HomeMy WebLinkAbout792-792-18358 Norfolk Ave, Easton, MA 02375 • Tel 508 822 6934 • www.swcole.com Report of Concrete Compressive Strength ASTM C31, ASTM C39, ASTM C1231 Project Name:Yarmouth MA - Town of Yarmouth Water Resource Recovery Facility - Concrete Testing Services Client:Wright-Pierce Project #:25-0468 Report Date:8/17/2026 Concrete Supplier:Cape Cod Ready Mix PLACEMENT INFORMATION Date Cast: 8/3/2026 Time Cast: 7:20 AM Date Received: 8/4/2026 Placement Location:SBR PIPE GALLERY UPPER SLAB UU EFFLUENT SLAB PROCESS BUILDING FOOTING NW, SW CORNER Placement Method:PUMP Cylinders Made By:Caleb Drinan Material Type:Concrete Cylinders Placement Vol. (yd ):64 Aggregate Size (in):1 1/2 Cylinder Size:6 x 12 INITIAL CURING CONDITION DELIVERY INFORMATION Temperatures Minimum (°F):Maximum (°F): Admixtures: TEST RESULTS Slump (in) (C-143):8 1/2 Air Content (%) (C-231):3 Air Temp (°F):74 Conc. Temp (°F) (C-1064):81 Load Number:1 Mixer Num.:75 Ticket Num.:53155 Cubic Yards:10 Design (psi):4500 Batch 6:29 AM Arrive 7:00 AM Depart 7:36 AM Cylinder Designation Defect (Y/N) Cylinder Weight (lbs) Cylinder Diameter (in) Cross Sectional Area (in ) Date Of Test Cure Type Cap Type Age (Days) Fracture Type Load (kips) Strength (psi) 792-183A N 29.25 6.03 28.56 8/10/2026 Lab Unbonded 7 5 134.33 4700 792-183B N 29.25 6 28.23 8/17/2026 Lab Unbonded 14 6 156.54 5540 792-183C 29.25 8/31/2026 Lab 28 792-183D 29.25 8/31/2026 Lab 28 792-183E 29.25 HOLD Lab 3 2 Remarks:Kaylie O'Sullivan Reviewed By