Loading...
HomeMy WebLinkAboutsprinkler inspection 2010Da,^€port o lnspection/Test Annual Sprinkler June 08, 20{ 0 Property Sylvester Residence '. 3 Bay Road West Yarmouth, MA 02673 FIRE SPRI}IKIER SERVICES 152 Main StsEeL West Yamouth- MA 02671 PH: 508-775.2082 - FAX: 508-775-28E0 Conducted by: Paul Cuddy lnspection Ref: 1164 Horace Sylvester (77 4)7 49-881 1 Siqnatures I state that the information on this form is correcl at theandplace of my inspecli this time was left in operational co on. and that allequip ndition ment uponsted at oletion of this insoeclion exceot as noted Water Based System lnspection Yes Gauges on wet pipe system in good condition and showing normal water supply pressure?Yes Alarm devices free from physical damage?NA Hydraulic nameplate, if provided, securely attached to riser and legible?NA Valve supervisory switches indicate movement? Fire Departnent Connection Yes Visible and accessible?Yes Couplings and swivels not damaged and rotate smoothly?Yes Plugs or caps in place and undamaged?Yes Gaskets an place and in good condition?Yes ldentifrcation sign(s) in place?Yes Check valve is not leaking?Yes Automatic drain valve in place and operating properly?NA lnterior free of obstructions (if caps are not in place) ?NA Valve clapper operational over its full range (if caps are not in place) ? 810 Main Street Hingham, MA 02043 ln good condition ? Free of mechanical damage and not leaking ? No external corrosion ? Properly aligned ? No external loads ? Visible pipe hangers and seismic braces not damaged or loose ? Was an obstruction investigation conducted and the system flushed ? (All "NO" answers are to be fully explained.) Copyright 2002-2009 Life Safety tnspeclor, Onsite Software, tnc Pipe Yes Yes Yes Yes Yes Yes No lnspector - Printed Paul Cuddy lnspector - Srgnature Date 6/8/10 1:36 pm llt Owner - Printed Horace Sylvester Owner - Signature ,ilf,N/ Date 6/8/.t 0 l:50 pm lExcept as noted, the burldinq is occuoled w[h the same loccuiancv classiflcation and hazard bf contents as tasilinspection Also, the svstem has rematned tn service lwthout modification ana been free of actuation of ldevices or alarms System On Monitoring Company Nemec's Alarm (508)362-4283 Operator Nemec Alarms Alarm Paneucode Keypad 20002.00 Print 6t14t2010 Page 1 ol 2 Owner/Agent rD System Off 12.05 P*/ c-4 .(eport of !nspection/Test Annual Sprinkler June 08, 2010 Property: Sylvester Residence Owner: FtRE SPRINKLER SERVICES lnspection Ref: 1164 Sprinklers Yes Sprinkler wrench with spare sprinklers?Yes Proper number and type of spare sprinklers?Yes Free of corrosion?Yes Free of obstructions to spray patterns?Yes Free of foreign materials including paint?Yes Free of physical damage?Yes Are all sprinklers in service dated 1920 or later?Yes Fast Response sprinklers rn service for less than 20 years? lf "no" test sample now and every 10 years.NA Standard sprinklers less than 50 years old ? lf no test sample now and every 10 years.NA lf sprinklers have been replaced, were they proper replacements?NA Sprinklers and spray nozzles protectang commercial cooking equipment and ventilating systems replaced except for bulb-type which show no signs of grease buildup? Gauges S-Year Check Yes Guages checked against calibrated guage or replaced ? AntiFreeze System 2 Glycerine Antifreeze type-10 Freezing temp of antifreezeYes Freezing temp correct? Flow Test lnspector's Test Valve Test & Drain Control Valves Yes 10 Yes Yes Yes Valve lnspection List o,.!U'Secured Seal lnspection Maint.Test o,(,)(l lt,o) oo.o g€'d q)oio !o.9 eq) IJJ E aF o o(, o --,) E (! a Es o a, E F Street-Side 2 ok ok NA ok ok 1 System-Side Butterball SuperVised NA ok ok ok ok ok 7 NA ok ok 1 Ok - Passes lnspection S - Serviced on site X - Requires Service NA - Not Applicable Dt System Connection Flowed Outlet Size P.essure (psi)Results comparable to prior testResidStatic 47 System/Location Alarm Reported Time to Alarm Smooth Bore Orifice Signage Easily Accessible rD Test / Drain Static Main Drain 90 Yes92rrl ,o Valve TypeLocation Butterball a,o EoF Supervised 2" or<[ox@fiNA