Loading...
HomeMy WebLinkAboutEngineered Plan - Rev. 2013N ACCESS COVERS MUST BE WITHIN 6- OF FINISH GRADE FIRST 2' TO / BE LEVEL -7 T Ztj 11 102.75 U 100. 1 � 2' 100.27 � o /00.0 9' MINIMUM. J' MAXIMUM COVER 1 3 OUTLET 2-500 GAL LEACHING CHAMBERS 'we WD-BOX W14' STONE AROUND. 12.8 ' w x 25'1 x 2 . d 1500 GALH-20 SEPTIC TANK H-20 6' CRUSHED STONE OR COMPACTED BASE PROF I L E: NOT TO SCALE `'00'E N 84°55II3.49' �r i / / ��'-�� - ---- - 111.0 rEXI$TiNG I w TANK/ - tu 09.6 BM. CORNER BH 1 v r -( I I 1 EL -110.41 h 1 r- 1 l ir/ /Jr 09. / DECK / I Z 1 / //EX/SjING `P(R OS£D - a o � 6 to// SA S/ � � I � ;\ G gAGE O I /tn CY / TPr2 1- \ O EXISTING y N -(- -- I DWELLING n 0 ® m 1 / 96 97 f 1 3d.2' 1 SHED TO BE REMOVED / j1y i I I I lyj I 1 I I { I sy / 105.1 BY. CORNER STEP EL -110.49 STONE WALL �/ x 1l~ I i I TNS � •.:•1•:: ... D -e X '.•'� �••::::.:.:: 1 C SOIR£MO AL / i ::: {:: .. ro 1 `- 1 \EAL I SEEI NOTE 5. 1 .:.' \ 1 1 \I 1•.•: ;.�). � �DR 1 tYE� Y 1-9 SPRUCE r p' 112.8' so Lor t7,11 m EX0,T.(NG STONE DRIVE,-I-J2S. F. 99.03 \ \ O \ 1.72 ' \ \\ O \ _ X9.40"W �\ \ 102.71 MULCH - 1 REUSE 2 EXISTING 1 500 GALLON LEACHING CHAMBERS W/NEW 4' STONE AROUND O RC' HID LANE INVERT EL E VA T I ONS : DESIGN CRITERIA- GENERAL NO TES : WATER L I NE INVERT AT BUILDING: 104.32 DESIGN FLOW: SEPTIC TANK AND D -BOX SHALL BE REINFORCED OHW- MIN 2' OF PEASTONE SOIL TEST PIT DA TA ® -T- UNDERGROUND TELEPHONE LINE INVERT IN SEPTIC TANK: 103.0 3 BEDROOMS AT 1/0 G.P.D. PER I. THIS PLAN IS FOR THE DESIGN AND CONSTRUCTION OR FILTER FABRIC INVERT OUT SEPTIC TANK: 102.75 BEDROOM EQUALS 330 G.P.D. BOTH SHALL BE WATERTIGHT. D -BOX SHALL BE WATER OF THE SEWAGE DISPOSAL SYSTEM ONLY. INVERT 1N DIST. BOX: 100.27 INDICATES 3/4" - ! 1/2" D/A. INVERT OUT DIST. BOX: 100.1 NO GARBAGE GRINDER 2. VERTICAL DATUM IS ASSUMED. FOR BENCH MARKS DOUBLE WASHED STONE TESTED FOR LEVEL WHEN THERE IS MORE THAN ONE SET. SEE SITE PLAN. TEST INVERT IN LEACH CHAMBER: 100.0 OUTLET. TP #1 SEPTIC TANK REQUIRED: TP #2 BOTTOM OF LEACH CHAMBER: 98.0 330 G.P.O. X 200% - 660 GAL. J. ALL CONSTRUCTION METHODS AND MATERIALS AND COLORHOR ADJUSTED GROUND WATER: N/A SEPTIC TANK PROVIDED: 1500 GAL. MIN. COLOR MAINTENANCE OF THE SEPTIC SYSTEM SHALL 1 -888 -DIG -SAFE AND THE LOCAL WATER DEPT. OBSERVED GROUND WATER: N/A /03.0 0* CONFORM TO MASS. D.E. P. TITLE 5 AND LOCAL BOTTOM OF TEST HOLE *I: 91.0 SOIL ABSORPTION SYSTEM REQUIRED: FILL BOARD OF HEALTH REGULATIONS. 0 DESIGN PERC RATE C 5 MIN/INCH SOIL TEXTURAL CLASS - 1 4. ALL SEPTIC SYSTEM COMPONENTS LOCATED UNDER 8. EFFLUENT L DAD I NG RATE - 0.74 GPD/SF 45" -------------------- AREAS SUBJECT TO VEHICULAR TRAFF i C OR GREATER 99.3 I" ----------------------- 330 GPD / 0.74 GPD/SF - 446 S.F. REQUIRED THAN 3' 1N DEPTH SHALL BE CAPABLE OF WITH- FINE IOYR STANDING H-20 WHEEL LOADS. SANDY IOYR PROVIDED: 2-500 GAL LEACHING CHAMBERS B SAND 6/6 A W/4' STONE AROUND. A-471 S.F. 5. ALL SEWER PIPE SHALL BE SCHEDULE 40 PVC OR FACILITY TO BE REMOVED FOR A DISTANCE OF 5' 52" -------------------- 471 S. F. x 0.74 - 348 G. P. D. 6' APPROVED EQUAL. `'00'E N 84°55II3.49' �r i / / ��'-�� - ---- - 111.0 rEXI$TiNG I w TANK/ - tu 09.6 BM. CORNER BH 1 v r -( I I 1 EL -110.41 h 1 r- 1 l ir/ /Jr 09. / DECK / I Z 1 / //EX/SjING `P(R OS£D - a o � 6 to// SA S/ � � I � ;\ G gAGE O I /tn CY / TPr2 1- \ O EXISTING y N -(- -- I DWELLING n 0 ® m 1 / 96 97 f 1 3d.2' 1 SHED TO BE REMOVED / j1y i I I I lyj I 1 I I { I sy / 105.1 BY. CORNER STEP EL -110.49 STONE WALL �/ x 1l~ I i I TNS � •.:•1•:: ... D -e X '.•'� �••::::.:.:: 1 C SOIR£MO AL / i ::: {:: .. ro 1 `- 1 \EAL I SEEI NOTE 5. 1 .:.' \ 1 1 \I 1•.•: ;.�). � �DR 1 tYE� Y 1-9 SPRUCE r p' 112.8' so Lor t7,11 m EX0,T.(NG STONE DRIVE,-I-J2S. F. 99.03 \ \ O \ 1.72 ' \ \\ O \ _ X9.40"W �\ \ 102.71 MULCH - 1 REUSE 2 EXISTING 1 500 GALLON LEACHING CHAMBERS W/NEW 4' STONE AROUND O RC' HID LANE 72" RESPONSIBIL I TY TO OBTAIN ALL PERMI TS. SPECIAL PERMITS. VARIANCES ETC. FOR THIS PROJECT. l0. IT SHALL REMAIN THE CLIENT'S RESPONSIBILITY TO HAVE THE PROPOSED BUILDING FOUNDATION 144NO WA TER NO WATER 9/.D DES J GNED TO ACCOUNT FOR THE EXISTING GRADE " 9/.0 J44 ' AND SOIL COND I T I ONS AT THE L OCA T I ON OF THE DATE: JULY 27. 1999 PROPOSED BUILDING. TEST BY: STETSON HALL WITNESSED BY: KELDA WELSH PERC RATE: C 2 MIN/INCH r �� Yarmouth bea1,, jDepartr ent P o JOHN �N DEMAREST,JR. t" Date ZA-% �L 1_ /?�' 01 S TE PLAN OF7 LAND 4 ORCHID LANE, MAP 55. PARCEL 52.2 WEST YARMOUTH. MA--- PREPARE-0 FOR: FEB 2 8 2013 MATT CH l L_ D S HEA a DEPI. SCALE: 1-- 20* NOVEMBER 13. 2012 REVISED: FEBRUARY 27. 2013 STEPHEN A. HAAS _ ENGINEERING, INC N 923 Route 6A Yarmouthport ° MA. 02675 ( 508 ) 362-8132 A LEGEND in CB CONCRETE BOUND -W WATER L I NE O HYDRANT 6. SEPTIC TANK AND D -BOX SHALL BE REINFORCED OHW- OVER HEAD WIRES SOIL TEST PIT DA TA ® -T- UNDERGROUND TELEPHONE LINE PRECAST CONCRETE OR APPROVED POLYETHYLENE. UNDERGROUND CABLEVISION LINE + 40.4 SPOT ELEVATION 40- •-_-- EXISTING CONTOUR 0 /0 '20 40 40 PROPOSED CONTOUR BOTH SHALL BE WATERTIGHT. D -BOX SHALL BE WATER INDICATES INDICATES PERCOLATION = OBSERVED TESTED FOR LEVEL WHEN THERE IS MORE THAN ONE TEST GROUNDWATER OUTLET. TP #1 TP #2 7. BEFORE CONSTRUCTION CALL 'DIG -SAFE', HOR I ZON ' TEXTURE COLORHOR l ZON TEXTURE COLOR 1 -888 -DIG -SAFE AND THE LOCAL WATER DEPT. 0 /03.0 0* 103.0 FOR L OCA T I ON OF UNDERGROUND UTILITIES. FILL 0 8. ALL UNSUITABLE MATERIAL IFILL. A & B HORIZONS) 45" -------------------- 99.3 I" ----------------------- 102.9 FINE IOYR SANDY IOYR ENCOUNTERED BELOW THE INVERT OF THE LEACHING B SAND 6/6 A LOAM 5/3 FACILITY TO BE REMOVED FOR A DISTANCE OF 5' 52" -------------------- 98.7 6' -------------------- 102.5 AROUND AND REPLACED WITH SAND IN ACCORDANCE C I MEDIUM IOYR B LOAMY IOYR WI TH TI TLE 5. SAND 7/3 SAND 6/6 13" ------- -_--- - - - - - 101.9 9. NO DETERMINATION HAS BEEN MADE AS TO Cl MEDIUM IOYR COMPLIANCE WITH DEED RESTRICTIONS OR ZONING SAND 7/2 REGULATIONS. IT SHALL REMAIN THE CLIENTS 72" RESPONSIBIL I TY TO OBTAIN ALL PERMI TS. SPECIAL PERMITS. VARIANCES ETC. FOR THIS PROJECT. l0. IT SHALL REMAIN THE CLIENT'S RESPONSIBILITY TO HAVE THE PROPOSED BUILDING FOUNDATION 144NO WA TER NO WATER 9/.D DES J GNED TO ACCOUNT FOR THE EXISTING GRADE " 9/.0 J44 ' AND SOIL COND I T I ONS AT THE L OCA T I ON OF THE DATE: JULY 27. 1999 PROPOSED BUILDING. TEST BY: STETSON HALL WITNESSED BY: KELDA WELSH PERC RATE: C 2 MIN/INCH r �� Yarmouth bea1,, jDepartr ent P o JOHN �N DEMAREST,JR. t" Date ZA-% �L 1_ /?�' 01 S TE PLAN OF7 LAND 4 ORCHID LANE, MAP 55. PARCEL 52.2 WEST YARMOUTH. MA--- PREPARE-0 FOR: FEB 2 8 2013 MATT CH l L_ D S HEA a DEPI. SCALE: 1-- 20* NOVEMBER 13. 2012 REVISED: FEBRUARY 27. 2013 STEPHEN A. HAAS _ ENGINEERING, INC N 923 Route 6A Yarmouthport ° MA. 02675 ( 508 ) 362-8132 A LEGEND in CB CONCRETE BOUND -W WATER L I NE O HYDRANT -G GAS LINE OHW- OVER HEAD WIRES _ 4' LIGHT POST -E- UNDERGROUND ELECTRIC LINE -T- UNDERGROUND TELEPHONE LINE - CTV- UNDERGROUND CABLEVISION LINE + 40.4 SPOT ELEVATION 40- •-_-- EXISTING CONTOUR 0 /0 '20 40 40 PROPOSED CONTOUR