Loading...
HomeMy WebLinkAbout2026 FIRE ALARM INSPECTION BUILDING REPORT2026 Charles White Management 6 Beatrice Lane West Yarmouth, MA 02673 (508)889-1445 Building Contact:George Deraleau Title:Contact Company:Cape Cod Alarm Contact:Marty Crowell Title:Installer Fire Alarm Systems INSPECTIONCERTIFICATE Sep 21, 2026Inspection Date: Tested to NFPA 72 Standards This Inspection was performed in accordance with applicable NFPA Standards. The subsequent pages of this report provide performance measurements, listed ranges of acceptable results, and complete documentation of the inspection. Whenever discrepancies exist between acceptable performance standards and actual test results, notes and/or recommended solutions have been proposed or provided for immediate review and approval. Page of 2 8 Executive Summary Cape Cod Alarm Download Date: 09/25/2026 EXECUTIVE SUMMARY Generated by: BuildingReports.com Building Information Charles White Management 6 Beatrice Lane West Yarmouth, MA 02673 United States of America Contact: George Deraleau Phone: (508)889-1445 Fax: Mobile: Email: Inspection Performed By Cape Cod Alarm204 Old Townhouse RoadWest Yarmouth, MA 02673United States of America Inspector: Marty Crowell Phone: (508) 398-6316 Fax: Mobile: Email: service@capecodalarm.com System Control Unit Manufacturer: Silent Knight Inspection Date: 09/21/2026 IDC Style: E Model Number: SK-4 Install Date: 06/01/2017 SLC Style: N/A Software Version:Version Date: 05/06/2022 NAC Style: e Location: 1st Floor Utility Closet Disconnect Location:Disconnect Type: Current Protection: Breaker Monitoring Company: Cape Cod Alarm Phone: (508)398-6316 Account #: S24798 Central Station Signal Verification Type: Mesh Radio Network Mfg: AES Model #: 7788F Test Time/Date: 9/21/26 12:48:13 PM Restore Time: 12:53 PM Note: Type of Signal Signal Confirmed Time Notes Alarm Signal 12:47 PM Trouble Signal Page of 3 8 Executive Summary Cape Cod Alarm Download Date: 09/25/2026 Building: Charles White Management Contact: George Deraleau Company: Cape Cod Alarm Inspector: Marty Crowell Type of Signal (continued)Signal Confirmed Time Notes Supervisory Signal 12:48 PM Inspection Summary Category Total Items Serviced Passed Failed/Other Qty %Qty %Qty %Qty % Control 5 41.67%5 100.00%5 100.00%0 0.00% Indicating 1 8.33%1 100.00%1 100.00%0 0.00% Initiating 1 8.33%1 100.00%1 100.00%0 0.00% Monitor 3 25.00%3 100.00%3 100.00%0 0.00% Supervisory 2 16.67%2 100.00%2 100.00%0 0.00% Totals 12 100%12 100.00%12 100.00%0 0.00% Certification Page of 4 8 Inspection & Testing Cape Cod Alarm Download Date: 09/25/2026 Control Panel: 1 - Silent Knight SK-4Building: Charles White Management INSPECTION & TESTING Generated by: BuildingReports.com The Inspection & Testing section lists all of the items inspected in your building. Items are grouped by Passed or Failed/Other . Items are listed by Category. Each item includes the services performed, and the time & date at which testing occurred. Device Type Location Service Time Date PASSED Control Battery 1st Floor Utility Closet inside AES Tested 12:48:09 PM 09/21/2026 Battery 1st Floor Utility Closet inside FACP Tested 12:47:04 PM 09/21/2026 Battery 1st Floor Utility Closet inside FACP Tested 12:47:05 PM 09/21/2026 Communicator 1st Floor Utility Closet Tested 12:48:13 PM 09/21/2026 Control Panel 1st Floor Utility Closet Tested 12:47:18 PM 09/21/2026 Indicating Beacon Outside of Unit (Up High)Tested 12:47:17 PM 09/21/2026 Initiating Waterflow Switch 1st Floor Utility Closet Tested 12:47:21 PM 09/21/2026 Monitor Monitoring Alarm Signal Tested 12:48:10 PM 09/21/2026 Monitoring Supervisory Signal Tested 12:48:12 PM 09/21/2026 Monitoring Trouble Signal Tested 12:48:11 PM 09/21/2026 Supervisory Tamper Switch 1st Floor Utility Closet Tested 12:47:22 PM 09/21/2026 Tamper Switch 1st Floor Utility Closet Tested 12:47:25 PM 09/21/2026 Page of 5 8 Service Summary Cape Cod Alarm Download Date: 09/25/2026 SERVICE SUMMARY Generated by: BuildingReports.com The Service Summary section provides an overview of the services performed in this report. Building: Charles White Management Device Type Service Quantity PASSED Battery, Sealed Lead Acid Tested 3 Beacon Tested 1 Communicator, Mesh Radio Network Tested 1 Control Panel, Conventional Tested 1 Monitoring, Alarm Signal Tested 1 Monitoring, Trouble Signal Tested 1 Monitoring, Supervisory Signal Tested 1 Tamper Switch Tested 2 Waterflow Switch Tested 1 Total 12 Grand Total 12 Page of 6 8 Battery & Power Supply Testing Cape Cod Alarm Download Date: 09/25/2026 Control Panel: 1 - Silent Knight SK-4Building: Charles White Management BATTERY & POWER SUPPLY TESTING Generated by: BuildingReports.com The Battery & Power Supply Testing section details the readings and measurements of batteries and power supplies used to provide power to the fire alarm and life safety systems. Items are grouped by Passed or Failed/Other. Battery Type Location Rated Ah Rated Volts Pre Test Post Test Min Ah Teste d Ah MFG Date PASSED Sealed Lead Acid 1st Floor Utility Closet inside AES 7 12 100 80 04/16 /2024 Sealed Lead Acid 1st Floor Utility Closet inside FACP 7 12 100 80 04/16 /2024 Sealed Lead Acid 1st Floor Utility Closet inside FACP 7 12 100 90 04/16/2024 Page of 7 8 Inventory & Warranty Report Cape Cod Alarm Download Date: 09/25/2026 Control Panel: 1 - Silent Knight SK-4Building: Charles White Management INVENTORY & WARRANTY REPORT Generated by: BuildingReports.com The Inventory & Warranty Report lists each of the devices and items that are included in your Inspection Report. A complete inventory count by device type and category is provided. Items installed within the last 90 days, within the last year, and devices installed for two years or more are grouped together for easy reference. Building: Charles White Management Device or Type Category % of Inventory Quantity Battery Control 25.00%3 Beacon Indicating 8.33%1 Communicator Control 8.33%1 Control Panel Control 8.33%1 Monitoring Monitor 25.00%3 Tamper Switch Supervisory 16.67%2 Waterflow Switch Initiating 8.33%1 Type Qty Model #Description Install Date IN SERVICE - 2 YEARS TO 3 YEARS Power Patrol Battery 3 FAS1075 Sealed Lead Acid 04/16/2024 IN SERVICE - 5 YEARS TO 10 YEARS AES Communicator 1 7788F Mesh Radio Network 05/01/2017 Edwards Beacon 1 06/01/2017 Landsdale Tamper Switch 2 05/01/2017 Silent Knight Page of 8 8 Inventory & Warranty Report Cape Cod Alarm Download Date: 09/25/2026 Type Qty Model #Description Install Date IN SERVICE - 5 YEARS TO 10 YEARS (continued) Silent Knight (continued) Control Panel 1 SK-4 Conventional 06/01/2017 System Sensor Waterflow Switch 1 WFDT 05/01/2017 (manufacturer not specified) Monitoring 1 Alarm Signal 05/01/2017 Monitoring 1 Supervisory Signal 05/01/2017 Monitoring 1 Trouble Signal 05/01/2017