HomeMy WebLinkAboutSite plan 4.17.2026N /F
VRI DEVELOPMENT & SALES
37 NEPTUNE LANE
SOUTH YARMOUTH, MA 02664
90,
G
_Q -]
0�
s(P���pG
jw� irl
v7
NS�R PNo�N S�Rv 1 �:
E
PI
E�' P PPG' P®s�t0 Rp S Pegs j�
NGos
P9
NoR�N, F20�3 SQ -\0 l�-E
PNO PpE S NEOsj PAN/
�0�"PPOPN�`NGE�®Ro���
R -
m
COBBLEsj/� l
EXISTLIN�
o � � T,O.F .•a
r*' ELEv O
A 0 0
�Rp,SE� ENT
�cA
G
REF ORP�N � ` o
SITE PLAN (EXISTING AND PROPOSED)
10 5 0 10 20 40
1 "=20'
w
� � o
COBBLE WORK
DRI JE
N /F
ANDREW NOLAN
53 NEPTUNE LANE
SOUTH YARMOUTH, MA 02664
BENCHMARK:
CONSTRUCTION NOTES:
CEMENT BOUND
=7.2' NAVD88
1. ELEVATIONS REFER TO NAVD88. CONTACT SHOREFRONT CONSUI IING FOR ADDITIONAL ELEVATION INFORMATION AS
NEEDED.
2. THE SCOPE OF WORK CONSISTS OF RECONSTRUCTING AN EXISTING PERMITTED BULKHEAD IN THE SAME LOCATION AND
HEIGHT. THE EXISTING PERMITTED LANDING WILL BE MOVED APPROXIMIATELY 6 FEET NORTH RE -USING ONE SET OF
PILES AND RELOCATING THE SOUTHERN 2 PILES TO THE NORTH SIDE OF THE LANDING. THE EXISTING BEACH ACCESS
STAIRS ON THE NORTH SIDE WILL BE MOVED TO THE RELOCATED LANDING, AND THE SMALLER LANDING WILL BE
REMOVED. THE TWO 6'X14' FLOATS MATCH THE PERMIT AND WILL REMAIN. THE EXISTING SMALLER FLOAT UNDER THE
RAMP WILL REMAIN AND BECOME PART OF THE PERMIT. TOTAL FLOAT SQUARE FOOTAGE WILL BE 200 SQUARE FEET.
THE EXISTING 5' WIDE GRAVEL BUFFER SHALL BE REMOVED AND REPLACED WITH A 10' WIDE VEGETATED BUFFER. THE
EXISTING LICENSE IS ABOUT TO EXPIRE AND A NEW LICENSE WILL BE OBTAINED.
3. THE EXISTING OUTFALL PIPE SHALL BE RESEALED TO THE NEW BULKHEAD. ANY REPAIRS TO THE PIPE ITSELF SHALL BE
MADE AS NECESSARY.
4. THE RETURNS ON BOTH ENDS OF THE WALL SHALL EXTEND LANDWARD TO MATCH EXISTING.
5. CONSTRUCTION ACCESS SHALL BE FROM THE APPLICANT'S PROPERTY OR FROM A WORKING BARGE. EQUIPMENT SHALL
BE STORED ON THE APPLICANT'S PROPERTY OR THE WORKING BARGE WHEN NOT IN USE. WORKING BARGE TO BE
ANCHORED TO AVOID BOTTOMING OUT DURING PERIODS OF LOW TIDE.
6. THE WORK ACTIVITY SHALL OCCUPY A MINIMUM AREA TO ACCOMPLISH THE INSTALLATION OF THE BULKHEAD.
EQUIPMENT AND MATERIALS HANDLING SHALL BE IN ACCORDANCE WITH THE WORK PROTOCOL SUBMITTED WITH THE
NOTICE OF INTENT, THE RESULTING ORDER OF CONDITIONS AND AS DIRECTED BY THE YARMOUTH CONSERVATION
�s
AUTHORITIES.
7. ALL AREAS DISTURBED DURING CONSTRUCTION SHALL BE RETURNED TO THEIR PRE-CONSTRUCTON CONDITION. ALL
WORK SHALL BE INSPECTED BY SHOREFRONT CONSULTING AND RECEIVE APPROVAL BEFORE REMOVING EQUIPMENT
FROM THE SITE.
8. THE ACCESS ROUTE AND WORK SITE SHALL BE CLEANED AND RESTORED TO RESEMBLE THE PRE -CONSTRUCTION
CONDITIONS.
9. THE CONTRACTOR SHALL OBTAIN A COPY OF THE ORDER OF COND11IONS ISSUED FOR THE PROJECT BY THE YARMOUTH
CONSERVATION COMMISSION PRIOR TO THE START OF ANY WORK.
10. ANY TIMBER USED IN THE WATER SHALL BE LOWER LEVEL CCA PRESSURE TREATED. ALL HARDWARE SHALL BE
GALVANIZED OR STAINLESS STEEL, UNLESS OTHERWISE APPROVED BY OWNER OR SHOREFRONT CONSULTING.
11. ANY DEBRIS OR MATERIAL THAT ENTERS THE WATER DURING CONSTRUCTION SHALL BE REMOVED IMMEDIATELY.
12. REFER TO STRUCTURAL DRAWING ENTITLED "PLAN SHOWING 10' ENGINEERED VINYL BULKHEAD", BY SHOREFRONT
CONSULTING, AND STAMPED BY MARK MCKENZIE, P.E., DATED 12/12/12 FOR BULKHEAD DETAILS. THE CL9900
SHEETING SHALL BE UTILIZED TO REPLACE THE CL9000 MATERIAL WHICH IS NO LONGER AVAILABLE. THE CL9900 HAS
A SECTION MODULUS OF 20 WHERE THE CL9000 HAD A SECTION MODULUS OF 16.4; THEREFORE, THE CL9900 IS A
SUITABLE REPLACEMENT AND SHALL BE USED. THE DESIGN ANCHOR SPACING IS 7 FEET, WHERE 6 FEET SHALL BE
USED. ALL CHANGES ARE MORE CONSERVATIVE THAN THE ORIGINAL DESIGN.
13. THERE SHALL BE 6 INCHES OF CLEARANCE BETWEEN THE GRADE DIRECTLY BEHIND THE BULKHEAD AND THE TOP OF
THE BULKHEAD.
14. REFER TO THE LANDSCAPING PLAN PROVIDED FOR PLANTING SCHEDULE IN VEGETATED BUFFER STRIP.
8-X8`" GREENHEART
2't
ANCHOR WALE RESOURCE AREA TABLE
I" TOTAL LOT SIZE = 10.000+/- SO. FT. DEED). PROPERTY LINES DEPICTED HEREON ARE BASED
(2) 2" X 8" P.T. CAP; ON A FIELD SURVEY BY DOWN CAPE ENGINEERING
W/ h' GALV. BOLTS 3 X 6 BACK WALE AREA WITHIN THE 100' BUFFER AND RIVERFRONT IN AUGUST OF 2025 AND COMPILED FROM PLANS
0 3' O.C. (TYP) PROPOSED SHOREGUARD AREA = 7.972t SQ. FT. ON RECORD RECORDED IN THE BARNSTABLE
)r GALV. LAG BOLTS CL 9900 VINYL SHEETING, AREA WITHIN THE 100'-200' RIVERFRONT AREA = COUNTY REGISTRY OF DEEDS.
992t SQ. FT. WORK AREA LIES WITHIN FLOOD ZONES AE EL.
® 3' O.C. (TYP) (ALTERNATE 20' LONG MINIMUM (
2"x8" I WITH CAP THRU-BOLTS (TYP) PROPOSED 4" 11') AND ZONE AE (EL. 13') PER FIRM PANEL
ND SUBJ T T C T STORM FLOWAGE #588 OF 875, COMMUNITY MAP NUMBER
(2) 2" X 4" P.T. CAP THRU-BOLTS; 2' O.C. (TYP) EXISTING 10,000f SQ. FT.
°° PROPOSED = NO CHANGE 25001 CO588J EFFECTIVE DATE JULY 16, 2014 AS
2"x8" x N SUPPORTS; W/ Ys" GALV. SHOWN ON THE FEMA ON-LINE DATA BASE.
BOLTS 0 3' O.C. (TYP) PROPOSED CHANCE HELICAL
2"x8" SHOREGUARD CL 9900 ANCHORS; 6' SPACING, (TYP) STRUCTURES WITHIN THE 0'-35' BUFFER OF MFIW
SHEETING (TYP) (RIVERFRONT AREA) DATUM FOR ALL ELEVATIONS = NAVD 88
CAP TOP VIEW TOP 6't EXISTING =104t LINEAR FEET OF BULKHEAD MEAN HIGH WATER = 1.1' NAVD88
CAP VIEW
(ALTERNATE) (INCLUDING RETURNS). MEAN LOW WATER = -1.8' NAVD 88
PROPOSED =NO CHANGE
BULKHEAD CAP DETAIL PROPOSEDENCRTEASED TOTHO' ANDTiPLANTEDUPERRTHE THE PROJECT IS NOT WITHIN AN NHESP BOUNDARY
10-FOOTBULKHEAD PLAN VIEW DETAIL AND IS THEREFORE NOT SUBJECT TO MESA REVIEW
LANDSCAPED PLAN. THE GRAVEL IS TO BE REMOVED. THE 35, 50 AND 100-FOOT OFFSETS FROM THE
5 0 1 2 4
5 0 1 2 4 STRUCTURES WITHIN THE 35'-50' BUFFER OF BULKHEAD (RIVERFRONT AND RESOURCE AREAS) IS
COASTAL BEACH SHOWN ON THE THE 200' RIVERFRONT
SCALE: 1"=2' EXISTING = 670f SQ. FT. AREA IS OFF THE PROPLAN.PERTY.
SCALE: 1"=2' NO CHANGE PROPOSED
STRUCTURES WITHIN THE 50'-100' BUFFER OF 100'
RIVERFRONT AREA
EXISTING = 1,240f SQ. FT.
LAND UNDER OCEAN LSCSF 0-1 PROPOSED = NO CHANGE
EXISTING DWELLING �'� TOP OF WALL SHALL BE 7.1' (TO MATCH EXISTING WALL),
RELOCATED STAIRS EXISTING LANDING TO BE MOVED 6'± NORTH MAXIMUM UNBLANCED FILL= 10 FEET
EXISTING NEW PILES; PROPOSED CAP; SEE DETAIL
/ TOP OF RELOCATED WALL SHALL BE
SEE NOTE 2 7.1' (TO MATCH EXISTING WALL), PROPOSED CONT. GREENHEART S0' MI
NIMUM DEVELOP B EMEDMENT MIN
MAXIMUM UNBALANCED FILL= 10' »
8 x8 ANCHOR WALE PROPOSED CONT. P.T.
10.0 GROUND ELEV. 5.6' � I � 10.00 3"x6" BACK WALE EXISTING GRADE
n 2'f I
EXISTING GRADE
_ '� 15'
_� _ 1 DOCK WASHERS
MHw = 1.1 c1'41EXCAVATE TO RELIEVE LOAD AND 1 "0 THREADED EXCAVATE TO
0.0 MLW = - 8' (FORCED FACILITATE INSTALLATION OF TIE BACKS 00 ROD ADAPTER FACILITATE
INSTALLATION
_ OF TIE BACK
EXISTI GRADE, . _.._10Tf LIMIT
I NEW 1 1/2-0 CHANCE HELICAL SCREW ANCHOR
- DF-EX£�%A-Ti3ON - TYPE SS5 1Yz" X 5' WITH 8" & 10" and 12" FLIGHTS
�--- EXISTING GRADE
-10.0 10.00 ®7'-0" O.C. MINIMUM ANCHOR PENETRATION
0+7 .00 0+00.00 PROPOSED SHOREGUARD CL 9900 SHALL BE 20', AND DEVELOP 18 KIPS MINIMUM
VINYL SHEETING, 20 FEET LONG ANCHOR FORCE PER ANCHOR
SECTION A -A (EXISTING AND PROPOSED i 0-FOOT BULKHEAD ELEVATION DETAIL
5 4 5 10 20 2.5 0 2.5 5 10
1"=10' LICE #25-089
SCALE: 1 "=5'
LOCUS MAP
SCALE 1 "=2000'±
1 Cl-`CAin
F1 of 6f,4
ss9cti N OF 44,gSs9c
DANIELA. aN oa DANIEL yc
o OJALA �� A.
CIVIL cn OJALA cn
No.46502 q No.40980
Po SSG I S T ENGl�0"
s s` E,��
SURD
DATE DANIEL A. OJALA, P.E., P.L.S.
NOT FOR STRUCTURAL
MHW MEAN HIGH WATER
MLW MEAN LOW WATER
2 ELEVATION CONTOUR
PROPERTY LINE
SURVEY NOTES:
RECORD OWNER,
NEPTUNE LANE IRREV❑CABLE TRUST
RA❑UL M. CHALIF❑UX, TRUSTEE
190 QUINSIGAM❑ND AVENUE; APT, 107
SHREWBURY, MA 01545
ASSESSORS MAP 24, PARCEL 168
DEED BK, 31416, PG, 290
PERMIT REFERENCES;
1) SE83-677 HOUSE (1986)
2) CDC FOR SE83-677 (1987)
3) SE83-728 HOUSE (1986
4) CDC FOR SE83-728 (1990)
5) SE83-1049 (1990)
6) CDC FOR SE83-1049 (1991)
7) SE83-1226 FOR DOCK, BULKHEAD
AND CULVERT (1993)
8) CDC FOR SE83-1226 (1995)
9) DEP LICENSE 3523 (1993)1
ESTIMATED EXPIRATION DATE IS
FEBRUARY 2027
NO PART OF THIS DRAWING MAY BE USED BY
ANY PARTY WITHOUT THE EXPRESS WRITTEN
CONSENT OF SHOREFRONT CONSULTING AND
DOWN CAPE ENGINEERING, INC.
i
I
2
4/17/26
ADD BUFFER TO 10', PLANT; MOVE STEPS, ADD NEW WALKWAY
MCB
1
2/29/26
REVISE PER NEW CONSERVATION PLAN REQUIREMENTS
MCB
NO.
I DATE
REVISION
BY i
a
SHEET THE
PLAN SHOWING PROPOSED
BULKHEAD RECONSTRUCTION
PROJECT NO,
SC-rC0
sCALE AS SHOWN
E_ 11/26/25 `
NEPTUNE LANE IRREVOCABLE TRUST
HECK MCB
CHECKED
CHECKED BY
RAOUL M. CHALIFOUX, TRUSTEE
49 NEPTUNE LANE SOUTH YARMOUTH MA
DO
DRAWNONO.
CHALIFOUX.DWG
DOWN CAPE ENGINEERING
939 MAIN STREET
YARMOUTHPORT, MA 02675
(508) 362-4541
SHOREFRONT CONSULTING
I
290 CENTER STREET
DENNIS PORT, MA. 02639
(508) 280-804-6
WWW.SHOREFRONTCONSULTING.COM
OF SHMs