Loading...
HomeMy WebLinkAbout2026 FIRE ALARM INSPECTION BUILDING REPORT2026 173 Route 6A LLC 173 Main Street Yarmouthport, MA 02675 (774)994-2149 Building Contact:Greg Bilezikian Title:Contact Company:Cape Cod Alarm Contact:Marty Crowell Title:Installer Fire Alarm Systems INSPECTIONCERTIFICATE Sep 8, 2026Inspection Date: Tested to NFPA 72 Standards This Inspection was performed in accordance with applicable NFPA Standards. The subsequent pages of this report provide performance measurements, listed ranges of acceptable results, and complete documentation of the inspection. Whenever discrepancies exist between acceptable performance standards and actual test results, notes and/or recommended solutions have been proposed or provided for immediate review and approval. Page of 2 10 Executive Summary Cape Cod Alarm Download Date: 09/10/2026 EXECUTIVE SUMMARY Generated by: BuildingReports.com Building Information 173 Route 6A LLC 173 Main Street Yarmouthport, MA 02675 United States of America Contact: Greg Bilezikian Phone: (781)987-3647 Fax: Mobile: Email: Inspection Performed By Cape Cod Alarm204 Old Townhouse RoadWest Yarmouth, MA 02673United States of America Inspector: Marty Crowell Phone: (508) 398-6316 Fax: Mobile: Email: service@capecodalarm.com System Control Unit Manufacturer: Silent Knight Inspection Date: 09/08/2026 IDC Style: E Model Number: 5208 Install Date: 09/04/2024 SLC Style: N/A Software Version:Version Date: 09/04/2024 NAC Style: E Location: Basement at bottom of the Stairs Disconnect Location:Disconnect Type: Current Protection: Breaker Monitoring Company: Cape Cod Alarm Phone: (508)398-6316 Account #: S27519 Central Station Signal Verification Type: Cellular Mfg: Napco Model #: SLE-LTEV-FIRE Test Time/Date: 9/8/26 3:12:26 PM Restore Time: 3:52 PM Note: Type of Signal Signal Confirmed Time Notes Trouble Signal 3:13 PM Alarm Signal 3:14 PM Page of 3 10 Executive Summary Cape Cod Alarm Download Date: 09/10/2026 Building: 173 Route 6A LLC Contact: Greg Bilezikian Company: Cape Cod Alarm Inspector: Marty Crowell Inspection Summary Category Total Items Serviced Passed Failed/Other Qty %Qty %Qty %Qty % Control 6 21.43%6 100.00%6 100.00%0 0.00% Indicating 7 25.00%7 100.00%7 100.00%0 0.00% Initiating 13 46.43%13 100.00%13 100.00%0 0.00% Monitor 2 7.14%2 100.00%2 100.00%0 0.00% Totals 28 100%28 100.00%28 100.00%0 0.00% Certification Page of 4 10 Inspection & Testing Cape Cod Alarm Download Date: 09/10/2026 Control Panel: 1 - Silent Knight 5208Building: 173 Route 6A LLC INSPECTION & TESTING Generated by: BuildingReports.com The Inspection & Testing section lists all of the items inspected in your building. Items are grouped by Passed or Failed/Other . Items are listed by Category. Each item includes the services performed, and the time & date at which testing occurred. Device Type Location Service Time Date PASSED Control Battery Basement in Fire Alarm Control Panel Tested 3:12:20 PM 09/08/2026 Battery Basement in Fire Alarm Control Panel Tested 3:12:21 PM 09/08/2026 Battery Basement in Fire Alarm Control Panel (for Power Supply)Tested 3:38:19 PM 09/08/2026 Communicator Basement at bottom of the Stairs Tested 3:12:26 PM 09/08/2026 Control Panel Basement at bottom of the Stairs Tested 3:12:25 PM 09/08/2026 Power Supply Basement in Fire Alarm Control Panel Tested 3:12:33 PM 09/08/2026 Indicating Horn/Strobe 1st Floor Kitchen Area by Rear Exit Tested 3:17:56 PM 09/08/2026 Horn/Strobe 1st Floor Retail Area Right Side Tested 3:20:14 PM 09/08/2026 Horn/Strobe 1st Floor Sitting Area Left Side Tested 3:22:33 PM 09/08/2026 Horn/Strobe 2nd Floor at top of Front Stairs Tested 3:21:24 PM 09/08/2026 Mini-Horn 2nd Floor Kitchen Tested 3:39:15 PM 09/08/2026 Mini-Horn Basement at bottom of the Stairs Tested 3:39:12 PM 09/08/2026 Strobe 1st Floor Restroom Tested 3:29:00 PM 09/08/2026 Initiating Heat Detector 1st Floor Kitchen Oven Area(Up High)Tested 3:38:56 PM 09/08/2026 Heat Detector 1st Floor Kitchen Prep Area Tested 3:17:00 PM 09/08/2026 Heat Detector 1st Floor Kitchen Prep Area by Coolers Tested 3:38:53 PM 09/08/2026 Page of 5 10 Inspection & Testing Cape Cod Alarm Download Date: 09/10/2026 Device Type Location Service Time Date PASSED (continued) Initiating (continued) Heat Detector 2nd Floor Hallway Tested 3:39:02 PM 09/08/2026 Pull Station 1st Floor Kitchen Area by Rear Exit Door Tested 3:17:58 PM 09/08/2026 Pull Station 1st Floor Retail Area Right Side Tested 3:20:22 PM 09/08/2026 Smoke Detector 1st Floor Retail Area Right Side Tested 3:20:09 PM 09/08/2026 Smoke Detector 1st Floor Sitting Area Left Side Tested 3:22:17 PM 09/08/2026 Smoke Detector 1st Floor at bottom of the Front Stairs Tested 3:21:01 PM 09/08/2026 Smoke Detector 2nd Floor at top of Front Stairs Tested 3:21:26 PM 09/08/2026 Smoke Detector 2nd Floor at top of Rear Stairs Tested 3:19:37 PM 09/08/2026 Smoke Detector Basement Storage Area Tested 3:16:00 PM 09/08/2026 Smoke Detector Basement at bottom of the Stairs Tested 3:12:39 PM 09/08/2026 Monitor Monitoring Alarm Signal Tested 3:12:26 PM 09/08/2026 Monitoring Trouble Signal Tested 3:12:27 PM 09/08/2026 Page of 6 10 Service Summary Cape Cod Alarm Download Date: 09/10/2026 SERVICE SUMMARY Generated by: BuildingReports.com The Service Summary section provides an overview of the services performed in this report. Building: 173 Route 6A LLC Device Type Service Quantity PASSED Battery, Sealed Lead Acid Tested 3 Communicator, Cellular Tested 1 Control Panel, Conventional Tested 1 Heat Detector, Combination Tested 3 Heat Detector, Fixed Temperature Tested 1 Horn/Strobe Tested 4 Mini-Horn Tested 2 Monitoring, Trouble Signal Tested 1 Monitoring, Alarm Signal Tested 1 Power Supply Tested 1 Pull Station, Dual Action Tested 2 Smoke Detector Tested 7 Strobe Tested 1 Total 28 Grand Total 28 Page of 7 10 Sound and Visual Testing Cape Cod Alarm Download Date: 09/10/2026 SOUND AND VISUAL TESTING Generated by: BuildingReports.com The Sound and Visual Testing section lists various points throughout your building where audible and visual alarm notification devices were tested. Any bar-coded audible and visual devices will appear in the Inspection and Testing section of this report. Items in this section are grouped by Passed or Failed/Other. Where specific decibel readings were recorded, they will appear under the ambient and alarm columns. The Voice column indicates whether the Sound Test Point passed the Voice Intelligibility requirements. The STI or Sound Transmission Index is shown if recorded. Building: 173 Route 6A LLC Audible/Visual Appliances Location Comment Ambient Alarm Synched ScanID PASSED Horn/Strobe 1st Floor Sitting Area Left Side Passed ☐98926083 1st Floor Retail Area Right Side Passed ☐98926149 1st Floor Kitchen Area by Rear Exit Passed ☐98926157 2nd Floor at top of Front Stairs Passed ☐98926159 Strobe 1st Floor Restroom Passed ☐98926079 Page of 8 10 Battery & Power Supply Testing Cape Cod Alarm Download Date: 09/10/2026 Control Panel: 1 - Silent Knight 5208Building: 173 Route 6A LLC BATTERY & POWER SUPPLY TESTING Generated by: BuildingReports.com The Battery & Power Supply Testing section details the readings and measurements of batteries and power supplies used to provide power to the fire alarm and life safety systems. Items are grouped by Passed or Failed/Other. Battery Type Location Rated Ah Rated Volts Pre Test Post Test Min Ah Teste d Ah MFG Date PASSED Sealed Lead Acid Basement in Fire Alarm Control Panel 7 12 100 80 09/04 /2024 Sealed Lead Acid Basement in Fire Alarm Control Panel 7 12 100 80 09/04 /2024 Sealed Lead Acid Basement in Fire Alarm Control Panel (for Power Supply)7 12 100 80 09/04/2024 Page of 9 10 Inventory & Warranty Report Cape Cod Alarm Download Date: 09/10/2026 Control Panel: 1 - Silent Knight 5208Building: 173 Route 6A LLC INVENTORY & WARRANTY REPORT Generated by: BuildingReports.com The Inventory & Warranty Report lists each of the devices and items that are included in your Inspection Report. A complete inventory count by device type and category is provided. Items installed within the last 90 days, within the last year, and devices installed for two years or more are grouped together for easy reference. Building: 173 Route 6A LLC Device or Type Category % of Inventory Quantity Battery Control 10.71%3 Communicator Control 3.57%1 Control Panel Control 3.57%1 Heat Detector Initiating 14.29%4 Horn/Strobe Indicating 14.29%4 Mini-Horn Indicating 7.14%2 Monitoring Monitor 7.14%2 Power Supply Control 3.57%1 Pull Station Initiating 7.14%2 Smoke Detector Initiating 25.00%7 Strobe Indicating 3.57%1 Type Qty Model #Description Install Date IN SERVICE - 2 YEARS TO 3 YEARS Elk Power Supply 1 624 09/04/2024 Gentex Mini-Horn 2 MHW 09/04/2024 Napco Communicator 1 SLE-LTEV-FIRE Cellular 09/04/2024 Page of 10 10 Inventory & Warranty Report Cape Cod Alarm Download Date: 09/10/2026 Type Qty Model #Description Install Date IN SERVICE - 2 YEARS TO 3 YEARS (continued) Power Patrol Battery 1 FAS1055 Sealed Lead Acid 09/04/2024 Battery 2 FAS1075 Sealed Lead Acid 09/04/2024 Silent Knight Control Panel 1 5208 Conventional 09/04/2024 Pull Station 2 PS-DATK Dual Action 09/04/2024 System Sensor Horn/Strobe 3 P2R 09/04/2024 Horn/Strobe 1 PC2WL 09/04/2024 Smoke Detector 7 2WT-B 09/04/2024 Strobe 1 SR 09/04/2024 (manufacturer not specified) Monitoring 1 Alarm Signal 09/04/2024 Monitoring 1 Trouble Signal 09/04/2024 IN SERVICE - 5 YEARS TO 10 YEARS System Sensor Heat Detector 3 5601P Combination 09/04/2019 Heat Detector 1 5604 Fixed Temperature 09/04/2019