Loading...
HomeMy WebLinkAboutSeptic plan markup 5.26.2026LEGEND PROPOSED CONTOUR ® PROPOSED SPOT GRADE --- -- 98 — — EXISTING CONTOUR + 96.52 EXISTING SPOT GRADE —�fV-- EXISTING WATER SERVICE TEST PIT SURVEY REFERENCE: (PL 8K 289, PG 049) +r SUBDIVISION PLAN IN YARMOUTH, MA r BY ELDREDGE SURVEYING CO. DATED APRIL 28, 1974 + s O'Cg DIN GAR ;SR LIV RM FLOOR PLAN r , r + Uj + O' r � r (� ISO -WET r 1 r� r •N r+ A i (WETLANDS FLAGGED 36I BY BRAD HALL (05/20/26) + ISO -WET j2 fr 37 Y1so-WET j3� 75. 7" Z $0.8' W O J 0 �s PR( PROPOSED WORK LIMIT PLACE STRAW WADDLE AT LIMIT 0 STAKE EVERY 5 FT. GRAPHIC SCALE A -A 0 20 40 60 36 ~` 35 ( IN FEET 1 inch = 20fL VARIANCE REQUESTS — MAXIMUM FEASIBLE COMPLIANCE 1) A 4 FT. VARIANCE TO ALLOW PROP. LEACHING TO BE 5 FT. FROM WATER SERV. VS. REQUIRED 10 FT. (LINER PROV.) 2) A 1.0 FT. VARIANCE TO ALLOW PROP. LEACHING TO BE 4FT. BELOW GRADE VS. REQ'D 3 FT. (H20/VENT REQUIRED) 3) A 19.2 FT. VARMCE TO ALLOW PROP. LEACHING TO BE $0.9 FT. FROM ISOLATED WETLAND VS. REO'D 100 FT. LOT 86 125/071 AREA=15, 703t S. F. ti S83 8 � S9 ., 92 sty. I X LOCUS INFORMATION PARCEL ID: M: 125 P: 071 TITLE REF: 8769/031 PLAN REF: 289 049 PROPERTY IS NOT IN ZONE II PROPERTY 1S IN MADEP NIT SENS AREA FLOOD ZONE: PROPERTY NOT IN FLOOD ZONE SEPTIC SYSTEM REPAIR PLAN LOCATED AT: DECK ^ 6 CLINTON DRIVE SCE '004 YARMOUTHPORT, MA PREPARED FOR W EXjSjING - ESTATE OF 3BR 0WELLl a� o EVELYN HAYES 00 MAY 26, 2026 TOF• r�"�' in rn L N G MEYER H 20.4' LARGE MAPLE TREE No.1 140 ��GIS �c TO BE REMOVED T E�� Q0IX �LPr�.O MEYER & SONS, INC. ove exist 1000g) o - 0 5 FT. SOIL REMOVAL 26 P.O. BOX 981 40mN POLY vent As�.a1 EAST SANDWICH, MA. 02537 PH: (508)360-3311 W 3 FAX: (774)413--9468 32 BENCHMARK: meyerandsonstitle5®gmail.com 33 CLINTON DRIVE MAG NAIL SET SHEET 1 OF 2 EL=31.0' NAVD88 ELEV. TOP FOUNDATION: (Existing) EL. - 38.80 F.G.EL: 37.0 NOTE : BRING ALL COVERS TO WITHIN 3" OF FINISH GRADE PLACE MAGNETIC MARKING TAPE OVER ALL COVERS F.G.EL: 37.0 F.G. EL: 36.5 _\ F.Ci.t:L: J,.3U • 10•I TEE'S ARE TO 8E ter @ S= 1% (MIN,) INV. 33.0 mi • 4" SCH 40 PVC INV. 34.15 INV. 32.83 J PROPOSED DB--3 PROP. OUTLET BAFFLE DISTRIBUTION BOX INV: 34.60 INV: 34.40 (H20) PROP. 1,500 GALLON H2O SEPTIC TANK GAS BAFFLE TO BE INSTALLED ON OUTLET TEE AS MANUFACTURED BY TUF-TITE, ZABEL, OR EQUAL NOTES: 1) CONTRACTOR SHALL VERIFY ALL EXISTING PIPE INVERTS PRIOR TO CONSTRUCTION 2) TANK/D-BOX SHALL BE SET LEVEL AND TRUE TO GRADE ON A MECHANICALL COMPACTED SIX INCH CRUSHED STONE BASE, AS SPECIFIED IN 310 CMR 15.221(2) 3) INSTALL INLET & OUTLET TEES AS REQUIRED SOIL LOGS DATE: MAY 20. 2026 SOIL EVALUATOR: DARREN MEYER, RS, CES 1614 WITNESS: BARRY LEWIS. YARMOUTH HEALTH Elev. 34.90 34.07 31.90 27.23 25.74 21.74 TP--1 A LOAMY SAND IOYR 3/2 B LOAMY SAND IOYR 5/8 C 1 MEDIUM SAND 2.5Y 6/4 C 2 SANDY LOAM IOYR 6/6 C 1 MEDIUM SAID 2.5Y 7/4 Depth 0" 10" 36" 92" 110" 158' PERC RATE <2 MIN/(N. (-Cl- HORIZON) NO GROUNDWATER OBSERVED SEPTIC SYSTEM PROFILE • I, Damn M. Meyer, R.S., CSE. hereby certify that I am currently approved by MADEP pursuant to 310 CWR 15.017 to conduct soil emluatlons and that the above ono"Is has been performed by me consistent with the requirements of 310 CMR I5.017. 1 further certify that i hove pawed the Soil Evol. Exam In October, 1999. k. NOTE: TO PREVENT BREAKOUT, THE PROPOSED FINISH GRADE SHALL NOT BE < EL:31.50 FOR A DISTANCE OF 15' AROUND THE PERIMETER OF THE S.A.S. FINISHED GRADE (35.5) 2% MIN SLOPE OVER LEACHING AREA 2" OF 3/8" DOUBLE WASHED STONE OR FILTER FABRIC 4" SCH 40 PVC 2' EFF. DEPTH INV. ELEV.= 30.50 3/4" - 1-1 /2' DOUBLE WASHED aaaE� O Haaa a613106 aaeaa aaaa®asaeaaa IOU 4' 4' 2 X 8.5' 4' EFFECTIVE LENGTH = 25' TOP CONC. ELEV.= 31.50 INV. ELEV.= 30.50 _ BOTTOM EL.=28.50 SEPARATION 6.76 FT. BOTTOM OF TESTHOLE EL: 21.74 GENERAL NOTES: 1. ALL CHANGES TO THIS PLAN MUST BE APPROVED BY THE LOCAL BOARD OF HEALTH AND THE DESIGN ENGINEER. 2. ALL WORK AND MATERIALS SHALL CONFORM TO THE REQUIREMENTS OF THE STATE ENVIRONMENTAL CODE. TITLE V, AND ANY APPLICABLE LOCAL RULES AND REGULATIONS, EXCEPT AS NOTED ON PAGE 1. 3. THE SEWAGE DISPOSAL SYSTEM SHALL NOT BE BACKFiLLED PRIOR TO INSPECTION AND APPROVAL BY THE BOARD OF HEALTH AND THE DESIGN ENGINEER. 4. ANY CONDITIONS ENCOUNTERED DURING CONSTRUCTION DIFFERING FROM THOSE SHOWN HEREON SHALL BE REPORTED TO THE DESIGN ENGINEER BEFORE CONSTRUCTION CONTINUES. 5. ALL ELEVATIONS BASED ON NAVO 88 DATUM. 6. THE DESIGN ENGINEER IS NOT RESPONSIBLE FOR THE FAILURE OF THE CONTRACTOR OR OWNER TO NOTIFY THE LOCAL BOARD OF HEALTH FOR PROPER INSPECTIONS DURING CONSTRUCTION. 7. WATER SUPPLY PROVIDED BY TOWN WATER. APPROXIMATE LOCATION SHOWN, INSTALLER TO VERIFY LOCATION. S. ALL AREAS DISTURBED DURING CONSTRUCTION SHALL BE RESTORED TO A CONDITION AGREED UPON BETWEEN OWNER AND OONTRACTOR. S. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE THE LOCATION OF ALL UNDERGROUND UTILITIES, PRIOR TO BEGINNING CONSTRUCTION. 10. EXISTING TANK/PIT TO BE PUMPED. CRUSHED AND REMOVED PER TITLE 5. 11. 48 HOUR NOTICE FOR ENGINEER CERTIFICATION 12. THIS PLAN IS TO BE USED FOR SEPTIC SYSTEM PURPOSES ONLY AND IS NOT TO BE CONSIDERED A PROPERTY LINE SURVEY 13. NO KNOWN PRIVATE ABUTTING WELLS WITHIN 150' OF PROPOSED LEACHING. 14. ALL PIPING TO BE 4' SCH 40 O 1 /8"/FT (UNLESS SPECIFIED) 15, PLACE 40 ml POLY LINER ALONG AROUND LEACHING/TANK, EL 31.5-27.5 TO PREVENT INFILTRATION TO WATER SERVICE. 16. REMOVE ALL UNSUITABLE SOILS 5 FT. AROUND LEACHING FROM EL 27.23 TO EL. 25.74 'C2" LAYER ONLY AND REPLACE WITH CLEAN MEDIUM SAND PER TITLE 5. 4' 1 5 FT. BREAKOUT ELEV.= 31.50 4' I EFFECTIVE WIDTH = 13' 1 SOIL ABSORPTION SYSIEM „SECTION) (500 GALLON H-20 LEACH CHAMBER) DESIGN CRITERIA "PROPERTY IS NOT W/IN ZONE 11s4 NUMBER OF BEDROOMS: 3 BEDROOM DESIGN, NO PROP INCREASE SOIL TEXTURAL CLASS: CLASS 1 (0.74 GPD/SF) DESIGN PERCOLATION RATE. <2 MIN/IN DAILY FLOW: 110 G.P.O. X 3 BR = 330 G.P.D. GARBAGE GRINDER: NO (not designed for garbage grinder) SEPTIC TANK: 330 gpd x 200% = 660 gpd, USE PROP. 1,500 GAL. SEPTIC TANK LEACHING AREA REQUIRED: (330)/0.74 = 445.94 S.F. USE TWO (2) 500 GALLON H-20 PRECAST LEACH CHAMBERS W/ 4' STONE ON ALL SIDES: 33.5' L x 13' W x 2'D BOTTOM AREA: 25 x 13 = 325 SF SIDE AREA: (25 + 13) x 2 x 2 - 152 SF TOTAL SQUARE FEET PROVIDED - 477 vs. 445.94 REQ'D DESIGN FLOW PROVIDED: 0.74(477 S.F.) = 352.98 G.P.D. vs. 330 G.P.D. req'd PROPOSED SEPTIC SYSTEM UPGRADE PLAN 6 CLINTON DRIVE, YARMOUTHPORT, MA Prepared for: Estate of Evelyn Hayes Design end Site Plan by: SCALE DRAWN DATE MEYER & SONS, INC. N.T.S. DMM 05/26/26 PO Box 9181 E4STSANOWICH, MA02537 REV DATE CHECKED SHEET NO. 508-362•V22 DMM 2 of 2