HomeMy WebLinkAbout447 Rte 28 Dollar General DRC Comments 052416 SIGNED w PlansCIVIL DESIGNGROUP, LLC 21 HIGH STREET, SUITE 207 NORTH ANDOVER, MA 01845 www.cdgengineering.com p: 978-794-5400 f: 978-965-3971 CIVIL DESIGNGROUP, LLC 21 HIGH STREET, SUITE 207 NORTH ANDOVER, MA 01845 www.cdgengineering.com p: 978-794-5400 f: 978-965-3971 6' -0" DO O R 5 26'- 0" 26'-0"26'-0"26'-0"26'-0" 103B 103A 102 2 A02 13 2B A03 3 A02 2A A03 4 A02 1 A03 RECEIVING AREA 103 SALES AREA 102 BREAKROOM 100 OFFICE 101 MEN 104 WOMEN 105 19 1 A06 1 A02100 106a 104 12 13 6A/6B66BBB666BBB A01SIM. DIMENSIONS FROM INTERIOR FACE OF COLUMN. 7 A01 @ OFFICE & BREAKROOM WALLS 11 12 68 ' - 0 " ( S T E E L T O S T E E L M I N I M U M C L E A R D I M E N S I O N M U S T B E M A I N T A I N E D ) 7 7 6 22 ' - 0" 22 ' - 0" 70'- 0" 4 105 20 18 17 16 5 A01 1313 11 107'-5" (MINIMUM CLEAR DIMENSION, MINIMUM DIMESION MUST BE MAINTAINED) 14 15 4 A03 26'-0" 130'-8" 8" 101 13 6A A01 @ TOILET ROOM WALLS 3'-0" 4 A01 7'-6" HOLD 10'-9" 115'-2"15'-6" 19 6 8 2' - 8" 55 ' - 2 " 46'- 1 0" 12 3 20 3'- 3" 10'- 1 " DIMENSION FROM INTERIOR FACE OF COLUMN. 3 A01 76'-0" BEVERAGE ANCHOR BOARD, REFER TO 2/A01 2'-8" 2' - 8 " 8" 7 21 2323 22 22 2222 WALL KEY AA C BD WALL WA L L WALL WA L L 14'-1"9'-2" 10 A 24 29'-7 1/2" 3 A03 2'-6" HOLDDD 21 9'-0"13'-1"1'-0" 2323 25 25 25 25 28 HALLWAY 107 NOTE: SALES AREA MINIMUM DIMENSIONS TO BE MAINTAINED. NOTE: METAL BUILDING COLUMNS SHALL BE STRAIGHT. TAPERED COLUMNS REQUIRE WRITTEN APPROVAL. MAINTAIN INTERIOR CLEARANCE OF 68'-0" BETWEEN FACE OF COLUMNS ON SALES FLOOR. NOTE: IF A UNIQUE WALL ASSEMBLY IS UTILIZED PER LOCAL GOVERNMENT REQUIREMENTS, THE BUILDING FOOTPRINT SHALL GROW OUTWARD TO MAINTAIN THE MINIMUM SALES AREA DIMENSIONS. ADDITIONAL REGISTERS MAY BE REQUIRED IF THE ANNUAL SALES PROJECTION EXCEEDS THE PERFORMANCE OF A STANDARD STORE. COORDINATE THE FINAL LOCATION AND AMOUNT OF THE REGISTERS WITH THE APPROVED FIXTURE PLAN. SEE DESIGN CRITERIA ON SHEET M1 INDICATING MINIMUM BUILDING ENVELOPE U-FACTORS NOTE: THE CLEAR DISTANCE BETWEEN THE BACK OF THE SALES FIXTURE AND THE GYPSUM BOARD SHALL NOT EXCEED 1 1/2". IF GREATER THAN 1 1/2", FURRING STRIPS SHALL BE INSTALLED TO THE FACE OF THE GYPSUM BOARD, TOP OF STRIPS AT 78" A.F.F., PAINT TO MATCH WALL. 23 21 26AA 21 26 21 26 7' - 2 " 21 26 3'-0" MIN.6'-8" 4A 1'-0" 4' - 0" 23 27 6' - 2 " 13'-4 1/2" 8'-8 1/2" 22'-10 1/2" 45 ' - 4 1 / 2 " 44 ' - 5 1 /2" L S 23'- 7 " 8'-8 1/2" 15'-9 1/2" 23'- 7 " -- 00 22222222222222221111111111111111 W 654 B 3 ' C 2 I M N 1 D 1 A3 A SB C T C D00300333B33B333333BBBB3333B3B31000000000110000001 Y WW N 4 YAYYAA EE 5 EE 510555 HHH AA 0000 HHHH AAAA 000 HHHHH 0 0 WAL 0 0 NMENEEWOWW SPEAKERER TO SIT INIINI TRAY A06 4 '-4 -2 21 262 8 EL S 6' 0 " 2' 67 8888 ALLALL11BUNDLE ANDLE AAA WIRES AND ROUTE TOO CABLE TRAYR CENTER ONCENTER ON 00 ENTRY DOORS 6"6 1" CONDUIT FROM TRAY TO EMS PANEL 10 NNNNNNN TTT 2 GA T O R AT AD E AD 2 1 SAFE PSSPSPSPS 24" CHECKOUT SCENARIO SC9 RIGHT NO BELTHC GDM10 PEPSI VR10VR COKECOCOCOOOO GDM10 PEPSI 0222222222 IN 3 .8 1000000 6 3B303B33B3B SODAOOOOOO COOLEROOO ICE CREAMCER FREEZERE M P E P S I EPE P S EEPEPEEPEEPE PEEEE M PEEPEEPEP SI PSSI P PE PEPEEE M ST A C K CKCKKKK TA C CCAA SODADADAAAA COOLERR 5' 2" 3 28 .0 .1 A.7A.7 .2 1 2 E 4 5 A.7A.7 LINE OF CANOPY ABOVEP SHOWN DASHED TYP.E 16 106b 8" SPLIT FACE CMU PAINTED TO MATCH SIDE WALL PANELS. TOP OF FIXTURE TO BE AFFIXED TO DRIED PINE NAILER BY DOLLAR GENERAL MERCHANDISING DEPT DRINK FIXTURE WALL MOUNTING SUPPORT NOTES: 1.PROVIDE AND INSTALL 2X6 WHITE PINE - GRADE 2 OR BETTER. 2. PROVIDE AND INSTALL 2X4 WHITE PINE - GRADE 2 OR BETTER. 3.FASTEN THE 2X6 TO THE WALL WITH THE TOP EDGE OF THE BOARD AT 81" A.F.F., REFER TO FIXTURE PLAN FOR LENGTH AND LOCATION OF BOARD. 4.FASTEN THE 2X4 TO THE WALL WITH THE TOP EDGE OF THE BOARD AT 12" A.F.F., REFER TO FIXTURE PLAN FOR LENGTH AND LOCATION OF BOARD. 5. PRE-DRILL PILOT HOLES IN ALL BOARDS PRIOR TO INSTALLATION TO PREVENT WOOD SPLITS. 6.SECURE THE 2X6 WITH TWO SELF-TAPPING SCREWS. MINIMUM SCREW SIZE IS 4"x 1/4". 7. FASTEN THE 2X4 WITH WITH SELF-TAPPING SCREW PER WALL STUD. MINIMUM SCREW SIZE IS 4"x 1/4". 8.CAULK THE EDGES OF THE 2X6 AT THE TOP AND BOTTOM WHERE IT MEETS THE WALL PRIOR TO PAINTING. 9. PRIME AND PAINT BOTH BOARDS TO MATCH WALL COLOR.FINISHED FLOOR 12 " 78" 5 1 / 2 " 22 CONTRACTOR TO PROVIDE AND INSTALL 2x6 WHITE PINE GRADE 2 OR BETTER FIXTURE SUPPLIED & INSTALLED BY DOLLAR GENERAL MERCHANDISING DEPT FIXTURE SUPPLIED AND INSTALLED BY DOLLAR GENERAL MERCHANDISING DEPARTMENT LINE OF FREEZER COOLERS BEYOND ANCHOR BOARD: CONTRACTOR TO PROVIDE AND INSTALL 2x6 WHITE PINE GRADE 2 OR BETTER, FURR OUT A REQ'D TO BE FLUSH WITH FACE OF STL FRAMES ANCHOR BOARD: CONTRACTOR TO PROVIDE AND INSTALL 2x4 WHITE PINE GRADE 2 OR BETTER, FURR OUT AS REQ'D TO BE FLUSH WITH STEEL FRAMES CONTRACTOR TO PROVIDE AND INSTALL 2x4 WHITE PINE GRADE 2 OR BETTER INTERIOR FACE OF PEMB FRAMING BEYOND MTL LINER PANELS CONTRACTOR TO FURR OUT ANCHOR BOARDS AS REQUIRED TO BE FLUSH WITH STEEL FRAMES 3'-0" SALES/ RECEIVING DOOR DOOR STOP ALUMINUM CORNER GUARDS MOP SINK 5'-0" OF 48" HIGH FRP WATER HEATER "EWH-2" ON SHELF ABOVE MOP SINK MOP HOLDER 8'-0" HIGH WING WALL 3'-0" OF 48" HIGH FRP FAUCET THIS WALL INSULATION WITH VAPOR BARRIER METAL LINER PANELS (BY PEMB) INSTALLED DIRECTLY TO METAL BUILDING GIRTS 1/2" GYPSUM BOARD METAL BUILDING COLUMNS SHALL BE STRAIGHT. TAPERED COLUMNS REQUIRE WRITTEN APPROVAL. MAINTAIN INTERIOR CLEARANCE OF 68'-0" BETWEEN FACE OF COLUMNS ON SALES FLOOR. PRE-FINISHED METAL WALL PANELS 21'-0" BI-PART WITH TRANSOM AND GLASS. COLOR: BRONZE FINISH. SHIM AND ANCHOR PER MANUFACTURERS RECOMMENDATIONS. PROVIDE CONTINUOUS SEALANT AND BACKER ROD ON BOTH SIDES (TYP.) 10'- 0" METAL TRACK WOOD NAILER AS REQUIRED METAL TRACK SEALANT BOTH SIDES FINISH FLOOR 1/2" MIN GYPSUM BOARD (BOTH SIDES) ON 3 5/8" 20 GA. CORROSIVE- RESISTIVE MTL STUDS @ 16" O.C.METAL TRACK SEALANT BOTH SIDES ACOUSTICAL TILE CEILING AND GRID, WHERE OCCURS, REFER TO REFLECTED CEILING PLAN R-13 INSULATION BLANKET @ TOILET ROOM WALLS FINISH FLOOR 1/2" MIN GYPSUM BOARD (BOTH SIDES) ON 3 5/8" METAL STUDS. METAL STUDS @ 16" O.C TO UNDERSIDE OF DECK ABOVE. GYPSUM BOARD TO RUN TO UNDERSIDE OF DECK ABOVE AT ALL "OPEN TO DECK ABOVE" AREAS OR TO 6" ABOVE CEILINGS. (USE MOISTURE RESISTANT GYPSUM BOARD AT WET LOCATIONS). NOTES: 1. DO NOT FASTEN GYPSUM BOARD WITHIN 2" OF BOTTOM OF SLIP TRACK. 2. IN PLACE OF CONTINUOUS SLIP TRACK - METAL STUD CONTRACTOR MAY USE "VERTICLIP" BRAND SLIP CONNECTION TO STRUCTURE. 3. SCREW ANCHORS SHALL NOT EXTEND BEYOND TOP OF DECK ELEVATION. REF E R T O R E F L E CTE D CEI L I N G P L A N FO R CEI L I N G H E I GHT 6" GALVANIZED METAL RUNNER, FASTEN TO STUDS ABOVE AT 24" O.C. CONTINUOUS DEFLECTION RUNNER STANDING SEAM METAL ROOF (BY PEMB MANUFACTURER) ATTACH WALLS TO METAL STUDS RUNNING BETWEEN PURLINS - STUDS TO BE CONTINOUS ALUMINUM CAP - PAINT TO MATCH WALL VERIFY REQUIRED FIRE-RATING WITH LOCAL AUTHORITY. 1, 2, 3 OR 4 HOUR RATED UL#U419 FOR FIRE RATING: COMPLETELY FILL VOIDS AT TOP OF WALLS, AROUND PENETRATION OF JOISTS, BEAMS, PIPES, DUCT, ETC. PER U.L. #HW-D-0060 AND #HW-D-0005; MIN. 5/8" THICKNESS OF FILL MATERIAL INSTALLED ON EACH SIDE OF WALL BETWEEN TOP OF WALLBOARD AND ALL SURFACES OF THE STEEL DECK, FLUSH WITH EACH SURFACE OF WALLBOARD 1 HR. = 1 LAYER GYP BD EACH SIDE 2 HR. = 2 LAYERS GYP BD EACH SIDE 3 HR. = 3 LAYERS GYP BD EACH SIDE 4 HR. = 4 LAYERS GYP BD EACH SIDE -FIRE RATED GYP BD TO BE: U.S. GYPSUM CO. - TYPE SCX, SHX, WRX, IP-X1, AR, C, WRC OR IP-X2. -FIRE TAPE GYP BD IN LIEU OF STANDARD TAPING & SANDING. METAL TRACK FIRE CAULK. TYPICAL BOTH SIDES FINISH FLOOR CONTINUOUS DEFLECTION RUNNER 1/2" MINIMUM TYPE 'X' GYPSUM BOARD TO DECK ABOVE (BOTH SIDES) ON 3 5/8" 20 GA. MTL STUDS @ 16" O.C. 6" FIRE CAULK. TYP BOTH SIDES NOTES: 1. DO NOT FASTEN GYPSUM BOARD WITHIN 2" OF BOTTOM OF SLIP TRACK. 2. IN PLACE OF CONTINUOUS SLIP TRACK - METAL STUD CONTRACTOR MAY USE "VERTICLIP" BRAND SLIP CONNECTION TO STRUCTURE. 3. SCREW ANCHORS SHALL NOT EXTEND BEYOND TOP OF DECK ELEVATION. ATTACH WALLS TO METAL STUDS RUNNING BETWEEN PURLINS - STUDS TO BE CONTINOUS GALVANIZED METAL RUNNER, FASTEN TO STUDS ABOVE AT 24" O.C. 44 7 M A I N ST. (ROUT E - 2 8 ) W. Y A R M O U T H , M A SCALE:NTS (1/8"=1'-0") FLOOR PLAN1 A01 FLOOR PLAN KEYED NOTES RECEIVING DOOR BUZZER - TORK MDL.#TA725 OR EQUAL DOOR SCOPE. REFER TO DOOR SCHEDULE. WEATHER STRIP & LOW PROFILE THRESHOLD. SEE DOOR SCHEDULE. STRIPE FLOOR FOR DESIGNATED EGRESS PATH (PAINT YELLOW) AND 3'-0" DESIGNATED EMS PANEL CLEARANCE (PAINT RED). PROVIDE AND INSTALL A TEN GALLON WATER HEATER (OR LARGER IF REQUIRED BY CODE) ABOVE THE MOP SINK. 3 5/8" METAL STUD WITH 1/2" MINIMUM GYPSUM BOARD (BOTH SIDES). REFER TO NOTED WALL SECTION. REFER TO ROOM FINISH SCHEDULE FOR GYPSUM BOARD HEIGHT AT ANY PARTICULAR WALL. NOT USED. NOT USED CONCRETE SLAB WITH 6X6XW1.4 WELDED WIRE MESH OVER POLYETHYLENE VAPOR BARRIER (MIN. 10 MM THICK) OVER CRUSHED STONE BASE, TYPICAL. PROVIDE CONTROL JOINTS AS SHOWN ON S03. METAL BUILDING FRAME. REFER TO NOTED WALL SECTION FOR ADDITIONAL INFORMATION. 1/2" GYPSUM BOARD (TO 10'-0" A.F.F.) OVER METAL LINER PANELS AND INSULATION WITH VAPOR BARRIER. HARDIE-BOARD (LAP BOARD) SIDING AS SCHEDULED MC CUE CART AND BUMPER GUARDS. TOP INSTALLED @ 3'-5" A.F.F. ORDER TRIM KIT FOR THIS PROTOTYPE. STOREFRONT SYSTEM. REFER TO NOTED WALL SECTION FOR ADDITIONAL INFORMATION. CONTINUE GYPSUM BOARD ABOVE STOREFRONT TO DECK. LINE OF SOFFIT OR CANOPY ABOVE. A.D.A. COMPLIANT ACCESSIBLE RAMP WITH YELLOW PAINTED SIDES TO ACCESSIBLE PARKING STALLS. BROOM FINISH CONCRETE SIDEWALK, TYPICAL. SLOPE CONCRETE 1/8" PER FOOT AWAY FROM BUILDING. 1 2 3 4 5 6 8 WALL HYDRANT. REFER TO PLUMBING DRAWINGS FOR ADDITIONAL INFORMATION. REFRIGERATION BY DOLLAR GENERAL. ROUND PIPE STEEL COLUMN WITH RECESSED BASE PLATE. PAINT SW7005 PURE WHITE. WRAP COLUMN WITH TIGHT LOOP CARPET (BLACK) FROM BASE TO 48" A.F.F. 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 POWER POLE. COORDINATE FINAL LOCATION WITH ELECTRICAL DRAWINGS AND FINAL DOLLAR GENERAL FIXTURE PLAN (F01). 24 CONTROL JOINTS ARE TO BE PLACED ALONG COLUMN LINES AND MID POINT BEWTEEN COLUMN LINES. COORDINATE WITH STRUCTURAL DRAWINGS. 25 FLOOR AREA AT BASE OF COLUMNS, WITHIN THE CONST JOINTS, TO BE PAINTED BLACK MAGIC TINT. 26 ENDCAP COOLER/FREEZER TO BE HARDWIRED THROUGH WHITE SO CORD WITH DUPLEX AT END. GC TO LEAVE BOTTOM HANGING AT 80" A.F.F. (SEE ELECTRICAL). CORD ANCHORED TO PURLINS ABOVE. COORDINATE LOCATION WITH FINAL DOLLAR GENERAL FIXTURE PLAN. 27 MC CUE RAILING IN FRONT OF ELECTRICAL PANELS. 8'-0" LONG WITH TOP TWO RAILINGS AND NO MIDDLE POST. 28 CART AREA. REFER TO 5 & 6/A06. METAL LINER PANELS TO UNDERSIDE OF ROOF DECK. (BY PRE-ENGINEERED BUILDING MANUFACTURER).7 STRIPE FLOOR FOR DESIGNATED ADA EGRESS PATH (PAINT YELLOW).4A 26A26A KIOSK COOLER TO BE HARDWIRED THROUGH WHITE SO CORD WITH QUAD AT END. GC TO LEAVE BOTTOM HANGING AT 48" A.F.F. (SEE ELECTRICAL). CORD ANCHORED TO PURLINS ABOVE. COORDINATE LOCATION WITH FINAL DOLLAR GENERAL FIXTURE PLAN. PLAN NORTH 2 A01 SCALE:1/2"=1'-0" ANCHOR BOARD DETAIL 3 A01 SCALE:1/2"=1'-0" ENLARGED MOP SINK PLAN 4 A01 SCALE:1/2"=1'-0" DETAIL AT COLUMN 5 A01 SCALE:1/2"=1'-0" EXTERIOR CORNER DETAIL 6A A01 SCALE:1"=1'-0" TYPICAL PARTITION 6B A01 SCALE:1"=1'-0" FIRE-RATED PARTITION (IF REQ'D)7 A01 SCALE:1"=1'-0" PARTITION-OFFICE & BREAKROOM ADDRESS # HARDIE-BOARD FASCIA ALUM COPING DECORATIVE COLUMN ENCLOSURE HARDIE-TRIM LOW GABLE MANSARD ARCH SHINGLES. HIGH GABLE MANSARD ARCH SHINGLES. DORMER TYP. GABLE OVERFRAMING SIGN BAND ARCH SHINGLES. CHANNEL LETTER SIGNAGE BY DOLLAR GENERAL HARDIE-BOARD CLAPBOARD HARDIE-BOARD PILASTER COMPOSITE CEDAR SHAKES 19 ' - 2 12" INSULATED ENTRY 20 ' - 1 " 10 ' - 0 " 17 ' - 8 12"24 ' - 4 12" HARDIE-BOARD CLAPBOARD X3 X5 X6X3X6X3X1 X4 X3 X1X3 X3 X4X3 X3 X7X3X6 X7 X3 X3 X6 X4X12X13 X6 X4X12X13 X3 X9 X2 X10 X3 X3 X3 X4 X3X1X3 X6 X4 X3 X3 X3 X7 X3X13X3X13 ADDRESS # HIGH GABLE MANSARD ARCH SHINGLES. DORMER HARDIE-TRIM HARDIE-BOARD CLAPBOARD INSUALTED STOREFRONT ALUM COPING HARDIE-BOARD PILASTER 10 ' - 0 " GOOSE NECK LIGHTING TYP. HARDIE-BOARD CLAPBOARD CEMEMTITOUS WINDOW PANEL PAINT TO MATCH ADJ SIDING TYP. X11 X9 X3X10X2X6 X6 X4X12X13 X6 X4X12X13X3 X3 X3 X7 X6 X4 X3 X3X5X5 X3 X4 X3 X3 X7 X3 X3 20 ' - 1 " FIXED WINDOW WITH GLAZING INSET MUTTON BARS INTERIOR EXPOSED TYP. HIGH SIDE X4X4X3 X3X13X13 X13 X13X3 X3 FIXED WINDOW WITH GLAZING INSET MUTTON BARS INTERIOR EXPOSED TYP. HIGH SIDE HARDIE-BOARD CLAPBOARD HARDIE-TRIM 10 ' - 0 " ASPHALT SHINGLED RIDGE ASPHALT SHINGLED RIDGE LOWER MANSARD GABLE HIGH MANSARD GABLE GALVALUME METAL PANEL X6 X1 X3X1 GABLE OVERFRAMING SIGN BAND ARCH SHINGLES. SHED DORMER BEYOND GABLE MANSARD 20 ' - 1 " 24 ' - 4 12" X3 X7 X3 X3 X3 X4 X3 X1X3 X6 X11 X11X1X3 X14 X6 X14 X1 X3 X1 X3 X14 GALVALUME METAL PANEL HIGH MANSARD GABLE ASPHALT SHINGLED RIDGE HARDIE-BOARD CLAPBOARD HARDIE-TRIM X5 X14X15 X11 X11 X14 X15 X1 X3 X3 X4X1X3X3 X1 X6 X3 X7 X3 X3 DECORATIVE COLUMN ENCLOSURE LOWER MANSARD GABLE 10 ' - 0 " 24 ' - 1 0 " 20 ' - 6 12" 18 ' - 4 3 4" HIGH MANSARD GABLE HARDIE-BOARD CLAPBOARD GABLE OVERFRAMING SIGN BAND ARCH SHINGLES. TAG NOTES X2 COLOR: LIGHT MIST COLOR: LIGHT MIST X5 COLOR: ARCTIC WHITE COPING BY GC PRE-FINISHED X7 FIBERGLASS ASPHALT ARCHITECTUAL SHINGLE GAF TIMBERLINE 30 YEAR ARCH SHINGLE O.A.E. NONE "K" SERIES GUTTER & DOWNSPOUT TO MATCHX11 PAINT : DOOR & FRAME HARDIEE-PLANK LAP SIDING EXTERIOR FINISH SCHEDULE PRE-FINISHED; 6" EXPOSURE HARDIEE -SHINGLE SIDING MATERIAL/ MFG. COLOR/ NO. X3 PRE-FINISHED 6" EXPOSURE HARDIEE-TRIM BOARDS PRE-FINISHED X1 METAL COPING COLOR: TO MATCH STANDARD METAL GUTTER & DOWNSPOUT PRE-FINISHEDCOLOR: TO MATCH X8 PEWTER GRAY SIGNAGE BY OTHERSX9 GOOSENECK LIGHTINGX10 UNDER SEPARATE PERMIT BLACK X3 BY PEMB ENTRY DOOR/ STOREFRONT COLONIAL WHITE PRE-FINSHEDX12 GLAZING AS SCHEDULED CLEARX13 NONE X6 METAL DOOR & FRAME PAINT: TO MATCH COLOR: TBD X3 X1 X4 HARDIEE-TRIM BOARDS COLOR: LIGHT MIST PRE-FINISHED X3 STANDING SEAM ROOFING GALVALUME BY PEMBX14 ALUM FASCIA BY PEMBX15TO MATCH X3 SCALE:1/8"-1'-0" PROPOSED SIDE ELEVATION (PARKING LOT)1 SCALE:1/8"-1'-0" PROPOSED FRONT ELEVATION (RT. 28) 2 SCALE:1/8"-1'-0" PROPOSED SIDE ELEVATION 3 SCALE:1/8"-1'-0" PROPOSED REAR ELEVATION4