HomeMy WebLinkAboutFinal Inspection & Start-Up Check List 7/10/24 • 'f r 1 r1ai , ._� > 'MIr. r �a W W j ) :_ — r�ar i iiYl i Final Inspection & Start-Up Check List (Revised 03/30/09) Z.i n ea.+i ta...t P o1 'c S Customer: 1 Job/Kit#: 3 2'/f 1n Ground Date:6/1 6Stort up Date: � 0 Address: li e Y S I-A-4tw+'i Ave , • Ya.� a w kk IV./} • r Phone: Model: 611 ot.-OD IN Distributor Name .Z7*-e- S ASS + a a e- Dist.Contact MIX ail-0 Sco L feet.i n as1/Tout Checklist Item Comments SEPTIC TANK �ank is full of clean water L ❑ Outlet is equipped with effluent filter(not necessary if denite system) N/A • Nj/ Denite Only—Outl compartment has heavy media added Anc-t CLL6-44^ LNo visible evidence of settlement around tank ' CONTROL PANEL Panel is in an accessible location and properly mounted ©ater is installed if outdoors(cold weather climates only)and set to 40-50 F. []Pane is supplied with two power circuits of correct size Verify electrical connections with wiring diagram J-box in tank [ntrol panel terminal blocks (insure all connections are tight&wires are numbered) - Electrical conduit from panel to processor is sealed sure copy of electrical wiring diagram is stored in control panel Page 1 of 3 • -- IL Customer: L M W ear Job/Kft#: 321f9 , Date: 7/0/10 I y PROCESSOR TANK Tank is no deeper than 24-inches below final grade E 1 Risers are properly sealed i E Tank is free of debris(rocks,woodchips,dirt,etc) i [nit filled with water to bottom of support structure pipes } [Verify mechanical connections and check for leaks Inlet Pipe(4-inch PVC) ?= Discharge Pipe(2-inch PVC) ck Pipe(1-1/2-inch PVC) a9p-ba Denite Recycle(1-1/2-inch PVC) . Air inlet installed with positive pitch back to tank [Was system tested? (Exercise entire system in maintenance mode and note amperage readings) E Re-circulation Pump(s)Amp Draw: a ' y A-o-io ❑Pump Backs Pump(s)Amp Draw: a . 4 Nhii 1 ❑Discharge Pump(s)Amp Draw: ot.'6 Ate'^f _ • [ De-Nitrification Mix Pump(s)Amp Draw: .2. ' G " [r Are Discharge Pump(s)calibrated? 't-a c--1-o le Se (Note PSI Gauge Reading) • ❑ -Are Pump-back and Denite Pumps calibrated? -ory � (Note PSI Gauge ing) Is high float level correct? Is low float level correct? ❑ Is UV properly connected and bulb illuminated? // Is bag placement optimized? Insure PLC is in"run"mode or"terminal mode" (Terminal m only with telecommunications) ❑ Verify Telecommunication Connection(if applicable) iv Page 2 of 3 7 Customer: A44,4 Job/Kit#: 3.2119 Date: -///49/49-0/Li - i Are access covers at or slightly above finished grade and accessible year round? rjr--A---re access covers tight? Iomplete installation in accordance with the Contractor Installation Manual? IF l r h "Stop" ii r If installation is not in accordance with Installation Manual.Do not leave system on! I' Notify SentiTech.the owner and or the installing contractor of the issues! j Notes: gif/Tech .e. "4141445 Page 3 of 3