Loading...
HomeMy WebLinkAbout06_Beckers Package Store Permit Set 2026 2 24SHEET DESIGNED BY:WMLJR DRAWN BY:SEK/SD CHECKED BY:JAC DATE:NOV. 2024 PROJECT NO:19-19v REVISIONS: NO.DATE.DESCRIPTION 1 4/2025 DESIGN REVIEW 2 2/5/2026 PERMIT SET BE C K E R ' S P A C K A G E S T O R E 55 R O U T E 2 8 WE S T Y A R M O U T H , M A S S A C H U S E T T S AP 3 6 , LO T S 7 7 , 7 8 & 7 9 OF 8Q: \ 1 9 - 1 9 A h a r o n i a n & A s s o c i a t e s \ 1 9 - 1 9 v B e c k e r s P a c k a g e S t o r e \ A C A D \ B e c k e r ' s P a c k a g e S t o r e [ W o r k i n g P l a n ] - R 3 . d w g F e b . 2 4 , 2 0 2 6 1 1 : 4 5 a m PRELIMINARY, NOT FOR CONSTRUCTION JC E JC E JO E C A S A L I E N G I N E E R I N G , I n c . Ci v i l ∙ S i t e D e v e l o p m e n t ∙ T r a n s p o r t a t i o n Dr a i n a g e ∙ W e t l a n d s ∙ I S D S ∙ T r a f f i c ∙ F l o o d p l a i n 30 0 P o s t R o a d , W a r w i c k , R I 0 2 8 8 8  0       3 0 0  0       3  3 F A ; W W W . J O E C A S A L I . C O 0 COVER SHEET 1 SITE SITE IMPROVEMENT PLANS FOR BECKER'S PACKAGE STORE A PROPOSED MIXED-USE BUILDING CONSISTING OF ONE EXISTING COMMERCIAL UNIT & TWO NEW RESIDENTIAL UNITS 55 ROUTE 28 WEST YARMOUTH, MASSACHUSETTS AP 36, LOTS 77 - 79 ZONING DISTRICT: B2 BUSINESS ZONE & AQUIFER PROTECTION OVERLAY DISTRICT (APD) PROJECT TEAM INDEX OF DRAWINGS SHEET NO.PLAN 1 COVER SHEET 2 EXISTING CONDITIONS & SITE PREP. PLAN 3 SITE & LANDSCAPE PLAN 4 GRADING & DRAINAGE PLAN 5 UTILITY PLAN 6 CIVIL DETAILS I 7 CIVIL DETAILS II 8 CIVIL DETAILS III REFERENCE PLANS: SHEET 1 OF 1 SURVEY PLAN, PREPARED BY WATERMAN ENGINEERING OWNER:HUZAFIA CORPORATION 59 ANCHOR LANE COTUIT, MA 02635 ARCHITECT: AHARONIAN & ASSOCIATES, INC 310 GEORGE WASHINGTON HWY SMITHFIELD, RI 02917 PHONE: (401) 232-5010 CIVIL JOE CASALI ENGINEERING, INC. ENGINEER:300 POST ROAD WARWICK, RI 02888 PHONE: 401-944-1300 FAX: 401-944-1313 JOECASALI.COM LAND WATERMAN ENGINEERING CO. SURVEYOR:40 SUTTON AVENUE EAST PROVIDENCE, RI 02914 PHONE: 401-438-5775 STATE WIDE MAP WEST YARMOUTH, MA LOCUS MAP SCALE: 1' = 2,000'N SUBMISSIONS: PLANNING BOARD FOR SPECIAL PERMIT (USE) ZONING BOARD OF APPEALS (ZBA) SPECIAL PERMIT FOR NON-CONFORMING STRUCTURE WITH RELIEF APPROVALS: HISTORIC COMMISSION MEETING (JULY 30, 2025) DESIGN REVIEW COMMITTEE: FORMAL REVIEW (MAY 6, 2025) SITE PLAN REVIEW: FORMAL REVIEW (DECEMBER 3, 2024) RENDERING BY AHARONIAN & ASSOCIATES, INC. X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X EM WV GV S 01°19'37" W 155.73' N 01°18'20" E 511.62'140.00' 131.62' 240.00' N 7 8 ° 5 2 ' 0 5 " E 9 9 . 6 3 ' MAP 36, LOT 82.1 N/F KISHOR K. PATEL VOLUME 12505, PAGE 226 (COMMERCIAL USE; ZONE B2) N 7 8 ° 5 9 ' 3 3 " E 9 9 . 5 8 ' ( 1 0 0 ' ~ D E E D ) (100' ~ DEED) S 01°18'20" W 99.70' CONCRETE BOUND (FND ~ DESTROYED) CONCRETE BOUND (FND)CONCRETE BOUND (FND) CONCRETE BOUND W/ METAL DISK (FND) ( 1 0 0 ' ~ D E E D ) CONCRETE BOUND (FND) S 01°07'27" W 189.80'S 00°23'57" W 187.75' S 00°56'53" W 365.55' N 7 8 ° 5 9 ' 3 3 " E 2 9 8 . 0 9 ' ( M E A S U R E D ) MASS. HWY. BOUND N 7 8 ° 5 9 ' 3 3 " E 8 0 . 1 4 ' MAP 36, LOT 82.2.1 N/F JOAO SILVA VOLUME 31220, PAGE 309 (RESIDENTIAL USE; ZONE B2) MH WV DREW'S WAY (PRIVATE RIGHT OF WAY ~ 12' WIDTH) 2 STY. ECONOLODGE MOTEL No. 59 MAP 36, LOT 76 N/F DIPTI LLC VOLUME 27426, PAGE 307 (COMMERCIAL USE; ZONE B2) MAP 36, LOT 71 N/F ROSEANN KELLEHER VOLUME 21626, PAGE 104 (RESIDENTIAL USE; ZONE B1) MAP 36, LOT 82.2.2 N/F HUGH VARDAN & JOHN MOYLAN VOLUME 29158, PAGE 71 (RESIDENTIAL USE; ZONE B2) 1 9 3 3 S T A T E H I G H A W Y ~ L O 2 9 7 7 2 2 21 22 21 20 19 18 17 1 6 21 2 0 20 19 19 2 5 24 23 23 23 23 22 21 OHW OHW OHW OHW GM 1. 4 ' 25 2 4 24 2 3 23 2 2 22 21 20 19 12.4' GV GV DD D D D W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W G G G G G G G G G G G G G G W W W W W W G G W W T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T OHW OHW OHW OHW OHW OHW N 01°18'20" E 99.92' (100' ~ DEED) O H W O H W O H W O H W O H W O H W O H W O H W O H W O H W O H W OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW GM BH HEDGES COLUMN GUY GAS METER ELEC. METER GAS METER CHAIN LINK FENCE AC UNIT AC UNIT AC UNIT ICE 18 17 1 9 1 8 1 8 1 8 19 1 9 1 8 1 9 BOLLARDS BIT. PAVED DRIVEWAY "DREW'S WAY" SIGN BIT. PAVED PARKING AREA O V E R H E A D W I R E S ( T Y P . ) 5/8" WATE R S E R . 2" WATER G G G G G G G G G G G G G G G G G G G GAPPROXIMATE 2" PE GAS MAIN 6 " P E G A S M A I N WOOD GUARD RAIL C.O. OVERHANG BIT. PAVEMENT C O N C . W A L K C O N C . W A L K BIT. PAVED DRIVEWAY "BECKER'S PACKAGE STORE" 1 STY. W/F & MASONRY BUILDING No. 55 (ROUTE 28) LAWN MAP 36, LOT 79 51,026 S.F. (1.171 AC.) MAP 36, LOT 78 9,711 S.F. (0.223 AC.) MAP 36, LOT 77 37,669 S.F. (0.865 AC.) S 00°51'57" W 98.35' APPROXIMATE SEPTIC SYSTEM APPROX. 1/2" G A S S E R . UTILITY POLE (TYP.)(DENSE WOODS / BRUSH) (DENSE WOODS / BRUSH) EDGE OF PAVEMENT EDGE OF PAVEMENT WOOD FENCE VINYL FENCE G R A N I T E C U R B I N G ( T Y P . ) MAG-NAIL (FND) O H W O H W O H W O H W R O U T E 2 8 - M A I N S T R E E T ( S T A T E H I G H W A Y L A Y O U T 2 9 7 7 & 6 2 3 7 ) 12 ' A P P R O X . T E L E C O M D U C T ( T Y P . ) A P P R O X . 8 " W A T E R M A I N A P P R O X . 1 6 " W A T E R M A I N 2 STY. "RELAX INN" No. 41 METER PIT 2 0 ZO N E B 1 ZO N E B 2 ZONE B1 ZONE B2 LOD LOD LOD LOD LOD LO D LO D LO D LO D LOD LOD LOD LOD LOD LOD LOD LOD L O D LO D LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD L O D L O D L O D L O D L O D LOD L O D L O D L O D LOD L O D L O D L O D L O D L O D L O D L O D L O D LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLOD L O D L O D L O D LO D LO D LO D LO D LO D S 8 6 ° 4 2 ' 3 7 " W 8 0 . 6 0 ' 30' FRONT Y A R D SETBACK 25 ' S I D E Y A R D SE T B A C K TH-3 & 4 (DRAINAGE)REMOVE AND DISPOSE EXISTING SYSTEM IN ACCORDANCE WITH ALL LOCAL, STATE, AND FEDERAL LAW. EMPTY SYSTEM OF ALL CONTENTS, CRUSH AND FILL WITH COMMON BORROW PLACES IN 12" THICK LOOSE LIFTS COMPACTED TO 92% MODIFIED PROCTOR. REFER TO UTILITY PLAN FOR PROPOSED SEPTIC SYSTEM DESIGN. PLEASE ALSO NOTE THAT PROJECT WILL EVENTUALLY BE CONNECTED TO PUBLIC SEWER (SEE GENERAL NOTE 7). REMOVE AND DISPOSE EXISTING PAVEMENT (TYP.) PORTION OF EXISTING BUILDING TO BE RAZED; REFER TO ARCHITECTURAL PLAN FOR DETAILS REMOVE & DISPOSE EXISTING CURB REMOVE & DISPOSE EXISTING BOLLARDS INTERIOR LOT LINES TO BE ABANDONED; LOTS TO BE COMBINED PER ZONING BYLAW §104.3.5(5) AS AN 81X PERIMETER PLAN REMOVE AND DISPOSE EXISTING UTILITY POLE AND ASSOCIATED OVERHEAD WIRES; COORDINATION WITH UTILITY COMPANY REQUIRED REMOVE AND RELOCATE "DREW'S WAY SIGN; SEE SITE PLAN CLEAR AND GRUB (TYP.) BUILDING SETBACKS SHOWN FOR FUTURE COMBINED LOTS VIA ZONING BYLAW §104.3.5(5) AS AN 81X PERIMETER PLAN BENCHMARK: NAIL (SET) IN UTILITY POLE ELEV: 20.76' (NAVD 88) 30 ' F R O N T Y A R D SE T B A C K PROPOSED TREE LINE (TYP.) TH-1 & TH-2 (SEPTIC) SHEET DESIGNED BY:WMLJR DRAWN BY:SEK/SD CHECKED BY:JAC DATE:NOV. 2024 PROJECT NO:19-19v REVISIONS: NO.DATE.DESCRIPTION 1 4/2025 DESIGN REVIEW 2 2/5/2026 PERMIT SET BE C K E R ' S P A C K A G E S T O R E 55 R O U T E 2 8 WE S T Y A R M O U T H , M A S S A C H U S E T T S AP 3 6 , LO T S 7 7 , 7 8 & 7 9 OF 8Q: \ 1 9 - 1 9 A h a r o n i a n & A s s o c i a t e s \ 1 9 - 1 9 v B e c k e r s P a c k a g e S t o r e \ A C A D \ B e c k e r ' s P a c k a g e S t o r e [ W o r k i n g P l a n ] - R 3 . d w g F e b . 2 4 , 2 0 2 6 1 1 : 4 5 a m PRELIMINARY, NOT FOR CONSTRUCTION JC E JC E JO E C A S A L I E N G I N E E R I N G , I n c . Ci v i l ∙ S i t e D e v e l o p m e n t ∙ T r a n s p o r t a t i o n Dr a i n a g e ∙ W e t l a n d s ∙ I S D S ∙ T r a f f i c ∙ F l o o d p l a i n 30 0 P o s t R o a d , W a r w i c k , R I 0 2 8 8 8  0       3 0 0  0       3  3 F A ; W W W . J O E C A S A L I . C O 0 EXISTING CONDITIONS & SITE PREP. PLAN 2 SCALE (FEET) 0 1 INCH = FT 10 20 40 80 201-888-344-7233 1-888-DIG-SAFETO ANY EXCAVATION CALL DIGSAFE AT: BE DONE BY THE APPROPRIATE UTILITY COMPANY OR MUNICIPALITY PRIOR EXISTING DOCUMENTATION AND MAY NOT BE ACCURATE. EXACT LOCATION TO LOCATION OF EXISTING UTILITIES SHOWN, ARE FROM GATE LOCATION AND WORKING DAYS NOTICE PROTECT YOURSELF, GIVE THREE MA. MAINLAND (NAD 83) LEGEND: UP#T2 ABUTTING PROPERTY LINE PROPOSED CONTOUR EXISTING CONTOUR EXISTING UTILITY POLE EXISTING PROPERTY LINE 100 100 PROPOSED DRAINAGE MANHOLED EXISTING CATCH BASIN BUILDING SETBACK LINE EXISTING CURB PROPOSED CURB EXISTING METAL FENCE EXISTING DRAIN LINEDDD PROPOSED DRAIN LINEDDD EXISTING DRAINAGE MANHOLED PROPOSED CATCH BASIN PROPOSED UTILITY POLE EXISTING TELECOM DUCTBANKTELTEL EXISTING ELECTRIC DUCTBANKEEE PROPOSED GAS LINEGASGAS CHAIN LINK FENCE WETLAND EDGE WETLAND FLAGWF FDC H/C WG EXISTING SEWER LINE TEST HOLE EXISTING SEWER MANHOLE S S S S NOW OR FORMERLYN/F TREELINE LIMIT OF DISTURBANCELODLOD EXISTING WATER LINEWWW WATER GATE SILT FENCE PROPOSED WATER LINEWWW WV PROPOSED SEWER LINESSS PROPOSED SEWER MANHOLES EXISTING TREE BOLLARD HYDRANT LAMP POLE FIRE DEPTMENT CONTROL EXISTING HANDICAP PROPOSED HANDICAP WATER VALVE ZONING CRITERIA ZONING DISTRICT MINIMUM LOT AREA MINIMUM FRONTAGE MINIMUM FRONT YARD MINIMUM SIDE YARD MINIMUM REAR YARD MAXIMUM BUILDING COVERAGE (%) MAXIMUM IMPERVIOUS COVERAGE (%) SHAPE FACTOR1 REQUIRED B-2 20,000 SF 125 FT 30 FT 25 FT 20 FT 25% 70% 22 EXISTING LOT 77 GENERAL NOTES: 1.THIS PLAN IS BASED ON A OCTOBER 2024 BOUNDARY & TOPOGRAPHIC SURVEY PLAN PREPARED BY WATERMAN ENGINEERING CO. 2.THE LOCATION AND DEPTH OF EXISTING UTILITIES ARE APPROXIMATE AND HAVE BEEN PLOTTED FROM THE LATEST AVAILABLE INFORMATION. THE UTILITY LOCATIONS ARE APPROXIMATE AND MAY NOT BE ALL INCLUSIVE. THE CONTRACTOR SHALL CHECK AND VERIFY THE LOCATIONS OF ALL EXISTING UTILITIES, BOTH OVERHEAD AND UNDERGROUND, AND "DIG-SAFE" MUST BE NOTIFIED PRIOR TO COMMENCING ANY CONSTRUCTION OPERATIONS. RESTORATION AND REPAIR OF DAMAGE TO EXISTING UTILITIES SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR WITH NO ADDITIONAL COST THE OWNER. NO EXCAVATION SHALL COMMENCE UNTIL ALL INVOLVED UTILITY COMPANIES AND/OR CITY WHOSE FACILITIES MIGHT BE AFFECTED BY ANY WORK TO BE PERFORMED BY THE CONTRACTOR ARE NOTIFIED AT LEAST 72 HOURS IN ADVANCE. 3.THIS SITE LIES IN ZONE X (AREAS DETERMINED TO BE OUTSIDE OF THE 0.2% ANNUAL CHANCE FLOOD), AS SHOWN ON THE FIRM MAP FOR BARNSTABLE COUNTY, MASSACHUSETTS (ALL JURISDICTIONS) PANEL 567 OF 875, TOWN OF YARMOUTH, MAP NUMBERS 25001C0567K, EFFECTIVE DATE: JULY 16, 2014. 4.SOILS EXISTING ON THE SITE CONSIST ENTIRELY OF CARVER COARSE SAND, 3-8% SLOPES (252B). 5.THESE PREMISES MAY BE SUBJECT TO THE FOLLOWING EASEMENTS, RIGHTS OF WAY OR AGREEMENTS OF RECORD: ·RIGHTS AND RIGHTS OF OTHERS IN, TO AND ACROSS THAT 12' WIDE PRIVATE RIGHT OF WAY KNOWN AS "DREW'S WAY" AS DESCRIBED IN VOLUME 460, PAGE 431 & VOLUME 456, PAGE 25 ·EASEMENTS MAY EXIST FOR THE UTILITY POLES & OVERHEAD WIRES AS SHOWN (NO RECORDS FOUND) 6.WATER, GAS, AND TELECOMMUNICATIONS ARE AVAILABLE TO THE PROJECT SITE VIA MAIN STREET. ELECTRIC SERVICES ARE AVAILABLE VIA OVERHEAD LINES ALONG MAIN STREET. SEWER IS NOT CURRENTLY AVAILABLE TO THE PROJECT SITE. 7.THESE PROPERTIES ARE IN THE PROCESS OF OBTAINING SEWER CONNECTIONS AS SHOWN WITHIN "PHASE 1 - CONTRACT NO. 6" OF THE TOWN OF YARMOUTH, MASSACHUSETTS PROPOSED WASTEWATER COLLECTION AND WATER RESOURCE RECOVERY FACILITIES PROJECT, PROJECT NO. CWSRF - 8349/6 , AUGUST, 2024, AS SHOWN ON THE PROPOSED SEWER DESIGN PLANS CURRENTLY UNDER REVIEW WITH THE TOWN OF YARMOUTH. B-2 37,669 SF 80.14 FT2 12.4 FT2 1.4 FT2 >20 FT 8% 16.5% 22 EXISTING LOT 78 B-2 9,711 SF2 99.58 FT2 N/A N/A N/A N/A 69% 16.4 EXISTING LOT 79 B-2 51,026 SF N/A N/A N/A N/A N/A 12.6% 29.8 NOTES: 1.SHAPE FACTOR SHALL BE OBTAINED BY DIVIDING THE SQUARE OF THE LOT PERIMETER (P), MEASURED IN FEET, BY THE AREA OF THE LOT (A), MEASURED IN SQUARE FEET (I.E. P2 ÷ A). 2.PRE-EXISTING, NON-CONFORMING CONDITION EXISTING LOTS 77-79 B-2 98,406 SF 179.72 FT 12.4 FT2 1.4 FT2 >20 FT 3% 19.7% 26.1 X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X EM WV GV MAP 36, LOT 82.1 N/F KISHOR K. PATEL VOLUME 12505, PAGE 226 (COMMERCIAL USE; ZONE B2) S 8 6 ° 4 2 ' 3 7 " W 8 0 . 6 0 ' MASS. HWY. BOUND MAP 36, LOT 82.2.1 N/F JOAO SILVA VOLUME 31220, PAGE 309 (RESIDENTIAL USE; ZONE B2) MH WV DREW'S WAY (PRIVATE RIGHT OF WAY ~ 12' WIDTH) 2 STY. ECONOLODGE MOTEL No. 59 MAP 36, LOT 76 N/F DIPTI LLC VOLUME 27426, PAGE 307 (COMMERCIAL USE; ZONE B2) MAP 36, LOT 71 N/F ROSEANN KELLEHER VOLUME 21626, PAGE 104 (RESIDENTIAL USE; ZONE B1) MAP 36, LOT 82.2.2 N/F HUGH VARDAN & JOHN MOYLAN VOLUME 29158, PAGE 71 (RESIDENTIAL USE; ZONE B2) 1 9 3 3 S T A T E H I G H A W Y ~ L O 2 9 7 7 OHW OHW OHW OHW GM GV GV DD D D D W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W G G G G G G G G G G G G G G W W W W W W G G W W T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T OHW OHW OHW OHW OHW OHW O H W O H W O H W O H W O H W O H W O H W O H W O H W O H W O H W OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW GM BH HEDGES COLUMN GUY GAS METER ELEC. METER GAS METER CHAIN LINK FENCE AC UNIT AC UNIT BIT. PAVED DRIVEWAY O V E R H E A D W I R E S ( T Y P . ) 5/8" WATE R S E R . 2" WATER G G G G G G G G G G G G G G G G G G G GAPPROXIMATE 2" PE GAS MAIN 6 " P E G A S M A I N C O N C . W A L K C O N C . W A L K BIT. PAVED DRIVEWAY LAWN APPROX. 1/2" G A S S E R . UTILITY POLE (TYP.) (DENSE WOODS / BRUSH) EDGE OF PAVEMENT EDGE OF PAVEMENT WOOD FENCE VINYL FENCE G R A N I T E C U R B I N G ( T Y P . ) R O U T E 2 8 - M A I N S T R E E T ( S T A T E H I G H W A Y L A Y O U T 2 9 7 7 & 6 2 3 7 ) 12 ' A P P R O X . T E L E C O M D U C T ( T Y P . ) A P P R O X . 8 " W A T E R M A I N A P P R O X . 1 6 " W A T E R M A I N 2 STY. "RELAX INN" No. 41 METER PIT 20 ' ( T Y P . ) 24 ' ( T Y P . ) 20 ' ( T Y P . ) ±103' (REFER TO ARCHITECTURAL PLAN) ±4 7 . 5 ' ZO N E B 1 ZO N E B 2 ZONE B1 ZONE B2 D 3 5 3 ACCESS TO RESIDENTIAL STAIRWELL ACCESS TO BASEMENT STAIRWELL PROPOSED 2ND FLOOR (2 RESIDENTIAL UNITS) TOTAL AREA: 2,849 SF LIMITS OF 2ND FLOOR "BECKER'S PACKAGE STORE" FIRST FLOOR EXISTING: 935 SF ADDITION: 4,180 SF TOTAL AREA: 5,115 SF BASEMENT EXISTING: 95 SF ADDITION: 4,079 SF TOTAL AREA: 4,174 SF MAIN ENTRANCE (REFER TO ARCHITECTURAL PLAN) LOADING ZONE PROPOSED CONCRETE CURB (SEE DETAIL - TYP.) PROPOSED BITUMINOUS CONCRETE PAVEMENT (TYP.) PROPOSED 5'x5' CEMENT CONCRETE LANDING (TYP.) PROPOSED CEMENT CONCRETE SIDEWALK (SEE DETAIL) PROPOSED STREET TREES (TYP.) SPECIFIC PLANTINGS TO BE COORDINATED WITH MASSDOT PROPOSED (7) EVERGREEN BUFFER PLANTINGS, JUNIPERUS VIRGINIANA, EASTERN RED CEDAR, SPACED 20-FT O.C., 3" CALIPER PROPOSED LANDSCAPED AREA LOAM AND SEED ALL DISTURBED AREAS (TYP.) LIMITS OF STORMWATER MANAGEMENT AREA PROPOSED DUMPSTER CONCRETE PAD WITH SOLID WOOD ENCLOSURE (TYP. - SEE DETAIL) STORMWATER MANAGEMENT AREA (TYP.) PROPOSED HANDICAP PARKING SYMBOL AND STRIPING (TYP - SEE DETAIL) 4" WHITE EPOXY PAVEMENT MARKING (TYP.) PROPOSED WHEELCHAIR RAMP WITH DETECTABLE WARNING PANEL (TYP.) (E 107.2.0 & E 107.6.5) 4" WHITE EPOXY PAVEMENT MARKING (TYP.) PROPOSED CONCRETE CURB (SEE DETAIL - TYP.) 7 20' MIN. LANDSCAP E D BUFFER S 01°19'37" W 155.73' S 01°07'27" W 189.80' S 00°23'57" W 187.75' S 00°51'57" W 98.35' N 01°18'20" E 611.54' 12.3' 7. 5 ' 4 5 S LIMITS OF PROPOSED ON-SITE WASTEWATER TREATMENT SYSTEM PROPOSED CONCRETE CURB FLUSH WITH ASPHALT (SEE DETAIL - TYP.) 12'12.9' 9' 5' PARKING COUNT; DO NOT PAINT (TYP.) RELOCATED STREET SIGN (TYP.) FUTURE ROADWAY IMPROVEMENTS CONSISTING OF BIKE LANES AND GRASS STRIPS BASED ON PENDING MASSDOT CORRIDOR PROJECT (TYP.) 3 10'8'7'10'8'8'8'10'10'27.72'10'24'20'24' 33 . 7 5 ' 12 ' PROPOSED (4) AMELANCHIER ARBOREA, DOWNY SERVICEBERRY, SPACED 20-FT O.C., 2.5" CALIPER N 7 8 ° 5 9 ' 3 3 " E 1 7 9 . 7 2 ' VARIOUS SHRUB AND FLOWERING PLANTINGS (TYP.) R 3 ' ( T Y P . ) R5' R 5 ' 25.55' SHEET DESIGNED BY:WMLJR DRAWN BY:SEK/SD CHECKED BY:JAC DATE:NOV. 2024 PROJECT NO:19-19v REVISIONS: NO.DATE.DESCRIPTION 1 4/2025 DESIGN REVIEW 2 2/5/2026 PERMIT SET BE C K E R ' S P A C K A G E S T O R E 55 R O U T E 2 8 WE S T Y A R M O U T H , M A S S A C H U S E T T S AP 3 6 , LO T S 7 7 , 7 8 & 7 9 OF 8Q: \ 1 9 - 1 9 A h a r o n i a n & A s s o c i a t e s \ 1 9 - 1 9 v B e c k e r s P a c k a g e S t o r e \ A C A D \ B e c k e r ' s P a c k a g e S t o r e [ W o r k i n g P l a n ] - R 3 . d w g F e b . 2 4 , 2 0 2 6 1 1 : 4 5 a m PRELIMINARY, NOT FOR CONSTRUCTION JC E JC E JO E C A S A L I E N G I N E E R I N G , I n c . Ci v i l ∙ S i t e D e v e l o p m e n t ∙ T r a n s p o r t a t i o n Dr a i n a g e ∙ W e t l a n d s ∙ I S D S ∙ T r a f f i c ∙ F l o o d p l a i n 30 0 P o s t R o a d , W a r w i c k , R I 0 2 8 8 8  0       3 0 0  0       3  3 F A ; W W W . J O E C A S A L I . C O 0 SITE & LANDSCAPE PLAN 3 SCALE (FEET) 0 1 INCH = FT 10 20 40 80 20 MA. MAINLAND (NAD 83) PARKING CALCULATION Per Town of Yarmouth Zoning Bylaw, Section 301.5 Table of Parking Demand: USE: MERCANTILE REQUIRED: 1 SPACE PER 7 OCCUPANTS 50 OCCUPANTS * (1 SPACE / 7 OCCUPANTS) = 7.14 SPACES USE: RESIDENTIAL, 1 & 2 FAMILY REQUIRED: 2 SPACES/UNIT 2 UNITS * (2 SPACES / UNIT) = 4 SPACES TOTAL PARKING SPACES REQUIRED = 12 SPACES PARKING SPACES PROPOSED = 30 SPACES ADA ACCESSIBLE PARKING SPACES REQUIRED: 2 SPACE ADA ACCESSIBLE PARKING SPACES PROPOSED: 2 SPACE TOWN OF YARMOUTH ZONING BYLAWS SECTION 104.3.2(3): A.OTHER LAWFULLY PRE-EXISTING, NON-CONFORMING STRUCTURES MAY BE ALTERED, EXTENDED, RAZED AND REPLACED BY SPECIAL PERMIT FROM THE BOARD OF APPEALS IF IT IS DETERMINED THAT: 1.CONFORMS TO THE CURRENT DIMENSIONAL REQUIREMENTS OF THE BYLAW OR DOES NOT INCREASE THE EXISTING NON-CONFORMING NATURE OF THE STRUCTURE, OR; 2.WILL NOT BE SUBSTANTIALLY MORE DETRIMENTAL TO THE NEIGHBORHOOD, ZONING DISTRICT, OR TOWN B.THE EXTENSION, ALTERATION, OR RAZE AND REPLACEMENT WILL NOT CAUSE OR CONTRIBUTE TO ANY UNDUE NUISANCE, HAZARD OR CONGESTION, AND; C.STRICT ENFORCEMENT OF THE CURRENT BYLAWS WOULD RESULT IN UNDUE HARDSHIP TO THE PROPERTY OR ITS OWNER SPECIAL PERMIT REQUESTED WITH VARIANCE TO EXTEND/MAINTAIN THE EXISTING NON-CONFORMING NATURE OF THE EXISTING BUILDING (SIDE YARD & FRONT YARD) SPECIAL PERMIT REQUESTED TO ALLOW A DUPLEX WITHIN THE B2 ZONING DISTRICT 1 ZONING CRITERIA ZONING DISTRICT MINIMUM LOT AREA MINIMUM FRONTAGE MINIMUM FRONT YARD MINIMUM SIDE YARD MINIMUM REAR YARD MAXIMUM BUILDING COVERAGE (%) MAXIMUM IMPERVIOUS COVERAGE (%) SHAPE FACTOR1 REQUIRED B-2 20,000 SF 125 FT 30 FT 25 FT 20 FT 25% 70% 22 EXISTING LOT 77 B-2 37,669 SF 80.14 FT2 12.4 FT2 1.4 FT2 N/A 8% 16.5% 22 EXISTING LOT 78 B-2 9,711 SF2 99.58 FT2 N/A N/A N/A N/A 69% 16.4 EXISTING LOT 79 B-2 51,026 SF N/A N/A N/A N/A N/A 12.6% 29.8 NOTES: 1.SHAPE FACTOR SHALL BE OBTAINED BY DIVIDING THE SQUARE OF THE LOT PERIMETER (P), MEASURED IN FEET, BY THE AREA OF THE LOT (A), MEASURED IN SQUARE FEET (I.E. P2 ÷ A). 2.PRE-EXISTING, NON-CONFORMING CONDITION 3.RELIEF REQUESTED TO EXTEND A PRE-EXISTING, NON-CONFORMING CONDITION 4.CORNER LOTS ARE CONSIDERED TO HAVE TWO FRONT YARD SETBACKS AND TWO SIDE YARD SETBACKS. THE FRONT YARD SETBACK FOR CORNER LOTS MAY BE REDUCED TO 25' TO ACCOMMODATE PARKING IN THE REAR OR SIDE OF THE BUILDING. EXISTING LOTS 77-79 B-2 98,406 SF 179.72 FT 12.4 FT2 1.4 FT2 N/A 3% 19.7% 26.1 PROPOSED LOTS 77-79 B-2 98,406 SF 179.72 FT 12.3 FT2 7.5 FT3 N/A 5.2% 25.6% 26.1 2 LANDSCAPE NOTES: 1.GUARANTEE THAT, UPON COMPLETION AND FINAL ACCEPTANCE, LANDSCAPE PLANTINGS CONFORM TO REQUIREMENTS OF CONTRACT DOCUMENTS. PROVIDE A WARRANTY FOR TREE PLANTINGS FOR A MINIMUM OF TWO (2) YEARS, INCLUDING TWO (2) CONTINUOUS GROWING SEASONS. COMMENCE WARRANTY ON DATE IDENTIFIED IN THE 'CERTIFICATE OF FINAL COMPLETION'. 2.REPLACEMENTS: PLANTS OF SAME SIZE AND SPECIES AS SPECIFIED, PLANTED IN THE NEXT GROWING SEASON, WITH NEW WARRANTY AND EXTENDED MAINTENANCE SERVICE COMMENCING ON THE DATE OF REPLACEMENT. 3.PLANT MATERIALS SHALL BE OF SIZE AND CALIPER REQUIRED AND CONFORM TO THE REQUIREMENTS DESCRIBED IN THE LATEST EDITION OF AMERICAN STANDARD FOR NURSERY STOCK, PUBLISHED BY THE AMERICAN ASSOCIATION OF NURSERYMEN. 4.PLANTS OF OTHER KINDS THAN THOSE NAMED IN THE PLANT SCHEDULE SHALL NOT BE ACCEPTED WITHOUT APPROVAL. REPLACEMENT PLANTS LARGER IN SIZE THAN EXISTING MAY BE USED IF APPROVED BY THE A/E, PROVIDED USE OF LARGER PLANTS DOES NOT INCREASE CONTRACT PRICE. 5.A PROFESSIONAL HORTICULTURIST/NURSERYMAN SHALL BE CONSULTED TO DETERMINE THE PROPER TIME TO MOVE AND INSTALL PLANT MATERIAL SO THAT STRESS TO THE PLANT IS MINIMIZED. PLANTING OF DECIDUOUS MATERIAL MAY BE CONTINUED DURING WINTER MONTHS PROVIDED THERE IS NO FROST IN THE GROUND AND FROST-FREE TOPSOIL PLANTING MIXTURES ARE USED. 6.UNLESS OTHERWISE APPROVED BY THE A/E, ALL PLANTS SHALL BE NURSERY GROWN IN ACCORDANCE WITH GOOD HORTICULTURAL PRACTICES AND SHALL HAVE BEEN GROWN UNDER CLIMATIC CONDITIONS SIMILAR TO THOSE IN THE LOCALITY OF THE PROJECT FOR AT LEAST TWO (2) YEARS. 7.SET PLANTS PLUMB AND AT SUCH A LEVEL THAT AFTER SETTLEMENT THEY BEAR THE SAME RELATION TO THE SURROUNDING GROUND AS THEY BORE TO THE GROUND FROM WHICH THEY WERE DUG. SETTLE BACKFILL MATERIAL FOR PLANTS, THOROUGHLY & PROPERLY, BY FIRMING OR TAMPING. ACCOMPANY BACKFILLING WITH THOROUGH WATERING UNLESS OTHERWISE APPROVED. FORM SAUCER CAPABLE OF HOLDING WATER AROUND INDIVIDUAL PLANTS. 8.FERTILIZE SHRUB BEDS WITH 10-6-4 FERTILIZER AT THE RATE OF 3 POUNDS PER 100 SQUARE FEET OF SURFACE AREA, BROAD CAST. APPLY THE FERTILIZER UNIFORMLY TO THE SURFACE BEDS AND WORK INTO THE UPPER TWO (2) INCHES OF SOIL. FERTILIZE INDIVIDUAL TREES AT THE RATE OF ONE (1) AGRIFORM PELLET PER INCH OF TREE DIAMETER (FOLLOW MANUFACTURER'S WRITTEN INSTRUCTIONS). APPLY A SECOND APPLICATION OF FERTILIZER TO ALL PLANT ITEMS AT THE SAME SPECIFIED RATES OVER THE MULCH AT THE END OF AN EIGHT WEEK PERIOD. 9.CONTAINER GROWN MATERIALS: REMOVE PLANT FROM CONTAINER AND "BUTTERFLY" ROOT BALL OR OTHERWISE SPREAD OUT ROOTS ON SETTING MOUND. BACKFILL SHALL BE SIFTED THROUGH THEM AND SOLIDLY FIRMED. 10.AFTER PLANTING PRUNE ONLY BROKEN OR DEFORMED BRANCHES AND IN SUCH MANNER AS TO PRESERVE NATURAL CHARACTER OF PLANT. 11.IMMEDIATELY AFTER PLANTING, STAKE TREES OVER FIVE (5) FEET AS INDICATED ON DETAIL DRAWING INDICATED OR APPROVED BY THE OWNERS REPRESENTATIVE. REMOVE STAKES AT THE END OF GUARANTEE PERIOD. 12.MULCH SHALL BE APPLIED A MINIMUM OF THREE (3) INCHES IN DEPTH IN ALL PLANTING BEDS, AS INDICATED ON THE DRAWINGS. 13.THE PLANTS SHALL BE WATERED IMMEDIATELY FOLLOWING PLANTING, PREFERABLY WHEN TWO THIRDS OF THE BACKFILL HAS BEEN PLACED SO ALL AIR POCKETS ARE REMOVED AND THE PLANT PROPERLY SET. ADDITIONAL WATERING SHALL BE MADE AT LEAST ONCE EVERY THREE (3) WEEKS UNLESS OTHERWISE DIRECTED UNTIL FINAL ACCEPTANCE OF THE PLANT MATERIAL. 14.UNLESS OTHERWISE SPECIFIED, CONTRACTOR TO LOAM AND SEED ALL DISTURBED AREAS. 15.TREE PRUNING NOTE: STREET TREES SHOULD BE PRUNED TO MAINTAIN A MINIMAL BRANCH HEIGHT OF 7' WITHIN TWO (2) YEARS OF INSTALLATION OF THE TREE. 16.LANDSCAPE ESTABLISHMENT AND MAINTENANCE NOTE: CONTRACTOR SHALL ENSURE THAT ALL LAWN AREAS AND PLANTINGS ARE FULLY ESTABLISHED AND ACCEPTABLE TO THE OWNER'S REPRESENTATIVE PRIOR TO RELINQUISHING THEIR RESPONSIBILITIES FOR MAINTENANCE OF THESE AREAS. 17.TREE PROTECTION NOTE: NO MATERIAL, TEMPORARY SOIL DEPOSIT OR EXCAVATION SHALL OCCUR WITHIN FOUR FEET OF SHRUBS OR WITHIN TWO FEET OF THE DRIP LINE OF ANY SHRUBS OR TREES TO REMAIN. ANY RETAINED EXISTING VEGETATION SHALL BE PROTECTED AS PER NORTH KINGSTOWN ZONING ORDINANCE, SECTION 21-277, SUBSECTION 3a: PROTECTION OF EXISTING PLANTINGS AND SITE FEATURES. PLANT SCHEDULE SYMBOL CODE BOTANICAL / COMMON NAME SIZE CONTAINER QTY DETAIL REMARKS DECIDUOUS TREES AMC Amerlanchier canadensis / Serviceberry, shadbush 3" Cal.B&B 3 NYS Nyssa sylvatica / Black Tupelo 3" Cal.B&B 2 EVERGREEN TREES JV2 Juniperus virginiana / Eastern Red Cedar 6` Ht.B&B 7 3" Cal. min. SHRUBS RHP Rhododendron periclymenodies / Pink Azalea, pinxterbloom 3 gal CONT.6 COP Comptonia peregrina / Sweet Fern 2 - 3 gal CONT.22 IAH Ilex opaca / American Holly 3-5 gal CONT.5 PRM Prunus maritima / Beach Plum 2-3 gal CONT.13 PERENNIALS MON Monardo fisulosa / Wild Bergamot 1 gal.CONT.11 CAR Carex ensylvanica / Pennsylvania Sedge 1 gal.CONT.14 NOTES 1.PLANT ALL DISTURBED AREAS WITH LOAM AND SEED UNLESS NOTED OTHERWISE. 2.INSTALL BIODEGRADABLE EROSION CONTROL MAT IN ALL SLOPES GREATER THAN 3:1. X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X EM WV GV MAP 36, LOT 82.1 N/F KISHOR K. PATEL VOLUME 12505, PAGE 226 (COMMERCIAL USE; ZONE B2) MASS. HWY. BOUND MAP 36, LOT 82.2.1 N/F JOAO SILVA VOLUME 31220, PAGE 309 (RESIDENTIAL USE; ZONE B2) MH WV DREW'S WAY (PRIVATE RIGHT OF WAY ~ 12' WIDTH) 2 STY. ECONOLODGE MOTEL No. 59 MAP 36, LOT 76 N/F DIPTI LLC VOLUME 27426, PAGE 307 (COMMERCIAL USE; ZONE B2) MAP 36, LOT 71 N/F ROSEANN KELLEHER VOLUME 21626, PAGE 104 (RESIDENTIAL USE; ZONE B1) MAP 36, LOT 82.2.2 N/F HUGH VARDAN & JOHN MOYLAN VOLUME 29158, PAGE 71 (RESIDENTIAL USE; ZONE B2) 1 9 3 3 S T A T E H I G H A W Y ~ L O 2 9 7 7 2 2 21 22 21 20 19 18 17 1 6 21 2 0 20 19 19 2 5 24 23 23 23 23 22 21 OHW OHW OHW OHW GM 25 2 4 24 2 3 23 2 2 2 1 22 21 20 19 GV GV DD D D D W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W G G G G G G G G G G G G G G W W W W W W G G W W T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T OHW OHW OHW OHW OHW OHW O H W O H W O H W O H W O H W O H W O H W O H W O H W O H W O H W OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW GM BH HEDGES COLUMN GUY GAS METER ELEC. METER GAS METER CHAIN LINK FENCE AC UNIT AC UNIT 18 17 1 9 1 8 1 8 1 8 19 1 9 1 8 1 9 BIT. PAVED DRIVEWAY O V E R H E A D W I R E S ( T Y P . ) 5/8" WATE R S E R . 2" WATER G G G G G G G G G G G G G G G G G G G GAPPROXIMATE 2" PE GAS MAIN 6 " P E G A S M A I N C O N C . W A L K C O N C . W A L K BIT. PAVED DRIVEWAY LAWN APPROX. 1/2" G A S S E R . UTILITY POLE (TYP.) (DENSE WOODS / BRUSH) EDGE OF PAVEMENT EDGE OF PAVEMENT WOOD FENCE VINYL FENCE G R A N I T E C U R B I N G ( T Y P . ) R O U T E 2 8 - M A I N S T R E E T ( S T A T E H I G H W A Y L A Y O U T 2 9 7 7 & 6 2 3 7 ) 12 ' A P P R O X . T E L E C O M D U C T ( T Y P . ) A P P R O X . 8 " W A T E R M A I N A P P R O X . 1 6 " W A T E R M A I N 2 STY. "RELAX INN" No. 41 METER PIT 2 0 ZO N E B 1 ZO N E B 2 ZONE B1 ZONE B2 LOD LOD LOD LOD LOD LO D LO D LO D LO D LOD LOD LOD LOD LOD LOD LOD LOD L O D LO D LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD L O D L O D L O D L O D L O D LOD L O D L O D L O D LOD L O D L O D L O D L O D L O D L O D L O D L O D LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLOD L O D L O D L O D LO D LO D LO D LO D LO D D D D D D D PROPOSED BUILDING AREA = 5,115 S.F. FFE = 19.50 D 19.50 18.50 19.5019.5019.50 19.50 19.2619.26 D PROPOSED 12" WIDE REVEAL TRENCH DRAIN SYSTEM WITH STEEL FRAME ZURN Z882 OR EQUAL A A PROPOSED INFILTRATION BASIN (SEE DETAILS) PROPOSED TOPOGRAPHIC DEPRESSION EXTENSION 102 LF - 8" ADS N-12 HDPE PIPE S= 0.03 FTT/F BLDG. INV.: 18.50 8" ADS N-12 HDPE PIPE TO BE MITER TO MATCH SLOPE INV.= 15.50 8" HDPE 45°ELBOW 8-INCHES DEEP CLASS R-3 RIPRAP ATOP 6-INCHES OF 3 4 -INCH CRUSHED STONE BEDDING ATOP GEOTEXTILE FILTER FABRIC (MIRAFI 140N, OR APPROVED EQUAL); EXTENDING TO BOTTOM OF BASIN AND SLOPE PROPOSED SEDIMENT FOREBAY (SEE DETAILS) PROPOSED CONCRETE WEIRS SPILLWAY (TYP - SEE DETAILS) DMH #1 PROPOSED NYLOPLAST 24" DRAIN BASIN WITH 24" STANDARD FRAME, GRATE, & ENVIROHOOD RIM: 18.60 INV. IN: 16.95 INV. OUT: 16.95 SUMP: 14.95 (SEE DETAILS) PROPOSED UNDERGROUND CRUSHED STONE INFILTRATION TRENCH (TYP.) (SEE DETAILS) 19.15 TH-3 & 4 (DRAINAGE) SS S S S S FM FM FM FM FM F M TH-1 & TH-2 (SEPTIC) TC: 19.38 BC: 19.00 19.30 19.00 TC: 19.38 BC: 19.00 19.00 TC: 19.38 BC: 19.00 19.00 TC: 19.50 BC: 19.15 17.50 TC: 19.38 BC: 19.00 TC: 19.50 BC: 19.00 1 8 19 18 1 8 . 5 16 . 5 16 . 5 15 . 5 17.5 18 . 5 1 8 15 . 5 16 . 5 19 18.5 1 9 19 19 18.5 1 8 18 25 16 14 . 5 14 . 5 16 . 5 18 . 5 17 . 5 20 21 22 23 19 18 17.5 16 17 19 20 21 22 19 20 21 22 23 23 24 24 24 1 9 1 8 . 7 5 18 19 SHEET DESIGNED BY:WMLJR DRAWN BY:SEK/SD CHECKED BY:JAC DATE:NOV. 2024 PROJECT NO:19-19v REVISIONS: NO.DATE.DESCRIPTION 1 4/2025 DESIGN REVIEW 2 2/5/2026 PERMIT SET BE C K E R ' S P A C K A G E S T O R E 55 R O U T E 2 8 WE S T Y A R M O U T H , M A S S A C H U S E T T S AP 3 6 , LO T S 7 7 , 7 8 & 7 9 OF 8Q: \ 1 9 - 1 9 A h a r o n i a n & A s s o c i a t e s \ 1 9 - 1 9 v B e c k e r s P a c k a g e S t o r e \ A C A D \ B e c k e r ' s P a c k a g e S t o r e [ W o r k i n g P l a n ] - R 3 . d w g F e b . 2 4 , 2 0 2 6 1 1 : 4 5 a m PRELIMINARY, NOT FOR CONSTRUCTION JC E JC E JO E C A S A L I E N G I N E E R I N G , I n c . Ci v i l ∙ S i t e D e v e l o p m e n t ∙ T r a n s p o r t a t i o n Dr a i n a g e ∙ W e t l a n d s ∙ I S D S ∙ T r a f f i c ∙ F l o o d p l a i n 30 0 P o s t R o a d , W a r w i c k , R I 0 2 8 8 8  0       3 0 0  0       3  3 F A ; W W W . J O E C A S A L I . C O 0 GRADING & DRAINAGE PLAN 4 SCALE (FEET) 0 1 INCH = FT 10 20 40 80 20 MA. MAINLAND (NAD 83) PROPOSED MIRAFI 140N FILTER FABRIC AROUND THE OUTER EDGE OF STONE 8" PERFORATED ADS HDPE PIPE (PERFORATIONS UP) INV. IN: 16.95 14"14" 6" 36" 24" PROPOSED 3/4" DOUBLE WASHED CRUSHED STONE COMMON BORROW 6" LOAM & SEED DESCRIPTION 100 YEAR STORM 25 YEAR STORM 10 YEAR STORM 2 YEAR STORM 1 YEAR STORM TOP OF BASIN BOTTOM OF BASIN ELEV. 17.50 14.50 15.05 15.58 16.76 17.25 17.35 INFLTRATION BASIN INFILTRATION BASIN 17.85 x x SEDIMENT FOREBAY 30 LF - BROAD CRESTED CONCRETE WEIR WITH 3" REVEAL (TOP OF CURB = EL. 17.35) 4" SANDY LOAM & SEED (TYP.) 3 1 EXISTING GRADE PROPOSED PRECAST CONCRETE CURB FLUSH WITH ASPHALT 3 1 3 1 4" SANDY LOAM & SEED (TYP.) x 17.85 x PROPOSED EXISTING DEPRESSION EXTENSION 2 1 4" SANDY LOAM & SEED (TYP.) 16.50x 14.50 16.00 30 LF - BROAD CRESTED CONCRETE WEIR WITH 3" REVEAL (TOP OF CURB = EL. 17.21) E X I S T I N G G R A D E 3 1 PROPOSED BITUMINOUS CONCRETE PARKING LOT UNCOMPACTED SUBGRADE (TYP.); CONTRACTOR MUST NOTIFY DESIGN ENGINEER OF RECORD FOR REVIEW AND APPROVAL OF SUBGRADE PRIOR TO PLACEMENT OF LOAM DESCRIPTION 100 YEAR STORM 25 YEAR STORM 10 YEAR STORM 2 YEAR STORM 1 YEAR STORM TOP OF POND BOTTOM OF POND ELEV. 17.50 16.50 SEDIMENT FOREBAY 17.38 17.40 17.43 17.45 17.49 4" SANDY LOAM & SEED (TYP.) SHGWT ELEV.: NOT ENCOUNTERED (>96-INCHES) TH-3 TH-4 NOT TO SCALE SEDIMENT FOREBAY & INFILTRATION BASIN - SECTION A-A1 NOT TO SCALE CRUSHED STONE INFILTRATION TRENCH DETAIL3 DESCRIPTION 100 YEAR STORM 25 YEAR STORM 10 YEAR STORM 2 YEAR STORM 1 YEAR STORM TOP OF BASIN BOTTOM OF BASIN ELEV. 17.50 16.00 16.00 16.00 16.00 16.02 16.77 EXISTING DEPRESSION EXTENSION SEE PLAN 3:1 TOP OF SLOPE 3:1 TOP OF SLOPE BOTTOM OF SLOPE 3:1 3:1 EXTEND CLASS "R-3" RIP-RAP TO TOE OF DOWN STREAM SLOPEFLOW FRONT VIEW SIDE VIEW TOP OF SLOPE SEE PLAN GEOTEXTILE FILTER FABRIC (MIRAFI 140N OR APPROVED EQUAL) GEOTEXTILE FILTER FABRIC (MIRAFI 140N OR APPROVED EQUAL) 15" DEEP RIP-RAP (CLASS R-3; 4" TO 6" NOMINAL DIA.) 6-INCH-WIDE x 36-INCH-DEEP CAST-IN-PLACE CONCRETE WEIR (LENGTH PER PLAN) 6" DEEP RIP-RAP BEDDING (3 4" CRUSHED STONE) BOTTOM OF EXPOSED WEIR 15" DEEP RIP-RAP (CLASS R-3; 4" TO 6" NOMINAL DIA.) 6" DEEP RIP-RAP BEDDING (3 4" CRUSHED STONE) COMPACT NATIVE BACKFILL OR COMMON BORROW TO 92% MODIFIED PROCTOR 18" MIN. 18" MIN. BOTTOM OF CIP CONCRETE WEIR (EMBED MIN. 12-INCHES INTO EMBANKMENT) NOT TO SCALE CONCRETE WEIR DETAIL2 X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X E M WV GV MAP 36, LOT 82.1 N/F KISHOR K. PATEL VOLUME 12505, PAGE 226 (COMMERCIAL USE; ZONE B2) MAP 36, LOT 82.2.1 N/F JOAO SILVA VOLUME 31220, PAGE 309 (RESIDENTIAL USE; ZONE B2) MH WV DREW'S WAY (PRIVATE RIGHT OF WAY ~ 12' WIDTH) 2 STY. ECONOLODGE MOTEL No. 59 MAP 36, LOT 76 N/F DIPTI LLC VOLUME 27426, PAGE 307 (COMMERCIAL USE; ZONE B2) MAP 36, LOT 71 N/F ROSEANN KELLEHER VOLUME 21626, PAGE 104 (RESIDENTIAL USE; ZONE B1) MAP 36, LOT 82.2.2 N/F HUGH VARDAN & JOHN MOYLAN VOLUME 29158, PAGE 71 (RESIDENTIAL USE; ZONE B2) 1 9 3 3 S T A T E H I G H A W Y ~ L O 2 9 7 7 2 2 21 22 21 20 19 18 17 1 6 21 2 0 20 19 19 2 5 24 23 23 23 23 22 21 OHW OHW OHW OHW GM 25 2 4 24 2 3 23 2 2 2 1 22 21 20 19 GV GV DD D D D W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W G G G G G G G G G G G G G G W W W W W W G G W W T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T OHW OHW OHW OHW OHW OHW O H W O H W O H W O H W O H W O H W O H W O H W O H W O H W O H W OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW GM BH HEDGES COLUMN GUY GAS METER ELEC. METER GAS METER CHAIN LINK FENCE AC UNIT AC UNIT 18 17 1 9 1 8 1 8 1 8 19 1 9 1 8 1 9 BIT. PAVED DRIVEWAY O V E R H E A D W I R E S ( T Y P . ) 5/8" WATE R S E R . 2" WATER G G G G G G G G G G G G G G G G G G G GAPPROXIMATE 2" PE GAS MAIN 6 " P E G A S M A I N C O N C . W A L K C O N C . W A L K BIT. PAVED DRIVEWAY LAWN APPROX. 1/2" G A S S E R . UTILITY POLE (TYP.) (DENSE WOODS / BRUSH) EDGE OF PAVEMENT EDGE OF PAVEMENT WOOD FENCE VINYL FENCE G R A N I T E C U R B I N G ( T Y P . ) R O U T E 2 8 - M A I N S T R E E T ( S T A T E H I G H W A Y L A Y O U T 2 9 7 7 & 6 2 3 7 ) 12 ' A P P R O X . T E L E C O M D U C T ( T Y P . ) A P P R O X . 8 " W A T E R M A I N A P P R O X . 1 6 " W A T E R M A I N 2 STY. "RELAX INN" No. 41 METER PIT 2 0 ZO N E B 1 ZO N E B 2 ZONE B1 ZONE B2 D D D D D D D D BLDG. SEWER INV. 15.50 2" - SDR-21 PVC SEWER 15 LF - 4" SCH40 PVC SEWER PIPE S = 0.02 FT/FT (MIN.) PROPOSED 1,000 GALLON ONE COMPARTMENT SEPTIC TANK PUMP CHAMBER (SEE DETAIL) INV IN: 14.67 INV OUT: 16.50 TH-3 & 4 (DRAINAGE) S SMH #1 RIM: 19.00 INV IN: 15.20 (BLDG) INV OUT : 15.10 (TANK) INV OUT: 15.10 (STUB) S S S S S CAP SEWER SERVICE FOR FUTURE CONNECTION INV: 14.0± BACKWATER VALVE (CLEAN-CHECK OR EQUAL) AND CLEANOUT (TYP.) FFE: 19.50 UG E UGE 50 LF - 4" SDR-35 PVC SEWER PIPE S = 0.02 FT/FT (MIN.) FM FM FM FM FM F M EFFLUENT INTAKE CTL-12 INV IN: 22.32 PROPOSED SOIL ABSORPTION SYSTEM (SAS) CONSISTING OF (12) CUR -TECH CTL-12, 4' X 8' UNITS TOTAL BED SIZE: 48' x 12.75' 4" VENT WITH CHARCOAL FILTER (SEE DETAIL) DISTRIBUTION BOX (DBOX DB-5) INV IN: 22.50 INV OUT: 22.33 TH-1 & TH-2 (SEPTIC) INSPECTION PORT 1 8 19 18 1 8 . 5 16 . 5 16 . 5 15 . 5 17.5 18 . 5 1 8 15 . 5 16 . 5 19 18.5 1 9 19 19 18.5 1 8 18 25 16 14 . 5 14 . 5 16 . 5 18 . 5 17 . 5 20 21 22 23 19 18 17.5 16 17 19 20 21 22 19 20 21 22 23 23 24 24 24 1 9 1 8 . 7 5 18 19 PROPOSED 2,500 GALLON TWO COMPARTMENT SEPTIC TANK (SEE DETAIL) INV IN: 15.00 INV OUT: 14.82 8 LF - 4" SDR-35 PVC SEWER PIPE S = 0.01 FT/FT (MIN.) 10 LF - 4" SDR-35 PVC SEWER PIPE S = 0.01 FT/FT (MIN.) SHEET DESIGNED BY:WMLJR DRAWN BY:SEK/SD CHECKED BY:JAC DATE:NOV. 2024 PROJECT NO:19-19v REVISIONS: NO.DATE.DESCRIPTION 1 4/2025 DESIGN REVIEW 2 2/5/2026 PERMIT SET BE C K E R ' S P A C K A G E S T O R E 55 R O U T E 2 8 WE S T Y A R M O U T H , M A S S A C H U S E T T S AP 3 6 , LO T S 7 7 , 7 8 & 7 9 OF 8Q: \ 1 9 - 1 9 A h a r o n i a n & A s s o c i a t e s \ 1 9 - 1 9 v B e c k e r s P a c k a g e S t o r e \ A C A D \ B e c k e r ' s P a c k a g e S t o r e [ W o r k i n g P l a n ] - R 3 . d w g F e b . 2 4 , 2 0 2 6 1 1 : 4 5 a m PRELIMINARY, NOT FOR CONSTRUCTION JC E JC E JO E C A S A L I E N G I N E E R I N G , I n c . Ci v i l ∙ S i t e D e v e l o p m e n t ∙ T r a n s p o r t a t i o n Dr a i n a g e ∙ W e t l a n d s ∙ I S D S ∙ T r a f f i c ∙ F l o o d p l a i n 30 0 P o s t R o a d , W a r w i c k , R I 0 2 8 8 8  0       3 0 0  0       3  3 F A ; W W W . J O E C A S A L I . C O 0 UTILITY PLAN 5 SCALE (FEET) 0 1 INCH = FT 10 20 40 80 20 MA. MAINLAND (NAD 83) DESIGN FLOW CALCULATION: PER SECTION 15.203: SYSTEM SEWAGE FLOW DESIGN CRITERIA PROPOSED RETAIL (LIQUOR STORE): 5,115 SF / 1,000 SF x 50 GPD = 256 GPD, USE 260 GPD MIN. PROPOSED FAMILY DWELLING, MULTIPLE: TOTAL NUMBER OF BEDROOMS = 4 BEDROOMS 4 BEDROOMS x 110 GPD = 440 GPD TOTAL DESIGN FLOW = 260 GPD + 440 GPD = 700 GPD SEPTIC TANKS: PER SECTION 15.224 MULTIPLE COMPARTMENT TANKS: (2) THE FIRST COMPARTMENT SHALL BE SIZED FOR A MINIMUM HYDRAULIC DETENTION TIME OF 48 HOURS BASED ON THE DESIGN FLOW. (3) THE SECOND COMPARTMENT SHALL BE SIZED FOR A MINIMUM HYDRAULIC DETENTION TIME OF 24 HOURS BASED ON THE DESIGN FLOW. RETAIL + MULTIPLE FAMILY DWELLING DESIGN FLOW: 700 GPD 48 HOUR DETENTION TIME: 1,400 GALLONS 24 HOUR DETENTION TIME: 700 GALLONS ·THEREFORE A 2,500 TWO-COMPARTMENT TANK REQUIRED. PERCOLATION TEST DATA HOLE #:DATE:RATE:DEPTH:ELEVATION 1 11/19/2025 2 MIN/IN 60"22.5900 2 11/19/2025 2 MIN/IN 60"22.5900 PERFORMED BY: CHARLOTTE SPEAKMAN WITNESSED BY: BARRY LEWIS, YARMOUTH BOARD OF HEALTH LEACHFIELD DESIGN: DESIGN DATA: DESIGN RATE: <2 MIN/IN CLASS I SOILS EFFLUENT LOADING RATE: 0.74 GPD/SF LEACHING BED: 700 GPD / 0.74 GPD/SF = 946 SF REQUIRED AREA 1 LEACHING BED PROPOSED CONSISTING OF: 2 ROWS OF 6 CUR-TECH GOOD FLOW CTL-12 (4' x 8') UNITS EACH UNIT PROVIDES 10.57 SF/LF OF TREATMENT AREA 6 UNITS x 8 FT/UNIT x 2 ROWS = 96 LF 96 LF x 10.57 = 1,014.72 SF 1,014.72 > 946 SF OK SHEET DESIGNED BY:WMLJR DRAWN BY:SEK/SD CHECKED BY:JAC DATE:NOV. 2024 PROJECT NO:19-19v REVISIONS: NO.DATE.DESCRIPTION 1 4/2025 DESIGN REVIEW 2 2/5/2026 PERMIT SET BE C K E R ' S P A C K A G E S T O R E 55 R O U T E 2 8 WE S T Y A R M O U T H , M A S S A C H U S E T T S AP 3 6 , LO T S 7 7 , 7 8 & 7 9 OF 8Q: \ 1 9 - 1 9 A h a r o n i a n & A s s o c i a t e s \ 1 9 - 1 9 v B e c k e r s P a c k a g e S t o r e \ A C A D \ B e c k e r ' s P a c k a g e S t o r e [ W o r k i n g P l a n ] - R 3 . d w g F e b . 2 4 , 2 0 2 6 1 1 : 4 5 a m PRELIMINARY, NOT FOR CONSTRUCTION JC E JC E JO E C A S A L I E N G I N E E R I N G , I n c . Ci v i l ∙ S i t e D e v e l o p m e n t ∙ T r a n s p o r t a t i o n Dr a i n a g e ∙ W e t l a n d s ∙ I S D S ∙ T r a f f i c ∙ F l o o d p l a i n 30 0 P o s t R o a d , W a r w i c k , R I 0 2 8 8 8  0       3 0 0  0       3  3 F A ; W W W . J O E C A S A L I . C O 0 CIVIL DETAILS I 6 HANDICAPPED $50.00 FINE TOWING ENFORCED REQUIRED CERTIFICATE PARKING VAN NOTE: SIGNS ARE TO CONFORM WITH THE MOST RECENT EDITION OF THE MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES. * VAN ACCESSIBLE SIGNS FOR SPACES ADJACENT TO THE 8' STRIPED ISLE. SIGN NOTES: 1.SIGN POSTS SHALL BE GALVANIZED STEEL U-CHANNEL (3 1/2" WIDE-MIN) AND INSTALLED IN CONFORMANCE TO M.U.T.C.D. AND RHODE ISLAND STANDARD SPECIFICATIONS. 2.POSTS SHALL BE DRIVEN TO A DEPTH OF 4 FEET (MIN). 3.THE EDGE OF THE SIGN SHALL BE 18" FROM THE FACE OF THE CURB. 4.WITHIN SIDEWALK LOCATIONS THE SIGN POST WILL BE INSTALLED WITHIN A 8"X8"X6" SQUARE BOX FORM. 8 " 6" 26" 27 " 5" WHITE 2 " 6" 1 8 " 45° 3' O C STRIPE 4" WHITE 8'8' 20 ' SEE HANDICAP PAVEMENT MARKING DETAIL THIS SHEET PROPOSED HANDICAP PARKING SIGN (TYP.) (SEE DETAIL,THIS SHEET) CONCRETE CURB TRANSITION NOTE: 1.ALL HANDICAP PARKING AND SIGNAGE SHALL BE IN ACCORDANCE WITH THE AMERICANS WITH DISABILITIES ACT AND THE MASSACHUSETTS STATE BUILDING CODE. 6" CONCRETE SLAB (4,000 PSI) WITH HAUNCH, REINFORCED WITH 6 X 6 W 2.1 X W2.1 W.W.F. PITCH 1/4"/FOOT 6" GRAVEL BORROW AA PLAN VIEW SECTION A-A FINISH GRADE CONTROL JOINT (TYP.) 10' 10' EXPANSION RESTRAINT BAG REMOVAL CATCH BASIN GRATE REBAR FOR SILTSACK SILTSACK FLOW FLOW CATCH BASIN GRATE Notes: PLAN VIEW SECTION VIEW 1.INSTALL SILTSACK IN PROPOSED CATCH BASINS. GRATE TO BE PLACED OVER SILTSACK. SILTSACK SHALL BE INSPECTED PERIODICALLY AND AFTER ALL STORM EVENTS AND CLEANING OR REPLACEMENT SHALL BE PERFORMED PROMPTLY AS NEEDED. 2.MAINTAIN UNTIL UPSTREAM AREAS HAVE BEEN PERMANENTLY STABILIZED. 12' 4" CEMENT CONCRETE SIDEWALK 8" GRAVEL BORROW 6x6 W2.1xW2.1 WELDED WIRE FABRIC NOTES: 1.SHALL BE IN ACCORDANCE WITH ALL APPLICABLE TOWN OF YARMOUTH AND MASSACHUSETTS DEPARTMENT OF TRANSPORTATION STANDARD SPECIFICATIONS. 2.EDGE OF SIGN SHALL BE 1'-6" MIN. FROM EDGE OF CURB. 3.INSTALLATION TO BE IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS. NOT TO SCALE SILT SACK SEDIMENT TRAP4 NOT TO SCALE HANDICAP PARKING SIGNS5 NOT TO SCALE HANDICAP PAVEMENT MARKING 6 NOT TO SCALE HANDICAP PARKING STALLS 7 NOT TO SCALE CEMENT CONCRETE SIDEWALK8 NOT TO SCALE REGULATORY SIGN MOUNTING DETAIL9 NOT TO SCALE DUMPSTER PAD DETAIL10 8' CUT AND REMOVE TOP 50% OF BURLAP & WIRE BASKET FROM TOPS AND SIDES OF ROOTBALL 3" BARK MULCH. MULCH SHOULD NOT BE WITHIN 4" OF TREE TRUNK TRUNK FLARE & TOP OF ROOTBALL SHOULD BE AT GRADE REMOVE DEAD AND BROKEN BRANCHES ONLY DO NOT CUT LEADER EXCAVATE SUBSOIL AS REQUIRED TO PLACE ROOTBALL TO PROPER ELEVATION. PLACE ROOTBALL DIRECTLY ON COMPACTED OR UNDISTURBED SUBSOIL. PLANTING BED 2X WIDER (MIN.) THAN ROOTBALL. BACKFILL W/LOAM TREE STABILIZATION (SEE DETAIL) INSTALL TREE PLUMB SECTION INSTALL LONG PRONG UP AGAINST ROOTBALL INSTALL SHORT PRONG HALFWAY BETWEEN TRUNK AND EDGE OF ROOTBALL EDGE OF PLANTING SOIL/TREE PIT TREE STAPLE TREE TRUNK NOTE: CONTRACTOR SHALL USE CAUTION WITH TREE STAPLES SO NOT TO BE DRIVEN INTO SUBGRADE PIPES AND UTILITIES ROOTBALLPLAN NOT TO SCALE TREE PLANTING DETAIL11 SHEET DESIGNED BY:WMLJR DRAWN BY:SEK/SD CHECKED BY:JAC DATE:NOV. 2024 PROJECT NO:19-19v REVISIONS: NO.DATE.DESCRIPTION 1 4/2025 DESIGN REVIEW 2 2/5/2026 PERMIT SET BE C K E R ' S P A C K A G E S T O R E 55 R O U T E 2 8 WE S T Y A R M O U T H , M A S S A C H U S E T T S AP 3 6 , LO T S 7 7 , 7 8 & 7 9 OF 8Q: \ 1 9 - 1 9 A h a r o n i a n & A s s o c i a t e s \ 1 9 - 1 9 v B e c k e r s P a c k a g e S t o r e \ A C A D \ B e c k e r ' s P a c k a g e S t o r e [ W o r k i n g P l a n ] - R 3 . d w g F e b . 2 4 , 2 0 2 6 1 1 : 4 5 a m PRELIMINARY, NOT FOR CONSTRUCTION JC E JC E JO E C A S A L I E N G I N E E R I N G , I n c . Ci v i l ∙ S i t e D e v e l o p m e n t ∙ T r a n s p o r t a t i o n Dr a i n a g e ∙ W e t l a n d s ∙ I S D S ∙ T r a f f i c ∙ F l o o d p l a i n 30 0 P o s t R o a d , W a r w i c k , R I 0 2 8 8 8  0       3 0 0  0       3  3 F A ; W W W . J O E C A S A L I . C O 0 CIVIL DETAILS II 7 1% MINIMUM SLOPE 45° BEND DOWNSPOUT 1' MAX. FINISH GRADE SCREEN DETAIL FASTENER WYE CONNECTION REDUCER FITTING AS REQUIRED COLLECTION PIPE (SIZE PER PLAN) GALVANIZED 1/4 INCH WIRE MESH SCREEN PIPE CAP W/STAINLESS STEEL HOSE CLAMP TO SECURE SCREENFINAL BACKFILL 60" 30" 54" 48" 42" 36" 18" 24" 15" 12" 96" 56" 88" 80" 72" 64" 39" 48" 34" 30" PIPE DIAM.MIN. TRENCH WIDTH 8" 10" 6" 4" 26" 28" 23" 21" RECOMMENDED MINIMUM TRENCH WIDTHS INITIAL BACKFILL HAUNCH BEDDING SUITABLE FOUNDATION HEAVY CONSTRUCTION (75T AXLE LOAD) * 48" 60" 12" 24"54" - 60" 12" - 48" PIPE DIAM. SURFACE LIVE LOADING CONDITION MINIMUM RECOMMENDED COVER BASED ON VEHICLE LOADING CONDITIONS H-25 * VEHICLES IN EXCESS OF 75T MAY REQUIRE ADDITIONAL COVER NOTES: 1. ALL PIPE SYSTEMS SHALL BE INSTALLED IN ACCORDANCE WITH ASTM D2321, "STANDARD PRACTICE FOR UNDERGROUND INSTALLATION OF THERMOPLASTIC PIPE FOR SEWERS AND OTHER GRAVITY FLOW APPLICATIONS", LATEST ADDITION 2. MEASURES SHOULD BE TAKEN TO PREVENT MIGRATION OF NATIVE FINES INTO BACKFILL MATERIAL, WHEN REQUIRED. 3. FOUNDATION: WHERE THE TRENCH BOTTOM IS UNSTABLE, THE CONTRACTOR SHALL EXCAVATE TO A DEPTH REQUIRED BY THE ENGINEER AND REPLACE WITH SUITABLE MATERIAL AS SPECIFIED BY THE ENGINEER. AS AN ALTERNATIVE AND AT THE DISCRETION OF THE DESIGN ENGINEER, THE TRENCH BOTTOM MAY BE STABILIZED USING A GEOTEXTILE MATERIAL. 4. BEDDING: SUITABLE MATERIAL SHALL BE CLASS I, II OR III. THE CONTRACTOR SHALL PROVIDE DOCUMENTATION FOR MATERIAL SPECIFICATION TO ENGINEER. UNLESS OTHERWISE NOTED BY THE ENGINEER, MINIMUM BEDDING THICKNESS SHALL BE 4" (100mm) FOR 4"-24" (100mm-600mm); 6" (150mm) FOR 30"-60" (750mm-900mm). 5. INITIAL BACKFILL: SUITABLE MATERIAL SHALL BE CLASS I, II OR III IN THE PIPE ZONE EXTENDING NOT LESS THAN 6" ABOVE CROWN OF PIPE. THE CONTRACTOR SHALL PROVIDE DOCUMENTATION FOR MATERIAL SPECIFICATION TO ENGINEER. MATERIAL SHALL BE INSTALLED AS REQUIRED IN ASTM D2321, LATEST EDITION. 6. MINIMUM COVER: MINIMUM COVER, H, IN NON-TRAFFIC APPLICATIONS (GRASS OR LANDSCAPE AREAS) IS 12" FROM THE TOP OF PIPE TO GROUND SURFACE. ADDITIONAL COVER MAY BE REQUIRED TO PREVENT FLOTATION. FOR TRAFFIC APPLICATIONS, MINIMUM COVER, H, IS 12" UP TO 48" DIAMETER PIPE AND 24" OF COVER FOR 54"-60" DIAMETER PIPE, MEASURED FROM TOP OF PIPE TO BOTTOM OF FLEXIBLE PAVEMENT OR TO TOP OF RIGID PAVEMENT. MINIMUM RECOMMENDED COVER BASED ON RAILWAY LOADING CONDITIONS ** COVER IS MEASURED FROM TOP OF PIPE TO BOTTOM OF RAILWAY TIE. *** E-80 COVER REQUIREMENTS, ARE ONLY APPLICABLE TO ASTM F 2306 PIPE. MIN. TRENCH WIDTH (SEE TABLE) 4" FOR 12"-24" PIPE 6" FOR 30"-60" PIPE 6" MIN. COVER TO RIGID PAVEMENT, H MIN. COVER TO FLEXIBLE PAVEMENT, H SPRINGLINE NOT TO SCALE 24" NYLOPLAST DRAIN BASIN DETAIL12 NOT TO SCALE NYLOPLAST SOLID COVER DETAIL13 NOT TO SCALE DRAIN PIPE TRENCH INSTALLATION DETAIL15 NOT TO SCALE DOWNSPOUT LEADER CONNECTION DETAIL16 O.D. 2'-0" TYP. 2'-0" MAX TRENCH EXCAVATION 2'-0" TYP. PRECAST REINFORCED CONCRETE MANHOLE BASE FORMED BRICK INVERT CONSTRUCTED WITH BRICK LAID AS STRETCHERS AND ON EDGE TO FUTURE SEWER CONNECTION TO SEPTIC 48" BB 2' 48" FINISH GRADE MANHOLE FRAME & COVER SHALL BE EAST JORDAN IRON WORKS PRODUCT NO. 00211046C02, OR APPROVED EQUAL,WITH THE WORD "SEWER" CAST INTO THE COVER 30" OPENING CEMENT MORTAR BITUMASTIC COATING ON EXTERIOR RUBBER O-RING GASKET OR PREFORMED FLEXIBLE JOINT SEALANT BETWEEN MANHOLE SECTIONS PRECAST CONCRETE MANHOLE RISERS AS REQUIRED NOTES: 1. ALL LIFTING HOLES TO BE PLUGGED IN AND OUT WITH HYDRAULIC CEMENT. 2. ALL JOINTS TO BE HYDRAULICALLY CEMENTED. 3.BACKFILL TO BE SCREENED WITH NO STONES LARGER THAN 2" DIAMETER. KOR-N-SEAL (OR EQUAL) JOINT SLEEVE (TYP.) FORMED BRICK INVERT HIGHEST PIPE SLOPE PRECAST CONCRETE MANHOLE CONE SECTION AS REQUIRED SECTION B-B 3/4-INCH CRUSHED STONE BEDDING SHALL BE PLACED A MINIMUM OF 12" UNDER MANHOLE BASE ADJUST TO GRADE WITH 2 BRICK COURSES MIN., 4 BRICK COURSE MAX WITH 3 8" MORTAR JOINTS. BED FRAME IN FULL 3 8" MIN. MORTAR BED PLASTIC COATED STEEL MANHOLE STEPS 12" ON CENTER NOT TO SCALE TYPICAL SEWER MANHOLE DETAIL18 NOT TO SCALE 1,000 GAL. SEPTIC TANK DETAIL17 NOTES: 1.IF UNSUITABLE MATERIALS ARE ENCOUNTERED AT SUBGRADE ELEVATION, THE CONTRACTOR SHALL NOTIFY THE ENGINEER. THE DEPTH OF UNSUITABLE MATERIAL TO BE REMOVED WILL BE DETERMINED IN THE FIELD. THE CONTRACTOR SHALL REMOVE AND PROPERLY DISPOSE THE UNSUITABLE MATERIALS AND REPLACE WITH SUITABLE MATERIAL APPROVED BY THE ENGINEER. 2.MINIMUM COMPACTION FOR GRAVEL BORROW SUB-BASE AND SUBGRADE: 95% MODIFIED PROCTOR. 12" GRAVEL BORROW, PLACED AND COMPACTED IN TWO, UNIFORM LOOSE LIFTS 1.75" BITUMINOUS CONCRETE SURFACE COURSE (CLASS 9.5) 2.25" BITUMINOUS CONCRETE BASE COURSE (CLASS 12.5) CONTRACTOR SHALL NOTIFY ENGINEER OF ANY UNSUITABLE MATERIAL FOUND DURING EXCAVATION. UNSUITABLE MATERIAL TO BE REMOVED AND DISPOSED TO A DEPTH DETERMINED IN THE FIELD BY THE ENGINEER. ASPHALT TACK COAT COMPACTED SUBGRADE NOT TO SCALE BITUMINOUS CONC. PAVEMENT14 TEMP. BLOCKING 16.24 9.32 14.8215.00 2,500 GAL. TWO COMPARTMENT SEPTIC TANK ELEVATION OVER SEPTIC TANK: 18.00 FROM BUILDING TO 1000 GALLONS PUMP CHAMBER 24" Ø RISER TO GRADE WITH H-20 LOADED FRAME AND COVER (TYP.) PIPES SHALL BE CONNECTED WITH A WATERTIGHT SEALED FLEXIBLE JOINT FASTENED WITH A STAINLESS STEEL RETRACTABLE CLAMP BUILDING SEWER 4" SDR 35 PVC PIPE S = 0.01 FT/FT 3 4 " 1 0 " M I N . PIPES SHALL BE CONNECTED WITH A WATERTIGHT SEALED FLEXIBLE JOINT FASTENED WITH A STAINLESS STEEL RETRACTABLE CLAMP 6 0 " L I Q U I D L E V E L PROPOSED GAS TRAP NOT TO SCALE SEPTIC TANK TYPICAL SECTION19 4 ' M I N . S E P A R A T I O N L E G D E SHEET DESIGNED BY:WMLJR DRAWN BY:SEK/SD CHECKED BY:JAC DATE:NOV. 2024 PROJECT NO:19-19v REVISIONS: NO.DATE.DESCRIPTION 1 4/2025 DESIGN REVIEW 2 2/5/2026 PERMIT SET BE C K E R ' S P A C K A G E S T O R E 55 R O U T E 2 8 WE S T Y A R M O U T H , M A S S A C H U S E T T S AP 3 6 , LO T S 7 7 , 7 8 & 7 9 OF 8Q: \ 1 9 - 1 9 A h a r o n i a n & A s s o c i a t e s \ 1 9 - 1 9 v B e c k e r s P a c k a g e S t o r e \ A C A D \ B e c k e r ' s P a c k a g e S t o r e [ W o r k i n g P l a n ] - R 3 . d w g F e b . 2 4 , 2 0 2 6 1 1 : 4 5 a m PRELIMINARY, NOT FOR CONSTRUCTION JC E JC E JO E C A S A L I E N G I N E E R I N G , I n c . Ci v i l ∙ S i t e D e v e l o p m e n t ∙ T r a n s p o r t a t i o n Dr a i n a g e ∙ W e t l a n d s ∙ I S D S ∙ T r a f f i c ∙ F l o o d p l a i n 30 0 P o s t R o a d , W a r w i c k , R I 0 2 8 8 8  0       3 0 0  0       3  3 F A ; W W W . J O E C A S A L I . C O 0 CIVIL DETAILS III 8 NOTES: 1.IF UNSUITABLE MATERIALS ARE ENCOUNTERED AT SUBGRADE ELEVATION, THE CONTRACTOR SHALL NOTIFY THE ENGINEER. THE DEPTH OF UNSUITABLE MATERIAL TO BE REMOVED WILL BE DETERMINED IN THE FIELD. THE CONTRACTOR SHALL REMOVE AND PROPERLY DISPOSE THE UNSUITABLE MATERIALS AND REPLACE WITH SUITABLE MATERIAL APPROVED BY THE ENGINEER. 2.MINIMUM COMPACTION FOR GRAVEL BORROW SUB-BASE AND SUBGRADE: 95% MODIFIED PROCTOR. 12" GRAVEL BORROW, PLACED AND COMPACTED IN TWO, UNIFORM LOOSE LIFTS 1.75" BITUMINOUS CONCRETE SURFACE COURSE (CLASS 9.5) 2.25" BITUMINOUS CONCRETE BASE COURSE (CLASS 12.5) CONTRACTOR SHALL NOTIFY ENGINEER OF ANY UNSUITABLE MATERIAL FOUND DURING EXCAVATION. UNSUITABLE MATERIAL TO BE REMOVED AND DISPOSED TO A DEPTH DETERMINED IN THE FIELD BY THE ENGINEER. ASPHALT TACK COAT COMPACTED SUBGRADE 6'-0" 1' - 6 " 9" 3 1/2" 5/8"x2 1/4" DOWEL SOCKET 7" NORMAL GUTTER LINE 1/2"Ø x 4" EPOXY COATED DOWEL 10" 6 1/2"1/2" 160 ' - 0 " MAX . R= CIRCULAR CURB 1" NOTES: 1.SHALL BE IN ACCORDANCE WITH ALL APPLICABLE TOWN OF YARMOUTH AND MASSACHUSETTS DEPARTMENT OF TRANSPORTATION STANDARD SPECIFICATIONS. 2.MINIMUM LENGTH OF STRAIGHT OR CIRCULAR FILLER PIECES TO BE 3'-0". 3.EXPOSED SURFACES TO HAVE A SPONGE FLOAT FINISH. 4.CIRCULAR CURB IS REQUIRED ON CURVES WITH RADII OF 160'-0" OR LESS. STRAIGHT CURB TO BE USED ON CURVES OF MORE THAN 160'-0" RADIUS. 5.EXPOSED EDGES TO HAVE A 3/4" CHAMFER. 2 1/4" 6" GUTTER LINE 1'-6" 3'-0" 10 " 7" 1/2" 2 1/4" Ø x DOWEL SOCKET 5/8" 3 1/2" 9" 6 1/2" (SEE NOTE 2) NOTES: 1.SHALL BE IN ACCORDANCE WITH ALL APPLICABLE TOWN OF YARMOUTH AND MASSACHUSETTS DEPARTMENT OF TRANSPORTATION STANDARD SPECIFICATIONS. 2.DRAWING SHOWS TRANSITION CURB FOR ONE DIRECTION, FOR OTHER DIRECTION USED OPPOSITE HAND AND INCLUDE A 1/2" Ø X 4" EPOXY COATED DOWEL. 3.EXPOSED SURFACES TO HAVE A SPONGE FLOAT FINISH. 4.EXPOSED EDGES TO HAVE A 3/4" CHAMFER. 5.LEFT AND RIGHT SECTIONS SHALL BE INSTALLED AS REQUIRED. 10 " 6'-0" 1'-6" GUTTER LINE 6 1/2" 6" 2 1/4" 6" 9" 3 1/2" 5/8" DOWEL Ø x 2 1/4" 1/2" 7" SOCKET (SEE NOTE 2) NOTES: 1.SHALL BE IN ACCORDANCE WITH ALL APPLICABLE TOWN OF YARMOUTH AND MASSACHUSETTS DEPARTMENT OF TRANSPORTATION STANDARD SPECIFICATIONS. 2.DRAWING SHOWS TRANSITION CURB FOR ONE DIRECTION. FOR OTHER DIRECTION USE OPPOSITE HAND AND INCLUDE A 1/2-INCH Ø 4-INCH EPOXY COATED DOWEL. 3.EXPOSED SURFACES TO HAVE A SPONGE FLOAT FINISH. 4.EXPOSED EDGES TO HAVE A 3/4-INCH CHAMFER. LEGEND COLOR BACKGROUND COPY M.U.T.C.D. SIGN NUMBER SIGN DIMENSION WHITE RED R1-1 STOP 24" 24"WIDTH HEIGHT R5-1 30" 30" RED WHITE DO ENTER NOT RED WHITE RED NOT TO SCALE PRECAST CONCRETE CURB20 NOT TO SCALE 3'-0 PRECAST CONCRETE TRANSITION CURB21 NOT TO SCALE 6'-0 PRECAST CONCRETE TRANSITION CURB22 NOT TO SCALE REGULATORY SIGN DETAILS26 NOT TO SCALE PUMP CHAMBER TANK SECTION25 NOT TO SCALE CUR-TECH SYSTEM PROFILE-SECTION B-B28 NOT TO SCALE CUR-TECH CTL-12 TYPICAL SECTION24 24" Ø RISER WITH H-20 LOADED FRAME & COVER 30" Ø RISER WITH H-20 LOADED FRAME & COVER PUMP & HIGH WATER ALARM TO BE PLACED ON SEPARATE ELECTRICAL CIRCUITS 3 ' M I N . S E P A R A T I O N S H G W T 1 8 " M I N . 2" SDR 21 PVC PIPE FROM LIFT TANK 4" SCH-40 FROM DBOX S = LAID FLAT PROPOSED FINISH GRADE OVER LEACH FIELD ELEV. 24.00 INV. IN: 22.50 INV: 22.32 CUR-TECH CTL-12 LEACHING BED (8) 4' X 8' UNITS BED SIZE: 48' X 12.75' TOP OF CHAMBERS ELEV. 22.82 GEOTEXTILE FILTER FABRIC VENT WITH CHARCOAL FILTER 4" VENTILATION MANIFOLD 10 INCHES MIN. CONTRACTOR TO BACKFILL VOIDS BETWEEN ABS INJECTION MOLDED FINS USING ASTM C-33 CONCRETE SAND SHWT: NONE ENCOUNTERED (OWTS TH-1) INSPECTION PORT (TYP.) SEE UTILITY PLAN FOR LOCATIONS INV. OUT: 22.33 PROPOSED 9-OUTLET DISTRIBUTION BOX WITH BAFFLE AND WATERTIGHT RISER FILL MATERIAL PER 310 CMR DEPARTMENT OF ENVIRONMENTAL PROTECTION SEC. 15.255 (3) (SEE NOTE) REMOVE AND DISPOSE ALL TOPSOIL AND SUBSOIL (A AND B HORIZONS) AND ALL FILL MATERIAL FROM SAS FOOTPRINT AND WITHIN A 5-FT PERIMETER AROUND THE SAS FOOTPRINT; REPLACE WITH FILL MATERIAL PER 310 CMR SEC. 15.255 (3) (SEE NOTE) ELEV: 21.65 BOTTOM OF CLT-12 LEGDE: NONE ENCOUNTERED (OWTS TH-1) PLACE 12" MIN., (6" MIN. ON LEDGE) OF CRUSHED STONE, LEVEL AND COMPACT ENTIRE SURFACE. TANK SHALL BE PLACED LEVEL, WELL SEATED, AND UN-DAMAGED. VACUUM TEST OR FILL WITH CLEAN WATER, NOTE DEPTH TO SURFACE, 24HRS NOTE ANY DROP. EFFLUENT DISCHARGE COLD WEATHER DISCHARGE ASSEMBLY 1,000 GAL. ORENCO BIOTUBE PROPAK PUMP PACKAGE 2 COMPARTMENT TANK OSI EFFLUENT PUMP PF100511 24" DIA. PVC RISER & LID 2" HIGH WATER ALARM/OVERRIDE TIMER 9.92 4" SCH 40 PVC INLET TEE ELEVATION OVER TANK: 18.90 MIN. SCH 80 PVC ELECTRICAL CONDUIT 15.92 14.67 14.50 EMERGENCY STORAGE (1 DAY) 11.75 PUMP OFF 11.50PUMP ON VOLUME PER DOSE LEACHFIELD VOLUME 2 ROWS X 48 FT = 96 FT V = πr²L = π(.17)² X 96 = 8.72 FT³ DOSE 60% TO 75% OF LEACHFIELD VOLUME 0.60 X 8.72 = 5.23 FT³ 0.75 X 8.72 = 6.54 FT³ USE 6.0 FT³ 6.0 FT³ X 7.481 GAL/FT³ = 44.88 GALLONS PER DOSE 16.50 PIPE INSULATION (IF NEEDED) PIPES SHALL BE CONNECTED WITH A WATERTIGHT SEALED FLEXIBLE JOINT FASTENED WITH A STAINLESS STEEL RETRACTABLE CLAMP. FROM SEPTIC TANK 4" SCH 40 PVC PIPE 1,000 GALLON SEPTIC TANK INSIDE AREA: 8.5 FT X 4 FT = 34 SF 34 SF X 7.481 GAL/FT³ = 254.35 GAL/FT / 12 IN = 21.20 GAL/IN FORCE MAIN DIMENSIONS: 106 FT X 2 IN DRAIN BACK VOLUME: 2.29 CU. FT = 17.16 GAL HIGH WATER ALARM/ OVERRIDE TIMER SET AT 2" BELOW INVERT IN. EMERGENCY STORAGE CAPACITY OF 1 DAY: 700 GAL/DAY / 21.20 GAL/IN = 33" PUMP ON TO BE SET 33" BELOW HIGH WATER ALARM/OVERRIDE TIMER DRAW DOWN: 44.88 + 17.16 = 62.04 62.04 GALLONS / 21.20 GAL/IN = 2.92" PUMP OFF TO BE SET 3" BELOW PUMP ON CUR-TECH SYSTEM PROFILE NTS PUMP CALCULATIONS NOT TO SCALE 1,000 SF ONE-COMPARTMENT PUMP TANK27 10.42 NOT TO SCALE TRENCH DRAIN DETAIL23