HomeMy WebLinkAbout5 Franklin St Title 5 Site Plan Revised 12.04.18ACCESS COVERS TO WITHIN 6" OF FIN. GRADE TOP FOUND. EL. 21.6' _ MINIMUM .75' OF COVER OVER PRFCAST SYSTEM PROFILE (NOT TO SCALE) 2" PEASTONE OR GEOTEXTILE FILTER FABRIC OVER STONE PRECAST H-10 RISERS (TYP.) 2 0 19'9INSTALL TEE 4" OSCH40 PVC o PIPES LEVEL 1ST 2' 10" EXISTING 1411 TEE SEPTIC TANK** TEE *18.6't GAS BAFFLE t_ 17.88' 17.71 ' �!• WATERTEST D'BOX FOR LEVELNESS 6" CRUSHED STONE OR MECHANICAL COMPACTION. (15.221 [21) ( 9 % SLOPE) FOUNDATION -EXISTING SEPTIC TANK 8' D' BOX *THE INSTALLER SHALL VERIFY THE LOCATIONS OF ALL **INSTALLER SHALL CONFIRM MINIMUM SEPTIC TANK SIZE AT UTILITIES AND ALL BUILDING SEWER OUTLETS AND ELEVATIONS 1000 GALLONS AND ITS SUITABILITY FOR RE -USE. REPLACE PRIOR TO INSTALLING ANY PORTION OF SEPTIC SYSTEM WITH 1500 GALLON SEPTIC TANK APPROPRIATE TO SITE CONDITIONS IF NOT SUITABLE LEGEN D 99 - EXISTING CONTOUR X 99• 1 EXIST. SPOT ELEV. -[991-- PROPOSED CONTOUR 19$•41 PROPOSED SPOT EL. TH1 TEST HOLE SLOPE OF GROUND UTILITY POLE FIRE HYDRANT NOTE NOT ALL SYMBOLS MAY APPEAR IN DRAWING TEST HOLE LOGS ENGINEER: DANIEL E. GONSALVES, SE #13587 WITNESS: PHIL RENAUD DATE: 1 1 /7/ 18 PERC. RATE _ < 2 MIN/INCH CLASS I SOILS Q ELEV. 1. 011 20.5' � V 0 ` \ GRAVEL DRIVE / OH w�RES FI LL 10" \ c A LS 'EXIS\TING15" 1OYR 4/2 DWE B LS 30" 1OYR 5/6 18' C PERC MS 2.5Y 7/4 120" I 110.5 NO GROUNDWATER ENCOUNTERED LICE # 13-397 (1 % SLOPE) 6' - ALL SYSTEM COMPONENTS SHALL BE MARKED WITH MAGNETIC TAPE OR COMPARABLE MEANS FOR FUTURE LOCATION. PROVIDE INSPECTION PORTS TO WITHIN 3" OF FINISH GRADE OVER SYSTEM • 17.0' QUICK4 PLUS STANDARD LOW PROFILE UNITS OVERALL DIMENSIONS TO CUTSIDE OF UNITS: 17.0'xll.33' (NO STON= PROPOSED) LEACHING FACILITY NOTES 1. DATUM IS NAVD 88 2. MUNICIPAL WATER IS EXISTING Whites Path 3. MINIMUM PIPE PITCH TO BE 1 /8" PER FOOT. 4. DESIGN LOADING FOR ALL PROPOSED PRECAST eac Locus UNITS TO BE AASHO H-10 5. PIPE JOINTS TO BE MADE WATERTIGHT. r wnin9 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH 310 CMR 15.000 (TITLE 5.) o z 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO BE USED FOR LOT LINE STAKING OR ANY OTHER PURPOSE. sro�. o mall o at n 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC. `1'n�j9� a 00 00� 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT INSPECTION BY BOARD OF �. oor eg nod HEALTH AND PERMISSION OBTAINED FROM BOARD Hazelm OF HEALTH. 10. CONTRACTOR SHALL BE RESPONSIBLE FOR CALLING (1-888-344-7233) AND VERIFYING IGSAFE THE LOCATION OF ALL UNDERGROUND & LOCUS MAP OVERHEAD UTILITIES PRIOR TO COMMENCEMENT OF WORK. SCALE 1 "=2000'f 11. ANY UNSUITABLE MATERIAL ENCOUNTERED SHALL ASSESSORS MAP 99 PARCEL 86 BE REMOVED BENEATH AND 5' AROUND THE PROPOSED LEACHING FACILITY. LOCUS IS WITHIN FEMA FLOOD ZONE X 12. EXISTING LEACHING FACILITY SHALL BE PUMPED (AREA OF MINIMAL FLOOD HAZARD) AS AND REMOVED. SHOWN ON COMMUNITY PANEL #25001 CO587J DATED 7/16/2014 A TWO BEDROOM DEED RESTRICTION IS REQUIRED VARIANCES REQUESTED: SYSTEM DESIGN. UNDER MAX. FEASIBLE COMPLIANCE 15.405: (1a): REDUCTION IN SETBACK, SAS TO LOT LINE (10' TO 5') GARBAGE DISPOSER IS NOT ALLOWED (1b): REDUCTION IN SETBACK, SAS TO FOUNDATION (20' TO 12.8' & 13.4') 6.5' BOTTOM TH 1 EL. 10.5, 'll c, O A 0 'v < 8S cF 14 \ H' ` O TH1 s�A , BENCHMARK: CONC. STEP AT ELEV. 21.7' EXISTING GAS DWELLING MTR. TOF=21.6' 1� sy 8S 20 Op, LOT 284 4,221 t SF100, O SAND_ J EXISTING, DWELLING • • 10 20 30 40 50 FEE I EXISTING 2 BEDROOM DWELLING DESIGN FLOW: 2 BEDROOMS @ 110 GPD = 220 GPD USE A 220 GPD DESIGN FLOW SEPTIC TANK: 220 GPD (2) = 440 _**RE -USE EXISTING 1000 GAL. SEPTIC -TANK - LEACHING: 4.73 SF/LF x 4' LENGTH = 18.92 SF PER QUICK4 PLUS STANDARD LP UNIT LLIVINGFOOM BEDROOM 220 GPD/0.74 GPD/SF = 297.3 SF LEACHING REQ'D 297.3 SF/18.92 SF/UNIT = 15.7 UNITS KITCHEN 0 BEDROOM THEREFORE, USE GRAVELLESS SYSTEM OF (16) a QUICK4 PLUS STANDARD LP UNITS IN FIELD CONFIGURATION AS SHOWN 16 UNITS x 18.92 SF/UNIT = 302.72 SF > 297.3 SF 297.3 SF (0.74) = 220 GPD (OK) FLOOR PLAN NOT TO SCALE APPROVED DATE BOARD OF HEALTH Permit ,dlid for REPAIR I.o Fa'Il( s}irces. TITLE 5 SITE PLAN ONLY,, due to State and Local septic variances. Board of Ife lth review and approval is required for any future ' ad41 ions/re00% a+ions/alterations to OF sewage facilities and/or shructua cs/dwcdling. Y;irt»outh Ilealtlt Depat'tntent 5 FRANKLIN STREET IMIIR IIJ,)` A f� SOUTH YARMOUTH, MA are e.. Date k- `A-�� DATE DANIEL A. OJALA, P.E., P.L.S. PREPARED FOR MCKENZIE DATE: NOVEMBER 27, 2018 REV.: DECEMBER 4, 2018 (WATER MAINS) off 508-362-4541 I fax 508-362-9880 downcope.com VOWN CI.Pe eel i4eer lit', il?C. civil engineers land surveyors 939 Main Street ( R to 6A) YARMOUTHPORT MA 02675 18-397 CCSEPTIC-MCKENZIE.DWG