HomeMy WebLinkAboutNarrative 1.21.2026PROJECT NARRATIVE
#29 Lewis Bay Boulevard Unit 6, West Yarmouth
Proiect Narrative
The applicant respectfully submits this Notice of Intent application in support of
lifting and relocating an existing single-family dwelling located at 29 Lewis Bay
Boulevard, Unit 6. The property is located within a condominium association with an
exclusive use area consisting of 10,942 square feet located within a single-family
residential zoning district. The site is currently developed with a 5-bedroom single-
family dwelling, originally constructed in 1925 per the Town Assessor's records. A
Coastal Bank occupies the southern portion of the property, and the entire exclusive
use area falls within Land Subject to Coastal Storm Flowage, specifically within flood
zones AE (AE el. 11) and (VE el. 13) within the Limits of Moderate Wave Action.
All proposed work will take place outside of Flood Zone (VE el. 13). The property is
located along Nantucket Sound and is separated from the water by an existing Coastal
Beach and Coastal Bank. It should be noted that no work is proposed within any areas
mapped as Priority Habitat or Estimated Habitat for Endangered Species by the
Massachusetts Natural Heritage and Endangered Species Program (NHESP).
Proposed Work
The project proposes to lift the existing dwelling and relocate it to a position situated
farther from the Coastal Bank. Portions of the relocated structure will be located
within the 35-foot, 50-foot and 100-foot buffer zones to the Coastal Bank. The
primary objectives of this project are to increase the setback from the coastal bank by
relocating the dwelling from 12.6 feet to 29.0 feet, more than doubling the distance
from this resource area. Additionally, the project will reduce hardscape within the 0-
50 foot Buffer Zone, particularly within the most environmentally sensitive 0-35 foot
zone. The scope of proposed work includes the removal of unpermitted improvements
in accordance with the special conditions found in the Order of Conditions SE083-
2480, which was issued for the condominium association's stone revetment wall repair
project.
Roof drains and a relocated leaching catch basin are proposed to capture and infiltrate
stormwater runoff on -site, thereby reducing drainage impacts to the resource area
compared to existing conditions. All proposed work will take place within existing
lawn areas or previously developed portions of the site. A flood -resistant foundation
will be constructed in accordance with applicable FEMA requirements, representing a
substantial improvement over the existing non -compliant foundation. The new
foundation will achieve full compliance with flood zone requirements under the 1 Oth
Edition Massachusetts State Building Code for structures in Special Flood Hazard
Areas.
The condominium association maintains a shared 34-bedroom septic system serving
all existing units. The system consists of a dual compartment septic tank connected to
a Bio-microbics MicroFAST 4.5 Innovative Alternative component. Treated effluent
is gravity -fed into a pump chamber and subsequently distributed through a pressure -
dosed leaching field. The existing septic system successfully passed its most recent
Title 5 inspection conducted on May 23, 2018. No modifications to the existing septic
system are proposed, and the property will continue to utilize the shared septic
system. It is important to note that there is no proposed increase in the number of
bedrooms.
The project includes reconfiguration of the driveway, walkways, deck, and patio
areas. The proposed hardscape within the Buffer Zone will total 3,572 square feet,
with 572 square feet within the 0-35 foot buffer zone (a reduction of 508 square feet),
702 square feet within the 35-50 foot buffer zone (an increase of 24 square feet), and
2,298 square feet within the 50-100 foot buffer zone (an increase of 554 square feet).
According to the mitigation requirements established under Section 6.02 of the Town
of Yarmouth Wetland Protection Regulations, typical required mitigation for
hardscape within buffer zones ranges from 2:1 to 3:1. Applying these mitigation ratios
to the proposed changes, the project achieves a net reduction in required mitigation
area. Consequently, no additional mitigation is proposed or required for this project.
310 CMR 10.30 Coastal Banks
A Coastal Bank exists at the top of the existing revetment wall and was delineated in
accordance with DEP Policy 92-1. The top of the bank has experienced erosion due to
the deteriorated condition of the existing wall and storms in recent years. The bank
was armored years ago, therefore it does not serve as an active sediment source. The
condominium association recently filed a Notice of Intent for repairs to the existing
stone revetment wall, and Order of Conditions SE083-2480 was issued authorizing
the proposed work. The bank's ability to control floodwaters will not be altered by
any of the proposed work. No work is proposed on the bank as part of this project. A
silt fence work limit line will be provided off the top of the Coastal Bank to maintain
bank stability throughout construction. All erosion and sediment control measures
will be installed prior to the commencement of any site work and will be maintained
until all disturbed areas have been stabilized.
Land Subject to Coastal Storm Flowage
The property is located within Land Subject to Coastal Storm Flowage (AE el. 11)
and (VE el. 13) within the Limits of Moderate Wave Action per the FEMA National
Flood Hazard Layer. The proposed dwelling and all structures will be located outside
of Flood Zone (VE el. 13).
The proposed foundation design incorporates flood -resistant construction methods
and will achieve full compliance with flood zone requirements established under the
1 Oth Edition Massachusetts State Building Code for structures in Special Flood
Hazard Areas. No fill material is proposed, and existing grades will be substantially
maintained. All areas disturbed during construction activities will be restored with
loam and stabilized with appropriate seed mixtures upon completion of work. Based
on the proposed design, no adverse impacts to resource areas are anticipated during
coastal storm or flooding events. The elevated foundation will allow floodwaters to
pass beneath the structure, reducing obstruction to flood flows and minimizing
potential for structural damage.
Construction Protocol
All construction equipment will access work areas through the existing gravel
driveway. Prior to commencement of any site work, the surveyor will place work
limit stakes in accordance with the approved plans. The contractor will install and
maintain a silt fence, along the designated work limit line.
The construction sequence will proceed as follows: (1) installation of erosion
controls; (2) Demolition of the existing patio; (3) lifting and relocation of existing
dwelling with new foundation construction; (4) completion of dwelling additions and
structures construction; and (5) final site stabilization. Erosion and sediment control
measures will remain in place and be properly maintained until all disturbed areas
have been stabilized with loam and seed.