HomeMy WebLinkAbout2026 FIRE ALARM INSPECTION BUILDING REPORT2026 Cape Cod Mechanical Systems 8 Fruean Avenue South Yarmouth, MA X (508)394-7501 Building Contact:Shane Wintringham Title:Contact Company:Cape Cod Alarm Contact:Chad Benaka Title:Service Tech Fire Alarm Systems INSPECTIONCERTIFICATE Aug 18, 2026Inspection Date: Tested to NFPA 72 Standards This Inspection was performed in accordance with applicable NFPA Standards. The subsequent pages of this report provide performance measurements, listed ranges of acceptable results, and complete documentation of the inspection. Whenever discrepancies exist between acceptable performance standards and actual test results, notes and/or recommended solutions have been proposed or provided for immediate review and approval. Page of 2 14 Executive Summary Cape Cod Alarm Download Date: 08/20/2026 EXECUTIVE SUMMARY Generated by: BuildingReports.com Building Information Cape Cod Mechanical Systems 8 Fruean Avenue South Yarmouth, MA X United States of America Contact: Shane Wintringham Phone: (508)394-7501 Fax: Mobile: Email: Inspection Performed By Cape Cod Alarm204 Old Townhouse RoadWest Yarmouth, MA 02673United States of America Inspector: Chad Benaka Phone: (508) 398-6316 Fax: Mobile: Email: service@capecodalarm.com System Control Unit Manufacturer: ESL Inspection Date: 08/18/2026 IDC Style: E Model Number: 1503 Install Date: 08/18/2000 SLC Style: N/A Software Version:Version Date: 12/31/1969 NAC Style: E Location: 1st Floor Storage Closet Disconnect Location:Disconnect Type: Current Protection: Breaker Monitoring Company: Cape Cod Alarm Phone:Account #: S52189 Central Station Signal Verification Type: Mesh Radio Network Mfg: AES Model #: 7058E Test Time/Date: 8/18/26 2:11:08 PM Restore Time: 3:22 PM Note: Type of Signal Signal Confirmed Time Notes Alarm Signal 2:38 PM Page of 3 14 Executive Summary Cape Cod Alarm Download Date: 08/20/2026 Building: Cape Cod Mechanical Systems Contact: Shane Wintringham Company: Cape Cod Alarm Inspector: Chad Benaka Inspection Summary Category Total Items Serviced Passed Failed/Other Qty %Qty %Qty %Qty % Control 5 20.00%5 100.00%5 100.00%0 0.00% Indicating 3 12.00%3 100.00%3 100.00%0 0.00% Initiating 16 64.00%16 100.00%10 62.50%6 37.50% Monitor 1 4.00%1 100.00%1 100.00%0 0.00% Totals 25 100%25 100.00%19 76.00%6 24.00% Certification Page of 4 14 Discrepancy Report Cape Cod Alarm Download Date: 08/20/2026 Control Panel: 1 - ESL 1503Building: Cape Cod Mechanical Systems DISCREPANCY REPORT Deficiency, Impairment, and Observation Generated by: BuildingReports.com The Discrepancy Report consolidates each discrepancy listed within the various Testing sections of your Inspection. Discrepancies are listed by Category, and grouped by device type. The description of the problem is provided and where appropriate, code references are listed for your convenience. Any item that was inspected that is subject to a recall or part of a manufacturer's replacement/upgrade program is included. This section is now enhanced by BuildingReports AI, which helps refine applicable manufacturer recalls and replacement notices, enabling service providers and facilities to address potential issues more quickly. Building: Cape Cod Mechanical Systems Items listed for Recall or Replacement/Upgrade Device Type Manufacturer Model Number Date Qty No recalled items found during this inspection. Discrepancies ScanID Location Problem Address Reference INITIATING Heat Detector B9520014 1st Floor Front Left Office Restroom Date Expired 1 NFPA72 Table 14.4.3.2 (17)(4)(c) B9520039 1st Floor Garage (1st from Office)Date Expired 1 NFPA72 Table 14.4.3.2 (17)(4)(c) B9520032 1st Floor Garage (2nd from Office)Date Expired 1 NFPA72 Table 14.4.3.2 (17)(4)(c) B9520033 1st Floor Garage (far end)Date Expired 1 NFPA72 Table 14.4.3.2 (17)(4)(c) B9520040 1st Floor Garage above Office Date Expired 1 NFPA72 Table 14.4.3.2 (17)(4)(c) Page of 5 14 Discrepancy Report Cape Cod Alarm Download Date: 08/20/2026 ScanID Location Problem Address Reference INITIATING (continued) Heat Detector (continued) B9520034 1st Floor Hallway Restroom Date Expired 1 NFPA72 Table 14.4.3.2 (17)(4)(c) Code References NFPA72 Table 14.4.3.2 (17) (4)(c) After 15 years from initial installation, replace all devices or have 2 detectors per 100 laboratory tested. Page of 6 14 Proposed Solutions Report Cape Cod Alarm Download Date: 08/20/2026 Control Panel: 1 - ESL 1503Building: Cape Cod Mechanical Systems PROPOSED SOLUTIONS REPORT Generated by: BuildingReports.com The Proposed Solution Report provides a solution for each discrepancy listed on the Discrepancy Report. Provide a check mark where indicated to approve repairs listed within the report. Items listed as T/M are available for repair on a Time and Materials basis. ScanID Location Solution Model #Cost Fixed Date INITIATING Heat Detector B9520014 1st Floor Front Left Office Restroom Replace 281BPL T/M B9520039 1st Floor Garage (1st from Office)Replace 284BPL T/M B9520032 1st Floor Garage (2nd from Office)Replace 284BPL T/M B9520033 1st Floor Garage (far end)Replace 284BPL T/M B9520040 1st Floor Garage above Office Replace 284BPL T/M B9520034 1st Floor Hallway Restroom Replace 281BPL T/M Customer WO/PO #:(none)Internal WO/PO #:(none)Total: T/M Page of 7 14 Notes & Recommendations Cape Cod Alarm Download Date: 08/20/2026 NOTES & RECOMMENDATIONS Generated by: BuildingReports.com The Notes & Recommendations Report details additional inspection notes made by the Inspectors during the course of the building inspection. Notes are grouped by Category. General Note Three of the garage heats are 16-20 feet high Page of 8 14 Inspection & Testing Cape Cod Alarm Download Date: 08/20/2026 Control Panel: 1 - ESL 1503Building: Cape Cod Mechanical Systems INSPECTION & TESTING Generated by: BuildingReports.com The Inspection & Testing section lists all of the items inspected in your building. Items are grouped by Passed or Failed/Other . Items are listed by Category. Each item includes the services performed, and the time & date at which testing occurred. Device Type Location Service Time Date PASSED Control Battery In AES Transmitter Tested 2:11:51 PM 08/18/2026 Battery In Fire Alarm Control Panel Tested 2:36:38 PM 08/18/2026 Battery In Fire Alarm Control Panel Tested 2:36:57 PM 08/18/2026 Communicator 1st Floor Storage Closet Tested 2:11:08 PM 08/18/2026 Control Panel 1st Floor Storage Closet Tested 2:14:08 PM 08/18/2026 Indicating Horn/Strobe 1st Floor Garage Restroom Tested 2:28:56 PM 08/18/2026 Horn/Strobe 1st Floor Garage Side Door Tested 2:31:22 PM 08/18/2026 Horn/Strobe 1st Floor Office Entry Tested 2:18:04 PM 08/18/2026 Initiating Heat Detector 1st Floor Garage Restroom Tested 2:28:04 PM 08/18/2026 Pull Station 1st Floor Garage Side Door Tested 2:31:02 PM 08/18/2026 Pull Station 1st Floor Office Entry Tested 2:19:52 PM 08/18/2026 Smoke Detector 1st Floor Back Office Tested 2:25:58 PM 08/18/2026 Smoke Detector 1st Floor Front Left Office Tested 2:22:09 PM 08/18/2026 Smoke Detector 1st Floor Garage Contractor’s Office Tested 2:30:06 PM 08/18/2026 Smoke Detector 1st Floor Hallway to Garage Tested 3:12:39 PM 08/18/2026 Smoke Detector 1st Floor Office Entry Tested 2:21:37 PM 08/18/2026 Smoke Detector 1st Floor Small Office by Garage Tested 3:09:28 PM 08/18/2026 Page of 9 14 Inspection & Testing Cape Cod Alarm Download Date: 08/20/2026 Device Type Location Service Time Date PASSED (continued) Initiating (continued) Smoke Detector 1st Floor Storage Closet Tested 2:20:23 PM 08/18/2026 Monitor Monitoring Alarm Signal Tested 2:13:07 PM 08/18/2026 FAILED/OTHER Initiating Heat Detector 1st Floor Front Left Office Restroom Tested 2:24:56 PM 08/18/2026 Heat Detector 1st Floor Garage (1st from Office)Tested 2:35:04 PM 08/18/2026 Heat Detector 1st Floor Garage (2nd from Office)Tested 2:25:06 PM 08/18/2026 Heat Detector 1st Floor Garage (far end)Tested 2:25:15 PM 08/18/2026 Heat Detector 1st Floor Garage above Office Tested 2:34:54 PM 08/18/2026 Heat Detector 1st Floor Hallway Restroom Tested 2:35:43 PM 08/18/2026 Page of 10 14 Service Summary Cape Cod Alarm Download Date: 08/20/2026 SERVICE SUMMARY Generated by: BuildingReports.com The Service Summary section provides an overview of the services performed in this report. Building: Cape Cod Mechanical Systems Device Type Service Quantity PASSED Battery, Sealed Lead Acid Tested 3 Communicator, Mesh Radio Network Tested 1 Control Panel, Conventional Tested 1 Heat Detector, Hardwire - Combination Tested 1 Horn/Strobe Tested 3 Monitoring, Alarm Signal Tested 1 Pull Station, Single Action Tested 2 Smoke Detector Tested 7 Total 19 FAILED/OTHER Heat Detector, Hardwire - Fixed Temperature Tested 4 Heat Detector, Hardwire - Combination Tested 2 Total 6 Grand Total 25 Page of 11 14 Sound and Visual Testing Cape Cod Alarm Download Date: 08/20/2026 SOUND AND VISUAL TESTING Generated by: BuildingReports.com The Sound and Visual Testing section lists various points throughout your building where audible and visual alarm notification devices were tested. Any bar-coded audible and visual devices will appear in the Inspection and Testing section of this report. Items in this section are grouped by Passed or Failed/Other. Where specific decibel readings were recorded, they will appear under the ambient and alarm columns. The Voice column indicates whether the Sound Test Point passed the Voice Intelligibility requirements. The STI or Sound Transmission Index is shown if recorded. Building: Cape Cod Mechanical Systems Audible/Visual Appliances Location Comment Ambient Alarm Synched ScanID PASSED Horn/Strobe 1st Floor Office Entry Passed ☐B9520009 1st Floor Garage Side Door Passed ☐B9520031 1st Floor Garage Restroom Passed ☐B9520042 Page of 12 14 Battery & Power Supply Testing Cape Cod Alarm Download Date: 08/20/2026 Control Panel: 1 - ESL 1503Building: Cape Cod Mechanical Systems BATTERY & POWER SUPPLY TESTING Generated by: BuildingReports.com The Battery & Power Supply Testing section details the readings and measurements of batteries and power supplies used to provide power to the fire alarm and life safety systems. Items are grouped by Passed or Failed/Other. Battery Type Location Rated Ah Rated Volts Pre Test Post Test Min Ah Teste d Ah MFG Date PASSED Sealed Lead Acid In AES Transmitter 5 12 90%80%01/04 /2024 Sealed Lead Acid In Fire Alarm Control Panel 7 12 100%100%08/18 /2026 Sealed Lead Acid In Fire Alarm Control Panel 7 12 100%100%08/18/2026 Page of 13 14 Inventory & Warranty Report Cape Cod Alarm Download Date: 08/20/2026 Control Panel: 1 - ESL 1503Building: Cape Cod Mechanical Systems INVENTORY & WARRANTY REPORT Generated by: BuildingReports.com The Inventory & Warranty Report lists each of the devices and items that are included in your Inspection Report. A complete inventory count by device type and category is provided. Items installed within the last 90 days, within the last year, and devices installed for two years or more are grouped together for easy reference. Building: Cape Cod Mechanical Systems Device or Type Category % of Inventory Quantity Battery Control 12.00%3 Communicator Control 4.00%1 Control Panel Control 4.00%1 Heat Detector Initiating 28.00%7 Horn/Strobe Indicating 12.00%3 Monitoring Monitor 4.00%1 Pull Station Initiating 8.00%2 Smoke Detector Initiating 28.00%7 Type Qty Model #Description Install Date NEW (UNDER 90 DAYS) AES Communicator 1 7058E Mesh Radio Network 08/18/2026 Power Patrol Battery 2 FAS1075 Sealed Lead Acid 08/18/2026 System Sensor Smoke Detector 2 2WB 08/18/2026 (manufacturer not specified) Monitoring 1 Alarm Signal 08/18/2026 IN SERVICE - 2 YEARS TO 3 YEARS Page of 14 14 Inventory & Warranty Report Cape Cod Alarm Download Date: 08/20/2026 Type Qty Model #Description Install Date IN SERVICE - 2 YEARS TO 3 YEARS (continued) Power Patrol Battery 1 FAS1055 Sealed Lead Acid 01/04/2024 IN SERVICE - 5 YEARS TO 10 YEARS System Sensor Heat Detector 1 5601P Hardwire - Combination 08/18/2020 IN SERVICE - 25 YEARS OR OLDER ESL Control Panel 1 1503 Conventional 08/18/2000 Smoke Detector 5 521BXT 08/18/2000 Edwards Heat Detector 2 281BPL Hardwire - Combination 08/18/2000 Heat Detector 4 284BPL Hardwire - Fixed Temperature 08/18/2000 Pull Station 2 270 Single Action 08/18/2000 Mircom Horn/Strobe 2 FHS-240R 08/18/2000 Siemens Horn/Strobe 1 MHU-MCS-RC 08/18/2000