Loading...
HomeMy WebLinkAboutSprinkler Inspection 20261 of 4 Sprinkler Inspection Certificate For BELLEW TILE AND MARBLE 280 ROUTE 28 WEST YARMOUTH, MA 02673 Tested to NFPA Standards This Inspection was performed in accordance with NFPA 25 Standards. The subsequent pages of this report provide performance measurements, listed ranges of acceptable results, and complete documentation of the inspection. Whenever discrepancies exist between acceptable performance standards and actual test results, notes and/or recommended solutions have been proposed or provided for immediate review and approval. Inspection Date: 7/30/2026 Inspector Name: Nick Narciso - T5 Title: Service Technician 2 of 4 Report of Inspection, Testing & Maintenance of Wet Pipe Pre-Action/Deluge/Dry Fire Sprinkler Systems (Weekly and monthly inspection tasks are NOT included in this report) Inspecting Firm: Fire Equipment Inc.Inspection Contract#:BELLEW TILE AND MARBLE - Child - Annual - 726 - Sprinkler Inspection Property Name: BELLEW TILE AND MARBLE Street: 280 ROUTE 28 City/State/Zip :WEST YARMOUTH,MA 02673 Inspection Frequency: Annual Inspector Name: Nick Narciso - T5 Date: 7/30/2026 Installed Product: WB 00084433 Product Name: Dry Sprinkler Equipment Location: Building Annual Testing for Wet Pipe/Deluge/Dry Sprinkler Systems System in service before testing Yes Pertinent parties notified before testing Yes Adequate drainage provided before flow testing Yes Hydraulic nameplate attached and legible with system identification signs Yes Alarm device free from physical damage Yes FDC is visible, accessible and undamaged with caps and autodrain in place Yes FDC automatic drain valve in place and operating properly Yes PRV in good condition N/A Priming water level tested (pre-action/deluge/dry)N/A Low air pressure alarms tested (pre-action/deluge/dry)Yes Forward flow test conducted at maximum rate possible Yes Static PSI 70 psi Residual PSI 65 psi Time for supply pressure to return to normal 5 sec Is there an Antifreeze loop? What area is protected by loop? Glycol_Freeze_Point_(degrees_F) Supervisory switch initiates distinct signal during first two hand wheel revolutions or before valve stem moved one-fifth from normal position Yes Signal restored only when valve returned to normal position Yes Water flow alarm tested and is operational Yes Test conducted with inspector’s test connection N/A Piping appears free of mechanical damage Yes Sprinklers appear free of paint Yes Sprinklers appear free of physical damage Yes Clearance appears to be adequate between sprinkler and building contents Yes 3 of 4 Spare sprinklers are of proper number (at least 6), type and temperature rating Yes Wrench available for each type of sprinkler Yes Sprinkler valve trip tested at full flow N/A Pressure reading at hydraulically most remote nozzle or sprinkler psi Pressure reading at the deluge valve psi Manual actuation device operated satisfactorily N/A Dry pipe valve trip tested with control valve partially open (required at full flow every 3 years)Yes Operating Stems of OS&Y (including backflow) valves lubricated N/A Valves completely closed and re-opened N/A Drain Test Conducted after control valves re-opened Automatic air pressure maintenance devices tested in accordance with mfg. inst.Yes System tagged and left in service Yes Pertinent parties notified after conclusion of maintenance Yes ALARM PANEL CLEAR N/A SYSTEM RETURNED TO SERVICE Yes Five Year Internal Completed On 7/30/2026 Next Five Year Inspection Due 7/30/2031 5yr Due Now No COMMENTS: 4 of 4 DEVICE SHEET Devices for Product: WB 00084433 Device Type Manufacturer Model Address Location Test Results Control Valve Kennedy 6” OS&Y City side backflow Pass Tamper_Switch Potter OSYSU-2 Zone 1 City side backflow control valve Pass Back Flow Preventor Conbraco 6” Model 6 DC Sprinkler room Pass Control Valve Kennedy 6” OS&Y System side backflow Pass Tamper_Switch Potter OSYSU-2 Zone 1 System side backflow control valve Pass Dry Pipe Valve Globe 6” Model G3 Sprinkler room Pass Low Air Switch System Sensor EPS40-1 Zone 1 Alarm valve Pass Pressure Switch Potter PS10-2A Zone 2 System waterflow Pass