Loading...
HomeMy WebLinkAboutsprinkler inspection 2008APPROVEDa/'l t oct ,,.'ru[,ihtrlLL,l'ffi Yarmouth Flra & RescLei2082 $'rvw.cr trcofi rcsbiln kler.co m FIRE SPRJNKLER SERVICES 352 Mrin Street.W. Yarmouth. MA 02673.(508) 77 Fire Sprinkler and Backflow Protection Installalion. Testing and Maintenance Fa-\:(508) 775-28E0 SPRINKLER SYSTEM REPORT OF TEST & INSPECTION Name of Premise Address Owner Address 810 MAIN STREET-HINGHAM, MA 02403 FS484 ANNUAL TEST & INSPECTION SEMI-QRTLY INSPECTION x 6-2-08 Owner's Section A. Explain any occupancy hazard changes since the previous inspection NON E DarD B. Describe fire protection moditications since the last inspection REPLACED SPRINKLER HEADS, REPIPED ANTI.FREEZE LOOP& ADDED EXPANSION TANK, C. Describe any fires since the last inspection NON E D. When was the system piping last checked for stoppage, corrosion, or foreign matter? JUNE 2OO8 E. When was the dry piping system last checked for proper pitch? N/A F. Are dry valves adequately protected from freezing? N/A L) General A. ls the building occupied? B. Are all systems in se ice? C. ls there a minimum of l8 in. clearance between the top of the storage and the sprinkler deflector? D. ln areas protected by wet systems, does all of the building appear to be properly heated? E. Does the hand hose on the sprinkle. system appea. to be satisfactory? F. ls the building completely 6prinkled? G. 2" main drain flowed? H. Dry system, low points drained this inspection? l. Alarms tested this inspection? lnspection comments: NO N/A THIS IS A RESIDENTIAL ANTIF REEZE SYSTEM MONITORED BY NAMEC ALARM YES x x x x x X X X COMPANY. THE ANTIFREEZE TESTED TO 48F. SYLVESTER RESIDENCE Tel # _ 13 BAY ROAD, WEST YARMOUTH, MA 02673 JEAN SYLVESTER Tel # 781-7 49-8811 REPORT # REPORT DATE YES NO N/A 2.) Control Valves A. A.e all sprinkler system control valves and all other valves in the appropriate open or closed position? B. Are all control vales in the open position and locked, sealed, or equipped with a tamper switch? 3.) Water Supplies A. Was a water flow test of the main drain made at the sprinkler riser? 4.1 Tanks, Pumps, Fire Department Connections A. Are fire pumps, gravity tanks, reservoirs, and pressure tanks in good condition and properly maintained? B. Are fire department connections in satasfactory condition, couplings free, caps in place, and check valves tight? Are they accessible and visible? 5.)Wet Systems A. Are cold weather valves (O.S. & Y.) in the appropriate open o. closed position? B. Have antifreeze system solutions been tested? C. Were the antifreeze test results satisfactory? 6.) Drv Svstems A. ls the dry valve in se ice? B. Are the air pressure and priming water level in accordance with manufacturer's instructions? C. Has the operation of the air or nitrogen supply been tested? O. Were low points drained during this inspection? E. Did quick opening device6 oporate satisfactorily? F. Oid the dry valve trip properly during the trip pressure test? G. Did the heating equipment in the dry-pipe valve room operate at the time of inspection? x X X X X x x X X x X X X X x 7.) Special Svstems A. Oid the deluge or preaction valves operate properly during the last test? B. Did the heat-responsive devices operate properly during testing? C. Did the supervisory devices operate during testing? 8.) Alarms A. Oid the water motor and gong test satisfactorily? B. Did electric alarm test satisfactorily? C. Did supervisory alarm service test satisfactorily? 9.) Sprinklers A. Are all sprinklers free from corrosion, loading, or obstruction to spray discharge? B. Are sprinklers less than 50 years? C. ls stock of spare sprinklers available? D. Does the exterior condition of the sprinkler system appear to be satisfactorily? E. Are sprinklers of proper temperature ratings for their locations? 10.) Date dry-pipe valve tested (control valve partially open) 1 1.) Oate ary-pipe valve tested (control valvo fully open) 1 2.) Oate quick-opening device tested 13.) Date deluge or preaction valve tested 14.) Review control valve maintenance YES NO N/A N/A N/A N/A N/A YES X x X X x x x x x X X Control Valves Numbel Trip Test Table DRY VALVE Control Valve Maintenance Table o n Secured Closed S Q.O.D. IF NO, EXPLAIN ALARM OPERATED PROPERLY SERIAL NO NO NO NO IF NO, EXPLAITI HYDRAULIC DELUGE & PRE.ACTION VALVES MAXllr!UM TlilE TO OPERATE RELEASE sEc Explain Abnormalns Condition MAKE MODEL SERIAL NO MAKE MOOEL TIME TO TRIP THRU TEST CONNECTION WATER PRESSURE AIR PRESSURE TRIP POINT AIR PRESSURE TIME WATER REACHED TEST OUTLET MIN sEc PSt PSI PSt MIN sEc YES WITHOUT o.o.D. WITH Q.O,D OPERATION PNEUMATIC ELECTRIC PIPING SUPERVISEO YES NO DETECTING MEDIA SUPERVISED YES DOES VALVE OPERATE FRO TI{E IIANUAL IRIP AND/OR RETIOTE CONIROL sTATrOr{S IS THERE ANACCESSIBLE FACILITY IN EACH CIRCUIT FOR TESTING YES NO MAKE MODEL DOES EACH CIRCUIT OPERATE SUPERVISION LOSS ALARM OOES EACH CIRCUIT OPERATE VALVE RELEASE YES NO YES NO MIN City Connection Ptv NON E Tank Control Valves NON E Pump Control Valves NON E Sectional Control Valves NONE System Control Valves 2 BUTTER BALL YES YES NO YES NON E Other Control Valves NONE Make Size Model Location Size Serial # 136943Backflow Valve lnspectors Test Valve Auxiliary Drain Valves TEST & DRAIN AT CONTROL VALVES CONTROL VALVES WILKINS 975X1 2.INCH 1 ORY PIPE OPERATING TEST YES r -f--ft E RPBP %" 15.) Water Flow Test at Sprinkler Riser Water supply source City?x Tank? Date Pump? Size Test Pipe Static Pressure Residual Pressu re UNKNOWN Current Flow Test 6-2-08 RISER 60 Test Method N/A Type of Equipment Manufacturer Test Results: ABCDEFABCDEFA B C DE FA B C DE F ABCDEFABCDEFA B C DE FA B C DE F Auxiliary Equipment: No? _ Type?Location? 17.) Explain any "No" answerc and comments. Test Result? NONE 't8.) Adjustments or corrections made during thi6 inspection. ADDED SYSTEM SIGNS 19.) attnougtr these comments are not the result of an engineering review, the following desirable improvements are recommended. NON E lnspector's Name Company Date PAUL L, CUDDY CANCO FIRE SPRINKLER SERVICES 6-19-08 Test Pipe Location Last Flow Test 1 16.) Heat Responsive Devices Valve No. Valve No. Valve No. Valve No. Valve No. Valve No, Valve No. Valve No.