HomeMy WebLinkAboutFire Alarm System i , r a T 1 I 111 } 9 (1111"—Li5t1 --- ,. 4%4,, f� �.� BUILDING �• REPORTS rti ! Fire Alarm Systems - „ • • I �'� ; ' 4 INSPECTION ,� FM P II 4. r, 4 /. � , ' CERTIFICATE Hearth N' Kettle 1196 Route 28 South Yarmouth, MA 02664 (508)394-2252 Building Contact: Fabio Lima Title: Contact Company: Cape Cod Alarm = Contact: Marty Crowell Title: Installer i OCT 2 9 2026 A i L BuILDING Dr_i: ‘r.1I :c ' T �y I Inspection Date: Oct 15, 2026 Tested to NFPA 72 Standards This Inspection was performed in accordance with applicable NFPA Standards.The subsequent pages of this report provide performance measurements,listed ranges of acceptable results,and complete documentation of the inspection.Whenever discrepancies exist between acceptable performance standards and actual test results,notes and/or recommended solutions have been proposed or provided for immediate review and approval. r I EXECUTIVE 5 MMARY Generated by: BuildingeDorts.com Building Information Hearth N'Kettle Contact: Fabio Lima 1196 Route 28 Phone:(508)394-2252 South Yarmouth, MA 02664 United States of America Fax: Mobile: Email: Inspection Performed By Cape Cod Alarm Inspector: Marty Crowell 204 Old Townhouse Road Phone:(508) 398-6316 West Yarmouth, MA 02673 United States of America Fax: Mobile: Email:service@capecodalarm.com System Control Unit Manufacturer: Fire-Lite Inspection Date: 10/15/2026 IDC Style: E Model Number:MS-10UD Install Date: 10/15/2026 SLC Style: N/A Software Version: Version Date: 10/15/2026 NAC Style: E Location: Kitchen Area Rear Door Disconnect Location: Disconnect Type: Current Protection: Breaker Monitoring Company:Cape Cod Alarm Phone: Account#:S29192 Central Station Signal Verification Type: Mesh Radio Network Mfg:AES Model#: 7788F Test Time/Date: 10/15/26 3:28:35 PM Restore Time:4:13 PM Note: Type of Signal Signal Confirmed Time Notes Alarm Signal 3:36 PM Trouble Signal 3:37 PM Cape Cod Alarm Page 2 of 12 Download Date: 10/16/2026 Executive Summary DIS " AN EPO Deficiency, Impairment, and Observation Generated by: BuilcingReports.com The Discrepancy Report consolidates each discrepancy listed within the various Testing sections of your Inspection. Discrepancies are listed by Category,and grouped by device type.The description of the problem is provided and where appropriate,code references are listed for your convenience.Any item that was inspected that is subject to a recall or part of a manufacturer's replacement/upgrade program is included. This section is now enhanced by BuildingReports Al,which helps refine applicable manufacturer recalls and replacement notices,enabling service providers and facilities to address potential issues more quickly. Building: Hearth N' Kettle Items listed for Recall or Replacement/Upgrade Device Type Manufacturer Model Number Date Qty No recalled items found during this inspection. Building: Hearth N' Kettle Control Panel: 1 - Fire-Lite MS-10UD Discrepancies ScanID Location Problem Address Reference INITIATING Heat Detector A9019345 Basement Prep Room Date Expired 1 NFPA72 Table 14.4.3.2(17)(4)(c) A9019344 Basement Stairs Date Expired 1 NFPA72 Table 14.4.3.2(17)(4)(c) A9019330 Attic above Kitchen(East) Date Expired 1 NFPA72 Table 14.4.3.2(17)(4)(c) A9019331 Attic above Kitchen(South) Date Expired 1 NFPA72 Table 14.4.3.2(17)(4)(c) Code References NFPA72 Table 14.4.3.2(17) After 15 years from initial installation, replace all devices or have 2 detectors per 100 (4)(c) laboratory tested. Cape Cod Alarm Page 4 of 12 Download Date: 10/16/2026 Discrepancy Report Inspection Summary Total Items Serviced Passed Failed/Other Category Qty % Qty % Qty % Qty % Alarm 1 3.45% 1 100.00% 1 100.00% 0 0.00% Control 6 20.69% 6 100.00% 6 100.00% 0 0.00% Indicating 8 27.59% 8 100.00% 8 100.00% 0 0.00% Initiating 12 41.38% 12 100.00% 8 66.67% 4 33.33% Monitor 2 6.90% 2 100.00% 2 100.00% 0 0.00% Totals 29 100% 29 100.00% 25 86.21% 4 13.79% Certification Company:Cape Cod Alarm Building: Hearth N' Kettle Inspector: Marty Crowell Contact: Fabio Lima Cape Cod Alarm Page 3 of 12 Download Date: 10/16/2026 Executive Summary INSPECTION & TESTING Generated by: BuildingReports.com The Inspection&Testing section lists all of the items inspected in your building. Items are grouped by Passed or Failed/Other. Items are listed by Category. Each item includes the services performed,and the time&date at which testing occurred. Bulling: Hearth N` Kettle Control Panel: 1 - Fire-Lite MS-1OUD Device Type Location Service Time Date PASSED Alarm Kitchen Hood Kitchen Area Tested 3:25:35 PM 10/15/2026 Control Annunciator Lobby South Entry Tested 3:42:07 PM 10/15/2026 Battery Kitchen Area in AES Transmitter Tested 3:28:02 PM 10/15/2026 Battery Kitchen Area in Fire Alarm Control Panel Tested 3:26:20 PM 10/15/2026 Battery Kitchen Area in Fire Alarm Control Panel Tested 3:27:32 PM 10/15/2026 Communicator Kitchen Area Tested 3:28:35 PM 10/15/2026 Control Panel Kitchen Area Rear Door Tested 3:24:31 PM 10/15/2026 Indicating Horn/Strobe East Dining Area Entry Tested 3:46:46 PM 10/15/2026 Horn/Strobe Kitchen Rear Tested 3:37:21 PM 10/15/2026 Horn/Strobe South Dining Area Tested 3:39:47 PM 10/15/2026 Horn/Strobe South Dining Area Entry Tested 3:45:05 PM 10/15/2026 Horn/Strobe East Dining Area Exit Farrington Room Tested 3:49:15 PM 10/15/2026 Horn/Strobe Basement by door Tested 3:55:13 PM 10/15/2026 Strobe Ladies' Room Tested 3:41:04 PM 10/15/2026 Strobe Men's Room Tested 3:40:31 PM 10/15/2026 Initiating Pull Station Kitchen Rear Tested 3:35:35 PM 10/15/2026 Cape Cod Alarm Page 6 of 12 Download Date: 10/16/2026 Inspection&Testing PROPOSED SOLUTIONS REPORT Generated by: BuildingReports.com The Proposed Solution Report provides a solution for each discrepancy listed on the Discrepancy Report. Provide a check mark where indicated to approve repairs listed within the report. Items listed as T/M are available for repair on a Time and Materials basis. Building: Hearth N' Kettle Control Panel: 1 - Fire-Lite MS-10UD ScanID Location Solution Model# Cost Fixed Date INITIATING Heat Detector A9019345 Basement Prep Room Replace Twist out T/M A9019344 Basement Stairs Replace Twist out T/M A9019330 Attic above Kitchen(East) Replace Twist out T/M A9019331 Attic above Kitchen(South) Replace Twist out T/M Customer WO/PO#: Internal WO/PO#: Total:T/M (none) (none) Cape Cod Alarm Page 5 of 12 Download Date: 10/16/2026 Proposed Solutions Report SERVICE SUMMARY Generated by: BuildingRenorts.com The Service Summary section provides an overview of the services performed in this report. Building: Hearth N` Kettle Device Type Service Quantity PASSED Annunciator Tested 1 Battery,Sealed Lead Acid Tested 3 Communicator, Mesh Radio Network Tested 1 Control Panel,Conventional Tested 1 Horn/Strobe Tested 6 Kitchen Hood, Dry Tested 1 Monitoring,Alarm Signal Tested 1 Monitoring,Trouble Signal Tested 1 Pull Station, Dual Action Tested 4 Smoke Detector Tested 4 Strobe Tested 2 Total 25 FAILED/OTHER Heat Detector, Hardwire- Fixed Tested 4 Temperature Total 4 Grand Total 29 Cape Cod Alarm Page 8 of 12 Download Date: 10/16/2026 Service Summary Device Type Location Service Time Date PASSED(continued) Initiating(continued) Pull Station South Entry Tested 3:45:51 PM 10/15/2026 Pull Station South Exit(Farrington Room) Tested 3:50:21 PM 10/15/2026 Pull Station Basement by door Tested 3:56:18 PM 10/15/2026 Smoke Detector Dining Area East Tested 3:47:32 PM 10/15/2026 Smoke Detector above Bar Tested 3:43:22 PM 10/15/2026 Smoke Detector Dining Area East Farrington Room Tested 3:48:13 PM 10/15/2026 Smoke Detector Basement Utility Arrea Tested 3:57:06 PM 10/15/2026 Monitor Monitoring Alarm Signal Tested 3:29:05 PM 10/15/2026 Monitoring Trouble Signal Tested 3:29:15 PM 10/15/2026 FAILED/OTHER Initiating Heat Detector Basement Prep Room Tested 3:55:00 PM 10/15/2026 Heat Detector Basement Stairs Tested 3:53:58 PM 10/15/2026 Heat Detector Attic above Kitchen(East) Tested 3:34:28 PM 10/15/2026 Heat Detector Attic above Kitchen(South) Tested 3:34:14 PM 10/15/2026 Cape Cod Alarm Page 7 of 12 Download Date: 10/16/2026 Inspection&Testing SOUND AN VISUAL TESTING Generatec by: Builcingeports.com The Sound and Visual Testing section lists various points throughout your building where audible and visual alarm notification devices were tested.Any bar-coded audible and visual devices will appear in the Inspection and Testing section of this report. Items in this section are grouped by Passed or Failed/Other.Where specific decibel readings were recorded,they will appear under the ambient and alarm columns.The Voice column indicates whether the Sound Test Point passed the Voice Intelligibility requirements.The STI or Sound Transmission Index is shown if recorded. Building: Hearth N' Kettle Audible/Visual Appliances Location Comment Ambient Alarm Synched Scan ID PASSED Horn/Strobe Kitchen Rear Passed ❑ A9019323 South Dining Area Passed ❑ A9019332 South Dining Area Entry Passed ❑ A9019337 East Dining Area Entry Passed ❑ A9019339 East Dining Area Exit Farrington Passed ❑ A9019343 Room Basement by door Passed ❑ A9019347 Strobe Men's Room Passed ❑ A9019333 Ladies'Room Passed ❑ A9019334 Cape Cod Alarm Page 9 of 12 Download Date: 10/16/2026 Sound and Visual Testing BATTERY & POWER SUPPLY TESTING Generated by: BuildingReports.com The Battery&Power Supply Testing section details the readings and measurements of batteries and power supplies used to provide power to the fire alarm and life safety systems. Items are grouped by Passed or Failed/Other. Building: Hearth N' Kettle Control Panel: 1 - Fire-Lite MS-10UD Battery Rated Rated Pre Post Min Teste MFG Type Location Ah Volts Test Test Ah d Ah Date PASSED Sealed Lead Acid Kitchen Area in AES Transmitter 7AH 12V 100 80 11/15 /2024 Sealed Lead Acid Kitchen Area in Fire Alarm Control 7AH 12V 100 80 11/15 Panel /2024 Sealed Lead Acid Kitchen Area in Fire Alarm Control 7AH 12V 100 80 11/15 Panel /2024 Cape Cod Alarm Page 10 of 12 Download Date: 10/16/2026 Battery&Power Supply Testing Type Qty Model t# Description Install Date IN SERVICE - 1 YEAR TO 2 YEARS (continued) AES(continued) Communicator 1 7788F Mesh Radio Network 11/15/2024 Monitoring 1 7788F Alarm Signal 11/15/2024 Monitoring 1 7788F Trouble Signal 11/15/2024 Power Patrol Battery 3 FAS-1075 Sealed Lead Acid 11/15/2024 IN SERVICE- 25 YEARS OR OLDER Ademco Pull Station 1 MS-2 Dual Action 10/15/1998 ESL Pull Station 1 Cat 45 key Dual Action 10/15/1998 FCI-Gamewell Pull Station 1 MS-2 Dual Action 10/15/1998 Silent Knight Pull Station 1 1347 key Dual Action 10/15/1998 System Sensor Annunciator 1 Ann 80 10/15/1998 Horn/Strobe 6 P2R(replacement) 10/15/1998 Smoke Detector 4 2W-TB 10/15/1998 Strobe 1 SRL(replacement) 10/15/1998 Strobe 1 SRL(replacement) 10/15/1998 Twist out style Heat Detector 4 Twist out Hardwire- Fixed Temperature 11/15/1998 Cape Cod Alarm Page 12 of 12 Download Date: 10/16/2026 Inventory&Warranty Report INVENTORY & WARRANTY REPORT Generated by: BuildingReports.com The Inventory&Warranty Report lists each of the devices and items that are included in your Inspection Report.A complete inventory count by device type and category is provided. Items installed within the last 90 days,within the last year,and devices installed for two years or more are grouped together for easy reference. Building: Hearth N' Kettle Device or Type Category %of Inventory Quantity Annunciator Control 3.45% 1 Battery Control 10.34% 3 Communicator Control 3.45% 1 Control Panel Control 3.45% 1 Heat Detector Initiating 13.79% 4 Horn/Strobe Indicating 20.69% 6 Kitchen Hood Alarm 3.45% 1 Monitoring Monitor 6.90% 2 Pull Station Initiating 13.79% 4 Smoke Detector Initiating 13.79% 4 Strobe Indicating 6.90% 2 Building: Hearth N' Kettle Control Panel: 1 - Fire-Lite MS-10UD Type Qty Model# Description Install Date NEW(UNDER 90 DAYS) Ansul Kitchen Hood 1 Ansul Dry 10/15/2026 Fire-Lite Control Panel 1 MS-10UD Conventional 10/15/2026 IN SERVICE - 1 YEAR TO 2 YEARS AES Cape Cod Alarm Page 11 of 12 Download Date: 10/16/2026 Inventory&Warranty Report 10/19/26,3:17 PM Gmail-(no subject) Gmail Fabio Lima <fabinhoperrylima@gmail.com> (no subject) 1 message Fabio Lima <fabinhoperrylima@gmail.com> Mon, Oct 19, 2026 at 3:14 PM To: Fabio Lima <fabinhoperrylima@gmail.com> https://mail.google.com/mail/u/1/?ik=41 c46cfe9f&view=pt&search=all&permthid=thread-a:r-4062633720360119612&simpl=msg-a:r-382020312265872... 1/4 10/19/26,3:17 PM Gmail-(no subject) https://mail.google.com/mail/u/1/?ik=41 c46cfe9f&view=pt&search=all&permthid=thread-a:r-4062633720360119612&simpl=msg-a:r-382020312265872... 2/4