM D4833 TESTING METHOD. 8.THE GEOTEXTILE SHALL HAVE A CBR PUNCTURE VALUE OF 340 LBS (1513 N) PER ASTM D6241 TESTING METHOD. 9.THE GEOTEXTILE SHALL HAVE A TRAPEZOID TEAR VALUE OF 50 LBS (222 N) PER ASTM D4533 TESTING METHOD. 10.THE GEOTEXTILE SHALL HAVE A AOS VALUE OF 70 U.S. SIEVE (0.212 MM) PER ASTM D4751 TESTING METHOD. 11.THE GEOTEXTILE SHALL HAVE A PERMITTIVITY VALUE OF 1.7 SEC-1 PER ASTM D4491 TESTING METHOD. 12.THE GEOTEXTILE SHALL HAVE A WATER FLOW RATE VALUE OF 135 GAL/MIN/SF (5500 L/MIN/SM) PER ASTM D4491 TESTING METHOD. 13.THE GEOTEXTILE SHALL HAVE A UV STABILITY @ 500 HOURS VALUE OF 70% PER ASTM D4355 TESTING METHOD. CULTEC CONTACTOR 100HD CROSS SECTION 6.0" [152mm] MIN. 12.5" [318mm] 6.0" [152mm] MIN. 8.0" [203mm] MIN. FOR FLEXIBLE PAVEMENT 8.0" [203mm] MIN. FOR RIGID PAVEMENT 12.0" [305mm] MIN.36.0" [914mm] THE DESIGN ENGINEER IS RESPONSIBLE FOR ENSURING THAT THE REQUIRED BEARING CAPACITY OF SUB-GRADE SOILS HAVE BEEN MET FINISHED GRADE 3 4" - 2" [20-50mm] CLEAN, CRUSHED, ANGULAR STONE SURROUNDING CHAMBERS 10' [3.04m] MAX. COVER DEPTH 10.0" [203mm] MIN. FOR UNPAVED (REDUCE TO 6.0" [152mm] FOR NON-TRAFFIC APPLICATION) 40.0" [1016mm] MIN. CENTER TO CENTER GRANULAR WELL-GRADED SOIL/AGGREGATE MIXTURES, <35% FINES, COMPACT IN 6" (150 mm) MAX LIFTS TO 95% PROCTOR DENSITY CULTEC HVLV SFCx2 FEED CONNECTOR WHERE SPECIFIED WOVEN GEOTEXTILE TO BE PLACED BENEATH INTERNAL MANIFOLD FEATURE AND BENEATH ALL INLET/OUTLET PIPES (FOR SCOUR PROTECTION) NON-WOVEN GEOTEXTILE AROUND STONE. TOP AND SIDES MANDATORY, BOTTOM PER ENGINEER'S DESIGN PREFERENCE CULTEC SEPARATOR ROW - CULTEC INSPECTION PORT DETAIL (IF APPLICABLE) 24.0" [610mm] MIN. SUMP RECOMMENDED INLET STRUCTURE THE DESIGN ENGINEER IS RESPONSIBLE FOR ENSURING THAT THE REQUIRED BEARING CAPACITY OF SUB-GRADE SOILS HAS BEEN MET NON-WOVEN GEOTEXTILE AROUND STONE. TOP AND SIDES MANDATORY, BOTTOM PER ENGINEER'S DESIGN PREFERENCE 3 4" - 2" [20-50mm] CLEAN, CRUSHED, ANGULAR STONE SURROUNDING CHAMBERS SEPARATOR ROW/ADS ISOLATOR® ROW PLUS TO BE COVERED WITH NON-WOVEN GEOTEXTILE TRAFFIC RATED CULTEC INSPECTION PORT (SEE ZOOM DETAIL) CHAMBER CAN ACCOMMODATE 6" [150mm] SDR-35 OR SCH-40 PVC PAVEMENT OR FINISHED GRADE INLET/OUTLET PIPE PER ENGINEER DESIGN. PIPE TO BE INSERTED 12.0" [305mm] MIN. INTO CHAMBER MAXIMUM PIPE SIZE: 10" [250mm] HDPE 10" [250mm] PVC GRANULAR WELL-GRADED SOIL/AGGREGATE MIXTURES, <35% FINES, COMPACT IN 6" (150 mm) MAX LIFTS TO 95% PROCTOR DENSITY ELEVATED BYPASS PIPE 1 LAYER OF WOVEN GEOTEXTILE TO BE PLACED BENEATH ENTIRE SEPARATOR ROW/ADS ISOLATOR® ROW PLUS 12/19/2025