Loading...
HomeMy WebLinkAboutEngineered Plan - Rev. 1994A tLl to H *< OLD TOWN HOU. 0 c H x x t3 l F rV E N ROAD 4 LOCUS LOCATION MAP LOT 18 17,958 SF ASSESSORS MAP: 66 PARCEL: Y18 CURRENT ZONING: R-15 BUILDING SETBACKS: F: 30' S: 15' R: 20' FLOOD ZONE: C ELEC. MANHOLE OLK AVENUE 71 SUFF t BENCHMARK AT 71 ELEC. MANHOLE 70.7 - ELEV. = 70.9 71 71.4 ® 00--wL- - _ 0 _ _75- 0,0- _ -72 ELEC PAD - - _ ---73 70.5 172.1I - _ ELEC.BO) 70, / - \ - 73 _ t � 7s � g2 tt► tt 73...... t PROPOSED t 3B 00 t DIE oil c: 69- TF. -74.0 \ B � � �'• PATIO " • • � 68.3 �\ _ , 10' MIN 20' MIN Ji S 68' � � . T ` LP TH-1 ' 67 ` X98 WA 66.2 ` 71 70 � ss \ . � ss 68 67 s6 65.3 KEY: EXISTING CONTOUR: - PROPOSED CONTOUR: ............ • • • " • •' • " " • • "' EXISTING SPOT ELEVATION: 25.5 PROPOSED SPOT ELEVATION: 25 TEST HOLE: �- UTILITY POLE: -0- FENCE LINE: HYDRANT: -6 DM # 91=037-18 72 TEST HOLE LOGS ENGINEER: THOMAS McLELLAN, P.E. WITNESS: DAVE .MASON, R.S. DATE:` 6-29-94 PERCOLATION RATE: < 2 MINIIN TH-1 TH-2 71.5 TOP ELEV 36" SUBSOIL 68.5 MEDIUM - FINE SAND 1 59.5 NO GROUNDWATER ENCOUNTERED tzar' 3 NOTES: 1. VERTICAL DATUM: ASSUMED FROM QUAD ND + - 2. MUNICAPAL WATER IS AVAILABLE. R As 3. SCHEDULE 40 - 4" PVC PIPE TO BE USED T ROUGHOUT SEPTIC SYSTEM. 4. ALL PRECAST UNITS TO CONFORM WITH AAS FITO H-10 LOADING SPECIFICATIONS. 5. PIPE PITCH =.1-14" PER FOOT. ELLING 6. FIRST 2' OF PIPE OUT OF D -BOX TO BE LAI LEVEL. 7. THE SEPTIC SYSTEM HAS NOT BEEN DESIGArED TO ACCOMODATE THE USE OF A GARBAGE DISPOSAL. 8. ALL CONSTRUCTION DETAILS ARE TO BE IN ONFORMANCE WITH THE STATE OF MASS. ENVIRONMENTAL CODE (TI rLE FIVE) AND LOCAL HEALTH REGULATIONS. 9. CONTRACTOR TO VERIFY LOCATIONS OF ALL I TTILITIES PRIOR TO CONSTRUCTION. 10. IN ACCORDANCE WITH THE TOWN OF YARMO TH NITROGEN LOADING REGULATION THE FOLLOWING DEED RESTRICTIONS APPLY: A. THE NUMBER OF BEDROOMS SHALL NO EXCEED 3. B. THE LATIN AREA IS TO BE INSPECTED D CERTIFIED BY THE DESIGN ENGINEER (NOT TO EXCEED 2(,00 SF). SEPTIC SYSTEM DESIGN FLOW ESTIMATE: 3 BEDROOMS AT 110 GAL/DAY/BEDROOM = 330 GAL/DAY SEPTIC TANK: LOT 19 330 GAL/DAY * 1.5 DAYS = 495 GAL USE 1000 GALLON SEPTIC TANK LEACHING AREA: USE ONE LEACH PIT (6' x 49 WITH 2' OF STONE (10' EFFECTIVE DIAMETER x 4' DEEP) SIDE AREA. 10 x 4 x PI = 126 SF (2.5) = 315 GAL/ DAY }BOTTOM AREA: 5' x 5' x PI = 78 SF (1.0) _ 8 GAL/DAY TOTAL, CAPACITY = 353 GALII-DAY - SEPTIC SYSTEM SECTION COVERS WITHIN 12" 74.0 OF FINISH GRADE TOP OF FOUNDATION LOT 25 \70.39 70.64 1000 GAL ELEV. D -BOX ELEV. 70.16 71.0 SEPTIC TANK 70.33 ,ELEV. ELEV. ELEV. TEE SIZES: INLET: 6" UP, 10" DOWN OUT LE : 6" UP, 19" DOWN t� DM DEMAREST-McLELLAN ENGINEERING 24 SCHOOL STREET P.O. BOX 463 WEST DENNIS, MASSACHUSETTS 02670 6z� a PATIO PROPOSE11T)) R As 28' 3 BEDROC M DWELLING 28• PROPOSED D ELLING USE ONE LEACH PIT (6' x 49 WITH 2' OF STONE (10' EFFECTIVE DIAMETER x 4' DEEP) SIDE AREA. 10 x 4 x PI = 126 SF (2.5) = 315 GAL/ DAY }BOTTOM AREA: 5' x 5' x PI = 78 SF (1.0) _ 8 GAL/DAY TOTAL, CAPACITY = 353 GALII-DAY - SEPTIC SYSTEM SECTION COVERS WITHIN 12" 74.0 OF FINISH GRADE TOP OF FOUNDATION LOT 25 \70.39 70.64 1000 GAL ELEV. D -BOX ELEV. 70.16 71.0 SEPTIC TANK 70.33 ,ELEV. ELEV. ELEV. TEE SIZES: INLET: 6" UP, 10" DOWN OUT LE : 6" UP, 19" DOWN t� DM DEMAREST-McLELLAN ENGINEERING 24 SCHOOL STREET P.O. BOX 463 WEST DENNIS, MASSACHUSETTS 02670 6z� a ✓ t ., R As THOMAS McLELLAN, P.E. JOHN Z. DEMAREST JR., P.L.S. 68.0 2' ELEV. �- ONE LEACH PIT 2' OF STONE (10' PEASTONE OF 3/4" - 1 1/2" WASHED STONE to 1 64.0 2'-ELEV. 101- x 0' x 49 WITH FF. D AM. x 4' DEEP) SITE AND SEWAGE PLAN LOCATION. • LOT 18 SUFFOLK I AVENUE PREPARED FOR- SCALE: OR SCALE: 1" = 30' REFERENCE: y DATE: 8-13-94 E: 96 REV: B-26-94 REV: 9-20-94