HomeMy WebLinkAbout2026 FIRE ALARM INSPECTION BUILDING REPORT (2)2026 Sunflower Marketplace - Building 1 923 Route 6A Yarmouthport, MA 02675 (508)362-5439 Building Contact:Nancy Basler Title:Contact Company:Cape Cod Alarm Contact:Chad Benaka Title:Service Tech Fire Alarm Systems INSPECTIONCERTIFICATE Oct 13, 2026Inspection Date: Tested to NFPA 72 Standards This Inspection was performed in accordance with applicable NFPA Standards. The subsequent pages of this report provide performance measurements, listed ranges of acceptable results, and complete documentation of the inspection. Whenever discrepancies exist between acceptable performance standards and actual test results, notes and/or recommended solutions have been proposed or provided for immediate review and approval. Page of 2 14 Executive Summary Cape Cod Alarm Download Date: 10/15/2026 EXECUTIVE SUMMARY Generated by: BuildingReports.com Building Information Sunflower Marketplace - Building 1 923 Route 6A Yarmouthport, MA 02675 United States of America Contact: Nancy Basler Phone: (508)367-6991 Fax: Mobile: Email: Inspection Performed By Cape Cod Alarm204 Old Townhouse RoadWest Yarmouth, MA 02673United States of America Inspector: Chad Benaka Phone: (508) 398-6316 Fax: Mobile: Email: service@capecodalarm.com System Control Unit Manufacturer: Notifier Inspection Date: 10/13/2026 IDC Style: E Model Number: SFP-40B Install Date: 11/13/2024 SLC Style: N/A Software Version:Version Date: 12/31/1969 NAC Style: E Location: 1st Floor Building 1 Unit D Entry Foyer Disconnect Location:Disconnect Type: Current Protection: Breaker Monitoring Company: Cape Cod Alarm Phone:Account #: S24993 Central Station Signal Verification Type: Mesh Radio Network Mfg: AES Model #: 7788F Test Time/Date: 10/13/26 12:58:36 PM Restore Time: 1:52 PM Note: Type of Signal Signal Confirmed Time Notes Trouble Signal 12:47 PM Alarm Signal 1:26 PM Page of 3 14 Executive Summary Cape Cod Alarm Download Date: 10/15/2026 Building: Sunflower Marketplace - Building 1 Contact: Nancy Basler Company: Cape Cod Alarm Inspector: Chad Benaka Inspection Summary Category Total Items Serviced Passed Failed/Other Qty %Qty %Qty %Qty % Control 5 19.23%5 100.00%5 100.00%0 0.00% Indicating 5 19.23%5 100.00%5 100.00%0 0.00% Initiating 14 53.85%14 100.00%5 35.71%9 64.29% Monitor 2 7.69%2 100.00%2 100.00%0 0.00% Totals 26 100%26 100.00%17 65.38%9 34.62% Certification Page of 4 14 Discrepancy Report Cape Cod Alarm Download Date: 10/15/2026 Control Panel: 1 - Notifier SFP-40BBuilding: Sunflower Marketplace - Building 1 DISCREPANCY REPORT Deficiency, Impairment, and Observation Generated by: BuildingReports.com The Discrepancy Report consolidates each discrepancy listed within the various Testing sections of your Inspection. Discrepancies are listed by Category, and grouped by device type. The description of the problem is provided and where appropriate, code references are listed for your convenience. Any item that was inspected that is subject to a recall or part of a manufacturer's replacement/upgrade program is included. This section is now enhanced by BuildingReports AI, which helps refine applicable manufacturer recalls and replacement notices, enabling service providers and facilities to address potential issues more quickly. Building: Sunflower Marketplace - Building 1 Items listed for Recall or Replacement/Upgrade Device Type Manufacturer Model Number Date Qty No recalled items found during this inspection. Discrepancies ScanID Location Problem Address Reference INITIATING Heat Detector B9520972 1st Floor Building 1 Unit A Back Room Date Expired 1 NFPA72 Table 14.4.3.2 (17)(4)(c) B9520971 1st Floor Building 1 Unit A Entry Area Date Expired 1 NFPA72 Table 14.4.3.2 (17)(4)(c) B9520959 1st Floor Building 1 Unit B Entry Area Date Expired 1 NFPA72 Table 14.4.3.2 (17)(4)(c) B9521063 1st Floor Building 1 Unit C Entry Area Date Expired 1 NFPA72 Table 14.4.3.2 (17)(4)(c) B9521064 1st Floor Building 1 Unit C Front Left Office Date Expired 1 NFPA72 Table 14.4.3.2 (17)(4)(c) Page of 5 14 Discrepancy Report Cape Cod Alarm Download Date: 10/15/2026 ScanID Location Problem Address Reference INITIATING (continued) Heat Detector (continued) B9521062 1st Floor Building 1 Unit C Rear Left Office Date Expired 1 NFPA72 Table 14.4.3.2 (17)(4)(c) B9520970 1st Floor Building 1 Unit D Entry Area Date Expired 1 NFPA72 Table 14.4.3.2 (17)(4)(c) B9520967 1st Floor Building 1 Unit D Entry Areaby Reception Date Expired 1 NFPA72 Table 14.4.3.2 (17)(4)(c) B9520974 1st Floor Building 1 Unit D Repair Shop Date Expired 1 NFPA72 Table 14.4.3.2 (17)(4)(c) Code References NFPA72 Table 14.4.3.2 (17)(4)(c)After 15 years from initial installation, replace all devices or have 2 detectors per 100 laboratory tested. Page of 6 14 Proposed Solutions Report Cape Cod Alarm Download Date: 10/15/2026 Control Panel: 1 - Notifier SFP-40BBuilding: Sunflower Marketplace - Building 1 PROPOSED SOLUTIONS REPORT Generated by: BuildingReports.com The Proposed Solution Report provides a solution for each discrepancy listed on the Discrepancy Report. Provide a check mark where indicated to approve repairs listed within the report. Items listed as T/M are available for repair on a Time and Materials basis. ScanID Location Solution Model #Cost Fixed Date INITIATING Heat Detector B9520972 1st Floor Building 1 Unit A Back Room Replace 281BPL T/M B9520971 1st Floor Building 1 Unit A Entry Area Replace 281BPL T/M B9520959 1st Floor Building 1 Unit B Entry Area Replace 281BPL T/M B9521063 1st Floor Building 1 Unit C Entry Area Replace 281BPL T/M B9521064 1st Floor Building 1 Unit C Front Left Office Replace 281BPL T/M B9521062 1st Floor Building 1 Unit C Rear Left Office Replace 281BPL T/M B9520970 1st Floor Building 1 Unit D Entry Area Replace 281BPL T/M B9520967 1st Floor Building 1 Unit D Entry Areaby Reception Replace 281BPL T/M B9520974 1st Floor Building 1 Unit D Repair Shop Replace 281BPL T/M Customer WO/PO #:(none)Internal WO/PO #:(none)Total: T/M Page of 7 14 Notes & Recommendations Cape Cod Alarm Download Date: 10/15/2026 NOTES & RECOMMENDATIONS Generated by: BuildingReports.com The Notes & Recommendations Report details additional inspection notes made by the Inspectors during the course of the building inspection. Notes are grouped by Category. General Note No audible sound in Unit A, Page of 8 14 Inspection & Testing Cape Cod Alarm Download Date: 10/15/2026 Control Panel: 1 - Notifier SFP-40BBuilding: Sunflower Marketplace - Building 1 INSPECTION & TESTING Generated by: BuildingReports.com The Inspection & Testing section lists all of the items inspected in your building. Items are grouped by Passed or Failed/Other . Items are listed by Category. Each item includes the services performed, and the time & date at which testing occurred. Device Type Location Service Time Date PASSED Control Battery In AES Trasnmitter Tested 1:00:03 PM 10/13/2026 Battery In Fire Alaem Control Panel Tested 1:40:45 PM 10/13/2026 Battery In Fire Alarm Control Panel Tested 1:40:49 PM 10/13/2026 Communicator Attic above Fire Alarm Control Panel Tested 12:58:36 PM 10/13/2026 Control Panel 1st Floor Building 1 Unit D Entry Foyer Tested 1:06:26 PM 10/13/2026 Indicating Horn/Strobe 1st Floor Building 1 Unit B Entry Foyer Tested 1:23:20 PM 10/13/2026 Horn/Strobe 1st Floor Building 1 Unit C Entry Foyer Tested 1:32:16 PM 10/13/2026 Horn/Strobe 1st Floor Building 1 Unit D Entry Foyer Tested 1:08:00 PM 10/13/2026 Horn/Strobe 1st Floor Building 1 Unit E Entry Foyer Tested 1:17:57 PM 10/13/2026 Strobe Outside Building 1 Unit D Tested 1:07:26 PM 10/13/2026 Initiating Heat Detector 1st Floor Building 1 Unit D Entry Area Tested 1:11:10 PM 10/13/2026 Pull Station 1st Floor Building 1 Unit D Entry Foyer Tested 1:09:46 PM 10/13/2026 Smoke Detector 1st Floor Building 1 Unit D Entry Foyer Tested 1:10:42 PM 10/13/2026 Smoke Detector 1st Floor Building 1 Unit D Repair Shop Tested 1:16:01 PM 10/13/2026 Smoke Detector 1st Floor Building 1 Unit D Smoke by door to Back Room Tested 1:13:16 PM 10/13/2026 Monitor Monitoring Alarm Signal Tested 12:59:24 PM 10/13/2026 Page of 9 14 Inspection & Testing Cape Cod Alarm Download Date: 10/15/2026 Device Type Location Service Time Date PASSED (continued) Monitor (continued) Monitoring Trouble Signal Tested 12:59:50 PM 10/13/2026 FAILED/OTHER Initiating Heat Detector 1st Floor Building 1 Unit A Back Room Tested 1:21:11 PM 10/13/2026 Heat Detector 1st Floor Building 1 Unit A Entry Area Tested 1:20:30 PM 10/13/2026 Heat Detector 1st Floor Building 1 Unit B Entry Area Tested 1:23:33 PM 10/13/2026 Heat Detector 1st Floor Building 1 Unit C Entry Area Tested 1:35:05 PM 10/13/2026 Heat Detector 1st Floor Building 1 Unit C Front Left Office Tested 1:34:28 PM 10/13/2026 Heat Detector 1st Floor Building 1 Unit C Rear Left Office Tested 1:35:59 PM 10/13/2026 Heat Detector 1st Floor Building 1 Unit D Entry Area Tested 1:18:32 PM 10/13/2026 Heat Detector 1st Floor Building 1 Unit D Entry Areaby Reception Tested 1:12:44 PM 10/13/2026 Heat Detector 1st Floor Building 1 Unit D Repair Shop Tested 1:14:33 PM 10/13/2026 Page of 10 14 Service Summary Cape Cod Alarm Download Date: 10/15/2026 SERVICE SUMMARY Generated by: BuildingReports.com The Service Summary section provides an overview of the services performed in this report. Building: Sunflower Marketplace - Building 1 Device Type Service Quantity PASSED Battery, Sealed Lead Acid Tested 3 Communicator, Mesh Radio Network Tested 1 Control Panel, Conventional Tested 1 Heat Detector, Hardwire - Combination Tested 1 Horn/Strobe Tested 4 Monitoring, Alarm Signal Tested 1 Monitoring, Trouble Signal Tested 1 Pull Station, Dual Action Tested 1 Smoke Detector Tested 3 Strobe Tested 1 Total 17 FAILED/OTHER Heat Detector, Hardwire - Combination Tested 9 Total 9 Grand Total 26 Page of 11 14 Sound and Visual Testing Cape Cod Alarm Download Date: 10/15/2026 SOUND AND VISUAL TESTING Generated by: BuildingReports.com The Sound and Visual Testing section lists various points throughout your building where audible and visual alarm notification devices were tested. Any bar-coded audible and visual devices will appear in the Inspection and Testing section of this report. Items in this section are grouped by Passed or Failed/Other. Where specific decibel readings were recorded, they will appear under the ambient and alarm columns. The Voice column indicates whether the Sound Test Point passed the Voice Intelligibility requirements. The STI or Sound Transmission Index is shown if recorded. Building: Sunflower Marketplace - Building 1 Audible/Visual Appliances Location Comment Ambient Alarm Synched ScanID PASSED Horn/Strobe 1st Floor Building 1 Unit C Entry Foyer Passed ☐B9520960 1st Floor Building 1 Unit B Entry Foyer Passed ☐B9520961 1st Floor Building 1 Unit D Entry Foyer Passed ☐B9520964 1st Floor Building 1 Unit E Entry Foyer Passed ☐B9520973 Strobe Outside Building 1 Unit D Passed ☐B9520956 Page of 12 14 Battery & Power Supply Testing Cape Cod Alarm Download Date: 10/15/2026 Control Panel: 1 - Notifier SFP-40BBuilding: Sunflower Marketplace - Building 1 BATTERY & POWER SUPPLY TESTING Generated by: BuildingReports.com The Battery & Power Supply Testing section details the readings and measurements of batteries and power supplies used to provide power to the fire alarm and life safety systems. Items are grouped by Passed or Failed/Other. Battery Type Location Rated Ah Rated Volts Pre Test Post Test Min Ah Teste d Ah MFG Date PASSED Sealed Lead Acid In AES Trasnmitter 5 12 100%100%11/13 /2024 Sealed Lead Acid In Fire Alaem Control Panel 7 12 100%100%10/13 /2026 Sealed Lead Acid In Fire Alarm Control Panel 7 12 100%100%10/13/2026 Page of 13 14 Inventory & Warranty Report Cape Cod Alarm Download Date: 10/15/2026 Control Panel: 1 - Notifier SFP-40BBuilding: Sunflower Marketplace - Building 1 INVENTORY & WARRANTY REPORT Generated by: BuildingReports.com The Inventory & Warranty Report lists each of the devices and items that are included in your Inspection Report. A complete inventory count by device type and category is provided. Items installed within the last 90 days, within the last year, and devices installed for two years or more are grouped together for easy reference. Building: Sunflower Marketplace - Building 1 Device or Type Category % of Inventory Quantity Battery Control 11.54%3 Communicator Control 3.85%1 Control Panel Control 3.85%1 Heat Detector Initiating 38.46%10 Horn/Strobe Indicating 15.38%4 Monitoring Monitor 7.69%2 Pull Station Initiating 3.85%1 Smoke Detector Initiating 11.54%3 Strobe Indicating 3.85%1 Type Qty Model #Description Install Date NEW (UNDER 90 DAYS) AES Communicator 1 7788F Mesh Radio Network 10/13/2026 Power Patrol Battery 2 FAS1075 Sealed Lead Acid 10/13/2026 Silent Knight Pull Station 1 PS-DA Dual Action 10/13/2026 System Sensor Heat Detector 1 5601P Hardwire - Combination 10/13/2026 Page of 14 14 Inventory & Warranty Report Cape Cod Alarm Download Date: 10/15/2026 Type Qty Model #Description Install Date NEW (UNDER 90 DAYS)(continued) System Sensor (continued) Smoke Detector 3 2100 10/13/2026 Wheelock Horn/Strobe 4 MT-24-LSM 10/13/2026 Strobe 1 10/13/2026 (manufacturer not specified) Monitoring 1 Alarm Signal 10/13/2026 Monitoring 1 Trouble Signal 10/13/2026 IN SERVICE - 1 YEAR TO 2 YEARS Notifier Control Panel 1 SFP-40B Conventional 11/13/2024 Power Patrol Battery 1 FAS1055 Sealed Lead Acid 11/13/2024 IN SERVICE - 25 YEARS OR OLDER Edwards Heat Detector 9 281BPL Hardwire - Combination 10/13/1998