HomeMy WebLinkAboutEngineered Plan - Rev. 1998SEPTIC PROFILE TEST HOLE Z,OGS T.O.F. AT EL 26.78', 4., / ACCESS COVER TO `WITHIN 6" OF FIN. GRADE (NOT TO SCALE) ACCESS COVER (WATERTIGHT) TO D.A. OJALA, SE /, ENGINEER: 25x5' MINIMUM ,75' OF COVER OVER PRECAST 24 WITHIN 6" OF FIN. GRADE `+ A. VON HONE, RS Lx5 2� SLOPE REQUIRED OVER SYSTEM WITNESS 24.5' - 25.0' : 24.98' 6/16/98 RUN PIPE LEVEL 2" DOUBLE WASHED PEASTONE DATE: FOR FIRST 2' _ < _2 MIN PER INCH \24.53' PROPOSED 1500 �3' MAX. PERC. RATE - (OR CULTEC FILTER FABRIC PER SPEC) GALLON SEPTIC 23.75, CLASS 1 & IV SOILS P N/A 24:0' __�- TANK (H- 10 ) 177 GAS 22.83' BAFFLE 23.0' r� 22.8' o0 ( >2 2' AT SIDES (5) CULTEC 330'S 2' „T SIDES 90 SLOPE) \_6" CRUSHED STONE OR MECHANICAL DEPTH OF FLOW 4' COMPACTION. (15.221 [21) 2' c� ELEV. ELEV. ( >4 % SLOPE) (1 % SLOPE) go 0 000 20.8' 0 23.8 D„ 24.5' TEE SIZES. „ INLET DEPTH = 10 3f 4" TO 1 1 /2 DOUBLE WASHED STONE OUTLET DEPTH 14" 14„ 28' LEACHING FOUNDATION SEPTIC T C G 17' TANK 17 D 80X 4 FACILITY 4' 36„ 9.2' 66 i V 16.8 LOT 9 84„ 11.6' >" 9 6„ -23 2 22 N PICKET F CE 6.42 ...__24 r X �� 1 r ---- 144 Ap LOAM 1OYR 3/2 LB 1OYR 5/6 C1 LS 2.5Y 6/4 C2 MED/COS 2.5Y 7/2 C3 SILT LOAM 2.5Y 7/ C4 MED/COS 2.5Y 7/2 18" 20.8' 42" 72" 16.8' 84" 15.8' 96" 11.8' 144" Ap LOAM 1OYR 3/2 8 LS 1OYR 5/6 C1 LS 2.5Y 6/4 C2 MED/COS 2.5Y 7/2 C3 ,SILT LOAM /& F.S. 2.5Y 7/1 C4 MED/COS 2.5Y 7/2 1 ASSESSORS MAP 109 PARCEL X7 ZC,N!NNG DISTRICT: N/A 21.0' YARD SETBACKS: FRONT SIDE _ REAR = PLAN REF: - FLOOD ZONE: C 17.5' 16.5' 12.5' .I - - - - NOTES: i r> NO WATER ENCOUNTERED 8 UIT TR E LP GARAGE PAVE APPROXIMATED FROM Y c.r�> 2 CROWN SEPTI,, DESIGN: GARBAGE DISPOSER Is NOT ALLOWED 1. DATUM IS ED 0 H ANNIS QUAD L I ON SLAB DRIVE ) oy 12" HOLLY -- -- DESIG,y FLOW: 3 110 330 EXISTING N BENCHMARK - __ _ - o LO . BEDROOMS ( GPD) GPD 2. MUNICIPAL WATER IS 20' CROW y ,n COR 8ULKHEA6 33O r (� .w- _-,.rOf�t='CI('_i\f i-'! _ 1R _ 2 ;:A, rn-rthdt r rr+r rr , :-.:. ,: L• r i - ..,,E P; O.I _ t .. : �, T 9 PCF. TH1 SEPTIC TANK. 330GPD 2 = 660 4. DESIGN LOADING FOR ALL PRECAST., UNITS TO BE AASHO -H W 1 (-) _ 5.' PIP JOINTS MA Z w E J0 N S TO BE DE ..WATERTIGHT.. S o W 1500 1 USE �+ __-- GALLON SEPTIC TANK . T 6, CONSTRUCTION DETAILS TO BE 1N ACCORDANCE ' WITH MASS. fn CP Z _ INVERT OUT �1 LEACI-ING. ENVIRONMENTALTI V 10' Q - CODE TLE ELEV .24.53 BH Lor 7 1 -� = 125.9 Area = 13,120 sq. t O + SIDE.,: 2(34.25 + 8.3) 2 (.74) 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO BE ^� 0.30 Acres u� USED FOR LOT LINE STAKING. ; N H2 0 34:25 x 8.3 74 2 ? 0.3 r INVERT T I BOTTOM: ( ) _ „ R ou � 8. PIPE FOR ..SEPTIC SYSTEM TO SCH. 40-4 PVC. O' DECK ELEV = 24.98' Q j r t W TOTAL 454 .F 336 9.` COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT t >> EXISTING S GPD E OU 1 > � INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED DWELLING 1 USE (5) CULTEC 330 S WITH 2 -0F STONE AT D a CHLRRY TF = 26.78 FROM BOARD OF HEALTH. SAVE) I f SIDES AND 1.5' AT ENDS Lu 10. CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING THE LOCATION OF ALL UNDERGROUND & OVERHEAD UTILITIES PRIOR 24 Z TO COMMENCEMENT OF WORK. 16 BA KHOE ACCESS �j UPGRADE PG t V 1 V 11�A �r� PI KET HE E LEGEND F NC SITE AND 5t1�/AGE PLAN N i i)0.0 PROPOSED SPOT ELEVATION _. YO't'AL OF UNSUITABLE SOIL / a OF 123.49, ,f�#25 GINGERBREAD LANE REVv, AROUND PERIMETER OF 0 10Ox0 EXISTING SPOT ELEVATION SYSTEM DOWN TO MED/COS LAYER (C4). REPLACE WITH CLEAN MED.o IN THE TOWN OF. ( SAND. ENGINEER TO INSPECT AND CERTIFY r' 1 (1OO T R EMOVAL t o- PROPOSED CONTOUR YARMOUTH 0 R) E 0 L � 1 N , 1 - - '100 EXISTING CONTOUR PREPARED FOR: LOT 5 4 MRS. P. HOLLAND 20 0 20 40 60 BOARD OF HEALTH C" G- JULY 18, 1998. MA . 1 - 20 APPRC)VED DATE SCALE. DATE: REV. 7/22/98 off 508-362-4541 fax 508 362-9880 o � drawn cape engineering•, Inc. ��' �P�`" Of �C b b �E H � �� ARNEOJALA q�ti SEP 09� ;0 CIVIL ENGINEERS CIVIL -• oI OJALA HEALTH DEPT. No. 30792 No. 26348 a� LAND SURVEYORS oda' 9F T€RSO Fsi CISTER�����`` F y 0 4 89 S --- / /���/�� 939 main st. armouth, ma. 02675 ---- / ------ 8 i 92 Y OJALA, L.S. DA TE ;