HomeMy WebLinkAbout2026 FIRE ALARM INSPECTION BUILDING REPORT (3)2026 Sunflower Marketplace - Building 4 923 Route 6A Yarmouthport, MA 02675 (508)362-5439 Building Contact:Nancy Basler Title:Contact Company:Cape Cod Alarm Contact:Chad Benaka Title:Service Tech Fire Alarm Systems INSPECTIONCERTIFICATE Oct 13, 2026Inspection Date: Tested to NFPA 72 Standards This Inspection was performed in accordance with applicable NFPA Standards. The subsequent pages of this report provide performance measurements, listed ranges of acceptable results, and complete documentation of the inspection. Whenever discrepancies exist between acceptable performance standards and actual test results, notes and/or recommended solutions have been proposed or provided for immediate review and approval. Page of 2 14 Executive Summary Cape Cod Alarm Download Date: 10/15/2026 EXECUTIVE SUMMARY Generated by: BuildingReports.com Building Information Sunflower Marketplace - Building 4 923 Route 6A Yarmouthport, MA 02675 United States of America Contact: Nancy Basler Phone: (508)367-6991 Fax: Mobile: Email: Inspection Performed By Cape Cod Alarm204 Old Townhouse RoadWest Yarmouth, MA 02673United States of America Inspector: Chad Benaka Phone: (508) 398-6316 Fax: Mobile: Email: service@capecodalarm.com System Control Unit Manufacturer: Silent Knight Inspection Date: 10/13/2026 IDC Style: E Model Number: 5207 Install Date: 10/13/2026 SLC Style: N/A Software Version:Version Date: 12/31/1969 NAC Style: E Location: 1st Floor Building 4 Main Entry Foyer Disconnect Location:Disconnect Type: Current Protection: Breaker Monitoring Company: Cape Cod Alarm Phone: (508)398-6316 Account #: S0210085 Central Station Signal Verification Type: Mesh Radio Network Mfg: AES Model #: 7050-E Test Time/Date: 10/13/26 11:46:01 AM Restore Time: 12:00 PM Note: Type of Signal Signal Confirmed Time Notes Trouble Signal 11:47 AM Alarm Signal 11:48 AM Page of 3 14 Executive Summary Cape Cod Alarm Download Date: 10/15/2026 Building: Sunflower Marketplace - Building 4 Contact: Nancy Basler Company: Cape Cod Alarm Inspector: Chad Benaka Inspection Summary Category Total Items Serviced Passed Failed/Other Qty %Qty %Qty %Qty % Control 5 16.67%5 100.00%5 100.00%0 0.00% Indicating 4 13.33%4 100.00%4 100.00%0 0.00% Initiating 19 63.33%19 100.00%13 68.42%6 31.58% Monitor 2 6.67%2 100.00%2 100.00%0 0.00% Totals 30 100%30 100.00%24 80.00%6 20.00% Certification Page of 4 14 Discrepancy Report Cape Cod Alarm Download Date: 10/15/2026 Control Panel: 1 - Silent Knight 5207Building: Sunflower Marketplace - Building 4 DISCREPANCY REPORT Deficiency, Impairment, and Observation Generated by: BuildingReports.com The Discrepancy Report consolidates each discrepancy listed within the various Testing sections of your Inspection. Discrepancies are listed by Category, and grouped by device type. The description of the problem is provided and where appropriate, code references are listed for your convenience. Any item that was inspected that is subject to a recall or part of a manufacturer's replacement/upgrade program is included. This section is now enhanced by BuildingReports AI, which helps refine applicable manufacturer recalls and replacement notices, enabling service providers and facilities to address potential issues more quickly. Building: Sunflower Marketplace - Building 4 Items listed for Recall or Replacement/Upgrade Device Type Manufacturer Model Number Date Qty No recalled items found during this inspection. Discrepancies ScanID Location Problem Address Reference INITIATING Heat Detector B9520931 1st Floor Building 4 Unit N Hallway Date Expired 1 NFPA72 Table 14.4.3.2 (17)(4)(c) B9520798 1st Floor Building 4 Unit O Hallway Date Expired 1 NFPA72 Table 14.4.3.2 (17)(4)(c) B9520930 1st Floor Building 4 Unit O Hallway Rear Date Expired 1 NFPA72 Table 14.4.3.2 (17)(4)(c) B9520829 1st Floor Building 4 Unit S Right Side Back Room Date Expired 1 NFPA72 Table 14.4.3.2 (17)(4)(c) B9520830 2nd Floor Building 4 Unit P Date Expired 1 NFPA72 Table 14.4.3.2 (17)(4)(c) Page of 5 14 Discrepancy Report Cape Cod Alarm Download Date: 10/15/2026 ScanID Location Problem Address Reference INITIATING (continued) Heat Detector (continued) B9520888 2nd Floor Building 4 Unit Q Date Expired 1 NFPA72 Table 14.4.3.2 (17)(4)(c) Code References NFPA72 Table 14.4.3.2 (17) (4)(c) After 15 years from initial installation, replace all devices or have 2 detectors per 100 laboratory tested. Page of 6 14 Proposed Solutions Report Cape Cod Alarm Download Date: 10/15/2026 Control Panel: 1 - Silent Knight 5207Building: Sunflower Marketplace - Building 4 PROPOSED SOLUTIONS REPORT Generated by: BuildingReports.com The Proposed Solution Report provides a solution for each discrepancy listed on the Discrepancy Report. Provide a check mark where indicated to approve repairs listed within the report. Items listed as T/M are available for repair on a Time and Materials basis. ScanID Location Solution Model #Cost Fixed Date INITIATING Heat Detector B9520931 1st Floor Building 4 Unit N Hallway Replace 281A T/M B9520798 1st Floor Building 4 Unit O Hallway Replace 281A T/M B9520930 1st Floor Building 4 Unit O Hallway Rear Replace 281A T/M B9520829 1st Floor Building 4 Unit S Right Side Back Room Replace 281A T/M B9520830 2nd Floor Building 4 Unit P Replace 281A T/M B9520888 2nd Floor Building 4 Unit Q Replace 281A T/M Customer WO/PO #:(none)Internal WO/PO #:(none)Total: T/M Page of 7 14 Notes & Recommendations Cape Cod Alarm Download Date: 10/15/2026 NOTES & RECOMMENDATIONS Generated by: BuildingReports.com The Notes & Recommendations Report details additional inspection notes made by the Inspectors during the course of the building inspection. Notes are grouped by Category. General Note Unit S ( Salon) has no audible devices inside this shop. No access to Unit M AES radio needs to be replaced to a red fire radio and we need to get rid of the power situation inside the fire panel and put in a transformer for the radio power. Page of 8 14 Inspection & Testing Cape Cod Alarm Download Date: 10/15/2026 Control Panel: 1 - Silent Knight 5207Building: Sunflower Marketplace - Building 4 INSPECTION & TESTING Generated by: BuildingReports.com The Inspection & Testing section lists all of the items inspected in your building. Items are grouped by Passed or Failed/Other . Items are listed by Category. Each item includes the services performed, and the time & date at which testing occurred. Device Type Location Service Time Date PASSED Control Battery In Fire Alarm Control Panel Tested 11:49:32 AM 10/13/2026 Battery In Fire Alarm Control Panel Tested 11:49:45 AM 10/13/2026 Battery in AES Transmitter Tested 11:48:08 AM 10/13/2026 Communicator 1st Floor Building 4 Main Entry Foyer Tested 11:46:01 AM 10/13/2026 Control Panel 1st Floor Building 4 Main Entry Foyer Tested 11:45:22 AM 10/13/2026 Indicating Horn 1st Floor Building 4 Unit L Front Entry Tested 11:53:41 AM 10/13/2026 Horn 2nd Floor Building 4 Main Entry Foyer Tested 11:40:36 AM 10/13/2026 Horn 2nd Floor Building 4 at top of stairs Tested 11:30:10 AM 10/13/2026 Strobe Outside Main Entry Foyer Tested 11:50:25 AM 10/13/2026 Initiating Heat Detector 1st Floor Building 4 Unit L Hallway Rear Tested 11:55:40 AM 10/13/2026 Heat Detector 1st Floor Building 4 Unit S Right Side Tested 11:18:57 AM 10/13/2026 Pull Station 1st Floor Building 4 Unit L Front Entry Tested 11:52:36 AM 10/13/2026 Pull Station 1st Floor Building 4 Unit S Front Entry Tested 11:17:52 AM 10/13/2026 Pull Station 2nd Floor Building 4 at top of stairs Tested 11:28:20 AM 10/13/2026 Smoke Detector 1st Floor Building 4 Unit L Hallway Front Tested 11:53:15 AM 10/13/2026 Smoke Detector 1st Floor Building 4 Unit L Hallway Rear Tested 11:55:09 AM 10/13/2026 Smoke Detector 1st Floor Building 4 Unit L Room 101 Tested 11:54:47 AM 10/13/2026 Page of 9 14 Inspection & Testing Cape Cod Alarm Download Date: 10/15/2026 Device Type Location Service Time Date PASSED (continued) Initiating (continued) Smoke Detector 1st Floor Building 4 Unit L Room 102 Tested 11:56:28 AM 10/13/2026 Smoke Detector 1st Floor Building 4 Unit L Staff Room Tested 11:54:14 AM 10/13/2026 Smoke Detector 1st Floor Building 4 Unit S Right Side Tested 11:19:38 AM 10/13/2026 Smoke Detector 2nd Floor Building 4 Main Entry Foyer Tested 11:40:14 AM 10/13/2026 Smoke Detector 2nd Floor Building 4 at top of stairs Tested 11:31:23 AM 10/13/2026 Monitor Monitoring Alarm Signal Tested 11:47:30 AM 10/13/2026 Monitoring Trouble Signal Tested 11:47:08 AM 10/13/2026 FAILED/OTHER Initiating Heat Detector 1st Floor Building 4 Unit N Hallway Tested 11:33:13 AM 10/13/2026 Heat Detector 1st Floor Building 4 Unit O Hallway Tested 11:38:04 AM 10/13/2026 Heat Detector 1st Floor Building 4 Unit O Hallway Rear Tested 11:38:38 AM 10/13/2026 Heat Detector 1st Floor Building 4 Unit S Right Side Back Room Tested 11:20:51 AM 10/13/2026 Heat Detector 2nd Floor Building 4 Unit P Tested 11:24:27 AM 10/13/2026 Heat Detector 2nd Floor Building 4 Unit Q Tested 11:25:26 AM 10/13/2026 Page of 10 14 Service Summary Cape Cod Alarm Download Date: 10/15/2026 SERVICE SUMMARY Generated by: BuildingReports.com The Service Summary section provides an overview of the services performed in this report. Building: Sunflower Marketplace - Building 4 Device Type Service Quantity PASSED Battery, Sealed Lead Acid Tested 3 Communicator, Mesh Radio Network Tested 1 Control Panel, Conventional Tested 1 Heat Detector, Hardwire - Combination Tested 2 Horn Tested 3 Monitoring, Trouble Signal Tested 1 Monitoring, Alarm Signal Tested 1 Pull Station, Dual Action Tested 2 Pull Station, Single Action Tested 1 Smoke Detector Tested 8 Strobe Tested 1 Total 24 FAILED/OTHER Heat Detector, Hardwire - Combination Tested 6 Total 6 Grand Total 30 Page of 11 14 Sound and Visual Testing Cape Cod Alarm Download Date: 10/15/2026 SOUND AND VISUAL TESTING Generated by: BuildingReports.com The Sound and Visual Testing section lists various points throughout your building where audible and visual alarm notification devices were tested. Any bar-coded audible and visual devices will appear in the Inspection and Testing section of this report. Items in this section are grouped by Passed or Failed/Other. Where specific decibel readings were recorded, they will appear under the ambient and alarm columns. The Voice column indicates whether the Sound Test Point passed the Voice Intelligibility requirements. The STI or Sound Transmission Index is shown if recorded. Building: Sunflower Marketplace - Building 4 Audible/Visual Appliances Location Comment Ambient Alarm Synched ScanID PASSED Strobe Outside Main Entry Foyer Passed ☐B9520944 Page of 12 14 Battery & Power Supply Testing Cape Cod Alarm Download Date: 10/15/2026 Control Panel: 1 - Silent Knight 5207Building: Sunflower Marketplace - Building 4 BATTERY & POWER SUPPLY TESTING Generated by: BuildingReports.com The Battery & Power Supply Testing section details the readings and measurements of batteries and power supplies used to provide power to the fire alarm and life safety systems. Items are grouped by Passed or Failed/Other. Battery Type Location Rated Ah Rated Volts Pre Test Post Test Min Ah Teste d Ah MFG Date PASSED Sealed Lead Acid In Fire Alarm Control Panel 7 12 100%100%10/13 /2026 Sealed Lead Acid In Fire Alarm Control Panel 7 12 100%100%10/13 /2026 Sealed Lead Acid in AES Transmitter 7 12 100%100%10/13/2026 Page of 13 14 Inventory & Warranty Report Cape Cod Alarm Download Date: 10/15/2026 Control Panel: 1 - Silent Knight 5207Building: Sunflower Marketplace - Building 4 INVENTORY & WARRANTY REPORT Generated by: BuildingReports.com The Inventory & Warranty Report lists each of the devices and items that are included in your Inspection Report. A complete inventory count by device type and category is provided. Items installed within the last 90 days, within the last year, and devices installed for two years or more are grouped together for easy reference. Building: Sunflower Marketplace - Building 4 Device or Type Category % of Inventory Quantity Battery Control 10.00%3 Communicator Control 3.33%1 Control Panel Control 3.33%1 Heat Detector Initiating 26.67%8 Horn Indicating 10.00%3 Monitoring Monitor 6.67%2 Pull Station Initiating 10.00%3 Smoke Detector Initiating 26.67%8 Strobe Indicating 3.33%1 Type Qty Model #Description Install Date NEW (UNDER 90 DAYS) AES Communicator 1 7050-E Mesh Radio Network 10/13/2026 Fire-Lite Pull Station 1 BG-12 Dual Action 10/13/2026 Notifier Pull Station 1 NBG-12L Dual Action 10/13/2026 Power Patrol Battery 3 FAS1075 Sealed Lead Acid 10/13/2026 Page of 14 14 Inventory & Warranty Report Cape Cod Alarm Download Date: 10/15/2026 Type Qty Model #Description Install Date NEW (UNDER 90 DAYS)(continued) Silent Knight Control Panel 1 5207 Conventional 10/13/2026 System Sensor Heat Detector 2 5601P Hardwire - Combination 10/13/2026 Smoke Detector 5 2100 10/13/2026 Smoke Detector 1 2WBT 10/13/2026 Wheelock Strobe 1 10/13/2026 (manufacturer not specified) Monitoring 1 Alarm Signal 10/13/2026 Monitoring 1 Trouble Signal 10/13/2026 IN SERVICE - 25 YEARS OR OLDER Chemtron Heat Detector 6 281A Hardwire - Combination 10/13/1986 Edwards Horn 3 31T-115-R 10/13/1986 Pull Station 1 270 Single Action 10/13/1986 System Sensor Smoke Detector 2 SD-800 10/13/1986