Loading...
HomeMy WebLinkAbout5227 71 Witchwood Rd Site Plan 02.10.26ZONING DISTRICT: R-40 SETBACKS: FRONT = 30' SIDE = 20' REAR = 20' ACCESSORY BUILDING SETBACK: SIDE & REAR = 6' MAXIMUM BUILDING COVERAGE = 25% N DEED REFERENCE: DEED BOOK 28756 PAGE 301 SURVEY PLAN REFERENCE: PLAN BOOK 190 PAGE 79 THIS PLAN IS NOT FOR REGISTRY RECORDING PURPOSES. PROPERTY OWNER AND CONTRACTORS TO VERIFY ALL WATER LINES AND GAS UTILITIES ON PROPERTY. EXISTING SEPTIC SYSTEM LOCATIONS AND n ELEVATIONS TAKEN FROM RECORD PLANS. I AS—BUILTS AND INSPECTION REPORTS. EXISTING COMPONENTS WERE NOT FIELD VERIFIED. CONTRACTOR TO TAKE ALL MEANS NECESSARY TO LOCATE AND VERIFY ALL EXISTING SEPTIC SYSTEM COMPONENT LOCATIONS AND ELEVATIONS PRIOR TO CONSTRUCTION. EXISTING BUILDING SEWER TO BE CHANGED, ONLY IF NECESSARY, TO LOCATION AND ELEVATION SPECIFIED. DESIGN CALCULATIONS FLOW RATE: 3 BEDROOM DWELLING = 330 G/P/D REQUIRED a 1 BEDROOM ADU = 110 G/P/D REQUIRED TOTAL FLOW = 440 G/P/D REQUIRED (110 G/P/D PER BEDROOM x 4 BEDROOMS) NO GARBAGE GRINDER ALLOWED PROPOSED 2 COMPARTMENT SEPTIC TANK: COMPARTMENT 1: 440 G/P/D x 2 = 880 G/P/D REQUIRED COMPARTMENT 2: 440 G/P/D x 1 = 440 G/P/D REQUIRED USE PROPOSED 1500 GALLON 2 COMPARTMENT SEPTIC TANK *1 BEDROOM TO BE REMOVED FROM EXISTING DWELLING AND RE —ALLOCATED TO PROPOSED A.D.U. 0b IADUE No. 37560 _ MICHAEL LADUE, P.L.S. LADUE LAND SURVEYING ULill TOP OF FOUNDATION EL. 25.26' EXISTING DWELLING EL. 24.5' PROPOSED A.D.U. EL. 22.55'+ EXISTING DWELLING EL. 23.45'+ PROPOSED A.D.U. EXISTING SHED (157 S.F.) (REMOVE) IRON ROD FOUND, JASON C SECTION DETAIL - COMPONENTS EL. 24.0't PROPOSED 2 COMPARTMENT SEPTIC TANK EL. 22.25' COVER W/IN 6- OF GRADE PROPOSED 2 COMPARTMENT 1,500 GALLON SEPTIC TANK COVER W/IN 6- OF GRADE INSTALL GAS BAFFLE IN OUTLETS NOT TO SCALE USE ACME—SHOREY STST15MH OF EQUIVALENT EXTEND 4" INLET TEE 10" BELOW FLOW LINE EXTEND 4" OUTLET TEE 14" BELOW FLOW LINE ALL PIPING TO BE 4" SCHEDULE 40 PVC SEPTIC TANK TO BE INSTALLED ON LEVEL, STABLE & COMPACTED BASE. S, R.S. EL. 22.0' ) 1 EXISTING DISTRIBUTION BOXES 0 2 EL. 21.83' EE66)2 USE ACME—SHOREY D83 OR EQUIVALENT PROVIDE 6" MIN. SUMP OR EQUIVALENT D—BOX TO BE INSTALLED ON LEVEL, STABLE & COMPACTED BASE. NOTES 1. ALL PRECAST COMPONENTS TO BE H-10 RATED. ALL COMPONENTS WITH ANY ANTICIPATED VEHICULAR TRAFFIC TO BE H-20 RATED. 2. ELEVATION DATUM IS FROM MASS MAPPER (GIS). 3. MUNICIPAL WATER IS AVAILABLE. 4. ALL CONSTRUCTION TO CONFORM WITH 310 CMR 15.000 AND ALL OTHER APPLICABLE LOCAL, STATE AND FEDERAL CODES AND REGULATIONS. 5. INSTALLER/CONTRACTOR TO REVIEW & VERIFY ALL ELEVATIONS AND DETAILS AND REPORT ANY DISCREPANCIES TO DESIGNER PRIOR TO CONSTRUCTION OR ASSUME ALL RESPONSIBILITY. 6. INSTALLER/CONTRACTOR IS RESPONSIBLE FOR MAINTAINING SAFE WORK AREA, VERIFING ALL UTILITIES AND NOTIFYING DIG SAFE PRIOR TO CONSTRUCTION. 7. ANY CHANGES TO OR DEVIATIONS FROM THIS PLAN MUST BE APPROVED IN WRITING BY J.C. ELLIS DESIGN CO. AND BOARD OF HEALTH. 8. FINISH COVER OVER COMPONENTS IS NOT TO EXCEED 3' PER 310 CMR 15.000. 9. ALL ABANDONED SEPTIC SYSTEM COMPONENTS TO BE PUMPED DRY AND FILLED WITH CLEAN SAND OR REMOVED AND REPLACED WITH CLEAN SAND. 10. ALL COMPONENTS TO BE PROVIDED WITH WATERTIGHT ACCESS PORTS WITHIN 6" OF FINISH GRADE. 11. ALL SEPTIC TANKS, DISTRIBUTION BOXES AND PIPING TO BE INSTALLED WATERTIGHT. DESIGN P.O. BOX 81 NORTH EASTHAM, MA 02651 (508)240-2220 Email: joson®jcellisdesign.com SITE PLAN - PROPOSED A.D.U. SEPTIC SYSTEM MODIFICATION PLAN L.- M v R l .�—