HomeMy WebLinkAbout26-205 Lussier T5 Site Plan 7-10-26 bwNOTES LEGEND EXISTING CONTOUR X $� EXIST. SPOT ELEV. --[991--- PROPOSED CONTOUR 198.41 PROPOSED SPOT EL. TH1 Y TEST HOLE 2� SLOPE OF GROUND �z UTILITY POLE FIRE HYDRANT WrF_ WT ALL SYMBdLS WAY APPEAR IN DRAWING 2" MANIFOLD 2" PRESSURE LINE BACK TO PUMP _A - ALARM AND CONTROL PANEL TO BE INSTALLED INSIDE BUILDING. ALARM TO BE ON SEPARATE CIRCUIT FROM PUMP (SEE NOTE 15) \ ACCESS COVERS TO YWTHIN a OF FIN. GRADE }� SYSTEM PROFILE 4" SCH40 PERFORATED PVC DOWN TO 1. DATUM IS NAW 88 SAND AT BOTTOM LEACHING FIELD, 2. MUNICIPAL WATER IS (NOT TO SCALE) PROVIDE 4" THREADED COVER AND 4" VENT, PERF. EXISTING CHRISTY G03 CAST IRON ACCESS RUNS ABOVE 2" PROP. WATERTIGHT COVERS TO GRADE PORT H-20 CONSTRUCTION. PROVIDE CHARCOAL FILTER 3. MINIMUM PIPE PITCH TO BE 1/8" PER FOOT ALL SYSTEM COMPONENTS SHALL BE AND INSECT SCREEN MARKED WITH MAGNETIC TAPE OR DRILL LAST HOLE IN EACH r 4. DESIGN LOADING FOR ALL PROPOSED PRECAST UNITS COMPARABLE MEANS FOR FUTURE LOCATION. PROVIDE QUICK DISCONNECT &BALL LATERAL ON TOP TO VENT FEMALE ADAPTOR &THREADED PLUG TO BE AASHO H-19- VALVE FOR PUMP AIR WHILE LATERAL FILLS 2.0"0 THREADED END CONNECTION 1 MINIMUM .75' OF COVER OVER PRECAST L-1 15.6'-16.2'1 2X SLOPE REQUIRED OVER SYSTEM ]\' S 5--16.3CH 40 PVC 5. PIPE JOINTS TO BE MADE WATERTIGHT. 16.1 PRECASTI(Mi° WATERTEST D'BOX , , 15.37' 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH 2'a FOR LEVELNESS ORIFICES _-- _ INV. IN 13.64' NO LOW POINTS INV. 15.2' 310 CMR 15.000 (TITLE 5.) 1O" Y 14" 1flfl0 GAL. H- IO S " PRESSURE LINE `� "~ °$ ° 008° o TEE **EXISTING TEE .L _ _ _ _ce _ __ _ __ _ ° i 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO ' FLOAT 440 GAL.+ SLOPE TD pRAIN BACK TO PC 2" PRESSURE LINE E °------°� °-I BE USED FOR LOT LINE STAKING OR ANY OTHER PURPOSE. SEPTIC TANK 13.6'f* SWITCH ALARM ON RESERVE 2.0" INVERTS LEVEL AT 15.2' SETTINGS: PUMP ON 0.25" WEEP HOLES BOTTOM LEACHING LEVEL AT EL. 14.7' 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC. CHECK VALVE 2" CENTRAL FED MANIFOLD 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED 5" WORKING RANGE 6" PITCH TO DRAIN BACK TO CONNECT ENDS WITHOUT INSPECTION BY BOARD OF HEALTH AND . r, .. s . :.....: MYERS SRM 4 ' `' °pDDDDDD DDDppDp°pDpDpDDDDDDDDDDp°pDDpDp1 5" PUMP CHAMBER- NO LOW SPOTS. 3 0PERMISSION OBTAINED FROM BOARD OF HEALTH. °°°°°°°°°°DD°pp°°°°°°°pD°° SUBMERSIBLE 4/10 HP PUMP o D PUMP OFF 12" SYSTEM (OR EQUAL) 3/4" TO 1 1/2" DOUBLE WASHED STONE lO. CONTRACTOR SHALL BE RESPONSIBLE FOR CALLING ZABEL FILTER DIGSAFE (811) AND VERIFYING THE LOCATION OF ALL /� OUTLET O66QOQDpODODOQOQD�D6OpD�D�O0D0D�D6D60�D00�4000D00000D�� (A1HD0) V411 L1 p°p°p°p°O°O°D°O°D°O°°°p°O°O°ODD°O°p°°°°°ODODD°p°p°ODODOSIDE ELEVATION VIEW UNDERGROUND &OVERHEAD UTILITIES PRIOR TO TEE W/EXTENSION 6" CRUSHED STONE OR MECHANICAL--- 21-0 Dap°nDODgDOD;popg°;° °oDgDgDnpgp6pdD4Dg g°gpgpg000� COMMENCEMENT OF WORK. (SEE NOTE 17) COMPACTION. (15.221 [21) ADJUSTED GROUNDWATER EL. 11.7' 11. ANY UNSUITABLE MATERIAL ENCOUNTERED SHALL BE GROUNDWATER EL. 10.3' REMOVED BENEATH AND 5' AROUND THE PROPOSED I'? _X SLOPE) EXIST. FOUNDATION- SEPTIC TANK 3' WATERTIGHT WATERPROOF PUMP CHAMBER 7' (SEE NOTE 16) BUOYANCY CALLS: *THE INSTALLER SHALL VERIFY THE LOCATIONS OF ALL **INSTALLER SHALL CONFIRM MINIMUM SEPTIC TANK SIZE AT UTILITIES AND ALL BUILDING SEWER OUTLETS AND ELEVATIONS 1000 GALLONS AND ITS SUITABILITY FOR RE -USE. REPLACE PRIOR TO INSTALLING ANY PORTION OF SEPTIC SYSTEM WITH 1500 GALLON SEPTIC TANK APPROPRIATE TO SITE H-10 1000 GAL. PC WEIGHS 8,240 CONDITIONS IF NOT SUITABLE 4.83' x 8.5' x 2.64' X 62.4 - 6,764 LBS UP (OK) INSPECTION PORT 20 30.0' CAP (TYP.) 5.0' i� 2.5' cV 0 ui 71 0 6 N -. LEACHING DETAIL \b VENT (SCALE: 1 "=10') 0 25 5o 75 100 CAPACITY - GPM PUMP CURVE FOR MYERS SRM4 4/10 HP PUMP TOWARD SITE EXCAVATION 2" X 2" X 36" WOOD POGT 8' MAX. C.C. MIRIFI SILT FENCE OR i WOOD STAKE WD. POST PLAN VIEW V0 COIR FIBER WATTLE NTS METHOD FOR JOINING SILT FENCE SECTIONS POSITION END POSTS TO OVERLAP AS SHOWN ABOVE, MAKING CERTAIN THAT FABRIC FOLDS AROUND EACH POST AT LEAST ONE TURN r� NATURAL GRADE DRIVE POSTS TIGHTLY TOGETHER AND SECURE TOPS OF POSTS WITH CHORD OR WIRE TO PREVENT FLOW -THROUGH OF BUILT-UP EXCAVATED TRENCH SEDIMENT AT JOINT. COMPACTED BACKFILL NOTE: 1. EXCAVATE A 6" x 6" TRENCH ALONG SPECIFIED SILT FENCE LINE IMMEDIATELY AFTER CLEARING AND GRUBBING IS COMPLETE AND INSTALL SILT FENCE. 2. UNROLL SILT FENCE ONE SECTION AT A TIME. POSTS SHOULD BE POSITIONED ON DOWNSTREAM SIDE OF FENCE. 3. DRIVE POST INTO GROUND AND LAY THE TOE -IN FABRIC IN BOTTOM OF TRENCH. BACKRLL TRENCH, AND TAMP GROUND AS SHOWN IN DIAGRAM ABOVE. 4. REMOVE SILT AND DEBRIS BEFORE ONE FOOT ACCUMULATION OCCURS AT THE TEST HALE LOGS FENCE LINE. ENGINEER: PHELLYP T. TONIAL, SE #14955 SILT FENCE INSTALLATION WITNESS: BARRY LEWIS 1 " = 1' 0" DATE: 6/17/2026 PERC. RATE = < 5 MIN/INCH CLASS I SOILS ® UNSUITABLE SOIL ELEV. ELEV. 0" 14.45' On 14.45' A LS 1OYR 4/3 16" B LS 1OYR 6/6 38" C1 FS 2.5Y 6/3 108" t, 2 SiL 2.5Y 7 WORK L1 LINE SIU FENCE 2. The proposed sewage disposal system shall meet the applicable Title 5 wetlands setbacks as set forth by the Health Department. 3. A work limit line shall be established with Erosion Controls (Le straw bales, staked filter fabric, bark mulch, silt sacks, products made with rice straw, and other weed -free products or approved by the Commission.) Hay bales are not allowed. It is the applicant's responsibility to implement and maintain appropriate and adequate erosion controls measures throughout the construction process. 4. No work of any kind shall occur on the Resource Area side of the work limit line. This line shall be established prior to any construction or work. 5. All imported fill shall be clean and not contain any foreign debris such as cement, bituminous concrete, rubber, metal, trash, boulders, etc. 6. Debris, including litter, shall be picked up Immediately. Any excess material that is excavated from the job site shall be disposed of at a location approved by the Conservation Administrator or in a covered dumpster. No debris shall be allowed In a Wetland or Waterway. 7. Washing of equipment/tools shall be done OFF --SITE or handled In a manner approved by the Conservation Administrator. 8. No equipment shall be refueled, nor shall fuel be stored within 100 feet of a resource area. 3'� 9. The cesspool is to be pumped dry, the connection broken, and filled 132" ` 3.45' 108" 5.45' with clean sand. 10.Any area that is disturbed during construction shall be revegetated GROUNDWATER ENCOUNTERED Ce➢ 50" EL. 14.45' immediatelPermanent ystab I stabilization shall or as soon rbe carried out as the in season inorder to minimize erosion. DCE #26-205 11171 A Y LS 1. A hard copy of the plan shall be provided to the Conservation 1OYR 4/3 Administrator for review. An electronic copy of the final plan shall be 18" provided to bdirienzo®yormouth.ma.us B LS 10YR 6/6 11.3' 30" 11.95' PERC C1 G-W ADJ. DATA: FS WELL: SDW-252R 5.45' ZONE: A 2.5Y 6/3 ADJ: 1.4' JUNE 2026 GARAGE BATH BEDROOM LIWNG ROOM BEDROOM 1/4-0 HOLE AT 5' O.C. ALTERNATE BETWEEN TOP & BOTTOM OF PIPE. EXACT DIAMETER HOLES SHOULD BE SHOP DRILLED WITH A DRILL PRESS TO ENSURE UNIFORMITY. REMOVE BURRS PRIOR TO PLACING PIPE. LEACHING FACILITY 2.0" 0 SCH-40 PVC LATERAL SNAP -ON SHIELD DRAINAGE SLOTS LEACHING FACILITY. 12. EXISTING LEACHING FACILITY SHALL BE PUMPED AND REMOVED OR PUMPED AND FILLED WITH CLEAN SAND. 13. OWNER'S ENGINEER TO PERFORM INSPECTIONS OF THE ORIFICE SHIELD OS200 FINAL INSTALLATION. MINIMUM OF 24 HOURS NOTICE REQUIRED. ORENCO SYSTEMS INC14. PH. - 348-9843 WETLAND FLAGGED BY BRAD HALL OF BLH OR EQQUAL.UAL. ENVIRONMENTAL CONSULTING. ON 5/29/2026. 15. INSTALLER TO VERIFY THE ELECTRICAL SYSTEM IS SUITABLE FOR PUMP CONNECTION. ELECTRICAL PERMIT REQUIRED. 16. ALL TANKS ARE TO BE INSTALLED WITH WATERTIGHT SLEEVES, BOOTS AND TANKS MUST BE WATERTIGHT. 17. ACCESS FOR ROUTINE MAINTENANCE MUST BE PROVIDED FOR ZABEL FILTER. INSTALLER MUST FOLLOW MANUFACTURER'S SPECIFICATIONS FOR PROPER FILTER INSTALLATION, INSTRUCT OWNER ON MAINTENANCE. 18. 5' REMOVAL OF UNSUITABLE SOIL REQUIRED AROUND PERIMETER OF LEACHING FACILITY, DOWN TO SUITABLE SOIL LAYER. REPLACE WITH CLEAN MED. SAND, TO MEET SPECIFICATIONS OF 310 OAR 15.255(3). ORIFICESHIELD DETAIL 19. PROVIDE 108' OF 40 MIL LINER AT 5' OFF SAS IN NOT TO SCALE AREA SHOWN. TOP AT ELEV. 15.4', BOTTOM AT EL. 12.4't. FEMALE ADAPTOR & THREADED PLUG SCH 40 PVC {j (TYP. BOTH ENDS) E I I I I I I I E I I I E I g E U f E qt ! v I E I E I E R N BEDROOM (4) LATERALS 5' CENTER TO CENTER SEE LAYOUT DETAIL MIRAFI 14ON FABRIC OVER STONE FEMALE ADAPTOR & THREADED PLUG SCH 40 PVC 20. PROPOSED VENT WITH CHARCOAL FILTER AND BUGSCREEN (FINAL PLACEMENT BY CONTRACTOR WITH HOMEOWNER CONSULTATION). 21. 10' OF SEPARATION REQUIRED BETWEEN WATERLINE & SEPTIC SYSTEM COMPONENTS. 22. EXISTING 1000 GAL SEPTIC TANK TO REMAIN. LOCUS MAP SCALE 1"=2000'f ASSESSORS MAP 140 PARCEL 21 LOCUS IS WITHIN FEMA FLOOD ZONE X (AREA OF MINIMAL FLOOD HAZARD) AS SHOWN ON COMMUNITY PANEL #25001 CO578J DATED 7/16/2014 SITE IS NOT WITHIN MASSDEP DESIGNATED NSA SITE IS NOT WITHIN STATE DESIGNATED ZONE 11 VARIANCES REQUESTED: UNDER MAX. FEASIBLE COMPLIANCE 15.405: (1b): REDUCTION IN SETBACK, SAS TO FOUNDATION (20' TO 10.0') (1h): REDUCTION IN THE REQUIRED SEPARATION DISTANCE FROM THE BOTTOM OF THE SAS TO HIGH GROUNDWATER (4' TO 3') VARIANCES REQUESTED: UNDER TOWN OF YARMOUTH SEWAGE DISPOSAL REGULATIONS: (3.7): REDUCTION IN SETBACK, SAS TO WETLAND (100' TO 64.7') SYSTEM DESIGN GARBAGE DISPOSER IS NOT ALLOWED 2"0 SCW40 PVC MANIFOLD 2" To EXISTING 4 BEDROOM DWELLING PUMP PIT DESIGN FLOW: 4 BEDROOMS 0 110 GPI = 440 GPD PITCH 005 Fr/Fr MIN. - USE A 440 GPD DESIGN FLOW N SEPTIC TANK: 440 GPD (2) = 880 I **USE EXISTING 1000 GAL. SEPTIC TANK & 5'00' USE A 1000 GAL. PUMP CHAMBER LLJ En - LEACHING: 440 GPD / (.74) = 595 SF REQUIRED " 20' X 30' = 600 SF OK LEACHING FIELD Eat 600 SF X .74 = 444 GPD OK USE A 20' X 30' PRESSURE DOSED LEACHING FIELD O r ENDS APPROVED DATE BOARD OF HEALTH MA PLAN VIEW TITLE 5 SITE PLAN PIPING DETAIL 38 MARINERS LANE YARMOUTHPORT, MA PREPARED FOR COMPACT BACKFILL KATHERINE LUSSIER EL. 15.37' KITCHEN DINING ROOM BATH BATH BEDROOM cacQ �o o Q0000aQ0000aQopvg000po�00000ao pogo D op aoaa 2" INV. EL. 15.2' a" popoopo°pgcouocappooaoQopaQ00000aopopoabv000apaa000poopp9poo oo°oo°po°p°oa°000goQ610 °DQOQogoao6aac�000navoaot°,000Qo01 °oa°poD°o°oo°op°op°op opo 6" £L. 14.7' 0. D°PDpD o00000o ODp°ODD°DODODOap°pDppDDODppD°p op FAMILY op oopp 0000poo 0o a pD DD ° ROOM 2.0"0SCH40 PVC 8" TOTAL OF .75" - 1.5" STONE ORIFICE SHIELD OS200 WITH 1/4" ORIFICES DOUBLE WASHED ONLY ORENCO SYSTEMS INC DRILLED AT 5' O.C. PH. 1-800-348--9843 ALTERNATING UP AND DOWN OR EQUAL SEE DETAIL CLEAN COMPACTED COARSE SAND FILL DRILL DISTAL END ON TOP. UNDERNEATH LEACHING FIELD EXISTING 1ST Fro PLAN LEACHING FIELD SECTION (NOT TO SCALE) S NOT TO SCALE DATE: JULY 10, 2026 Scale:1 = 20' ssga 0 10 20 30 40 50 FEET A. yG 2 508-362-4541 downcape.cam down cape eagiaeerinbg, INC. civil engineers "7_ �,,_ land surveyors I/) 0 SURVEY: NHO 939 Main Street (Rte 6A) DATE DANIEL A. OJALA, P.E., P.L.S. YARMOUTHPORT MA 02675 DRAFTED BY: PTT CHECKED BY: 26-205 LUSSIER.dwg