HomeMy WebLinkAboutsprinkler and backflow test 2015.-€rlcElFIFIE SPFIINKLEEI Date: 6/10/20'15 Horace & Jeanne Sylvester 810 Main Street Hingham , MA 02403 Fire Sprinklers & Backflow Protection Service - lnspection - lnstallation - Testing - Maintenance 352 Main Street. West Yarmouth, Ma. 02673 Tel: 50&775-2082 - Fax: 508-77+2860 - info@cancofiresprinkler.com - \./y r/.cancolirespnnkler.com Fire Department's Copy eiErEoFIPE =IPFIN<LEEI C2 Y Re: 2015 Fire Sprinkler lnspection & Test Canco Sprinkler Services recenlly completed the lnspection and Testing of your fire sprinkler system(s) on 6/10/2015 at the Sylvester Residence, 13 8ay Rd. West Yarmouth, MA.. Please find the atlached lnspection and Test Report. Your sprinkler system does contain antifreeze Cfest resulls vrould be shown on the test worksheet) The information about the system's backflow preventer valve is also shown on the test worksheet. lf your lire sprinkler system is tied into a fire alarm system, the llre alarm mmpany that you use is ADT 180G2384653 Your next annual inspection has been tentatively scheduled. We will be contacting you regarding the inspection approximately 30 days prior to the inspection and set up a date and time. Respectf ully submitted, Eric F. Hubler EFH/slp Our lnspector Decastro has dascovered no issues that need(s) attention. < ( serving Cape Cod since 1930 a-ae, FIEIE SPFIINXLEF! Property lnformation & Inspection for: Sylvester Residence 6t10t20't5 Sinole Riser: Anti-Freeze Svstem A ntiFrz Testing Date Propertv: Street: 13 Bav Rd. City: Wesl Yarmouth System Type Sylvester Residence Riser Type Contact Type State:UA. zp ozatz Owner / Designated Representative lnterview lnterview Questions Does Canco have an updated copy of the 'lnspection Aoreement" in the file? Y/N Yes All 'NO" answers require an exolaination ls the entire building occupied at this time?Yes ls the occupancy and the hazard of contents unchanged? Are all fire protection syslems in service, including fire Yes Yes Reference Canco Fie NFPA.25: . A43.1 NFPA-25: A.4.3.1 NFPA.25: A.4.3.'1 NFPA-25: A.4.3.1 NFPA.25: A..t.J. I NFPA-25: 4.1.5 NFPA.25: 4.8.5.2 alarms. and other suooression svstems? Has the sprinkler system remained in service without changes? Yes Was the sprinkler system free of activation of devices or alarms? Yes The building has been unchanged with regards to construction since the last insoection. Yes ls the building free of any hazardous materials?Yes Are you aware that the fire alarms will sound during our testino todav ? Yes Property / Building lnspection Special hazards noticed in the building NA Canco Fire Occupancy of the building is R-3: 1&2 Familv housino Fire department connection is located Post indicator valve is located ln front of the Urildino The sprinkler room is located ln th The fire alarm control panel is loc€ted Electric Bell:No ln fronl of the buil.ii Closest hydrant is located Aarosq lhe qtrppi The outsids alarm equipment consists of lnspecto/s test outlet is located Water l\,lotor Gonq: No h-thebasement Horn / Stobe Lioht No Propenv / Burldinq Questions Has the owner provided ready access to all parts of the sprinkler svstelo? Has the owner provided lighting and ready access to the All "NO" answers require an explaination Reference NFPA.25: 4.1 .2 sprinkler svstem Are all areas of the building with water filled piping at a temgerature of 40 deqrees F or hiaher. Yes NFPA-25: 4.1.2 NFPA.25. 4.1 .1.1 Test Annual Main entrance is located: NA Kevoad bv front door I Y/N Yes lnspector's test outlet is approximately: 5- feet above grade. Yes Property !nformation & !nspection for: Sylvester Residence Sprinkler System lnspection: Sprinklers Y/N All 'NO" answers require an explaination The sprinkler heads show no sign of leakage. Yes Reference NFPA.25 5.2.1 11 The sprinklers are ftee of corrosion, paint, damage & loading Loadino is when heads are coated with dust. orease etc. Yes The sprinklers are installed in the correct orientation. Meaning tie uqrioht heads are urrrioht and Dend?nts head-s faqe dewn. Glass bulb sprinkler heads have liquid in them. Yes Yes NFPA.25 5.2.1.1.1 NFPA.25 5.2.1.1.1 NFPA-25 Stock, fumishings and equipment are not too close to sprinklers llaleisorinklerlheads need clearance of 18" to ooerate orooerlv. The spare head box contains proper number and type of heads. Yes Yes The spare head box contains proper type of sprinkler wrench. Yes Sprinkler System lnspection: Pipe, Fittings, Hangers and Seismic Bracing Piping and fittings are free from mechanical damage, leakage & corrosion. There is nothing resting against or hanging from the piping. Piping, fittings & bracing in concealed spaces such as above susgended ceilinqs shall not require anspection. Ar€as inaccessible due to safety considerations were not i0soeeted. A seheduled shut down oeLds tobe seheduled. Hangers and seismic bracing are not damaged or loose. Loose hanqers and bracinq shall be tiohtened or refastened. Dry, preaction & deluge system gauges show normal air and water pressures. Raserved Yes NFPA,25 5.221 N FPA-25 5-22? NFPA.25 5.223 NFPA-25 5.224 NFPA.25 Yes Yes NA Yes Sprinkler System lnspection: Gauges Wet pipe sprankler system gauges are in good mndition and Yes normal water suoolv oressure is heino maintaine.l NFPA-25 .124,2- NFPA-25 5.2.4A. NFPA-25 5.2.4.4.1 NFPA.25 52442 NFPA.25 NFPA-25 5.2.6 Reserved Sprinkler System lnspection: Waterflow & Supervisory Devices Waterflow and supervisory devices are free of physical damagi. yes This includes watermotor aono. electnc bells. tamDers & low air. Sprinkler System lnspection: Hydraulic Design lnformation Signs The hydraulic design information sign(s) on hydraulically NA desiqned svstems are attached securelv and leaible. Sprinkler System lnspection: Heat Tape The heat tape if any was inspected per manufacture/s NA reouiremgnts. Sprinkler System Antif reeze Your sprinkler svstem does contain antifreeze NFPA-25 5.2.7 5.2.1 .1 .5 NFPA.25: 5.2.1.3 _ NFPA.25: 5.2.1.4 NFPA-25: 5.2.1 .4 NFPA-25 5.241 NA c€rtcctrIH€ EiPEIINI<I-EEI Backflow Type Reduced Pressure Back Flow Prevention Make N4odel Serial Rebuild Order # Rebuild Kit Onsite Wet System Testing Worksheet for: Sylvester Residence Test Date 6/10/15 Size 2" Your sp nkler system does Antifreeze Pipe Size Basement (WED Alarm Check ValveMake Size Year Model SHOTGUN 2-112" Wilkins 975 XL 1369431 containantifreeze Antifreeze SampleS Expansion Tank Size Antifreeze Loop Volume Expansion Tank psi 7-nH is Ncrrtral pressure Year Type | 2015 zuq- ,013]----]Electric Bell Ojgteles NA '!$ sralic f 9s 83 87 l w.M.Gong N"- !!A- Wet System Trip Test Performed From Main Riser Tpst .q nrain lnspectors Test, Low Point & Auxilary Drains # Type Location Valve Tvpe H2O Alarm Time Secs.E Flow Testp.s.i. p.s.i. p.s.i. p.s.i Alarm TestAlarm 7l Supervisory 3 Supervisory 2 Year Year Year Device l L-l 2 Dtreet Side System Side 2 1 2 7 Riser Tvpe #i) E residuat f6s ' 62 65 l - l FACP Al'drm tres- n'es- 2nd llatic f90 8s 8? l-___l noa strobq tN. hA- S"ry'laIgilqIlqylQlq@qlq , Y*- Control Valves CV # CV Location Size TVpe Tums Secured By Time ButBall But-Ball 4