5/22/2026 1:44:08 PMA-00
COVER PAGE
17327 HOLLY LANE
SOUTH YARMOUTH MA 02664
RENOVATION AND ADDITION 3.13.26
MO
MRO
PROJECT DESCRIPTION:
THE REARRANGING OF INTERIOR PARTITIONS ON THE GROUND FLOOR TO ELIMINATE THE
FORMER SUNROOM AND INCREASE THE FOOTPRINT TO ADD TO THE LIVING AREA, THE
RELOCATION OF THE KITCHEN AND THE ADDITION OF A NEW SECOND BATHROOM ADJACENT TO
THE EXISTING ONE. TOTAL NUMBER OF BEDROOMS IS TO REMAIN AT 2 PER SEPTIC CAPACITY.
ALL THE WORK SHALL COMPLY WITH 780 CMR 10TH EDITION AND THE LOCAL ZONING
ORDINANCES
27 HOLLY LANE
SOUTH YARMOUTH
MA 02664
PERMIT SET V2 - 3.13.26
2
2
FIRE/CO2 ALARM NOTE:
CARBON MONOXIDE ALARMS AND COMBINATION ALARMS SHALL RECEIVE THEIR PRIMARY POWER
FROM THE BUILDING WIRING WHERE SUCH WIRING IS SERVED FROM A COMMERCIAL SOURCE
AND, WHERE PRIMARY POWER IS INTERRUPTED, SHALL RECEIVE POWER FROM A BATTERY.
WIRING SHALL BE PERMANENT AND WITHOUT A DISCONNECTING SWITCH OTHER THAN THOSE
REQUIRED FOR OVER CURRENT PROTECTION. ALARMS MAY ALSO BE PART OF A LOW VOLTAGE
OR WIRELESS SYSTEM WITH STANDBY POWER FROM MONITORED BATTERIES IN ACCORDANCE
WITH NFPA 72
CONSERVATION NOTE:
THE LIMITED SCOPE OF EXTERIOR WORK SHALL ALLOW FOR NO SOIL TO BE RELOCATED AND NO
NEW FILL TO BE BROUGHT TO THE PROPERTY. GUTTERS WILL BE EXTENDED 5 FEET AND
DOWNSPOUTS WILL REMAIN AS THEY ARE.
AREAS:
EXISTING GROUND FLOOR 1,008 SF
PROPOSED GROUND FLOOR 1,128 SF
Scale
Project number
Date
Drawn by
Checked by
A-01
SITE PLAN FOR REFERENCE
173
3.13.26
MO
DL
EXISTING SETBACK
15 FEET
PROPOSED SETBACK
15.5 FEET
EXISTING SETBACK
20.5 FEET
EXISTING 4" CONCRETE SLAB
OVER GRADE AT SUNROON
(FORMER GARAGE) ADD 2X12
FLOOR JOISTS AT 16" O.C
ABOVE SLAB FOR
CONVERSION INTO LIVING
SPACE. R-30 MIN SPRAY FOAM
INSULATION
EXISTING CRAWLSPACE
Location of combination smoke and carbon monoxide (CO) alarms
listed in accordance with UL 217 and UL 2034.
* NEW SCOPE IN GREEN
NEW 3 1/2" OD STL LALLY WITH LCC
OVER 2'X2'X1' CONCRETE FOOTING
ALIGNED WITH 5X5 POST ABOVE
CARRYING PROPOSED LVL
EXISTING BLOCK FOUNDATION UNDER EXISTING HOUSE TO REMAIN UNCHANGED
32' - 0"
FORMER SUNROOM CONC FOUNDATION
10' - 0"NEW ADDITION CONC FOUNDATION
5' - 0"24' - 0"5' - 0"10' - 0"32' - 0"
42' - 0"5' - 0"24' - 0"EXISTING PARTIAL
BASEMENT
14' - 10"31' - 9"
EXISTING 4X4 WOOD POSTS TO REMAIN. CHECK FOR INTEGRITY
AND REPLACE WHERE/IF NEEDED
NEW 6X6 POST OVER
FOUNDATION WALL TO
SUPPORT END OF LVL
ABOVE
NEW 10" CONCRETE FOUNDATION
WALL WITH 2X2X1 FOOTING 4' - 0"
BELOW VIRGIN GRADE AS REQUIRED
PER MA BUILDING CODE
ACCESS HATCH Scale
Project number
Date
Drawn by
Checked by 1/4" = 1'-0"
A-02
BASEMENT/FOUNDATION PLAN
173
3.13.26
MO
DS
Location of combination smoke and carbon monoxide (CO) alarms listed in accordance with UL 217 and UL 2034.
* NEW SCOPE IN GREEN24' - 0"MASTER BEDROOM #1
BEDROOM #2
DINING AREA
5' - 0"10' - 0"32' - 0"
MASTER
BATHROOM
NEW GUEST
BATHROOM
CLOSETCLOSETCLOSET
47' - 0"24' - 0"11' - 3"12' - 9"31' - 9"
LIVING AREA
KITCHEN AREA
6' - 5"4' - 0"5' - 2"4' - 0"WASHER/
DRYER
3' - 2"DW
EXISTING FIREPLACE 29' - 0"
Scale
Project number
Date
Drawn by
Checked by 1/4" = 1'-0"
A-03
GROUND FLOOR PLAN
173
3.13.26
MO
DS
5' - 0"42' - 6"7:127:127:127:1212' - 3"12' - 3"24' - 6"12' - 3"12' - 3"5' - 0"42' - 6"
47' - 6"24' - 6"EXISTING ASPHALT SHINGLE
ROOF TO REMAIN
PROPOSED
ASPHALT
SHINGLE
ROOF TO
MATCH
EXISTING
NEW SKYLIGHTS, REFER TO
FRAMING DTL FROM MORE INFO
Scale
Project number
Date
Drawn by
Checked by 1/4" = 1'-0"
A-04
ROOF PLAN
173
3.13.26
MO
DS
FIRST FLOOR
0' - 0"
SECOND FLOOR
8' - 6"
TOP OF EXISTING
16' - 2"
FIRST FLOOR
0' - 0"
SECOND FLOOR
8' - 6"
TOP OF EXISTING
16' - 2"
FIRST FLOOR
0' - 0"
SECOND FLOOR
8' - 6"
TOP OF EXISTING
16' - 2"7' - 8"8' - 6"16' - 2"PROPOSED EXISTING
FIRST FLOOR
0' - 0"
SECOND FLOOR
8' - 6"
TOP OF EXISTING
16' - 2"7' - 8"8' - 6"16' - 2"PROPOSED EXISTING
Scale
Project number
Date
Drawn by
Checked byWWW.MORELORTA.COMINFO@MORELORTA.COM 1/8" = 1'-0"4/27/2026 10:30:28 AMA-05
ELEVATIONS
17327 HOLLY LANE
SOUTH YARMOUTH MA 02664
RENOVATION AND ADDITION 3.13.26
MO
MOR
NORTH ELEVATION EAST ELEVATION
SOUTH ELEVATION WEST ELEVATION
5' - 0"42' - 6"7:127:127:127:1212' - 3"12' - 3"24' - 6"12' - 3"12' - 3"5' - 0"42' - 6"
47' - 6"24' - 6"2X10 ROOF RAFTERS AT 16" O.C. MIN-49 IN ALL ROOFS
2X12 WOOD RIDGE
2X6 WOOD COLLAR TIES AT 16" O.C. ROOFS
2X10 RIM JOISTS
Scale
Project number
Date
Drawn by
Checked by 1/4" = 1'-0"
A-07
ROOF PLAN
173
3.13.26
MO
DS
Scale
Project number
Date
Drawn by
Checked byWWW.MORELORTA.COMINFO@MORELORTA.COM
4/27/2026 10:30:33 AMA-09
CONSTRUCTION DETAILS
17327 HOLLY LANE
SOUTH YARMOUTH MA 02664
RENOVATION AND ADDITION 3.13.26
mo
ds
Scale
Project number
Date
Drawn by
Checked byWWW.MORELORTA.COMINFO@MORELORTA.COM
4/27/2026 10:30:35 AMA-10
FRAMING DETAILS
17327 HOLLY LANE
SOUTH YARMOUTH MA 02664
RENOVATION AND ADDITION 3.13.26
Author
Checker
Scale
Project number
Date
Drawn by
Checked byWWW.MORELORTA.COMINFO@MORELORTA.COM
4/27/2026 10:30:36 AMA-11
OUTLINE SPEC
17327 HOLLY LANE
SOUTH YARMOUTH MA 02664
RENOVATION AND ADDITION 3.13.26
MO
MO
OUTLINE SPECIFICATIONS –
1. TYPICAL ROOF CONSTRUCTION
ASTM D3462 ASPHALT SHINGLES MADE FROM GLASS FELT AND SURFACED WITH
MINERAL GRANULES.
15# FELT
2 COURSES BITUTHENE FLASHING AT EAVES
5/8" CDX PLYWOOD
2 X 12’S OR TGI’S CONSTRUCTION @16”O.C.
1 X 3 WOOD FURRlNG
1/2” GYPSUM DRYWALL
SPRAY FOAM INSULATION R-49 MIN
2. TYPICAL FIRST AND SECOND FLOOR CONSTRUCTION
LUXURY VINYL PLANK(LVP)/CERAMIC TLE
3/4" T & G PTS PLYWOOD
CONSTRUCTION ADHESIVE
2 X 12'S or TGl's @ 16"O.C.
1 X 3 WOOD FURRlNG
1/2” GYPSUM DRYWALL
SPRAY FOAM INSULATION R-30 MIN
3. TYPICAL EXTERIOR WALL CONSTRUCTION
0.625” X 10.25” HARDIE PLANK SIDING (FIBER CEMENT)- ARCHITECTURAL , 9” EXPOSE
OR EASTERN CEDAR SHINGLES 4” TO WEATHER FACE
½” EXTERIOR PLYWOOD
2X6'S@ 16"O.C.
SPRAY FOAM INSULATION R-30 MIN
6 MIL POLYETHYLENE VAPOR BARRIER
1/2” GYPSUM DRYWALL
1 X 4 BEADED BOARD AT ALL SOFFITS
ANDERSEN 400 SERIES WITH U-FACTORS OF ≤ 0.22 FOR WINDOWS AND ≤ 0.26 FOR
PATIO DOORS.
4. TYPICAL FOUNDATION WALL CONSTRUCTION
TUFF-N-DRI XTS WATERPROOFING
WARM N' DRY RIGID INSULATION R-10 MIN CONTINUED
STEEL REINFORCED CAST IN PLACE CONCRETE WALL 10"
12”D X 24”W CONCRETE FOOTING 4' - 0" BELOW VIRGIN GRADE AS PER
MASSACHUSETTS BUILDING CODE SECTION
5. TYPICAL BATHROOM AND LAUNDRY ROOM CONSTRUCTION
CERAMIC OR MARBLE TILE
3/8" PLYWOOD UNDLAYMENT
3/4" T & G PTS PLYWOOD
CONSTRUCT/ON ADHESIVE
2X 12'S OR TGl'S@ 16"0.C.
I X 3 WOOD FURRING
1/2" PURPLE DRYWALL BOARD
ACRYLIC LATEX PAINT
CERAMIC TILE ON GLASS MESH MORTAR BOARD
ENERGY STAR BATHROOM CONDENSER
6. TYPICAL INTERIOR WALL CONTRUCTION
2X6’S @16 O.C.
1/2” GYPSUM DRYWALL
ACRYLIC LATEX PAINT
Scale
Project number
Date
Drawn by
Checked byWWW.MORELORTA.COMINFO@MORELORTA.COM
4/27/2026 10:30:37 AMA-12
FEMA ELEVATION INFO
17327 HOLLY LANE
SOUTH YARMOUTH MA 02664
RENOVATION AND ADDITION 3.13.26
MO
MO
NOTE ON ELEVATION:
DUE TO THE PROJECT BEING ON A FLOOD
ZONE THE SCOPE OF THE WORK SHALL
NOT REPRESENT MORE THAN 50% THE
APPRAISED VALUE OF THE HOUSE ALONE
(NOT THE LAND). THIS SO NOT TO TRIGGER
THE SIGNIFICANT IMPROVEMENT CLAUSE
THAT WOULD REQUIRE LIFTING THE HOUSE
TO +3' ABOVE ELEVATION AE 11'.
Scale
Project number
Date
Drawn by
Checked by
A-13
BEAM CALCULATIONS
173
3.13.26
Author
Checker