Loading...
HomeMy WebLinkAboutSystem Record of Inspection and Testing Mar 2024SYSTET RECORD OF INSPECTION ANO TESTING This form is to be @mplo@ by iD sysfen in$€cl*n dnd tesiie @nbacloi' at tr€ ti'Do of a sysr€m t€sL It $all be ,€/mitted to ndify btis fonn as need€d to pavide I n o@ @mrtb an ot &at twtd. lns€,rt l\!A in a unuspd linas. Attdt dditignal sheats, dara, o. carculatblts 4s necEgsary to ptovib a @nplele B@d. Inspectiory'Test Stan Date/TirEe 3t21t24 hsp€ctio.r/Test Completion Date/Time 3121t24 SupplerDehtal Form(s) Attached:YES (yeyno) 1. PROPERTY INFORMATION Nauset Disposal aadress: 61 Gommonweallfi Avenue South Yarmouth, MA 02664 Service Bay Building Name of property repesentative:Bill Vvhelan 774-316-1563 (cell) address: 61 Commonwealth Avenue South Yarmouth, MA 02664 p1,ons. 508-255-1419 ext 320 rax. 2. TESTING AND MONITORING INFORMATION s-,n61. bill@nausetdisposal.com Testiag orgaaization Seaside Alarms, lnc. 4,16r".r. '1265 Route 28 South Yarmouth, MA 02664 phone: 508-394-0599 Fan: 508-760-2830 p-*u;1. staff@seasidealarms.com Centra-Larm, lnc 466,"r.. 994 Candia Road Manchester, NH 03109 phone: 1€00639-4068 Fax: Ac.ootrumbe. 615-7945 phone tine l: cellular Mcans of traosmission. cellular E-mail: Phone line 2: Entity to wl ch alams are rstrarsmitted: 3. DOCUMENTATION Yarmouth Fire Department phone: 508-398-0363 Located at FACP t"lodet numuer ffi-32 on-site location of $e r€qui.€d r€oqd docufiEnts and site4ecific software: ,I. DESCRIPTION OF SYSTET OR SERVICE 4.1 Cotrtrol Unit Y-r1".1ro' NaPco 4.2 Softw8rc .lld Firmtvrr. Firmware revision number:Napco Quickloader 3.3.6 4.3 Systcm Power 4.3.1 Prim8ry (M.in) Powcr Nominal voltage 120 V Location: OvercunEnt protection t]?e:Disconnecting means location Breaker copyridn o 2012 N.tbnc FrB plor.dim Also.i.li€n. Tlii lofln ,!., b. copi.d lbr ilxlvidr.l r!. ous fit! tr r6d.. I ma, id L c.Pit l to. c..nffilid .ds 6 'tdi'h'itr Amps Amps Name of pmperty: Description of property: Monitoring organization: o. 1of4) t SYSTEM RECORD OF INSPECTION AND TESTING (continued) /t. DESCRIPTION OF SYSTEM OR SERVICE (continuecl) 4J.2 Sccondrry Porvcr T}?e:Battery Ircstioo: @ FACP Battery tr?e (if applicable):Gel Cell Calculafed c{paciay of ba(eries to &ive the system In standby mode (houn): 24 5. NOTIFICATIONS MADE PRIOR TO TESTING Mooitoring orgsniz tion Contact: Building m8|agement Coltact: Building occupants Contact: Authority havingjurisdidion Contact: Other, ifrequircd Contact: 6. TESTING RESULTS 6.1 Cortrol Urit rrd Rcht d Equipmctrt ln alarn mode (minutes): 5 Time: Tirtre: Timei Time: Tine: Comments Control unit New 3l?1124 CDs Fuses l rouble Disconnect switches Ground-fault moni lrcal annunciator Remote annunc iators Remote 6.2 SecondarY Powcr on Commenl3 condition Load New Dis tesl lest Remote batteries Visual lnso€ction Functional Tert a z @ @ @ @ Z a a E Z @ a @ @ a @ @ a Z Z a Vi3ual lmpection Functonal Te!t gtr !! tr D !tr tr tr lo 2oIA SYSTEi, RECORD OF INSPECTION AND TESTING (continud) 6. TESTII{G RESULTS Gorrtin,B<r) 63 Ahrm rnd Supcrisory Al.rD ltritirtiry Dwicc Attsch supplementary devic€ test sheets for all initiating devic€s. 6.4 Notilicltiotr Applirrcc! Attach supplerDentary appliance test sheets for all notificrlion sppli&ces. 6.5 htcrfrcc Equipmcrt Attach supplementary interface comporEnt test sheets for all interface compooens- Citcltit lnterlacp / Signoling Line Circtit InterJace / Fire Alarn Conool lnterface 6.6 Slp€rvbitr8 Strtion Monitoriog Deacri Commentg Alarm si Alam restoration Trouble si Trouble restoration rcstoration 6.7 Public Emcrgcncy Alsrm Rcportirg Systcm Descri Commenls Alarm Alam restoration Trouble Trouble restoration restomtlon copyrr,ro2ol2tl.tix|.lFr€Mix|Altodri,dlThirlb.mm.ybscol)i'diorindi!,ttlalu..oltrtlalrr6sl€ltmqrolboo.pi€dlb.co.nmgd{r.doqd3!t!!im N/A Yes No Tlme Z ! a D a tr @ ! Z ! a D Yea No Time tr tr tr tr D tr tr tr o o D ! (p.3of4 SYSTEH RECORD OF lt{SPECTIOI{ AND TESTING (continud) 7. NOTIFICATIONS THAT TESTING IS COUPLETE Mooitoring dgardzrlioo Building mamgern€nt Building occrpaots Authority haYing jurisdicti@ Other, ifrcquired Contac.t: Corf8ct Coolact C@tact: Cotaa: Tinre: Time: Tinrc: Time: Time: 8. SYSTEM RESTORED TO I{ORUAL OPERATIO Date: 3121 n4 Time: '12 PM 9. CERTTFTCAT|Oi{ This slstem as inspected and tEsted accoding to NFPA 72, 2013 editioL ChTter 14. printed name: Steve Roberts pa1s. 3122124 Orgarization:Seaside Alams, lnc.1;11". Technician phq1s. 508-394-0599 Qualifications (.efer to 10.5.3) 10. DEFECTS OR MALFUNCTIONS 1{OT CORRECTEO AT COI{CLUSIOI{ OF SYSTEM INSPECTION, TESTII{G, OR MAI TEI{ANCE Existing heat deteclors reconnecied lo new panel, age unknown heat deteclors in high service bay removed Area protected by sprinkler. Yarmouth Fire Department approved and permited l0,l AcceptlDce by Owtrer or Owner'! Reprcre rtive: Th€ undersigned ac{ept€d the test rcport for the system as specified berein P.inted nanc:Signed: Organ ization:Title: cogy'idte2ol2trdi,dFr!flbctonA..o.'a!oThblbdnnl.ybcc.t,i,dfr|nd/id.slu..ollrug|b.rstlinr'ymlb.cq,i.,dlbrcgfntrd.l..I.6.i.ld'ni,lip 4 of4) Date: Phone Signed: NOTIFICATION APPLIANCE SUPPLEiIENTARY RECORD OF INSPECTION AND TESTING This fom is a supplemo.l1 to the s|r'slen Reco/d d lnspedion aN Testing. It itlldude$ a notifuation applidnce tesl recod. This fom is to bo completed by the system inspgclion aod tesiing cgntraclor dt the time ol the inspgction and/or test. tt sha be Nmitted to .*fr ,no ,i#i"rm!,rinKJoo",i{on *rM. and/or ctear roood. lnspectior/Test Slan Dd€/Time 312't 124 lnspoction/Test Cornpletion Date/Tihe 312',v24 Nusber ofsupplerbentdl Pages Attached: YES Name of pmperty Nauset Disposal r,l.l..*., 61 Commonwealth Avenue South Yarmouth, MA 02664 2. NOTIFICATION APPLIANCE TEST RESULTS T€st Rosultg '10 Horn/Strobes 1 Beacon PASS PASS PASS PASS PASS Crpyng O 2Or2 itltidEt Fts prct .rbn A!!od.tion. IrE tonr m..y !. co*rd f. trdv d uts olrr thJl b. l! .b. lt ,tt y not b. c.d.d lor co.nnlrdd .ab o. dbtinlrbl. (p 1of 2r Locatiory'ldentifiar lnterior Exterior 1. PROPERTY INFORTiATION PASS IN]TIATING DEVICE SUPPLETIENTARY RECORD OF INSPECTION AND TESTING This lom k a supplamant ro tlro Syslem Recod of lnsryction and Tosling. It idLdes an initialng devicg tesl acod. :rhis tonn is to bo co/,,pletad by tt e system inspection aN testing c!,lt,?ctot at the tine of the inspeclion and/or test. tt shatt b pemifted to *,il ,no tff!i"nffi,,:,:#;r::.. "r,,r* and/or cteor Bcotd. tnsp€clioo/Test Stan Date/Time:3121t24 lnsp€ction/Test Completion Date/Time:3n1t24 Number of Supplem€ntal rages ettacleo: YES I. PROPERWINFORTTIATION Name ofprcperty:Nauset Disposal e.ddress: 61 Commonwealth Avenue South Yarmouth, MA 02664 2. INITIATING DEVICE TEST RESULTS Oevice Test Results 7 Pull Stations PASS '1 '1 Heat Detectors PASS 2 Smoke Detectors PASS 'l Sprinkler Flow PASS 1 Sprinkler Low Air PASS 2 Sprinkler Tamper PASS Address Location (p 1of2)