Loading...
HomeMy WebLinkAboutEngineered Plan - 2009103. 0 ACCESS COVERS MUST BE WITHIN INSPECTION 9" MINIMUM. 6" OF FINISH GRADE PORT 3' MAXIMUM COVER FIRST 2' TO BE LEVEL MIN 2" OF PEASTONE OR FILTER FABRIC 3/4" - 1 1/2" DIA. 2 25 97 9 $� IO' �, DOUBLE WASHED STONE GAS s 97.83 °0 97.0 BAFFLE 3 OUTLET 5 HIGH CAPACITY INFILTRATOR g D -BOX CHAMBERS W/3.5't STONE AROUND 1500 GAL 10'r x 38'1 x IO'd SEPTIC TANK 6' CRUSHED STONE OR COMPACTED BASE PROFILE : NOT TO SCALE I LOCUS MAP . "&-UP 8631/ r INC WIND �--- 0 10 20 40 INVERT ELEVATIONS INVERT AT BUILDING: 100.75 INVERT IN SEPTIC TANK: 98.5 INVERT OUT SEPTIC TANK: 98.25 INVERT IN DIST. BOX: 98.07 INVERT OUT DIST. BOX: 97.9 INVERT IN LEACH CHAMBER: 97.83 BOTTOM OF LEACH CHAMBER: 97.0 ADJUSTED GROUND WATER: N/A OBSERVED GROUND WATER: N/A BOTTOM OF TEST HOLE 1 : 91.7 N + 40.4 DESIGN CRITERIA: GENERAL NOTES: DESIGN FLOW: —W WATER L I NE 3 BEDROOMS A T I10 G.P.D. PER 1. THIS PLAN IS FOR THE DESIGN AND CONSTRUCTION BEDROOM EQUALS 330 G.P.D. .� OF THE SEWAGE DISPOSAL SYSTEM ONLY. NO GARBAGE GRINDER 2. VERTICAL DATUM IS ASSUMED, FOR BENCH MARKS UNDERGROUND ELECTRIC LINE C. i SET. SEE S I TE PLAN. SEPTIC TANK REQUIRED: NO WA TER 120' 91.7 + 40.4 330 G.P.D. X 20OX -.660 GAL. 3. ALL CONSTRUCTION METHODS AND MATERIALS AND SEPTIC TANK PROVIDED: 1500 GAL. MIN. WITNESSED BY: AMY VONHONE MAINTENANCE OF THE SEPTIC SYSTEM SHALL PERC RATE: l 2 MIN/INCH CONFORM TO MASS. D.E.P. TITLE 5 AND LOCAL SOIL ABSORPTION SYSTEM REQUIRED: BOARD OF HEALTH REGULATIONS. DESIGN PERC RATE ( 5 MIN/INCH W ry"1 A. t SOIL TEXTURAL CLASS - I 4. ALL SEPTIC SYSTEM COMPONENTS LOCATED UNDER EFFLUENT LOADING RATE - 0.74 GPD/SF AREAS SUBJECT TO VEHICULAR TRAFFIC OR GREATER 330 GPD / 0.74 GPD/SF - 446 S.F. REQUIRED THAN 3' IN DEPTH SHALL BE CAPABLE OF WITH- STANDING H-20 WHEEL LOADS. PROVIDED: 5 HIGH CAPACITY INFILTRATOR CHAMBERS W/3.5'± STONE AROUND. A-460 S.F. 5. ALL SEWER PIPE SHALL BE SCHEDULE 40 PVC OR 460 S.F. x 0.74 - 340 GPD APPROVED EQUAL. 6. SEPTIC TANK AND D -BOX SHALL BE REINFORCED SOIL TEST P1 T DATA 6) PRECAST CONCRETE OR APPROVED POLYETHYLENE. BOTH SHALL .BE WATERTIGHT. D -BOX SHALL BE WATER INDICATES QINDICATES PERCOLATION OBSERVED TESTED FOR LEVEL WHEN THERE IS MORE THAN ONE TES T GROUNDWATER OUTLET. TP #1 7. BEFORE CONSTRUCTION CALL "DIG -SAFE'. HORIZON TEXTURE COLOR 1 -888 -DIG -SAFE AND THE LOCAL WATER DEPT. 0. lO1 7 FOR LOCATION OF UNDERGROUND UTILITIES. A LOAMY l 0 YR SAND 5/2 8. EXISTING CESSPOOLS TO BE PUMPED DRY AND 6* .......................................... 101.2 BACKFILLED. B LOAMY IOYR SAND 4/4 18 ' .......................................... 100.2 C J MEDIUM IOYR SAND 6/6 LEGEND 5�. OF CONCRETE BOUND —W WATER L I NE FRANK401 HYDRANT —G GAS LINE .� OVER HEAD WIRES JJ LIGHT POST —E— UNDERGROUND ELECTRIC LINE C. i UNDERGROUND TELEPHONE LINE 2v I NO WA TER 120' 91.7 + 40.4 DATE: SEPTEMBER 10. 2009 –40-- TEST BY: STEPHEN HAAS 40 WITNESSED BY: AMY VONHONE PERC RATE: l 2 MIN/INCH W ry"1 A. t LEGEND El CB CONCRETE BOUND —W WATER L I NE O HYDRANT —G GAS LINE OHW— OVER HEAD WIRES # LIGHT POST —E— UNDERGROUND ELECTRIC LINE —T— UNDERGROUND TELEPHONE LINE — CTV— UNDERGROUND CABLEVISION LINE + 40.4 SPOT ELEVATION –40-- EXISTING CONTOUR 40 PROPOSED CONTOUR �fViL S Ynnn®uth Health Deparlmenttlo. a Fa , L(0L H %i 1 S EP T / C SYS TE -M -O E S / 01V 8 W/ /VD / /VG BROOK ROAD . "AP 6.7. PARCEL 264 ®�T yAA VvTH, A PREPARED F -OR /Iil,�l R Y EL L EIV B A Z/ /V T 241 PRO V / DE/VCE ROAD. SO . GR,4F TON . IVA 0/-500 SC.AL E : / — 20 OCTOBER 6 . 2009 EAGLE SURVEY I NG I NC 923 Route 6A Ya rrno u t h p o r t MA. 02675 (508),362-6132