Loading...
HomeMy WebLinkAboutQuarterly Inspection Sep 2026Report of Inspection / Test Quarterly NFPA 25 *Ai"TJfiD -J:*L?f-S* 09-0$,2026 Property Supply New England 269109 28 Aaron Way West Yarmoulh l\,,1A 02673 Jason Sidok 18003379469 Print Date: 0910-2026 Conducted by: Mike Mennella License Sprinkler Fitter Allied Fire Prolection lnspection Services lnc. 108 Pond Street West Wanvick Rhode lsland 02893 40't-828-2600 insp€ctions@alliedfi re.us OWNER SECTION ls fre building occupied?g tr tr Yqs No NA El Yes trNo trNA Are all llre protecilon systems in service?E Yes E tto DNA Has th€ system remained in service without modificatjon since the last inspection?D t'to ONA Was the systom free ofactuations of devices o. alarms sinc€ the last inspection? E Yes ENo DNA FIRE DEPARTMENT CONNECTION E Yes DNo E] NA ls the FDC easily accessible?E Yes DNo ONA ls the FOC check valve drip free?E Yes B tto trNA ls the clapper and automatic drain valve in place and properly operating? E] D D Yes No NA ls the FDC identitication sign(s)in place?E Yes DNo ONA Has the five year FOC hydrostatic test been completed? VALVE AREA Are the control valves (including backflov/ preventer isolation valves) supervised with seals locked or is supervision in dace? O Yes ENo ENA Are the control valves (including backiow preventer isolation valves) supervised with seals free from leaks? A Yes ENo trNA Are the control valves (including valves on backfow preventers) with locks or electrical supervision in correct (open or closed) position? E Yes D t'to DNA Are the control valves (including valves on backllow prev€nlers) with locks or electrical supervision locksd or is supervision in place? E Yes E t'to DNA Are the contrd valves (including valves on backiovr prevenlers) with locks or electrical supervision have the appropriate wrenches? O Yes ENo E]NA Are all check \lalves externally inspected, operating properly. and are in good condition? E Yes ENo trNA Are the gauges on system n good condition and showing normal waler supply pressure? I Yes ENo DNA The electrical waterflow alarm devices passed test by opening inspectols test connection/bypass connection with alarms actuating and flow observed? B Yes ONo ONA ALARMS E) Yes D r,io f] NA Are alarms and supervisory devices not damaged?ls the ala.m valve free from physical damage?E Yes ENo trNA Copyrioht 2026 lnspect Point Page 1 of 5 Report of lnspection / Test Genera! Questions Has the occupancy dassification and hazard ofcontents remained the same since the last inspection? ls the FDC plainly visible? g Yes ONo DNA 09-09-2026 Property Supply New England 269109 28 Aaron Way West Yarmouth MA 02673 Jason Sidok 18003379469 Print Date: 0$10-2026 Allied Fire Protection lnspection Services lnc. 108 Pond Street West Warwick Rhode lsland 02893 401-828-2600 inspections@alliedfi re.us Report of lnspection / Test Quartedy NFPA 25 Wry-'-r,il; Conducted by: Mike Mennella License Sprinkler Fitter ls the trim in correct (open or closed) position?g D tr Yes No NA Have adjusted, repaired, reconditioned, or replaced components had proper tests/ihspections perforrned? EI Yes E) No ONA Has the lnternal Pipe inspeclion been done in the past 5 years? E tr tr Yes No NA Copyrighl 2026 lnspect Point Page 2 of 5 MAINTENANCE 5 YEAR 09-09-2026 Property Supply New England 269109 28 Aaron Way West Yarmouth lVlA 02673 Jason Sidok'18003379469 Print Date: 0$10-2026 Report of lnspection / Test S*wry Conducted by: l\,like Mennella Licanse Sprinkler Fitter MAIN DRAIN FLOW TESTS System lnitial Static Residual Static Flow Observed?Did walerflow alarm operate? N/A N/A Yes Yes 4 'shotgun. Riser and flow 64 50 62 Yes Yes VALVES (weo E.sily Si9ns Uales d Ellr. supply B!nerny B!tlsrlly DRAIN VALVES 1we0 Wal.r Flow Ob6.tu.d Copyright 2026 lnspect Point Allied Fire Protection lnspection Services lnc. 108 Pond Street West Warwick Rhode lsland 02893 40'l-828-2600 inspections@alliedfi re. us Quarterly NFPA 25 Page 3 of 5 09-09.2026 Property Supply New England 269109 28 Aaron Way Wesl Yarmouth MA 02673 Jason Sidok 18003379469 Print Date: 0910-2026 Allied Fire Protection lnspection Services lnc. 108 Pond Street Wesl WaMick Rhode lsland 02893 401-82&2600 inspections@alliedfi re.us Report of lnspection / Test Quarterly NFPA 25 1:.*- -r: Sdr Conducted by: [Iike Mennella License Sprinkler Fitter None None None None None None Copyright 2026 lnspect Point Page 4 of 5 Deficiencies - General Ouestions Deficiencies - General lryet System Questions Deficiencies - " Deficiencies - 4 " shotgun. Riser and floly Deficiencies - Valves Deficiencies - Drain Valves 09-0$,2026 Property Supdy New England 269109 28 Aaron Way West Yarmouth l\,4A 02673 Jason Sidok 18003379469 Print Date: 0*10-2026 Allied Fire Protection lnspection Services lnc. 108 Pond Street West Warwick Rhode lsland 02893 401-828-2600 inspections@alliedfi re. us Report of lnspection / Test _wry_,,ffiQuarterly NFPA 25 Conducted by: Mike Mennella License Sprinkler Fitter I state that the information on this rorm is conect at the time and dace of my inspection, and all equipment lested at this time was left in operational condition r]pon completion of this inspection except as noled. Date Completedlhspeclot Name Signature 202G0$'10Mike Mennella License Sprinkler Fitter Copyright 2026 lnspect Point Page 5 of 5 lnspector Signature r\ 01