HomeMy WebLinkAbout2026 FIRE ALARM INSPECTION BUILDING REPORT2026 Town of Yarmouth Water Department 99 Buck Island Road West Yarmouth, MA 02673 (508)776-1892 Building Contact:Luke White Title:Contact Company:Cape Cod Alarm Contact:Chad Benaka Title:Service Tech Fire Alarm Systems INSPECTIONCERTIFICATE Aug 12, 2026Inspection Date: Tested to NFPA 72 Standards This Inspection was performed in accordance with applicable NFPA Standards. The subsequent pages of this report provide performance measurements, listed ranges of acceptable results, and complete documentation of the inspection. Whenever discrepancies exist between acceptable performance standards and actual test results, notes and/or recommended solutions have been proposed or provided for immediate review and approval. Page of 2 15 Executive Summary Cape Cod Alarm Download Date: 08/13/2026 EXECUTIVE SUMMARY Generated by: BuildingReports.com Building Information Town of Yarmouth Water Department 99 Buck Island Road West Yarmouth, MA 02673 United States of America Contact: Luke White Phone: (508)776-1892 Fax: Mobile: Email: Inspection Performed By Cape Cod Alarm204 Old Townhouse RoadWest Yarmouth, MA 02673United States of America Inspector: Chad Benaka Phone: (508) 398-6316 Fax: Mobile: Email: service@capecodalarm.com System Control Unit Manufacturer: Notifier Inspection Date: 08/07/2026 IDC Style: E Model Number: System 500 Install Date: 08/07/2026 SLC Style: N/A Software Version:Version Date: 12/31/1969 NAC Style: E Location: 2nd Floor Electrical Room Disconnect Location:Disconnect Type: Current Protection: Breaker Monitoring Company: Cape Cod Alarm Phone:Account #: S29583 Central Station Signal Verification Type: Mesh Radio Network Mfg: AES Model #: 7788F Test Time/Date: 8/7/26 2:44:18 PM Restore Time: 3:44 PM Note: Type of Signal Signal Confirmed Time Notes Alarm Signal 3:25 PM Trouble Signal 3:26 PM Page of 3 15 Executive Summary Cape Cod Alarm Download Date: 08/13/2026 Building: Town of Yarmouth Water Department Contact: Luke White Company: Cape Cod Alarm Inspector: Chad Benaka Inspection Summary Category Total Items Serviced Passed Failed/Other Qty %Qty %Qty %Qty % Control 6 13.95%6 100.00%6 100.00%0 0.00% Indicating 15 34.88%15 100.00%13 86.67%2 13.33% Initiating 11 25.58%11 100.00%10 90.91%1 9.09% Monitor 2 4.65%2 100.00%2 100.00%0 0.00% Supervisory 9 20.93%9 100.00%9 100.00%0 0.00% Totals 43 100%43 100.00%40 93.02%3 6.98% Certification Page of 4 15 Discrepancy Report Cape Cod Alarm Download Date: 08/13/2026 Control Panel: 1 - Notifier System 500Building: Town of Yarmouth Water Department DISCREPANCY REPORT Deficiency, Impairment, and Observation Generated by: BuildingReports.com The Discrepancy Report consolidates each discrepancy listed within the various Testing sections of your Inspection. Discrepancies are listed by Category, and grouped by device type. The description of the problem is provided and where appropriate, code references are listed for your convenience. Any item that was inspected that is subject to a recall or part of a manufacturer's replacement/upgrade program is included. This section is now enhanced by BuildingReports AI, which helps refine applicable manufacturer recalls and replacement notices, enabling service providers and facilities to address potential issues more quickly. Building: Town of Yarmouth Water Department Items listed for Recall or Replacement/Upgrade Device Type Manufacturer Model Number Date Qty No recalled items found during this inspection. Discrepancies ScanID Location Problem Address Reference INDICATING Remote Indicator B9519871 2nd Floor above Boiler Room Door Failed Operation 1 NFPA72 14.2.2.2.2 B9519869 2nd Floor above Electrical Room Door Failed Operation 1 NFPA72 14.2.2.2.2 INITIATING Pull Station B9519901 1st Floor Rear Garage Right Side Exit Door Damaged/Worn 1 NFPA72 14.2.2.2.2 Code References NFPA72 14.2.2.2.2 System deficiencies shall be corrected. Page of 5 15 Proposed Solutions Report Cape Cod Alarm Download Date: 08/13/2026 Control Panel: 1 - Notifier System 500Building: Town of Yarmouth Water Department PROPOSED SOLUTIONS REPORT Generated by: BuildingReports.com The Proposed Solution Report provides a solution for each discrepancy listed on the Discrepancy Report. Provide a check mark where indicated to approve repairs listed within the report. Items listed as T/M are available for repair on a Time and Materials basis. ScanID Location Solution Model #Cost Fixed Date INDICATING Remote Indicator B9519871 2nd Floor above Boiler Room Door Investigate/Replace RA400Z T/M B9519869 2nd Floor above Electrical Room Door Investigate/Replace RA400Z T/M INITIATING Pull Station B9519901 1st Floor Rear Garage Right Side Exit Door Replace NBG-10 T/M Customer WO/PO #: (none) Internal WO/PO #: (none) Total: T/M Page of 6 15 Inspection & Testing Cape Cod Alarm Download Date: 08/13/2026 Control Panel: 1 - Notifier System 500Building: Town of Yarmouth Water Department INSPECTION & TESTING Generated by: BuildingReports.com The Inspection & Testing section lists all of the items inspected in your building. Items are grouped by Passed or Failed/Other . Items are listed by Category. Each item includes the services performed, and the time & date at which testing occurred. Device Type Location Service Time Date PASSED Control Annunciator 1st Floor Office Area Side Exit Door Tested 3:08:23 PM 08/07/2026 Battery In AES Transmitter Tested 2:42:10 PM 08/07/2026 Battery In Fire Alarm Control Panel Tested 2:46:26 PM 08/07/2026 Battery In Fire Alarm Control Panel Tested 2:46:48 PM 08/07/2026 Communicator 2nd Floor Electrical Room Tested 2:44:18 PM 08/07/2026 Control Panel 2nd Floor Electrical Room Tested 2:36:49 PM 08/07/2026 Indicating Horn/Strobe 1st Floor Garage Front Wall Middle Tested 2:51:16 PM 08/07/2026 Horn/Strobe 1st Floor Garage Left Side Exit Door Tested 2:49:09 PM 08/07/2026 Horn/Strobe 1st Floor Garage Rear Wall Middle Tested 2:52:01 PM 08/07/2026 Horn/Strobe 1st Floor Garage Right Side Exit Door Tested 2:58:54 PM 08/07/2026 Horn/Strobe 1st Floor Office Area Main Entry Tested 3:07:19 PM 08/07/2026 Horn/Strobe 1st Floor Office Area Main Hallway Tested 3:04:35 PM 08/07/2026 Horn/Strobe 1st Floor Office Area Side Exit Door Tested 3:03:35 PM 08/07/2026 Horn/Strobe 1st Floor Rear Garage Left Side Door Tested 2:53:20 PM 08/07/2026 Horn/Strobe 2nd Floor Garage Front Tested 2:38:06 PM 08/07/2026 Horn/Strobe 2nd Floor Garage Rear Tested 2:38:32 PM 08/07/2026 Strobe 1st Floor Men’s Restroom Tested 3:00:42 PM 08/07/2026 Strobe 1st Floor Women’s Restroom Tested 3:02:17 PM 08/07/2026 Page of 7 15 Inspection & Testing Cape Cod Alarm Download Date: 08/13/2026 Device Type Location Service Time Date PASSED (continued) Indicating (continued) Strobe 1st Floor Office Area Conference Room Tested 3:05:36 PM 08/07/2026 Initiating Pull Station 1st Floor Garage Left Side Exit Door Tested 2:49:54 PM 08/07/2026 Pull Station 1st Floor Garage Right Side Exit Door Tested 2:59:11 PM 08/07/2026 Pull Station 1st Floor Office Area Main Entry Tested 3:06:58 PM 08/07/2026 Pull Station 1st Floor Office Area Side Exit Door Tested 3:03:07 PM 08/07/2026 Pull Station 1st Floor Rear Garage Left Side Exit Door Tested 2:54:58 PM 08/07/2026 Smoke Detector 2nd Floor Boiler Room Tested 2:40:11 PM 08/07/2026 Smoke Detector 2nd Floor Electrical Room Tested 2:39:13 PM 08/07/2026 Waterflow Switch 1st Floor Garage Sprinkler Area Tested 3:14:41 PM 08/07/2026 Waterflow Switch 1st Floor Garage Sprinkler Area Tested 3:14:44 PM 08/07/2026 Waterflow Switch 1st Floor Garage Sprinkler Area Tested 3:14:50 PM 08/07/2026 Monitor Monitoring Alarm Signal Tested 2:44:51 PM 08/07/2026 Monitoring Trouble Signal Tested 2:45:26 PM 08/07/2026 Supervisory Air Pressure Switch 1st Floor Garage Sprinkler Area Tested 3:12:14 PM 08/07/2026 Air Pressure Switch 1st Floor Garage Sprinkler Area Tested 3:13:34 PM 08/07/2026 Air Pressure Switch 1st Floor Garage Sprinkler Area Tested 3:13:48 PM 08/07/2026 Air Pressure Switch 1st Floor Garage Sprinkler Area Tested 3:13:57 PM 08/07/2026 Tamper Switch 1st Floor Garage Sprinkler Area Tested 3:15:00 PM 08/07/2026 Tamper Switch 1st Floor Garage Sprinkler Area Tested 3:15:58 PM 08/07/2026 Tamper Switch 1st Floor Garage Sprinkler Area Tested 3:16:20 PM 08/07/2026 Tamper Switch 1st Floor Garage Sprinkler Area Tested 3:16:23 PM 08/07/2026 Tamper Switch 1st Floor Garage Sprinkler Area Tested 3:16:27 PM 08/07/2026 FAILED/OTHER Page of 8 15 Inspection & Testing Cape Cod Alarm Download Date: 08/13/2026 Device Type Location Service Time Date FAILED/OTHER (continued) Indicating Remote Indicator 2nd Floor above Boiler Room Door Tested 3:37:45 PM 08/12/2026 Remote Indicator 2nd Floor above Electrical Room Door Tested 3:43:06 PM 08/12/2026 Initiating Pull Station 1st Floor Rear Garage Right Side Exit Door Tested 3:26:58 PM 08/12/2026 Page of 9 15 Service Summary Cape Cod Alarm Download Date: 08/13/2026 SERVICE SUMMARY Generated by: BuildingReports.com The Service Summary section provides an overview of the services performed in this report. Building: Town of Yarmouth Water Department Device Type Service Quantity PASSED Air Pressure Switch Tested 4 Annunciator, LED List Tested 1 Battery, Sealed Lead Acid Tested 3 Communicator, Mesh Radio Network Tested 1 Control Panel, Conventional Tested 1 Horn/Strobe Tested 10 Monitoring, Alarm Signal Tested 1 Monitoring, Trouble Signal Tested 1 Pull Station, Dual Action Tested 5 Smoke Detector Tested 2 Strobe Tested 3 Tamper Switch Tested 5 Waterflow Switch Tested 3 Total 40 FAILED/OTHER Pull Station, Dual Action Tested 1 Remote Indicator Tested 2 Total 3 Grand Total 43 Page of 10 15 Sound and Visual Testing Cape Cod Alarm Download Date: 08/13/2026 SOUND AND VISUAL TESTING Generated by: BuildingReports.com The Sound and Visual Testing section lists various points throughout your building where audible and visual alarm notification devices were tested. Any bar-coded audible and visual devices will appear in the Inspection and Testing section of this report. Items in this section are grouped by Passed or Failed/Other. Where specific decibel readings were recorded, they will appear under the ambient and alarm columns. The Voice column indicates whether the Sound Test Point passed the Voice Intelligibility requirements. The STI or Sound Transmission Index is shown if recorded. Building: Town of Yarmouth Water Department Audible/Visual Appliances Location Comment Ambient Alarm Synched ScanID PASSED Horn/Strobe 2nd Floor Garage Rear Passed ☐A9021805 2nd Floor Garage Front Passed ☐A9021806 1st Floor Garage Left Side Exit Door Passed ☐B9519899 1st Floor Garage Rear Wall Middle Passed ☐B9519900 1st Floor Office Area Side Exit Door Passed ☐B9519902 1st Floor Garage Right Side Exit Door Passed ☐B9519906 1st Floor Rear Garage Left Side Door Passed ☐B9519908 1st Floor Garage Front Wall Middle Passed ☐B9519909 1st Floor Office Area Main Entry Passed ☐B9519910 1st Floor Office Area Main Hallway Passed ☐B9519919 Strobe 1st Floor Women’s Restroom Passed ☐B9519903 Page of 11 15 Sound and Visual Testing Cape Cod Alarm Download Date: 08/13/2026 Location Comment Ambient Alarm Synched ScanID PASSED (continued) Strobe (continued) 1st Floor Men’s Restroom Passed ☐B9519904 1st Floor Office Area Conference Room Passed ☐B9519918 Page of 12 15 Battery & Power Supply Testing Cape Cod Alarm Download Date: 08/13/2026 Control Panel: 1 - Notifier System 500Building: Town of Yarmouth Water Department BATTERY & POWER SUPPLY TESTING Generated by: BuildingReports.com The Battery & Power Supply Testing section details the readings and measurements of batteries and power supplies used to provide power to the fire alarm and life safety systems. Items are grouped by Passed or Failed/Other. Battery Type Location Rated Ah Rated Volts Pre Test Post Test Min Ah Teste d Ah MFG Date PASSED Sealed Lead Acid In AES Transmitter 7 12 100%100%08/29 /2025 Sealed Lead Acid In Fire Alarm Control Panel 7 12 100%100%08/07 /2026 Sealed Lead Acid In Fire Alarm Control Panel 7 12 100%100%08/07/2026 Page of 13 15 Inventory & Warranty Report Cape Cod Alarm Download Date: 08/13/2026 Control Panel: 1 - Notifier System 500Building: Town of Yarmouth Water Department INVENTORY & WARRANTY REPORT Generated by: BuildingReports.com The Inventory & Warranty Report lists each of the devices and items that are included in your Inspection Report. A complete inventory count by device type and category is provided. Items installed within the last 90 days, within the last year, and devices installed for two years or more are grouped together for easy reference. Building: Town of Yarmouth Water Department Device or Type Category % of Inventory Quantity Air Pressure Switch Supervisory 9.30%4 Annunciator Control 2.33%1 Battery Control 6.98%3 Communicator Control 2.33%1 Control Panel Control 2.33%1 Horn/Strobe Indicating 23.26%10 Monitoring Monitor 4.65%2 Pull Station Initiating 13.95%6 Remote Indicator Indicating 4.65%2 Smoke Detector Initiating 4.65%2 Strobe Indicating 6.98%3 Tamper Switch Supervisory 11.63%5 Waterflow Switch Initiating 6.98%3 Type Qty Model #Description Install Date NEW (UNDER 90 DAYS) AES Communicator 1 7788F Mesh Radio Network 08/07/2026 Central Page of 14 15 Inventory & Warranty Report Cape Cod Alarm Download Date: 08/13/2026 Type Qty Model #Description Install Date NEW (UNDER 90 DAYS)(continued) Central (continued) Tamper Switch 1 BFV 08/07/2026 Tamper Switch 4 OSYSU-2 08/07/2026 Gentex Horn/Strobe 1 SHG-24-15/75WR 08/07/2026 Strobe 2 08/07/2026 Notifier Control Panel 1 System 500 Conventional 08/07/2026 Pull Station 6 NBG-10 Dual Action 08/07/2026 Potter Air Pressure Switch 3 PS10-2A 08/07/2026 Air Pressure Switch 1 PS40-2A 08/07/2026 Waterflow Switch 3 VSR-F 08/07/2026 Power Patrol Battery 2 FAS1075 Sealed Lead Acid 08/07/2026 Space Age Annunciator 1 LED List 08/07/2026 System Sensor Remote Indicator 2 RA400Z 08/07/2026 Smoke Detector 2 2100T 08/07/2026 Strobe 1 PS24-LO 08/07/2026 Wheelock Horn/Strobe 9 08/07/2026 (manufacturer not specified) Monitoring 1 Alarm Signal 08/07/2026 Monitoring 1 Trouble Signal 08/07/2026 IN SERVICE - 90 DAYS - 1 YEAR Page of 15 15 Inventory & Warranty Report Cape Cod Alarm Download Date: 08/13/2026 Type Qty Model #Description Install Date IN SERVICE - 90 DAYS - 1 YEAR (continued) Power Patrol Battery 1 FAS1075 Sealed Lead Acid 08/29/2025