Loading...
HomeMy WebLinkAboutFire Alarm Inspection Certificate Feb 2026(n Outlook Fwd: Fire alarm inspection repairs From Cape Shore lnn < capeshoreinnma@gmail.com> Dale Tue 4/7 /2026 11:18 AM To Oliva, Mike < MOliva@yarmouth.ma.us>; lnkley, Brad < binkley@yarmouth.ma.us>; Renaud, Philip < PRenaud@yarmouth.ma.us > Attention!: This email originates outside of the organization. Do not open attachments or click links unless you are sure this email is from a known sender and you know the content is safe. Call the sender to verify if unsure. Otherwise delete this email. Forwarded message From: Jim Eaton <j aton rm Date: Tue, Apr 7, 2026 at 1 l:13 AM Subject: Fire alarm inspection repairs To: capeshoreinnma < ca p_cshglginruDa1Qg mail.com > Good morning, This message is to confirm that Cape Cod Alarm is scheduled to return to Cape Shore Inn on Friday May lst 2026 to repair the deficiencies noted on the annual inspection report for the fire system. We will also be looking at our schedule to try to find openings prior to that date to get the repairs completed sooner if possible, but May 1st will be our fallback date if we cannot find any other openings in our schedule. lim Eaton Cape Cod Alarm Co., lnc. Service Department Normal Business hours - 9:00 a.m. to 4:30 p.m. - Monday - Friday (This email is checked during normal business hours only) 24 Hout T Days a Week Emergency Service is available upon phone request only. Please call us at 508-398-6316 Thank you, Fire Alarm Systems F INSPEITIOt'I IERT IATE BlJILt]INC II T Cape Shore lnn 793 Main Street (Route 28) South Yarmouth, MA 02664 (508)6e4-7969 Building Contact: Title: Company: Contact: Title: Dilip Kansagra Contact Cape Cod Alarm Marty Crowell lnstaller lnspection Date: Feb 1O, 2026 Tested to NFPA 72 Standards This lnrpection was performed in accordance wth applicable NFPA standards.The subsequent pages of this report provide performance measurements, llsted ranges of a((eptable results, and aomplete documentation of the inspeation. \lJhenever drsrrerancies exrst betweefl aaceptable performance standards and actual test results, notes and/or recommended solutions have been proposed or provided for immediate review and approval. l,) ., ,1/' /./ ti \\ i ,l Z I I I II a tT Building lnformation Cape Shore lnn 793 Main Street (Route 28) South Yarmouth, MA 02664 United States of America lnspection Performed By Cape Cod Alarm 204 0ld Townhouse Road West Yarmouth, MA 02673 United States of America System Control Unit Manuf acturer: FCI-Gamewell Model NumbEn 72-4 zone Software Version: Locationr 1st Floor Front Desk Current Protection: Breaker Monitoring Companvr Cape Iod Alarm Generated by: BuildingReports.com Contact: Dilip Kansagra Phone: (508)594-7969 Fax; Mobile: Email: lnspector: Martv Crowell Phone: (508) 398-63'15 Fax: Mobile: Email; capecodalarm 1 8@gmail.com lnspection Date 02/ 10/2026 lnstall Date; 02l1 0/1 984 Version Date: 02l10/1984 Disconnect Locationl Phone: {508)398-6315 Page 2 of 15 Executive 5ummary IDC Style: B SLC Style: itAC Style: B Disconnect Typel Account *: 560821 Download Date: 02/ 11/2026 EXEEUTIVE SUMMARY Cape Cod Alarm lnspection 5ummary CategorV Control lndicating lnitiating Totals Certification Total ltems 't4.81% 11.1 1t 7 4.O7\ 1(x)1 Serviced 100.00% 100.00x 100.00% 100.001 Page 3 of 15 Executive Summary Passed 100.00% 33.33% 10.00% 25.93% Building: Cape Shore lnn Contact: Dilip Kansa8ra Failed/Other % 0,00% 66.61% 90.00% 74.071 Qtv 4 3 20 27 Qtv 20 27 Qtv Qty 0 2 18 20 4 'l 2 7 4 3 Company: Cape Cod Alarm lnspector: Marty Crowell Cape Cod Alarm Download Date: 02/1 1/2026 tIISEREPANCY REPIIRT Deficiency, lmpairment, and Observation Generated by: BuildingReports.com The Discrepancy Report consolidates each discrepancy listed within the various lesting sections of your lnspection. Discrepancies are listed by Category. and grouped by device type. The description of the problem is provided and where appropriate, code references are listed for your convenience. AnV item that was inspected that is subject to a recall or part of a manufacturer's replacement/upgrade program is included, Building: Cape Shore lnn Items Iisted for Recall or Replacement/Upgrade Deuice TVpe Manufacturer No recalled items found during this inspection. Building: Cape Shore lnn Model Number Date Control Panel: 1 - FCI-Gamewell T2-4 zone Address Referenre NFPA72 18.3.6 Qtv Discrepancies ScanlD Eell A901791 3 Horn/Strobe A90'17909 Location Problem INDICATING 2nd Floor Room 202 Not Connected '1 2nd Floor by Room 205 Damaged/Worn 1 INITIATING 1st Floor Manager's Apartment by stairs Date Expired 1 1st Floor Room 101 0ate Expired 1st Floor Room 102 Date Expired Page 4 of 15 Discrepancy Report Heat Oetector A9017887 A9017880 A9017881 'l NFPA72 Table 14.4.3.2117ll3l NFPA72 TAbIE 14.4.3.2117)l3l NFPA72 Table 14.4.3.? l17ll3l Cape Cod Alarm Download Date: 02/ 11/2026 NFPA72 14.2.2.2.2 ScanlO Location Heat Oete(tor {contrnued) 49017883 1st Floor Room 103 49017885 1st Floor Room 104 A9017900 1st Floor Room 106 A901790'1 1st Floor Room 107 A9017902 'lst Floor Room 108 49017914 2nd Floor Room 201 A901 791 2 2nd Floor Room 202 2nd Floor Room 203 A9017910 2nd Floor Room 204 A90 1 7908 2nd Floor Room 205 A9017907 2nd Floor Room 206 Problem INITIATING (continued) Date Expired Date Expired Date Explred 1 Date Expired Date Expired 1 Date Expired Date Expired Date Expired 1 Date Expired Date Expired Date Expired 1 Address Reference NFPA72 Table 14,4.3.2 (17)(3) N FPA72 Table 14.4.3.2 (17'tl3l NFPA72 Table 14.4.3.2 (17)(3) NFPA72 Table 14.4.3.2l17ll3l NFPA72 Table 14,4.3.2117ll3l NFPA72 Table 14.4.3.2 (17)(3) NFPA72 Table 14.4.3.2117)l3l NFPA72 Table 14.4.3.2111ll3l NFPA72 Table 14.4.3.2 (17)(3) NFPA72 Table 14.4.3.2,117\3\ NFPA72 Table 14.4.3.2 (17N3) NFPA72 Table 14.4.3.2 .17],.3]. NFPA72 Table 14.4.3.2 (17)(3) N FPA72 Table 14,4,3.2 (17)(3) NFPA72 Table 14.4.3.2l.171{.3]. 1 T 1 1 1 1 A9017905 A9017905 A9017904 A9017903 Code References NFPA72 14,2,2.2.2 2nd Floor Room 207 2nd Floor Room 208 2nd Floor Room 209 Date Expired Date Expired 1 oate Expired 1 1 Date Expired 2nd Floor Room 210 Svstem deficiencies shall be corrected. Page 5 of 15 DiscrepancV Report Cape Cod Alarm Download Datet 02/ 11/2026 A901791 1 NFPA72 18.3.5 t{FPA72 Table 14.4.3.2 (17) (3) Terminals, leads, or addressable communication, that provide for monitoring the integritv of the notification appliance connections shall be provided After 15 years from initial installation, replace alldevices or have 2 detectors per 100 laboratory tested. Page 6 of '15 Discrepancv Report Cape Cod Alarm Download Datet O2l 1 1 / 2026 PR[IPIlsEII StITUTItINS REP[IRT Generated by: BuildingReports.rom The Proposed Solution Report provides a solution for each disrrepancy listed on the Discrepancy Report. Provide a check mark where indi(ated to approve repairs listed within the report. ltems listed as T/M are available for repair on a Time and Materials basis. Building: Cape Shore lnn Control Panel: 'l - FCI-Gamewell T2-4 zone ScanlD Location Solution INDICATING Model *Cost Fired Date Bell A9017913 Horn/Strobe 49017909 Heat 0et€ctor 49017887 A9017880 A9017881 A9017883 A901788s A9017900 A9017901 A9017902 A9017914 49017912 A901791 1 A9017910 2nd Floor Room 202 2nd Floor by Room 205 1st Floor Manager's Apartment bV stairs 1st Floor Room 101 1st Floor Room 102 1st Floor Room 1O3 1st Floor Room 104 1st Floor Room 106 1st Floor Room 107 'l st Floor Room 108 2nd Floor Room 201 2nd Floor Room 202 2nd Floor Room 203 2nd Floor Room 204 Remove Replace INITIATING Replace Replace Replace Replace Replace Replace Replace Replace Replace Replace Replace Replace Page 7 of 15 Proposed Solutions Report 601 P4RK (replacement model) 601 601 501 601 601 601 601 601 601 601 601 601 r/ t\4 T/M T/N4 TIM T/M T/M T/M T/M T/IV T/M T/M T/M T/M T/M Cape Cod Alarm Download Oatet 02/ 1 1 / 2026 Sca n lD Location Heat Detector {contlnued) A9O17908 znd Floor Room 205 A9O17907 2nd Floor Room 206 A9O17906 2nd Floor Room 207 A9O17905 2nd Floor Room 208 A9017904 znd Floor Room 209 A9017903 2nd Floor Room 210 5o lution Replace Replace Replace Replace Replace Replace Customer WO/PO *: (none) INITIATING (continued) Model * 60',] 601 601 601 60'l lnternal WO/PO *l (none) Cost Fixed Date T/M T/M rlM T/M T/M T/M Total: T/M Page8ofl5 Proposed Solutions Report Cape Cod Alarm Download Date: O2l 1 1 /2026 INSPEITItIN & TESTING Generated by: BuildingReports.com The lnspettion & Testing section lists all of the items inspected in your building. ltems are grouped by Passed or Failed/0ther Items are listed bv Category. Each item inrludes the services performed, and the time & date at whach testing occurred, Building: Cape Shore lnn Control Panel: 1 - Ff l-Gamewell T2-6 zane Device Type Location Seruice Time Oate Control Battery Battery Battery Control Panel lndicatinB Horn/Strobe lnitiating CO Detector Heat Detector lndicating Bell Horn/Strobe lnitiating Heat Detector Heat Detector Heat Detector Heat Detector Heat Detector PASSED 'lst Floor in AE5 Transmitter 1st Floor in Fire Alarm Control Panel 1st Floor in Fire Alarm Control Panel l st Floor Front Desk 'l st Floor Manager's Apartment by stairs 1st Floor Room 105 FAILED/OTHER 2nd Floor Room 202 2nd Floor bV Room 205 1st Floor Manager's Apartment by stairs 1st Floor Room '10'1 1st Floor Room 102 1st Floor Room 103 1st Floor Room 104 Page 9 of 15 lnspection & Testing Tested Tested Tested Tested Tested Tested Tested Tested Tested Tested Tested Tested Tested Tested 12r45r51 PM 12:54:24 PM 12:51r40 PM 02/10/2026 12:39:05 PM 12:37;28 PM 12:38;32 PM 12:34:40 PM ozl10/2026 0211012026 02/'to/2026 02t10t2026 02/10/2026 02/ 10/ 2026 02/10/2026 02/10/2026 02/10/2025 02110/2026 02/10/2026 02t10/2026 02/10/2026 1;05:30 PM 1:1'1:32 PM 1:19140 PM 1:18:41 PM 1:18:57 PM 1:19:10 PM 1:19:26 PM Cape Cod Alarm Download Datet 02/ 1 1 / 2026 1st Floor bV Room 103 lnitiating (continued) Heat Detector Heat Detector Heat Detector Heat Detector Heat Detector Heat Detector Heat Detector Heat Detector Heat Detector Heat Detector Heat Detector Heat Detector Heat Detector Oeuice TVpe Location 'l st Floor Room 105 1st Floor Room 107 1st Floor Room 108 2nd Floor Room 201 2nd Floor Room 202 znd Floor Room 2o3 2nd Floor Room 204 2nd Floor Room 205 2nd Floor Room 206 2nd Floor Room 2o7 2nd Floor Room 208 2nd Floor Room 209 2nd Floor Room 210 Sen ice FAILED/OTHER {continued) Tested Tested Tested Tested Tested Tested Tested Tested Tested Tested Tested Tested Tested Page 10 of 1 5 lnspection & Testing Time 1:'19:50 PM 1:20:04 PM 1:20r15 PM 1:22:10 PM 1:22:01 PM 1:21r52 PM 1:2142 PM 'l:2'l:33 PM 1:21:23 PM 1:21 12 PM 1:21:0O PM '1r20:44 Pl\4 1:20:33 PM 0ate 0211012026 02110t2026 o211012026 02/10.t2026 0211012026 02/1012026 0211012026 ozl10/2026 0211012026 02110/2026 ozll0lz026 02110t2026 02110t2026 Cape Cod Alarm Download Dale: 02/ 1 1 / 2026 SERVICE SUMMARY Generated by: BuildingReports.com The Service Summary section provides an overview of the services performed in this report. Euilding: Cape Shore lnn DeviteType Service PASSED quantitV Battery CO Detector Control Panel Heat Detector Horn/Strobe Total Bell Heat Detector Horn/Strobe Total Grand Total Tested Tested Tested Tested 3 1 1 1 1 7 Tested Tested Tested Tested FAILED/OTHER Page 11of 15 Service 5ummary 1 18 1 20 27 Cape Cod Alarm Download Dalet O2l 1 1 / 2026 StlUNTI ANII UI5UAI. TESTING Generated by: BuildingReports.com The Sound and Visual Testing section lists various points throughout your building where audible and visual alarm notification devices were tested. Any bar-coded audible and visual devices will appear in the lnspection and Testing section of this report, Items in this section are grouped by Passed or Failed/other. Where specific decibel readings were recorded, they will appear under the ambient and alarm columns. The Voice column indicates whether the Sound Test Point passed the Voice lntelligibility requirements. The 5Tl or 5ound Transmission lndex is shown if recorded, Building: Cape 5hore lnn Audihle/Visuol Applionces Location Comment Ambient PASSED Alarm Synched ScanlD Horn/Strobe 1st Floor bV Room '103 Horn/Strobe 2nd Floor by Room 205 Passed Damaged/Worn FAILED/OTHER Page 12 of I5 Sound and Visual Testing !A9017882 !49017909 [ape Cod Alarm Download Dalet 02 / 1 1 / 2026 BATTERY & POWER SUPPLY TESTING The Battery & Power Supply Testing section details the readings and measurements of batteries and power supplaes used to provide power to the fire alarm and life safetv svstems. ltems are grouped by Passed or Failed/0ther, Building: Cape Shore lnn Battery Tvpe Location Sealed Lead Acid 1st Floor in AES Transmitter Sealed Lead Acid 1st Floor in Fire Alarm Control Panel Sealed Lead Acid 1st Floor in Fire Alarm Control Panel Rated Ah PASSED 7AH 12U 7AH 12U 7AH 12U Page '13 of 1 5 Battery & Power SupPlY Testing 02/10 /2026 02/10 /2026 Rated Volts Pre Test Post Test Min Ah Teste dAh MFG Date 02/10 /2026 Cape Cod Alarm Download Datet OZl 1 1 / 2026 Generated by: BuildingReports.com Control Panel: 1 - FCI-Gamewell -72-h zone INVENTIIRY & WARRANW REPORT Generated by: BuildingReports.com The lnventory & Warrantv Report lists each of the devices and items that are included in your lnspection Report. A complete inventory count by device type and category is provided. ltems installed within the last 90 days, within the last year, and devices installed for two years or more are grouped together for easy reference. Building: Cape Shore lnn Device or TVpe Battery Bell CO Detector Control Panel Heat Detector Horn/Strobe Building: Cape Shore lnn Tvpe Power Patrol Battery System Sengor CO Detector Heat Detector Bell Bell Chemetron Heat Detector Qty Model *Description NEW (UNDER 90 DAYSI 3 FA5-1O75 Sealed Lead Acid IN SERUICE - 5 YEARS TO 1O YEARS Control Panel: 1 - FC|-Gamewell T2-4 zone lnstall Date 02/10/2026 02/10/2019 02110t2020 CategorV Control lndicating lnitiating Control lnitiating lndicating 1 601 1 1224r 1 5601P Hardwire - Rate-of-Rise IN SERVICE - 25 YEARS OR OLDER Page 14 of 15 lnventory & Warranty Report X of lnventorv 11,11% 3.70% 3.701 70.37% 7.41% QuantitV 3 1 1 1 19 2 02/10/2000 02/10/2000 Cape Cod Alarm 18 601 Download Datet 02/ 11/2026 Tvpe FCI-Gamewell Control Panel Wheelork Horn/Strobe QtV Model * Description lN SERVICE - 25 YEARS OR OLDER (continued) 1 72-4 zone Conventional 2 P4RK (replacement model) Page 15 of 15 lnventory & Warranty Report lnstall Oate 02/'lo/ 19a4 02/10/2000 Download Oalet 02/ 11/2026Cape Cod Alarm