HomeMy WebLinkAboutsprinkler system report 2001Y r\)trtfr2{ O-tlto SPRINKLER FIRE PROTECTTVE SERVICE 350 Mlin Street .W. Yrrmouth, MA 02673.(5OE) 775-2400 ffu }a lli.kfl o* Prevenlion Delices Name of Premise Fax(508) 778-9628 Tel # 508-398-6889 Address Owner Address REPORT # REPORT DATE Owner's Section /5 ' ?.{Barbara Roa uth Yarmouth, MA 02664 St. Pius X Tel # 508-398-6889 /.,?1Barbara Road-South Yarmouth, MA 02664 F 17372 ANNUAL TEST & INSPECTION 2.26-c1 SEMI-QRTLY INSPECTION X A. Explain any occupancy hazard changes since the previous inspection None B. Describe ,ire protection modifications since the last inspection None C. Describe any fires since the lasl inspeclion None D. When was the system piping last checked for stoppage, corrosion, or foreign matter? February 3,2000 E. When was the dry piping system lasit checked for proper pitch? February 3,2000 F. Are dry valves adequately protected from freezing? Yes 1.) General A. ls the building occupied? B. Are all systems in service? C. ls there a minimum of 18 in. clearance between the top of the storage and the sprinkler deflector? D. ln areas protected by wet systems, does all of the building appear to be properly heated? E. Does the hand hose on the sprinkler system ap ear to b G. 2" main drain flowed? H. Dry system, low points drained this inspection? l. Alarms tested this inspection? lnspection comments: x x _-__ll_ x x x SPRINKLER SYSTEM REPORT OF TEST & INSPECTION St. Pius X - Life Center F. ls the YES NO N/A x YES NO N/A 2.) Control Valves A. Are all sprinkler system control valves and all other valves in the appropriate open or closed position? B. Are all control vales in the open position and locked, sealed, or equipped with a tamper switch? x x x 3.) Water Supplies A. Was a water flow test of the main drain made at the sprinkler riser? 4.1 Tanks. Pumps. Fire Department Connections A. Are fire pumps, gravity tanks, reservoirs, and pressure tanks in good condition and properly ma intained? B. Are fire department connections in satisfactory condition, couplings free, caps in place, and check valves tight? Are they accessible and visible? 5.) Wet Svstems A. Are cold weather valves (O.S. & Y.) in the appropriate open or closed position? B. Have antifreeze system solutions been tested? C. Were the antifreeze test results satisfactory? x x x x x x x x 5.) Drv Svstems A. ls the dry valve in service? B. Are the air pressure and priming water level in accordance with manufacturer's instructions? C. Has the operation of the air or nitrogen supply been tested? D. Were low points drained during this inspection? E. Did quick opening devices operate satisfactorily? F. Did the dry valve trip properly during the trip pressure test? G. Did the heating equipment in the dry-pipe valve room operate at the time of inspection? x x x 7 ) Soecial Svstems -A Did the deluge or preaction valves operate properly during the last test? B. Did the heat-responsive devices operate properly during testing? C. Did the supervisory devices operate during testing? 8.) Alarms A. Did the water motor and gong test satisfactorilY? B. Did electric alarm test satisfactorily? C. Did supervisory alarm service test satisfactorilY? 9.) Sprinklers' R*re all sprinklers free from corrosion, loading, or obstruction to spray discharge? B. Are sprinklers less than 50 years? C. ls stock of spare sprinklers available? D. Does the exterior condition of the sprinkler system appear to be satisfactorily? E. Are sprinklers of proper temperature ratings for their locations? 10.) Date dry-pipe valve tested (control valve partially open) 'l 1.) Date dry-pipe valve tested (control valve fully open) 12. ) Date quick-opening device tested 13.) Date deluge or preaction valve tested '14.) Review control valve maintenance YES NO N/A 2-3-00 N/A N/A N/A N/A x x x x x x x x x x DRY PIPE OPERATING TEST DELUGE A PRE. ACTION VALVES N Trip Test Table DRY VALVE Control Valve Maintenance Table o.o.o. IF NO. EXPLATN SERIAL NO NO OPERATEO PROPERLY HYORAULIC NO NO N/A MAXIMUM TIME TO OPERATE RELEASE Control Valves Number Type Open Secured Closed sEc ExPlain Abnormal Signs Condition SERIAL NO.MAKE MODELMAKEMOOEL DRELIABLE TIME WATER REACHEO TEST OUILET WATER PRESSURE AIR PRESSURE TRIP POINT AIR PRESSURE TIME TO TRIP THRU TEST CONNECTION PSr MIN SEC YESSECPStPStMIN x3914N/A2165 wlTHOUT Q.O.D. wlTX Q.O.O PNEUMATIC ELECTRICOPERATION YESYESNODETECTING MEDIA SUPERVISEOPIPING SUPERVISEO YESDOES VALVE OPERATE FROM THE MANUAL TRIP ANO/OR REMOIE CONTROL STATtOt{S IS THERE AN ACCESSIBLE FACILITY IN EACH CIRCUIT FOR TESTING DOES EACH CIRCUIT OPERATE SUPERVISION LOSS ALARM DOES EACH CIRCUIT OPERATE VALVE RELEASE MAKE NOYES MOOEL YES NO YES NO MIN II II City Connection PIV NONE Tank Control Valves NONE Pump Control Valves NONE Sectional Control Valves NONE System Control Valves 2 OS&Y YES YES NO YES NONE Other Control Valves NONE Make Model Type Serial # FEBCO 805 DC 89281 Location lnspectors Test Valve Auxiliary Drain Valves 1 NONE BACK LEFT OF LARGE HALL --_T-- Size Backflow Valve 4" Size 15 ) Water Flow Test at Sprinkler Riser Water supply source City? X Tank?Pump? _ Date Size Test Pipe Static Pressure 65 Residual Pressure 60Last Flow Test 2-3-00 RISER z', Current Flow Test 2-26-01 RISER 2',63 60 16.) Heat Responsive Devices Test Method NONE Type of Equip Manufacturer Test Results: Valve No. Valve No. Valve No. Valve No. ment ABCDEFABCDEFA B C DE FA B C DE F ABCDEFABCOEFA B C DE FA B C DE F Valve Valve Valve Valve No. No. No. No. Auxiliary Equipment: No? X Type? _ Location? - Test Result? -17. ) Explain any "No" answers and comments 18. ) Adjustments or conections made during this inspection. NONE 19.) Although these comments are not the result of an engineering review, the following desirable improvements are recommended. NONE lnspectods Name Company Date ROBERT BRODIE A & B CANCO FEBRUARY 26,2OO1 Test Pipe Location 1F-