HomeMy WebLinkAboutSeptic As-Built Card3 E.E. 3 61. C MtlJ. 10' INV=34.48 MIS - �' M�TERS 1 ATER 4 P .Q 4. EPT T,4.N K H 20' LGA,' --)'NT-. 2500 GAL SEP11C TANK =3,3.07 -I V }MVV=33.35 -1000 GAL GREASE TRAP 3-90' LONG LEACHING TRENCHES INV=33.62 4' WIDE AND 2' DEEP TP1 GSE=34.2 RESE VENT L• "mIC.! 4.5 + 34.1, DIST. BOX INV=32.03 33.,-7+ 33.3 FF34.5 34.0 Il,_ 34.5 33.7 + 34.5 34.7 SITE PLAN. - 20) 90' 33.7+ 3 .6 I33�3 GRAPHIC SCALE 20 0 10 21 40 IN FEET ) 1 iiinch = 20 fL T 12' T 4' T 12' 1 37' + 33.7 3316 ! 3$.3 80 33.7 0 "b l\ SEPTIC SYSTEM PROFILE NOT TO SCALE �s .5 34.0 34.9 34.5 s Ii 34.6 34.6 -EACHING TRENCH 3-90' LONG LEACHING TRENCHES BOTTOM OF TEST ADJUSTED GROUND WATER ELEVA`ION DATE: JANUARY 28, 1997 BY: JDK HEALTH DEPT.: PETER BRYANTON TFcr uni F I ctF_u 9 TEST HOLE 2 GSE -34.7 DEPTH FROM SURFACE (INCHES) SOIL HORIZON SOILTEXTURE (USDA) SOIL COLOR (MUNSELL) SOIL MOTTLING OTHER STRUCTURE, STONES, ETC) 0-3" 0 ORGANIC ------- N/A 3'-10" A/E SANDY LOAM 10YR5/1 16'-36' B LOAMY SAND 10* -32' B LOAMY SAND 10YR5/4 2.5Y7/3 SAND 144'-150' 20R GRAVEL 32'-74' Cl MED. SAND 2.5Y7/3 AT 60" SAND FED LAYER 74'-132" C2 FINE TO MED. 2.5Y8/2 AT 74' SAND NO GROUND WATER ENCOUNTERED AT 132' ELEV. 73.2 PERC AT 48* -66' RATE= <2 MIN/IN DESIGN CALCULATIONS: DESIGN FLOW: PUBLIC PARK, TOILET WASTE 120 PARKING SPACES x 2 PEOPLE EACH=240 PEOPLE 240 PEOPLE x 5 GPD PER PERSON = 1200 GPD SEPTIC TANK REQUIRED = 1200 GPD x 200%=2400 GAL ACTUAL SEPTIC TANK SIZE = 2500 GAL LEACHING REQUIREMENTS: AREA= 3 x [90 x (2+2+4)] x 0.74 = 1598 GPD RESERVE AREA= 1598 GPD NT OF PEASTONE 1 .23 9.5 3/4" TO 1-7/2" WASHED STONE DEPTH FROM SURFACE (INCHES) SOIL HORIZON SOILTEXTURE (USDA) SOIL COLOR SOIL MOTTLING (MUNSELL) OTHER STRUCTURE, STONES, ETC) 0-5' 0 ORGANIC ------ N/A 5'-16' A/E SANDY LOAM 10YR5/1 16'-36' B LOAMY SAND 10YR5/4 36'-144' Cl FINE TO MED, 2.5Y7/3 SAND 144'-150' C2 COMPACT 2.5Y6/1 VERY FINE SAND NO GROUND WATER ENCOUNTERED AT 150" ELEV. 22.2 LEGEND -'° EXISTING CONTOUR 3E PROPOSED CONTOUR 36xO EXISTING SPOT GRADE - PROPOSED SPOT GRADE TEST PIT `OUTILITY POLE CATCH _BASIN NOTES: 1. SEPTIC SYSTEM SHALL BE INSTALLED ACCORDING TO 310 CMR 15.000 (TITLE V) AND THE TOWN OF YARMOUTH BOARD OF HEALTH REGULATIONS. 2. ALL PIPES SHALL BE 4" SHEDULE 40 PVC EXCEPT FOR THE BUILDING SEWER WHICH SHALL BE 4" CAST IRON. 3. THE DISTRIBUTION BOX SHALL BE WATER TESTED TO INSURE LEVELNESS AND EQUAL FLOW. 4. ALL COVERS TO SEPTIC SYSTEM UNITS SHALL BE BROUGHT TO FINISHED GRADE AND SHALL BE HEAVY DUTY CAST IRON. 5. THE OWNERS ENGINEER SHALL INSPECT AND CERTIFY SYSTEM CONSTRUCTION AND FINAL GRADING. 6. THE CONTRACTOR SHALL CALL DIGSAFE PRIOR TO CONSTRUCTION. vESCR G"C,N -awn -'reeked R E V I S 1 0 N S PROPOSED SUBSURFACE SEWAGE DISPOSAL SYSTEM TOR RECREATIONAL FACILITY AT OLD TOWN HOUSE ROAD SCALE: 1" = 20' DATE: JUNE 20, 1997 TOWN OF YARMOUTH ENGINEERING DIVISION 1146 ROUTE 28 SOUTH YARMOUTH, MA 02664 DRAWN BY: 95139-4 CHECKED BY: SHEET 1 -r 1