HomeMy WebLinkAbout55 Circuit Rd North Inspection ReportTown of Yarmouth, MA
Inspection Report
Inspection: Inspection
Inspector: Brian Coughlin
Inspection Date: Oct 1, 2026
Record: Rental Registration #BHR-26-316
Location: 55 &57 CIRCUIT RD NORTH, WEST YARMOUTH, MA 02673
Applicant: William Kennedy
Rental Inspection
Overall Result: Pass
Overall Remarks:
#55 - Met with occupant for inspection. Unit is in decent
condition and well maintained by occupant.
Checklist:
1.
Number of Bedrooms/Measurements
Result: Pass
Remarks:
1) 10'1" x 10'1", 2) 7'6" x 9'11"
2.
Maximum Occupancy: Based on septic system capacity,
number of bedrooms and bedroom square footage
Result: Pass
Remarks:
3
3.
Basement
Result: Not Observed
Remarks:
N/A
4.
Electrical Panel
Result: Pass
5.
A copy of Notice of Occupant's Legal Rights and
Responsibilities has been issued to occupant.
Result: Pass
105CMR 410.00 0Minimum Standards of Fitness
for Human Habitation
(State Sanitary Code: Chapter II)
Result: Pass
410.100 Kitchen Facilities
*
Result: Pass
410.110 Bathroom Facilities : Sinks, Toilets, Tubs
& Showers
*
Result: Pass
410.120 Approved Toilets
*
Result: Pass
410.130 Water supply
Potable Water/Sanitary Drainage
Result: Pass
410.140 Plumbing Connections
*
Result: Pass
410.150 Hot Water
110-130 °F for faucets & 110-120 °F for bathtubs & showers
Result: Pass
410.160 Heating Systems
*
Result: Pass
410.170 Venting
*
Result: Pass
410.180 Temperature Requirements
Owner shall proved heat in every habitable room & every room
containing a toilet, shower or bathtub from September 15th
through May 31st. 64° from 11:01 pm to 6:59 am 68° from 7 am
to 11:00 pm
Result: Pass
410.200 Provision and Metering of Electrical or
Gas
*
Result: Pass
410.210 Provision of Oil
*
Result: Not Observed
410.220 Natural and Mechanical Ventilation
*
Result: Pass
410.230 Owner's Laundering Responsibilities
If owner provides bed linens, towels, pillows or mattress
Result: Not Observed
410.235 Owner's Installation, Maintenance and
Repair Responsibilities
*
Result: Fail
Remarks:
- Rear door rusting out and needs replacement. 410.530:
Weather-tight Elements (A) An exterior openable window
shall be considered weathertight only when: (1) All panes of
glass are in place, unbroken and properly sealed; (2) (3) The
window sash opens and closes fully without excessive effort;
and One of the following conditions is met: 410.530:
continued 105 CMR: DEPARTMENT OF PUBLIC HEALTH (a) The
window sash is sufficiently well-fitted such that it minimizes
the infiltration of air or moisture and the space between the
window sash and the prime window frame is no larger than c
inch at any point on the perimeter of the sash in the case of
double hung windows and 1/16 inch in the case of casement
windows; or (b) A storm window is affixed to the prime
window frame in such a way as to minimize the infiltration of
air or moisture. (B) A door leading from a residence or
dwelling unit to the exterior shall be considered to be
weathertight only if: (1) (2) (3) All panes of glass are in place,
unbroken and properly sealed; The door opens and closes
fully without excessive effort; and One of the following
conditions is met: (a) The door is sufficiently well-fitted so
that it minimizes the infiltration of air or moisture and the
space between the door and the prime door frame is no
larger than c inch at any point on the sides of the door; or (b)
storm door is affixed to the prime door frame in such a way
as to minimize the infiltration of air or moisture. (C) Building
and structural elements shall be considered weather-tight
when all cracks and spaces not part of heating, ventilating, or
air conditioning systems are sealed to prevent infiltration of
exterior air or moisture.
410.240 Occupant's Installation and
Maintenance Responsibilities
*
Result: Pass
410.250 Asbestos-containing Material
*
Result: Pass
410.260 Means of Egress
*
Result: Pass
410.270 Locks
*
Result: Pass
410.300 Electrical Supply & Illumination
*
Result: Pass
410.310 Auxiliary Emergency Lighting Systems
& Exit Signs
For properties with 10 or more units
Result: Not Observed
410.320 Electrical Service
Temporary Wiring, Amperage
Result: Pass
410.330 Smoke Detector and Carbon Monoxide
Alarms
*
Result: Pass
Remarks:
Tested and working
410.400 Owner/Manager Contact Information
and Notice of Occupants' Legal Rights and
Responsibilities
Contact information and postings inside and outside of home
Result: Pass
410.410 Building Identification
*
Result: Pass
410.420
Habitability Requirements
Result: Pass
410.430 Natural Light and Obstructions
*
Result: Pass
410.470 Lead-based Paint Hazards in Residence
*
Result: Pass
Remarks:
None observed
410.500 Owner Responsibility to Maintain
Building & Structural Elements
*
Result: Pass
410.510 Occupant 's Responsibility Regarding
Building and Structural Elements
*
Result: Pass
410.520 Protective Railings and Walls
*
Result: Pass
410.530 Weather-tight elements
*
Result: Pass
410.540 Installation of Screens
*
Result: Fail
Remarks:
Doors need screen doors, some windows missing screens.
410.540: Installation of Screens (A) The owner shall provide
and install screens for exterior openable windows so that: (1)
They are in place during the period from April 1st through
October 31st in each year; (2) (3) They are no less than 16
mesh per square inch; They cover that part of the window
designed to be opened, except in double hung windows
where half screens shall meet this requirement; and (4) They
are tight fitting and prevent the entrance of pests. (B)
Expandable, temporary screens shall not satisfy the
requirements of 105 CMR 410.540(A). (C) The owner shall
provide and install screen doors for all doorways opening
directly to the outside from any dwelling unit or rooming unit
where the screen doors will be permitted to slide to the side
or open in an outward direction so that: (1) They are in place
during the period from April 1st through October 31st in each
year; (2) They are 16 mesh per square inch; (3) They are
equipped with a self-closing device except where the screen
is designed to open to the side; and (4) (D) They are tight
fitting and prevent the entrance of pests. 105 CMR
410.540(C) shall not apply to homeless shelters.
410.550 Elimination of Pests
Owners & Occupants are responsible for the control &
elimination of pests
Result: Pass
Remarks:
None observed
410.560 Refuse
*
Result: Pass
410.570 Maintenance of Areas in a Sanitary and
Safe Condition
*
Result: Pass
410.620 Conduct of Inspections
The need for an additional inspection by a specialized
inspector pursuant to 105 CMR 410.620(A) and the reason that
such inspection is necessary
Result: Pass
410.630 Conditions Deemed to Endanger or
Materially Impair Health and Safety
One or more of the violations cited on this report may
materially impair the health or safety and/or well-being of any
person(s) occupying the premises
Result: Pass
780 CMR 111.5.1 Posting of Use & Occupancy
STR Only
Result: Not Observed
780 CMR 111.5.2 Required Egress posting
STR Only
Result: Not Observed
780 CMR Means of Egress
STR Only
Result: Not Observed
780 CMR R314 & R315 Smoke/CO/Heat
STR Only
Result: Not Observed
This inspection report is signed and certified
under the pains and penalties of perjury.
Inspector's signature, date and time
Result: Pass
Remarks:
Brian Coughlin 10/1/26 10:00 am